January 18, 1984
MEMORANDUM
TO: Planning and Zoning Commission
John Olsen (Bishop & Assoc.) and Wm, Grant Riley, Jr. (Rep.of App.)
FROM: Project Review Committee:
Al Mayo, Director of Planning Y
David Pullen, City Engineer
E. Murl Bailey, P &Z Representative
SUBJECT: Site Plan Permit - Eastmark Apartments - 84
The P.R.C. met on this date to review the above mentioned project, and recommends
approval with the following conditions:*
(1) Compliance with PRC Drainage Statement provided is required,
(2) Curb cuts to Southwest Parkway are not allowed. Access will be taken to
lesser streets,
(3) Interior water distribution systems must be designed and constructed under
supervision of a Registered Professional Engineer; plans for same must be
approved by the City Engineer.
(4) Fire hydrants must be located within 300 feet of all parts of all buildings
as the hoses lay.
(5) Four (4) dumpster pads will be required, each to hold a 6 cubic yard dumpster.
Maintain a 50 ft. clear radius in front of each pad. Screening fences without
gates should be included on plans. Location of dumpster pads to be approved
by Department of Public Services.
(6) All curbing except that which is in front of designated parking spaces must
be marked as Fire Lanes.
(7) Ten (10) foot utility easements are required on this property at locations
designated by the Electric Department. Meters will be ganged at one location
on each building.
(8) Include groundcover notes in legend for convenience only.
(9) A 6" raised curb Is requried around all edges of all parts of all paved areas
without exception, (To include islands, planting areas, access ways, dumpster
locations, utility pads, etc.) Curb detail to be approved by the City Engineer.
No exceptions will be made for areas indicated on site plan as "reserved for
future parking ".
(10) All signs must comply with Zoning Ordinance. Confer with Zoning Official
regarding regulations.
*Any changes to the approved site plan must be cleared through the office of
the Director of Planning.
SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY 5:00 P.M. January 27th
TO BE INCLUDED ON PAZ AGENDA February 2nd.
Other Staff Attending: Jim McCord, Joe Guidry, Bob Epps, Joey Porter,
sjv John Goff (GTE) and Shirley Volk.
City of College Station
POST OFFICE BOX 9960 1 101 TEXAS AVENUE
Cf COLLEGE STATION, TEXAS 77840 -2499
January 18, 1984
MEMORANDUM
TO: Planning and Zoning Commission
Tad Vaughn
FROM: Project Review Committee:
Al Mayo, Director of Planning
David Pullen, City Engineer
E. Mur1 Bailey, P &Z Representative
Other Staff:
Jim McCord, Elec. Power Engrs.
Joe Guidry, Electrical Superintendent
Joey Porter, Fire Department
Bob Epps, Asst, Director of Public Services
John Goff, GTE
Shirley Volk, Planning Technician
Jim Callaway, Ass't. Director of Planning
SUBJECT: Conditional Use Permit - Twin City Church of Christ - 84 -701
The P.R.C. met on this date to review the above mentioned project, and recommends
approval with the following conditions:*
(1) Include a location map on site plan.
(2) No dumpster required; trash can be handled by bags on curb,
(3) A 50 ft, radius of paved area (designated as a Fire Lane) must be provided
which will allow emergency vehicles to turn around; alternative can be a
20 foot driveway which goes completely around the rear of the building and
connects the parking areas.
(4) PRC recommends additional landscaping for project,
(5) Compliance with PRC Drainage Statement which has been provided is required.
(6) Sprinkler systems are required in buildings for assembly occupancy over
5000 square feet.
(7) Required utility easements must be conveyed by Separate Instrument.
(8) Electric service should come from the east side of the property line. A
10 foot utility easement will be required on this side of that property line.
(9) A 6" raised curb is required around all edges of all parts of all paved areas
without exception. (To include islands, planting areas, access ways, dumpster
locations, utility pads, etc.) Curb detail to be approved by the City Engineer.
No exceptions will be made for areas indicated on site plan as "reserved for
future parking ".
*Any changes to the approved plan must be cleared through the office of the
Director of Planning.
SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY 5:00 P,M, ON FEBRUARY 10th
TO BE INCLUDED ON P &Z AGENDA FEBRUARY 16th.
sjv
♦' City of College Station
POST OFFICE BOX 9960 1101 TEXAS AVENUE
\ / COLLEGE STATION, TEXAS 77840 -2499
January 18, 1984
MEMORANDUM
TO: Planning and Zoning Commission
John Olsen (Bishop & Associates) & Jerry Theis Associates, Inc.
FROM: Project Review Committee:
Al Mayo, Director of Planning
David Pullen, City Engineer
E. Murl Bailey, P &Z Representative
SUBJECT: Parking Lot Plan (Revised) - Texian Inn (Motel) 84 -400
The PRC met on this date to review the revised site plan for the above men-
tioned project, and recommends approval with the following conditions:`
(1) Show the dimensions of curb cuts off Meadowland.
(2) Fire Department requires a 14 ft, clearance under the canopy.
(3) Dumpster location as shown is approved; project will require a minimum
of 1- 6 cubic yard dumpster.
(4) An additional fire hydrant is required by the Fire Department at the
location designated in the review meeting.
(5) Relocate the existing fire hydrant to the north side of the driveway.
(6) The screen fence must be on the property line.
(7) Show the width of the drive on the south side of the island by the canopy.
(8) Relocate parking spaces numbered 117 and 118.
(9) Redesign the driveway transition to the south side of the canopy.
(10) All curbing should be marked as Fire Lane,
(11) Identify all plants on the landscape plan, which if approved, will become
the final landscape plan.
(12) Identify groundcover and the application planned,
(13) A 6" raised curb Is required around all edges of all parts of all paved
areas without exception. (To include islands, planting areas, access ways,
dumpster locations, utility pads, etc.) Curb detail to be approved by the
City engineer. No exceptions will be made for areas indicated on site plan
as "reserved for future parking ".
(14) Compliance with PRC Drainage Statement is required.
*Any changes to the approved plan must be cleared through the office of the
Director of Planning.
SUBMIT 10 COPIES OF REVISED SITE PLAN TO PLANNING DEPARTMENT BY 5:00 P.M. on
January 27th TO BE INCLUDED ON P &Z AGENDA FEBRUARY 2nd.
sjv Other Staff Attending: Jim McCord, Joe Guidry, Bob Epps, Joey Porter,
John Goff (GTE) and Shirley Volk.