HomeMy WebLinkAboutAugust 7August 7, 1986
MEMORANDUM
TO: Planning & Zoning Commission r ,
Steve Andrews, Municipal Development Group \�/'
FROM: James M. Callway, Assistant Director of Planning
David J. Pullen, City Engineer
Carol Elmore, Assistant City Attorney
Lavern Dube, GTE
Terran Sanchez, Lone Star Gas
Bill Riley, Water & Sewer Department
Jimmy McCord, McCord Engineering, Inc.
Ray Havens, Electric Department
Shirley Volk, Planning Technician
SUBJECT: Final Plat - Replat of Timber Ridge Addition Third
Installment (7.47 acres) - 86 -209
A Presubmission Conference was held on 8 -6 -86 to review the above
referenced resubdivision plat, and approval was recommended with
the following conditions *:
(1) Lone Star Gas requires an additional 30 feet, making a total
of a 45 foot easement along Rhett Butler Drive to accommodate
relocation of the existing gas line from the 50 foot easement
running through this land. This must be a separate easement for
only the gas line.
(2) There are existing guys at the westerly corner on Highway 30
which overlap the easement which is to be relocated. An easement
will be required for those guys which will remain. This easement
can either be shown on this replat or be covered by Separate
Instrument.
(3) Either a Letter of Guarantee or construction drawings for
the sewer line to serve Lots 5 & 6 must be received and approved
by the Engineering Department prior to placing this plat on the
City Council agenda (legal notification scheduled to be taken to
THE EAGLE on Monday, August 11th). If this sewer line is located
in the easement, the width of the easement must be at least 20
feet, and must extend through Lots 3 & 4 to Rhett Butler Drive.
(4) A joint access easement must be located between Lots 1 &2
(zoned C -N) and run along Rhett Butler Drive and Highway 30.
There is a possibility that this easement can be located within
the 45 foot gas easement. Check with Lone Star Gas Company.
(5) On Lot 5 there are guys located for utility lines. An
1
Presub 86 -209
8 -6 -86
page 2
easement to accommodate these guys must be shown. This can be
covered within the 20 foot sewer easement.
*Any changes to an approved plat must be cleared through the
Planning Department.
SUBMIT FILM POSITIVE AND 10 COPIES OF REVISED PLAT TO PLANNING
DEPARTMENT PRIOR TO NOON ON FRIDAY, AUGUST 15TH TO BE INCLUDED ON
P &Z AGENDA AUGUST 21ST.
6