HomeMy WebLinkAboutnovember 23 ce City of College Station
P OST OFFICE BOX 9960 1 101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840 -2499
November 23, 1983
MEMORANDUM
TO: Planning and Zoning Commission
Ruel Nash, Robert K. Nash, Gary Schuberth, Raymond Ochoa
and John Olsen
FROM: Project Review Committee:
Al Mayo, Director of Planning
Mark Smith, Ass't. to City Engineer
Murl Bailey, PAZ Representative
Other Staff:
Jane Kee, Zoning Official
Bob Epps, Ass't. Director of Public Services
Jim McCord, Elec. Power Engrs,
Shirley Volk, Planning Technician
SUBJECT: College Station Retail Center - Parking Lot Plan - 83 - 452
The P,R.C. met on this date to review the above mentioned plans and recommends
approval with the following conditions:%
(1) The curb cut on Texas Avenue closest to the Highway 30 intersection must
be redesigned as instructed, using a larger radius than shown on the
northern side. Approval will be regulated by the City Engineer.
(2) Two curb cuts on Park Place will not be allowed. Combine the two
shown into one larger curb cut; up to 30 ft. in width will be allowed.
(3) Maintain a minimum 8 ft. setback from the property line. Show that
dimension on the site plan.
(4) Show a grading /drainage plan.
(5) Show the flood plain on the site plan. An elevation certificate is
required prior to C.0,
(6) Show the fire hydrant location. All parts of all buildings must be within
300 ft. of a hydrant as the hose lays. If an additional hydrant is necessary,
easements for that water line will be required. Show on plan.
(7) Show all utility easements (as relocated for platting) on site plan.
(8) Show the dimensions of all driveways, islands, sidewalks, etc. The
center island which will be used for overhand for cars must be a minimum
of 4 ft. in width (2 ft. for each car).
(9) A 6" raised curb is required around all edges of all parts of all paved areas
without exception. (To include islands, planting areas, access ways, dumpster
locations, utility pads, etc.) Curb detail to be approved by City Engineer.
No exceptions will be made for areas indicated on site plan as "reserved for
future parking".
Continued.,.
P.R.C. Memo - 83 -452
11 -23 -83
page 2
(11) Dumpster pads must have a minimum of 12'x12' interior measurements allowed.
Dumpster should be directional, facing the northwest, and located immediately
behind the building away from the utility connection.
(12) Please take the sod up to a point on the creek bank where the creek breaks.
(13) Include complete landscaping plans, either on site plan or on a separate
plan. The landscaping approved by the P &Z Commission will be required at
time of issuance of C.O.
(14) Leave an opening in the landscaping adjacent to the drainage easement to
allow ingress and egress of maintenance equipment necessary to work at the
creek,
(15) Check with the Fire Marshal and the Building Official concerning firewalls
and /or sprinkler systems. Any assembly area 5000 sq. ft. or over must be
sprinklered,
(16) Development agreement to be supplied by the time the building permit is
applied for.
(17) P.R.C. drainage statement supplied at P.R.C. review; this must be complied
with.
SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY DECEMBER 9th TO BE
INCLUDED ON DECEMBER 15th P &Z AGENDA.
*Any changes to an approved site plan must be cleared through the office of the
Director of Planning.
Please refer to the enclosed brochure covering P &Z Commission meetings.
sjv
♦�� City of College Station
POST OFFICE BOX 9960 1101 TEXAS AVENUE
\ / COLLEGE STATION, TEXAS 77840 -2499
November 23, 1983
MEMORANDUM
TO: Planning Flies
Philip Blackburn & Bill Alford
FROM: Project Review Committee VI" Al Mayo, Director of Planning
Mark Smith, Asst. to the City Engineer
Murl Bailey, P &Z Representative
Other Staff:
Jane Kee, Zoning Official
Bob Epps, Ass't. Director of Public Services
Jim McCord, Elec. Power Engrs.
Shirley Volk, Planning Technician
SUBJECT: Parking Lot Plan - P.M. Lubrication Center - 83 -451
The Project Review Committee met on this date to review the above mentioned
site plan and recommends approval with the following conditions:*
(1) Move the center curb cut (on Texas Avenue) down and eliminate the small
curb cut on the north end of the project. An access way of 44 ft. in
width will be allowed In the approximate center of the tract. Use a
25 ft. radius for this curb cut.
(2) Show the flood plain on the site plan. Include a note concerning the
finished floor elevation. An elevation certificate will be required
before issuance of the C.O.
(3) Show caliper size of trees (11" minimum).
(4) Show that sodding will be "solid sod ".
(5) Show size of crape myrtles as 5 gallon.
(6) Standard P.R.C. drainage statement provided at time of review; compliance
required.
(7) Do not encroach the adjacent property with the radius of the curb cuts.
(8) A 6" raised curb Is required around all edges of all parts of all paved
areas without exception. (To include islands, planting areas, access ways,
dumpster locations, utility pads, etc.) Curb detail to be approved by the
City Engineer. No exceptions will be made for areas indicated on site plan
as "reserved for future parking ".
(9) A fire hydrant must be within 300 ft. of all parts of all buildings as the
hose lays. Check with Fire Marshal concerning location. Approval from
Fire Marshal must be made prior to issuance of building permit.
Continued...
P.R.C. Memo - 83 -451
11 -23 -83
page 2
(10) Dumpster angle and location to be approved by Director of Public Services.
Suggestion was made to shift the shown dumpster 90o to face the street, and
also to move that pad back 12 ft. Do not put up any gates. Elevation of
minimum 12'x12 ft. pad to be the same as the pavement.
(11) A 6' screen fence Is required between this project and the adjacent residential
area.
(12) One detached sign will be allowed on this entire tract.
(13) Show the utility poles on this site plan.
SUBMIT 4 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT FOR REVIEW PRIOR TO
ISSUANCE OF BUILDING PERMIT.
*Any changes to the approved plan must be cleared through the Office of the
Director of Planning.
sjv
Ca/ i f lleg a i0 POST OFFICE BOX 99 1101 TEXAS AVENUE
/ COLLEGE STATION, TEXAS 77840 -2499
November 23, 1983
PRESUBMISSION CONFERENCE
John Olsen, Jerry Bishop & Associates, Inc.
Attending: AI Mayo, Director of Planning
Mark Smith, Asst. to City Engineer
Jane Kee, Zoning Official
Bob Epps, Ass't. Director of Public Services
Shirley Volk, Planning Technician
Jim McCord, Elec. Power Engrs.
SUBJECT: Final Plat - Vac. & Resub. Lots 1,2,3,5R & 6 Block Two F.S.Kapchinski
(83 - 245)
The above plat was reviewed at a Presubmission Conference held on this date
and staff recommends approval with the following conditions:`
(1) The plat will not be approved until plans for the relocation of utility
easements have been received and approved by the City Engineer, and until
the easements themselves are received and approved by the City Engineer.
(2) The configuration of all required drainage easements and drainage R.O.W's
shall provide sufficient area for the 100 year flow and channel maintenance
activities as approved by the City Engineer prior to the filing of the plat.
(3) Lot 6R must have a minimum width at any point of 24 ft.
(4) A minimum 10 ft. utility easement for electric service will be required on
either side of the property line between Lot IR and Lot 6R. Electric lines
must be kept 15 feet from any building. Staff recommends that utility
easements be located as follows: 10 ft. on Lot 6R (the west side of the
common property line) continuing to and including to a location 5 ft. east
of and parallel to the existing sewer line.
(5) Show the flood plain on this plat.
SUBMIT 10 COPIES OF REVISED PLAT TO PLANNING DEPARTMENT BY DECEMBER 6th TO BE
INCLUDED ON P &Z AGENDA DECEMBER 15th.
`Any changes to an approved plat must be cleared through the Office of the
Director of Planning.
Please refer to attached brochure concerning P &Z Commission meetings.