HomeMy WebLinkAboutDecember 116 0 .40 4' City of College Station \ , POST OFFICE BOX 9960 1 101 TEXAS AVENUE / COLLEGE STATION, TEXAS 77840 -2499 December 11, 1985 MFMORANDIIM TO: Robert A. Cummins, The Castillo Co., Inca (Architect) Earl Legg, State Farm Mutual Auto Ins. Co, (Claim Supt.) Donald Garrett, Garrett Engeering, Inc. FROM: Project Review Committee Al Mayo, Director of Planning W1_11J David Pullen, City Engineer George Dresser, P &Z Representative Others attending: Bob Epps, Asst. Director of Public Services Bill Riley, Water Distribution Supervisor Jane Kee, Zoning Official Kim Johnson, Asst. Zoning Official Harry Davis, Fire Marshal SUBJECT: Parking Lot Plan - State Farm Mutual Automobile Insurance Company Service Center (85 -491) on 1,32 acre tract (Lot 3A Blk V U.P.II, a pending replat of Lot 3 Blk V U.P,II) on University Drive The P,R,C. met on this date to review the above mentioned project, and recom- mends approval with the following conditions`: (1) Dumpster pad must be a minimum of 12' x 12' interior measurement; any fencing (without gates) must go on outside of these measurements. Minimum requirement for this project is one 3 cubic yard dumpster. (2) P,R.C. drainage statement provided; compliance required. (3) The street into this project (coming off University Drive) must be a minimum of 20 feet in width to qualify for a fire lane which is necessary. Mark the curbing along this street as a fire lane. Check with Fire Marshal for required marking, (4) The driveway closest to University Drive into this project may cause a problem to the applicant in the future, but the Engineering Department has approved this location as it is proposed. (5) Engineering Department recommends a 25 foot minimum radius to the street from University Drive. (6) Relocate the water hydrant; water hydrants must be located within 10 feet of a driving surface. Coordinate location with Water & Sewer Department Superintendent Bennie Luedke. (7) The low profile sign must be located a minimum of 10 feet behind the right -of -way line and clear of the sight distance triangle. (8) Building Code requires a minimum of 3 handicap parking spaces for this project. (9) Landscaping: "Protected" trees require a 7 foot (minimum) barricade to be in place prior to any grading or clearing in order to qualify for the allotted points, Show barricade details on site plans. *Any changes to an approved site plan must be cleared through the Planning Dept. SUBMIT 10 COPIES OF REVISED PLANS FOR APPROVAL BY PLANNING DEPARTMENT PRIOR TO CONTINUING WITH STEP 11 OF THE BUILDING PERMIT PROCESS,