Loading...
HomeMy WebLinkAboutjanuary 4 (1 City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 January 4, 1983 PRESUBMISSION CONFERENCE Attending: Al Mayo, Director of Planning David E. Pullen, City Engineer Joe Porter, Rep. of Fire Marshal Joe Guidry, Electrical Superintendent Jim McCord, Elec. Power Engr. Bill Cupp, GTE Allen R. Swoboda Larry Wells, Jerry Bishop & Assoc. Shirley Volk, Planning Technician SUBJECT: Final Plat - Emerald Forest Phase Seven (83 -200) Staff recommends approval with the following changes:* (1) Sebesta Road will dead end at Sandstone. Remove lettering which indicates a possible extension. (2) Delete 10 ft. "Reserve for future R.O.W. dedication" along property line of Lots 5 -18 Block Five. (3) Add notes concerning access to lots along Emerald Parkway indicating these lots will take access elsewhere, and not from Emerald Parkway. (4) A private access along Lot 5 Block Five which will give access to the lots across the property line in Phase Five will be acceptible if the length remains in conformance with Subdivision Regulations. (5) Show a side building line on Lots 4 & 5 Block Five. (6) The 10 ft. utility easement along the rear property lines of Lots 5 -18 Block Five should be increased to 20 ft. (7) Final approval of the drainage easement must be made by the City Engineer after results of a study concerning required width and best method to handle drainage are obtained. Any changes to the appr.wed plat must be cleared through the Office of t:'e Director of Planning. SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY 5 P.M. FRIDAY JANUARY 14th TO BE INCLUDED ON P &Z AGENDA JANUARY 20th. sjv Cf ♦�� City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 -2499 January 4, 1983 PRESUBMISSION CONFERENCE Attending: Al Mayo, Director of Planning David E. Pullen, City Engineer Joe Porter, Ass't to Fire Marshal Joe Guidry, Electrical Superintendent Jim McCord, Elec. Power Engr. Bill Cupp, GTE Joe Blaschke, Walton & Associates cc: Mike McClure Tony Caporina Shirley Volk, Planning Technician SUBJECT: Final Plat - Woodway West Phase I Staff recommends approval with the following changes:- (1) Include a note to indicate this is a "Final Plat ". (2) Show access easements across the sides of Lots 1 & 16. (3) Show the temporary "turnaround" on Sienna Drive. (4) Utility easement will be necessary along Lot 1 if easement is not provided along abandoned RR R.O.W. (5) Change the "30 ft. bldg. setback, private access & utility easement" to show "20 ft. private access and 10 ft. Utility easement" inside the property line with an additional 10 ft. utility easement outside the property line (to be handled by Separate Instrument at a later date). (6) Staff recommends approval of Plat, but further recommends Plat should not be filed until conditions set down previously are met. -`Any changes to the approved plat must be cleared through the Office of the Director of Planning. SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY 5 P.M. FRIDAY JANUARY 14th TO BE INCLUDED ON P &Z AGENDA JANUARY 20th. sjv Cf City o f College Station P OST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 January 4, 1983 MEMORANDUM TO: Planning & Zoning Commission Equity Development Co. (Wm. H. Glans) cc: C. Leon Williamson, Architect FROM: Project Review Committee Al Mayo, Director of Planning David Pullen, City Engineer Jim Behling, Chairman P &Z Other Staff: Jane Kee, Zoning Official Dan Dupies, Ass't Zoning Official Joe Guidry, Electrical Superintendent Jim McCord, Elec. Power Engr. Bill Cupp, GTE Joe Porter, Ass't to Fire Marshal (called away prior to completion of review) Shirley Volk, Planning Technician SUBJECT: PARKING LOT PLAN - Retail Center for Equity Development - (83 -400) located at Anderson & Holleman The P. R. C. met on January 4, 1983 to review the above mentioned project, and recommends approval with the following conditions:* (1) Include Vicinity Map. (2) Show proposed water and sewer lines which must be approved by Bennie Luedke and David Pullen. (3) Close curb cut (existing) off Holleman nearest Anderson. (4) Suggest remaining curb cut off Holleman be reduced to 30 ft. in width and locate an island around the power pole (existing). Island to have 6" raised curb. (5) Curbs into service drive need to be reworked to provide turning radius which will accommodate large trucks (including garbage trucks). Islands within the service drive must also be reworked for the same purpose. (6) Utility Departments require a 20 ft. utility easement from the existing pole which services the existing building housing the Hair Design and Pizza Rest. to a point where an additional pole will be placed which will service Building A. Easement may be dedicated by Separate Instrument. (7) Location of dumpster subject to approval by Mac Allen. (8) Add a note showing a 6" raised curb around the entire parking area. Also show where curb will be behind dumpster. (9) Show the dimensions on the service drive between the fence next to the existing building and building A. Drive must be at least 23 ft., plus 18 ft. parking space, plus a 2 ft. overhang, allowing a total of 41 ft. between that fence and the 6" raised curb which will serve as a wheel stop, plus the 2 ft. overhang. (83 -400) P.R.C. continued 1 -4 -83 page 2 (10) 6" raised curbing should be run 2 ft. off property line where there is head -in parking. Said curb can be used as wheel stop. (11) Show a typical dimension of a parking space (9'x18' plus 2 ft. overhang). SUBMIT 10 COPIES OF REVISED PLAN TO THE PLANNING DEPARTMENT BY 5:00 P.M. JANUARY 14th TO BE INCLUDED ON P &Z AGENDA JANUARY 20th. Any changes to the approved plan must be cleared through the Office of the Director of Planning. sjv