Loading...
HomeMy WebLinkAboutaugust 8 � City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 August 8, 1984 PRESUBMISSION CONFERENCE TO: E. W. Schultz, Woodcreek Joint Venture, 707 Texas Ave.,Suite 222D Larry Wells, Jerry Bishop & Associates, 1812 Welsh Suite 120 Staff Attending: Jim Callaway, Ass't. Director of Planning, Mark Smith, Ass't. City Engineer Joe Guidry, Electrical Superintendent John Dennison, Elec. Power Engrs. David Riley, GTE Jane Kee, Zoning Official Shirley Volk, Planning Technician SUBJECT: Preliminary Plat - Woodcreek Section Three - 84 -308 Staff recommends approval of the above preliminary plat with the following conditions:* (1) Show location of Faulkner Drive. (2) Change street shown as " Woodcreet" to "Woodcreek ". (3) Be aware that the sewer line on Woodcreek Drive may require a 10 foot utility easement if outside the right -of -way. (4) Storm water run off control must be addressed in accordance with P.R.C. Drainage Statement. (5) Drainage easements must be sized to contain the following: (a)pilot channel designed to self cleanse with 2 year storm; (b)secondary channel to accommodate 25 year storm; (c)maintenance access for personnel and equipment. (6) The following properties will not take vehicular access from Woodcreek Drive: Block Fifteen Lots 1,2,3 & 38; Block Seventeen Lots 1 & 14; Block Eighteen Lots 1 & 14. SUBMIT 10 COPIES OF REVISED PLAT TO PLANNING DEPARTMENT PRIOR TO 5:00 P.M. ON AUGUST 10 TO BE INCLUDED ON P &Z AGENDA AUGUST 16th. sjv ♦�� City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 -2499 August 8, 1984 PRESUBMISSION CONFERENCE TO: Larry Wells, Jerry Bishop & Associates, Inc., 1812 Welsh St., City Phyllis Hobson, Nantucket Joint Venture, Home Finder Realty, 1055 Texas Avenue, College Station, TX 77840 Staff Attending: Jim Callaway, Ass't. Director of Planning David Pullen, City Engineer S ' Mark Smith, Ass't. City Engineer Joe Guidry, Electrical Superintendent John Dennison, Elec. Power Engrs. David Riley, GTE Jane Kee, Zoning Official Shirley Volk, Planning Technician SUBJECT: Final Plat - Nantucket Phase Two Subdivision 84 -222 Staff recommends approval of this final plat as shown. sjv City of College Station POST OFFICE BOX 9960 1 101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 August 8, 1984 PRESUBMISSION CONFERENCE TO: Tim Chinn, Kling Engineering, P. 0. Box 4234, Bryan, TX W. H. Aydam, 7000 Regency Square, Houston, TX 77036 Staff Attending: Jim Callaway, Ass't. Director of Planning '�' Y� 9+ Mark Smith, Ass't. City Engineer Joe Guidry, Electrical Superintendent John Dennison, Elec. Power Engrs. Jane Kee, Zoning Official Shirley Volk, Planning Technician SUBJECT: Fountain Oaks Subdivision - A Resubdivision Final Plat of Part of Blk 1 University Oaks Section Two Subdivision (7.831 acres) (84 -220) Staff recommends approval of this resubdivision plat as shown. sjv ♦ City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE C. COLLEGE STATION, TEXAS 77840 -2499 August 8, 1984 PRESUBMISSION CONFERENCE TO: Tim Chinn, Kling Engineering, P. 0. Box 4234, Bryan, TX 77802 Staff Attending: Jim Callaway, Ass't. Director of Planning`. Mark Smith, Asst. City Engineer Joe Guidry, Electrical Superintendent John Dennison, Elec. Power Engrs. David Riley, GTE Jane Kee, Zoning Official Shirley Volk, Planning Technician SUBJECT: Final Plat - Resub, of Tract E Ponderosa Place Section Two - 84 -219 Staff recommends approval as shown, however applicant has been notified that access locations are subject to review and approval by the City Engineer at site plan review. There appears to be a problem with access to the lot with only 118 feet of frontage. A minimum of 200 feet spacing is needed between drives. Check existing and site plan. The applicant needs to verify that the existing building on the new Lot E -3 complies with all setback requirements. If the setback required by ordinance of 72 feet has not been met on the existing building, the building must be located on the line line with the proper fire walls. If this building is located on the lot line, the adjacent building must be located either on the lot line, or 15 feet away from the lot line. sjv ♦�� City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 -2499 August 8, 1984 MEMORANDUM TO: Bank- 0-Property, ATTN: Ed Bravenec, 2600 Citadel, Suite 645, Houston Merliss & Jones AIA, 5010 Dincans, Houston, TX Tim Chinn, Kling Engineering, P. 0. Box 4234, Bryan, TX FROM: Project Review Committee: Jim Callaway, Ass't. Director of Planning Mark Smith, Ass't. City Engineer Steve Hansen & Celia Stallings, P &Z Representatives Other Staff: Harry Davis, Fire Marshal Joe Guidry, Electrical Superintendent Bob Epps, Ass't. Director of Public Services John Dennison, Elec. Power Engrs. David Riley, GTE Rick Ploeger, City Forester Jane Kee, Zoning Official Shirley Volk, Planning Technician SUBJECT: Site Plan Permit - Fountain Court Apartments - 84 -504 The P.R.C. met on this date to review the above mentioned project, and recommends approval with the following conditions:- (1) Include a note on the site plan indicating the second stories of buildings are connected with the breezeway on the ground floor level only. (2) Site, grading and drainage plans must be included in the set of plans sub- mitted with application for building permit. P.R.C. Drainage Statement provided; compliance required. (3) Fire hydrants must be located within 300 feet of all parts of all buildings as the hose lays. Locations of any additional hydrants and /or easements to be determined by the City Engineer (David Pullen) and shown on the final site plan. Fire hydrants must be operable prior to any construction of any com- bustible materials. (4) Show all setback dimensions, All members of P.R.C. have agreed that rear setbacks must be a minimum of 15 feet from the property line. (5) Maintain a minimum of a 15 foot setback from the centerline of power lines to any building line. (6) Blanket easements are required for underground utility service. (7) Interior drive curbing must be marked as Fire Lanes. (8) Furnish electrical load analysis to Electrical Department in construction documents. (9) Submit an accurate landscape plan showing all species, sizes and accurate point totals with the revised site plans. Compliance with the Landscape Ordinance (Ord. 1505) is required. Show the location of sprinklers or hose bibs on site /landscaping plans. (10) Re: Dumpsters (a)At least 4 - 6 yard dumpsters are required for this project. Continued on page 2 P.R.C. (84 -504) 8 -8 -84 page 2 (b)Spaces for dumpsters must be a 12'x 20' minimum, (c)Angle dumpster locations as directed by the Assistant Director of Public Services maintaining a 50 foot clear radius in front of the dumpsters. (11) Show dimensions of drive accessways and the radii, (12) A11 islands must be a minimum of 9 feet in width; show dimensions of all islands. (13) Any density above 24 dwelling units per acre is subject to approval by the City Council. Upon receipt of revised, approved site and landscaping plans, same will be forwarded to City Council for action. SUBMIT 8 COPIES OF REVISED SITE /LANDSCAPING PLANS TO PLANNING DEPARTMENT FOR REVIEW AND APPROVAL, THESE PLANS WILL BE FORWARDED TO CITY COUNCIL FOR ACTION REGARDING DENSITY. AFTER APPROVAL, STEP II OF THE BUILDING PERMIT PROCESS CAN BEGIN. Any changes to an approved site plan must be cleared through the Office of the Director of Planning, sjv