Loading...
HomeMy WebLinkAbout07/02/2013 - Agenda Packet - Planning & Zoning Commission L" Ar"" CITY OF COLLEGE STATION Home of Texas AerM University' Planning & Zoning Commission July 2, 2013 City Hall Council Chambers 1101 Texas Avenue College Station, Texas Special Regular Meeting 6:00 PM (*400r� AGENDA CITY OF COLLEGE STATION PLANNING & ZONING COMMISSION Home of TexasA&M Universiey" SPECIAL REGULAR MEETING JULY 2, 20139 AT 6:00 P.M. CITY HALL COUNCIL CHAMBERS 1101 TEXAS AVENUE COLLEGE STATION, TEXAS I. Call meeting to order. 2. Pledge of Allegiance. 3. Hear Citizens. At this time, the Chairman will open the floor to citizens wishing to address the Commission on planning and zoning issues not already scheduled on tonight's agenda. The citizen presentations will be limited to three minutes in order to accommodate everyone who wishes to address the Commission and to allow adequate time for completion of the agenda items. The Commission will receive the information, ask city staff to look into the matter, or will place the matter on a future agenda for discussion. (A recording is made of the meeting; please give your name and address for the record.) All matters listed under Item 4, Consent Agenda, are considered routine by the Planning & Zoning Commission and will be enacted by one motion. These items include preliminary plans and final plats, where staff has found compliance with all minimum subdivision regulations. All items approved by Consent are approved with any and all staff recommendations. There will not be separate discussion of these items. If any Commissioner desires to discuss an item on the Consent Agenda it will be moved to the Regular Agenda for further consideration. 4. Consent Agenda 4.1 Consideration, discussion, and possible action on Absence Requests from meetings. • Mike Ashfield—July 2, 2013 • Jodi Warner—July 2, 2013 Regular Agenda 5. Public hearing, presentation, discussion, and possible action on a Final Plat for Home2 Suites Subdivision being a replat of Lodgeco Subdivision Lot 2, North Park Section II Lots 2-4, and former Meadowland Street right-of-way consisting of approximately 2.1 acres at 300 Texas Avenue. Case# 13-00900053 (M.Hester) 6. Discussion and possible action on future agenda items — A Planning & Zoning Member may inquire about a subject for which notice has not been given. A statement of specific factual information or the recitation of existing policy may be given. Any deliberation shall be limited to a proposal to place the subject on an agenda for a subsequent meeting. 7. Adjourn. Consultation with Attorney{Gov't Code Section 551.0711;possible action. The Planning and Zoning Commission may seek advice from its attorney regarding a pending and contemplated litigation subject or attorney- client privileged information. After executive session discussion,any final action or vote taken will be in public. If litigation or attorney-client privileged information issues arise as to the posted subject matter of this Planning and Zoning Commission meeting,an executive session will be held. Notice is hereby given that a Special Regular Meeting of the College Station Planning&Zoning Commission,College Station,Texas will be held on July 2,2013 at 6:00 p.m.at City Hall Council Chambers,1101 Texas Avenue,College Station,Texas. The following subjects will be discussed,to wit: See Agenda. Posted this the day of June,2013,at CITY OF COLLEGE STATION,TEXAS By Sherry Mashburn,City Secretary By Kathy Merrill,Interim City Manager I,the undersigned,do hereby certify that the above Notice of Meeting of the Planning& Zoning Commission of the City of College Station,Texas,is a true and correct copy of said Notice and that I posted a true and correct copy of said notice on the bulletin board at City Hall, 1101 Texas Avenue, in College Station, Texas, and the City's website,www.cstx.gov. The Agenda and Notice are readily accessible to the general public at all times. Said Notice and Agenda were posted on June.2013,at and remained so posted continuously for at least 72 hours preceding the scheduled time of said meeting. This public notice was removed from the official posting board at the College Station City Hall on the following date and time: by Dated this day of 2013. CITY OF COLLEGE STATION,TEXAS By Subscribed and sworn to before me on this the day of 2013. Notary Public-Brazos County,Texas My commission expires: This building is wheelchair accessible. Handicap parking spaces are available. Any request for sign interpretive service must be made 48 hours before the meeting. To make arrangements call (979) 764-3541 or (TDD) 1-800-735-2989. Agendas may be viewed on www.cstx.Eov.Planning and Zoning Commission meetings are broadcast live on C CITY OF COLLEGE STATION Planning eh-Development Services Absence Request Form For Elected and Appointed Officers Name Mike Ashfield Request Submitted on 6/25/13 I will not be in attendance at the meeting of 7/2/13 Special Meeting for the reason(s) specified: (Date) Out of town for work. Mike Ashfield (*01"" CITY OF COLLEGE,STATION Planning ear Development Services Absence Request Form For Elected and Appointed Officers Name Jodi Warner Request Submitted on 6/10/2013 I will not be in attendance at the meeting on 7/02/2013 for the reason specified: (Date) Out of town Signature Jodi Warner CITY OF COLLEGE STATION FINAL PLAT for Home2 Suites Being a Replat of Lodgeco Subdivision Lot 2, North Park Section II Lots 2-4, and former Meadowland Street Right-of-Way 13-00900053 SCALE: One lot on approximately 2.1 acres LOCATION: 300 Texas Ave ZONING: PDD Planned Development District APPLICANT: Steve Duncan, Jones and Carter PROJECT MANAGER: Morgan Hester, Staff Planner mhester@cstx.gov PROJECT OVERVIEW: This property was rezoned from C-1 General Commercial to PDD Planned Development District in December 2011. The purpose of this replat is to consolidate four lots and abandoned easements and abandoned Meadowland right-of-way into one lot as required by the rezoning. RECOMMENDATION: Staff recommends approval of the Final Plat with the following conditions: 1. Revise title block to read `Final Plat of Home2 Suites being a replat of Lodgeco Subdivision Lot 2, North Park Section II Lots 2-4, and former Meadowland Street right-of-way' 2. Include portion of former Meadowland Street right-of-way in proposed lot if quit claim document is signed by adjacent owner. Planning &Zoning Commission Page 1 of 3 July 2, 2013 7 =y Ez LO i W W r nv s�roOr W i 4�o w EL f W y W nd �. �aJ .. o # Planning &Zoning Commission Page 2 of 3 July 2, 2013 DEVELOPMENT HISTORY Annexation: 1939 Zoning: PDD Planned Development District in December 2011 Previously C-1 General Commercial and R-4 Multi-Family Preliminary Plat: The three smaller lots and the northern portion of the larger lot were platted as Lodgeco Subdivision in December 1993. The remaining portion of the larger lot was platted as a portion of Gorzycki's Meadowland upon annexation. Site Development: This site is currently undeveloped as three fourplexes were recently demolished. COMMENTS Parkland Dedication: Parkland dedication is not required or proposed with this plat. Greenways: Greenways are not required or proposed with this plat. Pedestrian Connectivity: A sidewalk is required along Texas Avenue with this plat. A sidewalk will also be constructed along the public way on the former Meadowland Street. Bicycle Connectivity: Bicycle connectivity is not required or proposed with this plat. Impact Fees: N/A REVIEW CRITERIA Compliance with the Unified Development Ordinance: The Final Plat is in compliance with the Subdivision Requirements of the Unified Development Ordinance. STAFF RECOMMENDATIONS Staff recommends approval of the Final Plat with the following conditions: 1. Revise title block to read `Final Plat of Home2 Suites being a replat of Lodgeco Subdivision Lot 2, North Park Section II Lots 2-4, and former Meadowland Street right-of-way' 2. Include portion of former Meadowland Street right-of-way in proposed lot if quit claim document is signed by adjacent owner. SUPPORTING MATERIALS 1. Application 2. Copy of Final Plat Planning &Zoning Commission Page 3 of 3 July 2, 2013 CL Cs) C'I zW— M­ LO LL— --------- —-—------- --——————————————————————— LU -i 02 -f—J jail e -FT 2 p --p I 0 3 3 NN 02 in _41 I 12! FOR OFFICE VSE ONLY CASE NO.: DATE SUBMITTED: ' TIME: CITY OP COLLEGE STATION Home of TexasAdM University' STAFF: FINAL PLAT APPLICATION (Check one) ❑ Minor ❑ Amending ❑ Final ❑ vacating ❑X Replat ($700) ($700) ($932) ($932) ($932) Is this plat in the ETJ? ❑X Yes ❑ No Is this plat Commercial ❑X or Residential ❑ MINIMUM SUBMITTAL REQUIREMENTS: $700-$932 Final Plat Application Fee (see above), $233 Walver Request to Subdivision Regulations Fee (if applicable). $600 (minimum) Development Permit Application / Public Infrastructure Review and Inspection Fee. Fee is 1%of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is> $600, the balance is due prior to the issuance of any plans or development permit). 1K-1pp[icatiDn completed in full. This application form provided by the City of College Station must be used and may not be adjusted or altered. Please attach pages if additional information is provided. Fourteen (14)folded copies of plat. (A signed mylar original must be submitted after approval.) ❑ Two(2) copies of the grading, drainage, and erosion control plans with supporting drainage report. ❑ Two(2)copies of the Public infrastructure plans and supporting documents (if applicable). []/Copy of original deed restrictions/covenants for replats (if applicable). 14 Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate current within ninety (90) days. The report must include applicable information such as ownership, liens, Jencumbrances, etc. Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. The attached Final Plat checklist with all items checked off or a brief explanation as to why,they are not. NOTE: A mylar of the approved preliminary plan must be on file before a final plat application will be considered complete. If the mylar is submitted with the final plat application, it shall be considered a submittal for the preliminary plan project and processed and reviewed as such. Until the mylar has been confirmed by staff to be correct, the final plat application will be considered incomplete. Date of Optional Preapplication or Stormwater Management Conference 2011-08-17 NAME OF PROJECT Home2 Suites ADDRESS 300 South Texas Avenue ySPECIFIED LOCATION OF PROPOSED PLAT: 1300 South Texas Avenue, APPLICANT/PROJECT MANAGER'S INFORMATION (Primary contact for the project): Name Steve Duncan, P.E. E-mail SDuncan@jonescarter.com Street Address 1716 Briarcrest Drive, Suite 160 City Bryan State TX Zip Code 77802 Phone Number (979) 731-8000 Fax Number (979) 846-2893 1/11 Page 1 of 9 PROPERTY OWNER'S INFORMATION (All owners must be identified. Please attach an additional sheet for multiple owners): Name Suraj Demla E-mail surajdemla@yahoo.com Street Address 3525 Sandy Trail Lane City Plano State TX Zip Code 75023 Phone Number (972) 642-0873 Fax Number ARCHITECT OR ENGINEER'S INFORMATION; Name Same as Applicant/Project Manager E-mail Street Address City _ State Zip Code Phone Number Fax Number Do any deed restrictions or covenants exist for this property? ❑ Yes ❑X No Is there a temporary blanket easement on this property? If so, please provide the Volume NA and Page No. Total Acreage 1.9718 Total No. of Lots 1 R-O-W Acreage Existing Use Vacant Proposed Use Commercial/Hotel Number of Lots By Zoning District 1 / 1 Average Acreage Of Each Residential Lot By Zoning District: NA / NA Floodplain Acreage .0 Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? r1 Yes rl No This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s)and you are requesting the application be reviewed under previous ordinance as applicable? r'I Yes IKi No If yes, provide information regarding the first approved application and any related subsequent applications(provide additional sheets if necessary): I Project Name: City Project Number(if known): Date/Timeframe when submitted: 1/11 Page 2 of 9 A statement addressing any differences between the Final Plat and Preliminary Plan (if applicable): 14rlA Requested waiver to subdivision re ulations and reason for same (if applicable): A Regarding the waiver request, explain how: 1. There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land. ?NA 2. The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant. NA 3. The granting of the waiver will not be detrimental to the public health, safety, or welfare, or injurious to other property in the area, or to the City in administering subdivision regulations. A 4. The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of the Unified Development Ordinance. A Fee in lieu of sidewalk construction is being requested because of the following condition (if applicable): 1. r An alternative pedestrian way or multi-use path has been or will be provided outside the right-of-way; 2. ri The presence of unique or unusual topographic,vegetative, or other natural conditions exist so that strict adherence to the sidewalk requirements of the UDO is not physically feasible or is not in keeping with the purposes and goals of the UDO or the City's comprehensive Plan; 3. FI A capital improvement project is imminent that will include construction of the required sidewalk. Imminent shall mean the project is funded or projected to commence within twelve (12) months; 4. Existing streets constructed to rural section that are not identified on the Thoroughfare Plan with an estate/ rural context; 5. When a sidewalk is required along a street where a multi-use path is shown on the Bicycle, Pedestrian, and Greenways Master Plan; ��� Page 3 of 9 6. F The proposed development is within an older residential subdivision meeting the criteria in Platting and Replatting within Older Residential Subdivisions Section of the UDO;or 7. F-' The proposed development contains frontage on a Freeway I Expressway as designated by Map 6.6, Thoroughfare Plan-Functional Classification, in the City's Comprehensive Plan. Detailed explanation of condition identified above: NOTE: A waiver to the sidewalk requirements and fee in lieu of sidewalk construction shall not be considered at the same time by the Planning &Zoning Commission. Requested Oversize Participation Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE: Streets Sidewalks No. of acres to be dedicated +$ development fee Sanitary Sewer Lines No. of acres in floodplain No. of acres in detention Water Lines Channels No. of acres in greenways OR Storm Sewers FEE IN LIEU OF LAND: Bike Lanes I Paths No. of SF Dwelling Units X $ _ $ (date)Approved by Parks& Recreation Advisory Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct, and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY, this application must be accompanied by a power of attorney statement from the owner. If there is more than one owner, all owners must sign the application or the power of attorney. If the owner is a company, the application must be accompanied by proof of authority for the company's representative to sign the application on its behalf. LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above. Signature and title j_L M f vj ,36(j._ Date 1/11 Page 4 of 9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1. No work of any kind may start until a permit is issued. 2. The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Occupancy is issued. 5. The permit will expire if no significant work is progressing within 24 months of issuance. 6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP. 7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre- pour) and post construction. 8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9. If,stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be designed and constructed first in the construction sequence of the project. 10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that all debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities.All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project.All of the applicable codes and ordinances of the City of College Station shall apply. 11. The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications, and Standard Details.All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12. Release of plans to (name or firm) is authorized for bidding purposes only, I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13. I, THE OWNER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE,AND ACCURATE. Property O enw r(s) Date Engineer Certification: 1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part of the project will be constructed first in the construction sequence. 2. 1 will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction including NOI and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may require a sedimentation basin. 3. The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 4. I, THE ENGINEER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND ACCURATE. Engineer Date 1/11 Page 5 of 9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1. No work of any kind may start until a permit is issued. 2. The permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Occupancy is issued. 5. The permit will expire if no significant work is progressing within 24 months of issuance. 6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP. 7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre- pour)and post construction. 8. Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be designed and constructed first in the construction sequence of the project. 10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that all debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities.All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 11. The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications, and Standard Details. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12. Release of plans to _ (name or firm) is authorized for bidding purposes only. I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13. I, THE OWNER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE,AND ACCURATE. Property Owner(s) Date Engineer Certification: 1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part of the project will be constructed first in the construction sequence. 2. 1 will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction including NOI and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may require a sedimentation basin. 3. The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified Design Guidelines. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 4. I, THE ENGINEER, AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE,AND ACCURATE. /�l7 ngi75Zneer Date 1/11 Page 5 of 9 The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans, Final Plats, Construction Plans, Fill /Grading Permits, and Clearing Only Permits:* A. I, Steve E. Duncan, P.E. certify, as demonstrated in the attached drainage study, that the alterations or development covered by this permit, shall not: (i) increase the Base Flood elevation; (ii) create additional areas of Special Flood Hazard Area; (iii) decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the velocity of flow in the Base Flood event is greater than one foot per second. This area can also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the depth of from the BFE to natural ground is 18 inches or greater; (iv) reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than one foot per second without acceptable compensation as set forth in the City of College Station Code of Ordinances, Chapter 13 concerning encroachment into the Special Flood Hazard Area; nor (v) increase Base Flood velocities. beyond those areas exempted by ordinance in Section 5.11.3a of Chapter 13 Code of Ordinances. 4WI, t1 Engineer Date Initial * If a platting-status exemption to this requirement is asserted, provide written justification under separate letter in lieu of certification. Required for Site Plans, Final Plats, Construction Plans, and Fill /Grading Permits: B. I, Steve E. Duncan, P.E. , certify to the following: (i) that any nonresidential or multi-family structure on or proposed to be on this site as part of this application is designed to prevent damage to the structure or its contents as a result of flooding from the 100-year storm. z Engineer Date Additional certification for Floodway Encroachments: C. I, Steve E. Duncan, P.E. , certify that the construction, improvement, or fill covered by this permit shall not increase the base flood elevation. I will apply for a variance to the Zoning Board of Adjustments, Engineer Date 1111 Page 6 of 9