Loading...
HomeMy WebLinkAboutJune 11C% June 11, 1986 MEMORANDUM City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 -2499 TO: Russell Bradley, DDS, 209 Dominik, College Station, TX 77840 Greg Simmons, P, 0. Box 2602, Bryan, TX FROM: Project Review Committee: VA- ,,, J Ai Mayo, Director of Planning David Pullen, City Engineer Walter Wendler & Steve Stewart, P&Z Representatives Others attending: Carol Elmore, Assistant City Attorney Jimmy McCord, McCord Engineering, Inc. Kim Johnson, Assistant Zoning Official Ray Havens, Acting Electrical Superintendent Harry Davis, Fire Marshal Shirley Volk, Planning Technician SUBJECT: Parking Lot Plan - Addition to existing dentist office at 209 Dominik (86 -412) The P.R.C. met on this date to review the above mentioned project, and approved the project with the following conditions*: 1, Furnish electrical load data requirements to Electric Department. 2, Place some type of temporary curbing along the western property line from the sidewalk at rear of building to rear property line. 3. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be approved by the City Engineer, No exceptions will be made for areas indicated on site plan as "reserved for future parking ". 4. Reverse location of islands in the rear of proposed addition from west side of property to east side. 5. Parallel parking spaces should be a minimum of 22 ft. in length. 6. The P.R.C. recommended that the applicant secure an access easement from the owner of the shopping center adjacent which would guarantee access to the parking spaces in the rear of the proposed office. 7. The Fire Marshal stated that guaranteed access to the rear of the building Is crucial to the Fire Department, therefore is required. 8. Minimum landscaping point requirement for this project is 500 points, 250 of which must be in canopy trees. Recalculate landscaping for this project and include a table as required by Zoning Ordinance. 9. Locate and designate either irrigation or hose bibs. Designate type of groundcover to be used. 10. Show existing easements and utilities including the manhole. 11. Assistant Director of Public Services has stated that curbside garbage bag pickup Is acceptable for this project. SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT FOR APPROVAL PRIOR TO CONTINUING WITH STEP !i OF THE BUILDING PERMIT PROCESS, -Any changes to an approved site plan must be