HomeMy WebLinkAbout1986-1629 - Ordinance - 01/09/1986ORDINANCE NO. 1629
AN ORDINANCE OF THE CITY OF COLLEGE STATION, TEXAS AMENDING CIIAPTER 3,
SECTION 1 OF THE CODE OF ORDINANCES, CITY OF COLLEGE STATION, TEXAS.
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF COLLEGE STATION, TEXAS:
WHEREAS, the City Council held a public hearing in the City Hall at 7:00
P.M. on Thursday, the 9th of January, 1986, on the question of amending
Chapter 3, Section l, of the Code of Ordinances, City of College Station
relating to building regulations and the adoption of a Building Code,
AND, WHEREAS, the City Council has determined the following:
That Chapter 3, Section lA of the Code of Ordinances, City of College
Station, Texas is hereby amended to read as follows:
A. STANDARD BUILDING CODE ADOPTED.
The Standard Buildin9 Code, specifically the 1985 Edition published by
The Southern Building Code Congress, a copy of which is on file in the
office of the City Secretary of the City of College Station, Texas, is
hereby adopted and designated as the building code of the City of
College Station. Said code is adopted to the extent as though such code
were copied at length herein, subject however to the omissions, additions,
and amendments contained in the chapter.
II.
That Chapter 3, Section lB of the Code of Ordinances, City of College
Station, Texas is hereby amended to read as follows:
B. AMENDMENTS TO STANDARD BUILDING CODE
The above referenced Standard Buildin9 Code is hereby amended as follows:
(1)
Section 102.4 is amended by deleting therefrom the following sentence:
"All unsafe buildings are hereby declared illegal and shall be abated
by repair and rehabilitation or by demolition in accordance with
the provisions of the Standard Code of the elimination or repair of
unsafe buildings."
(2}
Section 105.2.3 is amended to read as follows: 105.2.3 Home Owner
Permit - A property owner shall obtain a permit for work to do done
by him on a building owned and occupied by him as his homestead.
After twenty-four {24) months the permit is void and must be re-
permitted by the home owner or a contractor at the discretion of
the Building Official and subject to appeal to the Board of
Adjustments and Appeals.
Table 400 shall be amended by the addition of the superscript "k"
to the allowable areas tabulated in the Type III, V, VI columns
for Group R Occupancy, story height three {3) and above, and the
addition to the table of a new note "k" to read: "Two (2) remote
independent means of egress from each floor area occupied by
00160,.
(4)
separate tenants shall be provided."
Section 402.2.3.0 shall be amended by adding to the definition of
mezzanine" a new sentence to read: "A mezzanine shall be considered
to be an additional story."
(5) Section 402.2.3.1 shall be deleted.
(6) Section 402.2.3.2 shall be deleted.
(7) Section 402.2.3.3 shall be deleted.
{8) Section 402.2.3.4 shall be deleted.
(9) Section 402.2.3.5 shall be deleted.
(lO)
(11)
(12)
(13)
(14)
05)
(16)
Section 403.2 is amended by deleting therefrom the following phrase:
"except that in Group B-Business and Group S-Storage Buildings,
non-fire rated partitions may be used to separate tenants provided
no area between partitions rated at one (1) hour or more exceeds
three thousand (3,000) square feet.
Section 404.7 shall be amended by adding the following sentence:
"There shall be required a supplementary lighting system in addition
to the regular system by local electric power in Group A Small
Assembly."
Section 412.9 shall be added to read as follows" 412.9 Public Rental
Storage Warehouse (A) a public rental storage warehouse is a
structure used solely for storage occupancy, which is divided into
separate spaces accessible to each tenant and in which the management
does not bear responsibilities as a warehouseman. (B) Tenant
separation shall not be required in a public rental storage
warehouse. (C} A wall having fire resistance of not less than
{2) hours, parallel to the longitudinal axis of the building and
dividing the building into two {2) parts of equal area insofar
as the configuration of rental spaces permits shall be provided
in each public rental stroage warehouse building.
Section 506.1.1 is amended by deleting therefrom the phrase "or
areas of refuge (Compartmentation) in accordance with Section
506.9."
Section 506.8.3 shall be added to read as follows: "All enclosed
stairways are to be pressurized." (See Section 506.ll
Section 506.9 shall be deleted.
Section 506.11 shall be added "The one and one-half (1 1/2) inch
wet standpipe hose and nozzles is not required, however, the Fire
Department risers and hose connections are to be provided in the
corridor and not in the stairway."
(17) Section 704.3 - Table 704.3 shall be amended to read as follows:
00 60
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
"Minimum flame spread classifications for all group A-Assemblies
shall be Class A interior finish material in exit corridors and
exits when sprinklered."
Section 704.4 shall be amended with the first paragraph to read as
follows: "Delete Exceptions."
Section 706.6 shall be amended with the first paragraph to read as
follows: "Outside the fire district one {1) and two (2) story
single family dwellings and accessory buildings not over four-
thousand (4,000) square feet in area and located not less than
seven and one half feet (7 1/2) from the property line may be
roofed with grade labeled No. 1 and No. 2 wood shingles or shakes
with a minimum butt thickness of one half inch {1/2) securely
fastened with rust resistant nails."
Section 901.8.6 shall be added as follows: "An approved auto-
matic sprinkler system shall be provided in group A-Assembly
occupancies (except churches), when a group A-Assembly total
floor area exceeds {5000) sq. ft."
Section 901.8.7 shall be added to read as follows: "{7) An
approved sprinkler system shall be provided in all structures
where the total area exceeds {15,000) sq. ft. per floor and all
structures exceeding two stories in height."
Section 901.8 (d) shall be added to read as follows: "An approved
sprinkler system shall be provided in all hotels and motels."
Section 813 is amended "An approved fire extinguishing equipment
shall be provided for the protection of duct systems, grease removal
devises and heads."
Cooking equipment (such as fat fryers, ranges, griddles and broilers)
which may be a source of ignition of grease in the hood, grease
removal devise, or duct shall be protected by approved extinguishing
equipment.
Listed fire extinguishing system shall be installed in accordance
with the terms of their listing and the manufacturer's instructions.
Carbon Dioxide extinguishing systems NFPA 12
Dry chemical extinguishing systems NFPA 17
Section 1703.12 shall be amended by adding "All concrete slabs at
grade shall have special termite protection by soil treatment or
other approved methods of termite protection", per Section 1703.11.
Section 1707.2.1 shall be amended to read as follows: "Not less
than (3) studs shall be installed at every corner of an exterior wall."
OOA60[
(26)
(27)
(28)
(29)
(3O)
(31)
(32)
(33)
(34)
(35)
(36)
Section 1708.7 shall be amended to read as follows: "Attic spaces
shall be provided with an access opening not less than twenty (20)
inches by twenty-four (24) inches. Access opening shall be readily
accessible and provided with a lid or device that may be easily
removed or operated, when mechanical equipment i~ to be installed
in the attic and only interior access is to be provided. The access
opening shall be not less than specified above, but in no case less
than the size required to install or remove the largest major
component of the unit without disassembly. Access is not required
when the clear height of the attic space measured at the roof peak,
is less than twenty-four (24) inches."
Section 2301.2.l.2 shall be amended to read: "Ground sign means an
outdoor advertising display sign when such sign is supported by
uprights or braces in or upon the ground."
All Appendices except D and H are hereby adopted.
Section A-101.4.5 shall be
"Department of law in this
Attorney."
amended by adding the following sentence:
instance shall be construed to mean City
Section A-103.4.4 shall be amended by adding the following sentence:
"The Building Official may require such survey as may be necessary
to establish the location of property lines, public right-of-way
lines and public easements where the locations effect the proposed
work, and the said surveys shall be made by a registered public
surveyor at the applicant's expense."
Section A-103.4.5 shall be added to read: "There shall be no
combustible or flammable materials placed on site, lot or subdivision
where waterlines and fire hydrants as required by the applicable
subdivision regulations are not completed and in service and where
all-weather access for emergency vehicles does not exist to within
one-hundred-fifty (150) feet of the most remote part of the structure."
Section A-103.5 is amended by deleting therefrom the phrase "to
pay a license tax as provided in the general license ordinance."
Section 101.3.2 shall be added: "The City of College Station will
not inspect anything on federal or state property."
Table 600 shall be amended to read "After 15' there is no firewall
on exterior walls required (N L %)."
Add Accessory Portable Storage Building
Portable storage buildings are defined as those portable storage
buildings that are not permanently affixed to the ground. An
accessory portable storage building notover one hundred (100} sq.
ft. in area will be allowed one {1) per lot without a building
permit if it can be moved and sanitary facilities, watersupply and
electric system are not contained in the structure and structure is
not placed in surface drainage easement.
Section 1104.4 shall be amended to read as follows:
Every sleeping room in one and two family dwellings shall have at
least one operable window or exterior door approved for emergency
egress or rescue. The units must be operable from the inside to a
00160
Full clear opening without the use of seperate tools. Where windows
are provided as a means of egress or rescue, they shall have a sill
height of not more than forty-four {44) inches above the floor.
All egress or rescue windows from sleeping rooms shall have a
minimun net clear opening of twenty-four (24) inches by twenty {20)
inches.
III.
Should any section, paragraph, sentence, clause, phrase, or word of
this ordinance be declared unconstitutional or invalid for any
purpose, the remainder of this ordinance shall not be affected
thereby.
IV.
All ordinances or parts of ordinances in conflict herewith are
repealed to the extent of the conflict only, including but not
limited to Ordinances No. 1938, Ordinance No. 1442, and
Ordinance No. 1567.
(Penalty)
"Any violation of this ordinance is punishable by a fine not to
exceed $1,000 as provided for by Article 4.14 of the Texas Code
of Criminal Procedure, as amended. In the event that a fine not
to exceed $1,000 is greater than the +ntended jurisdictional
limit, than the fine imposed shall not exceed $200".
WHEREAS, the preservation of the general welfare of the public
necessitates immediate action, this Ordinance shall be effective
from and after the date of this passage as provided by the Charter
of the City of College Station .
PASSED AND APPROVED THIS THE
ATTEST:
lan Jon~//~ty Secretary
9th DAY OF January
APPROVED- / ~//
Gar~-PI~l~, Mayor ~
· 1986.
00¢60',
BUILDING PERMIT FEES
Such fees are authorized under Chapter 3 of the Code of Ordinances City of
College Station.
For the purpose of these fees, value shall be based on the most recent
building valuation data sheet published by the Southern Building Code
Congress, with appropriate regional modifiers. Such valuation shall include
the electrical, plumbing, mechanical or other systems contained thereto.
In addition the Building Official may require an applicant to submit a
signed construction contract showing all labor and materials or other
appropriate proof of construction costs in order to establish such valuation.
For each separate structure, the building permit fees shall be as follows:
Valuation of structure
and site improvements
Fee
$0.00 to $2000.00
$5.00 per thousand or fraction thereof
$2001.00 to $15,000.00
$10.00 for the first $2000.00 plus $3.00
for each additional thousand or fraction
therof, to and including $15,000.00
$15,001.00 to $50,000.00
$49.00 for the first $15,000.00 plus
$2.50 for each additional thousand or
fraction thereof, to and including
$50,000.00
$50,001.00 to $100,000.00
$136.50 for the first $50,000.00 plus
$2.00 for each additional thousand or
fraction thereof, to and including
$100,000.00
$100,001.00 to $500,000.00
$236.50 for the first $100,000.00 plus
$1.25 for each additional thousand or
fraction thereof, to and including
$500,000.00
$500,001.00 and up
$736.50 for the first $500,000.00 plus
$0.75 for each additional thousand or
fraction thereof.
"For one and two family residential construction, the valuation of structure and
site improvements shall be calculated at $40.00 X the heated floor area and
$20.00 X the unheated area."
00 .60c
Building Valuation Data
Regional Modifiers-
EASTERN U.S .......... Modifiers
Connecticut ..................... 1.09
Delaware ................................ 1 10
Oismct of Columbia ............... 1.07
Florida ................................. 1.01
Georgia .................................. 0 96
Maine ................................ 1.01
Maryland ..................................1.02
Massachusetts ........................ 1.11
New Hampshire ...................... J.02
New ,Jersey ............................ 1.16
New York ................................. 1.11
North Carolina ......................... 0.93
Pennsylvania ............................. 1.09
Rhode Island ............................ 1.07
South Carolina ......................... 0.92
Vermont .................................. 1.0!
Vir~i~a ........... ..=.......~ ................. 0.97 .
West Virginia ............................ 1.10
CENTRAL U.S .......... Modifiers
Alabama ................................... 1.00
Arkansas .................................. 1.00
Illinois ....................................... 1.1!
Indiana ...................................... 1.10
Iowa .......................................... 1.09
Kansas ...................................... !.06
Kentucky .................................. !.07
Louisiana .................................. 1.03
Michigan ................................... 1.12
Minnesota ................................ 1.09
Mississippi ................................ 0.98
Missouri .................................... 1. ! i
Nebraska ................................. 1.07
North Dakota ........................... 1.10
Ohio .......................................... 1.13
Oklahoma ................................. 1.05
.South Dakota .................... ~..._....1.01
Tennessee ................................. 1.00
Texas ........................................ 1.01
· Wisconsin ................................. 1.09
WESTERN U.S ....... Modifiers
Alaska ........................... 1.58
Arizona ............................ I. 12
California ........................... 1 22
Colorado .......................... 1 08
Hawaii ............................. i.24
Idaho .............................. I 08
Montana .......................... 1.08
Nevada ........................... ! 18
New Mexico ....................... 1 08
Oregon ............................ I 16
Utah ................................. 1.07
Washington ....................... I. 17
Wyoming .......................... I 07
FIRE INSPECTOR S MA N(L.4 I
( '0 I"ER ?-ES'
Inspector s M an ua,
by October I,
be announced at the
1985 Also, the winner will
' of The Ftre
~ m the
%nd IX.~,grt, To
G'~. FLsher. )e, socmte Engineer
Southem,,Budd,ng Code Congre~
900 Montc~ar Road
B,rm,ngham. Alabama 35213
Building Valuation Data
rhu Iollowmg Budding Valuallun Dala
n.,presenr-, Ihe avera~ cosls for m~t
buddings and ~s presenl~ as a ~rv~ce tu
uur members These umt costs include
~nspect and consltu~.l Ihe budding and
hsh,d h,_'rc h ',h,)uld I~., holed thai il,t'~e
Type of Con-
ettuction Type Type Type Type IV Type V Type VI
Apartment (R) 49 50 46 00 43 ,50 43 S0 41 00 42 50 39 (30 36.50 34 00
Aulornobde
Parking Structure (S) 34 00 30.50 28 00 28 iX) 26 O0 27 50 24 50 26 50 24 50
Church(A) 5600 5250 4750 4550 4250 4550 4150 3950 3700
Covalescent (I) 67.00 63 `50 56.00 56 00 52 `50 54 00 NP 47 50 NP
Eclucat~onal (E) 55 `50 52 00 47 00 47 00 44 00 47.50 44 00 44 00 41 ,50
Factory Industrial (F) 34 00 30 50 26 00 26 00 23 50 25 50 23 00 23 50 19 50
Hazardous (H) 28.50 26 00 23.50 23.50 20 00 23 50 20 00 NP NP
HospdaJ (1) -- 95 ,50 -' 92.50 89 50 89 50 87 00 84 SO NP 7] `50 NP
Hotel (R) 53.50 50.50 45.50 44.00 4] 00 43 50 40 50 43 SO 40 50
Shed (S) 26.50 23.50 21.00 2! 00 19.50 2! 00 19 50 20 00 18 00
Pubhc Garage (S) 34 00 3 !.00 28.00 24 `50 22 00 24 50 22 00 24 50 22 00
Restaurant iA or B) 58.50 56.00 50.50 49 `50 47.00 49 SO 47 00 49 SO 46.00
Retad Store (M) 45 50 43 00 36.50 35 00 32 00 34 50 31 00 34 00 30.50
Servme Station (B) 54.00 ,50 ,50 46 00 45 ,50 43 00 45 00 42 50 39 00 37 SO
Theater (A) 63.00 SO.gO 49.50 47.00 45.00 47 00 44 IX) 47 00 44.00
Warehouse (S) 27.SO 24.50 22.00 22.130 !9 50 22 00 19 50 22 iX) 19 `50
SHELL - 1/2 of prJce)
I NP-Not permitted by code
2 Apartment Basement ~ 50/sq
Dwelling Basement $15 So/sq.
3. Sprinklers $1 So/sq. il
00 61C