Loading...
HomeMy WebLinkAboutoctober 12 ♦�� City of College Station POST OFFICE BOX 9960 1 101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 October 12, 1983 MEMORANDUM - PRESUBMISSION CONFERENCE Attending: Al Mayo, Director of Planning j Harry Davis, Fire Marshal David Pullen, City Engineer Jane Kee, Zoning Official Dan Dupies, Ass't Zoning Official Joe Guidry, Electrical Superintendent Bennie Luedke, Water & Sewer Superintendent Jim McCord, Elec. Power Engrs David Riley, GTE Tony Jones, Applicant & Owner Larry Wells & John Olsen, Jerry Bishop & Assoc. Shirley Volk, Planning Technician SUBJECT: Final Plat - T. J. Addition - (83 - 239) A presubmission conference was held on this date to review the above mentioned plat, and staff recommends approval with the following conditions:* (1) Additional 10 ft. of right -of -way is required along Sebesta Road to accommodate future widening of this street. (2) Additional 10 ft.utility easement required along Sebesta Road, along the east property line and along the East Bypass. (3) One shared access point to serve both lots will be allowed to the Frontage Road. This access must be a minimum of 200 feet from the intersection. A joint access easement can be shown on the plat to accommodate a drive to be specifically located at a later date. (4) Any private access easements should be shown on this plat. PROVIDE 10 COPIES OF REVISED DRAWING TO PLANNING DEPARTMENT BY 5:00 P.M. ON FRIDAY, OCTOBER 14th TO BE INCLUDED ON P &Z AGENDA OCTOBER 20th. sjv Any changes to the approved plat must be cleared through the office of the Director of Planning. No public comment will be received at Commission meeting unless requested by a member of the Commission and allowed by the chairman. Applicant may submit any written comment to the Commission by filing same on the Friday preceding the scheduled meeting. City of College Station POST OFFICE BOX 9960 1 101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 October 12, 1983 MEMORANDUM TO: David Gower FROM: Project Review Committee: Al Mayo, Director of Planning David Pullen, City Engineer Gerald Miller, P &Z Representative Other Staff: Bennie Luedke, Superintendent Water & Sewer Harry Davis, Fire Marshal Jane Kee, Zoning Official Joe Guidry, Electrical Superintendent Dan Dupies, Ass't Zoning Official Jim McCord, Elec. Power Engrs. Bob Epps, Rep. of Dir, of Public Services David Riley, GTE Shirley Volk, Planning Technician SUBJECT: Site Plan Permit - 4- plexes at 1801 Treehouse - 83 -514 The P.R.C. met on this date to review the above mentioned project, and recommends approval with the following conditions:* (1) Redraw on 24 "x36" paper. (2) Consult City Engineer concerning the drainage easement and the fence shown. (3) The front area between the parking and the street (referred to in notes as "Front Parking Planter Area should be bermed. Show height of berm. (4) Landscape notes should include type or species of shrub; change one gallon shrubs to two gallon size and indicate species; show caliper and species of evergreen trees; juniper bushes should be shown in gallon size; indicate species and size of plants in planter area; and indicate type of groundcover which is to be hydromulched. (5) All unpaved areas are to have groundcover. (6) If existing trees are shown on the site plan and they do not survive, they must be replaced by regulations in governing ordinance. (7) Addition of a 4 ft. deep "turnaround" in front of building is required to facilitate movement of vehicles. (8) A 6" raised curb is required around all edges of all parts of all paved areas without exception. Curb detail to be approved by the City Engineer. SUBMIT CORRECTED SITE PLAN PRIOR TO BUILDING PERMIT APPLICATION. sjv *Any changes to the approved site plan must be cleared through the Office of the Director of Planning. CA City of College Station P OST OFFICE BOX 9960 1 101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 October 13, 1983 MEMORANDUM TO: Planning and Zoning Commission W. A. McKean & Steve Hansen FROM: Project Review Committee: Al Mayo, Director of Planning k David Pullen, City Engineer Gerald Miller, P &Z Representative Others Attending: Bennie Luedke, Water & Sewer Superintendent Harry Davis, Fire Marshal Jane Kee, Zoning Official Joe Guidry, Electrical Superintendent Dan Dupies, Ass't Zoning Official Jim McCord, Elec. Power Engrs. Bob Epps, Rep. of Dir. of Public Services David Riley, GTE Shirley Volk, Planning Technician SUBJECT: Parking Lot Plan - 83 -443 - REVISED PLAN FOR WELSH OFC. BUILDING FOR JAN -WIC HOMES, INC. The P.R.C. met on October 12th to review the as -built plan (see 82 -416) which the P &Z had previously denied, and to review a proposed plan, which combines the as -built with an additional building. Al Mayo, Director of Planning and Gerald Miller, P &Z Representative each indicated at this meeting that they are not willing to settle for the 4 ft. setback which is on the ground, but believe the setback should be changed to the 8 ft. setback which ordinance requires, and which had been required at previous meetings held prior to construction of the project. If the Planning and Zoning Commission determines it is willing to accept the 4 ft. setback as it is already built, then the Project Review Committee recommends the following conditions prior to approval:* (1) Show the actual driveway dimension, allowing for cars parked in the angled spaces, noting that there will be overhang of cars into the drive area. (2) Mark a fire lane at the rear of the buildings. Drive must be 20 ft. in rear. (3) Areas shown as yellow striping should be curbed and included as part of islands. (4) Parking spaces in rear of buildings should have islands at ends of parking spaces, rather than shown striping. (5) Dumpster location as shown is acceptable if it has no gates. (6) Required parking for the two buildings as shown is 60 spaces plus spaces for ...continued P.R.C. memo - 83 -443 10 -13 -83 page 2 employee parking. Total parking available is 64 spaces which would accommodate only 8 employees for both buildings. Additional spaces should be provided, or building should be made smaller. (7) Landscaping: Show size and type of trees. Show type and application planned for groundcover. SPECIAL NOTE: The entire project is being considered under this case number, which includes both the existing building and the proposed building. The shaded part of the site plan shows the existing building and parking lot, as it is built. (8) A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, utility pads, etc.) Curb detail to be approved by the City Engineer. No exceptions will be made for areas indicated on site plan as "reserved for future parking ". NOTE TO APPLICANT: No public comment will be received at Commission meeting unless requested by a member of the Commission and allowed by the chairman. Applicant may submit any written comment to the Commission by filing same on the Friday preceding the scheduled meeting. Any changes to the approved plan must be cleared through the office of the Director of Planning. SUBMIT 10 COPIES OF REVISED SITE PLAN TO PLANNING DEPARTMENT BY 5:00 P.M. ON FRIDAY, OCTOBER 14th TO BE INCLUDED ON P &Z AGENDA OCTOBER 20th. sjv City of College Station POST OFFICE BOX 9960 1 101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 October 13, 1983 MEMORANDUM TO: Planning and Zoning Commission Don Mills, 1216 Two Turtle Creek Village, Dallas Len Mills, 5924 Royal Lane Suite 168, Dallas W. A. McKean & Steve Hansen, JanWic Homes, Inc. FROM: Project Review Committee: Al Mayo, Director of Planning ∎ David Pullen, City Engineer Gerald Miller, P &Z Representative Others Attending: Bennie Luedke, Water & Sewer Superintendent Harry Davis, Fire Marshal Jane Kee, Zoning Official Joe Guidry, Electrical Superintendent Dan Dupies, Ass't Zoning Official Jim McCord, Elec. Power Engrs. Bob Epps, Rep. of Dir. of Public Services David Riley, GTE Shirley Volk, Planning Technician SUBJECT: Parking Lot Plan - Wendy's Old Fashioned Hamburgers - (83 -444) The P.R.C. met on the above date to review the subject project, and recommends approval with the following conditions:* (1) Show the 8 ft. setback off the property line along Southwest Parkway. (2) Any detached sign is pending ZBA action, and results should be available by the P &Z Commission meeting. (3) Show the telephone lines on the site plan. (4) Furnish a letter to the Electrical Department requesting underground service. (5) Driveway must be a minimum of 20 ft. in width on this property. (6) Show dimensions on all islands. (7) Handicapped parking spaces are required following regulations of Building Code. (8) Revise landscaping to meet ordinance requirements; show type and application of grass; show type of bushes and indicate sizes in "gallon" size; all trees to meet ordinance requirements. At time of review, Lot 4 was planned to be paved and landscaped. (9) Drainage plans will be included on the Master Drainage Plan which covers all of the Ashford Square Subdivision. SUBMIT 10 COPIES OF THE REVISED PLAN TO THE PLANNING DEPARTMENT BY 5:00 P.M. on FRIDAY, OCTOBER 14th TO BE INCLUDED ON P &Z AGENDA OCTOBER 20th. *Any changes to the approved site plan must be cleared through the office of the Director of Planning. ...continued P.R.C. Memo - 83 -444 10 -13 -83 page 2 No public comment will be received at the Commission meeting unless requested by a member of the Commission and allowed by the chairman. Applicant may submit any written comment to the Commission by filing same on the Friday preceding the scheduled meeting. (10) A 6" raised curb is required around all edges of all parts of all parking areaa; private access easements will not be curbed. sjv