Loading...
HomeMy WebLinkAboutseptember 19 City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 September 19, 1984 PRESUBMISSION CONFERENCE MEMORANDUM TO: Donald D. Garrett, 4444 Carter Creek Suite 108, Bryan, TX 77802 David B. Lewis, 2902 Broadmoor, Bryan, TX 77802 FROM: Development Staff: Al Mayo, Director of Planning David Pullen, City Engineer Bill Riley, Water & Sewer Superintendent Jim McCord, Elec. Power Engrs. Joe Guidry, Electrical Superintendent Harry Davis, Fire Marshal Jane Kee, Zoning Official Cathy Locke, City Attorney Shirley Volk, Planning Technician SUBJECT: Preliminary Plat - David B. Lewis Subdivision - 84 -311 A Presubmission Conference was held on this date to review the above mentioned plat, and staff recommends approval with the following conditions: (1) Street offset as shown is not acceptable. Staff recommends Kelli Street is aligned with the location of the proposed street which may cross the Kirkpatrick property. (2) Staff recommends Kelli Street to have a 60 foot R.O.W. rather than the required 50 foot R.O.W, due to the traffic generation planned for this subdivision. (3) Show all lot dimensions. (4) Staff cannot recommend approval of the size /shape of Lot 3B Block 2 as shown, as it does not meet the minimum depth requirement for duplex development. Either redesign the lot or purchase additional property to make this lot conform to requirements. (5) A 20 foot utility easement is required across the rear of lots in Block 1 and Block 2. Electrical Department will check to see of an easement will be required between Lot 2B Block 1 and Lot 1A Block 2. (6) Extend utility easements along the north and south property lines. (7) The cleanout terminations must end with manholes. (8) Sewer service locations have been missed to Lots lA & 1B Block 2. (9) Check the survey calls of the adjacent subdivisions. There appears to be discrepancies. (10) Correct the drafting error regarding the 18" R.C.P. crossing Cornell Drive. (11) Suggest designation of a 20 foot private drainage easement in the area called "detention area" along Lot lA Block 2. SUBMIT 10 COPIES OF REVISED PLAT (AND A REPRODUCEABLE) TO PLANNING DEPARTMENT PRIOR TO 5 P.M. SEPTEMBER 28th TO BE INCLUDED ON P &Z AGENDA OCTOBER 4th. sjv ‘ei City of College Station P OST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 September 19, 1984 MEMORANDUM TO: Arthur D. Steinberg, Steinberg /Wallace & Associates, Inc. AIA 2000 Bering Drive Suite 875, Houston, Texas 77057 Jim Suttles Interests, 5151 San Felipe, Suite 1340, Houston,TX 77056 FROM: Project Review Committee: Al Mayo, Director of Planning David Pullen, City Engineer Celia Stallings, P &Z Representative Others attending: Harry Davis, Fire Marshal Jane Kee, Zoning Official Bill Riley, Water & Sewer Department Jim McCord, Elec. Power Engrs. Joe Guidry, Electrical Superintendent Rick Ploeger, City Forester Cathy Locke, City Attorney Kim Johnson, Ass't. Zoning Official Shirley Volk, Planning Technician Bob Epps, Ass't. Director of Public Services SUBJECT: Site Plan Permit - Monticello Apartments - 84 - 505 The P.R.C. met on this date to review the above mentioned project, and recommends approval with the following conditions (1) Compliance with the P.R.C. Drainage Statement which was provided is required. (2) City Engineer has approved access locations as shown. (3) Show fire hydrant locations. Fire lanes must be designated on curbing through- out the project. (4) Show all dimensions. (5) Utility easements as designated are required (20 ft. across front along SH 30 and an area around the guys at the southwest corner of the property along SH 30). (6) Design the island adjacent to the northeast property line of Sausilito property to accommodate the utility poles and guys. (7) Correct the note regarding required parking to reflect 342 spaces required. (8) A signed Development Agreement regarding the "Office Club" building is required. Coordinate with Legal Department. (9) A minimum of 6 - 6 yard dumpsters will be required for this project. Maintain a 50 foot clear turning radius in front of dumpster locations. All locations to be approved by Dept. of Public Services. (10) Eliminate conflicting parking spaces; control can be handled by making islands which separate spaces at right angles wider. (11) Islands at the ends of parking rows must be a minimum of 9 ft. in width. (12) Landscaping plans submitted 9/19/84 have been approved. SUBMIT 8 COPIES OF REVISED PLANS TO PLANNING DEPARTMENT FOR APPROVAL PRIOR TO BEGINNING STEP I1 OF THE BUILDING PERMIT PROCESS. Any changes to an approved plan must be cleared through the Office of the Director of Planning. •