Loading...
HomeMy WebLinkAboutjune 6 ♦�� City of College Station POST OFFICE BOX 9960 1101 TEXAS AVENUE \ / COLLEGE STATION, TEXAS 77840 -2499 June 7, 1984 MEMORANDUM TO: Planning and Zoning Commission Andy Wisnoski, M.O.Lawrence Jr. Architects Edgar Wolferts, Church of Jesus Christ of Latter Day Saints Corporation of Church of Jesus Christ of Latter Day Saints FROM: Project Review Committee: Al Mayo, Director of Planning David Pullen, City Engineer Steve Hansen /Dan MacGilvray, P&Z Representatives Other Staff: Bob Epps, Ass't. Director of Public Services Jim McCord, Elec. Power Engrs. Joe Guidry, Electrical Superintendent Joey Porter, Ass't. Fire Marshal Jane Kee, Zoning Official Kim Johnson, Ass't. Zoning Official Shirley Volk, Planning Technician SUBJECT: Conditional Use Permit - New Building at 100 -106 Dexter Drive for Church of Jesus Christ of Latter Day Saints (84 -704) The P.R.C. met on June 6, 1984 to review the above mentioned project, and recommends approval with the following conditions-, also subject to approval by City Engineer following study of results of a Drainage Report to be prepared by the applicant: (1) Present revised site plan on 24x36 paper. (2) Show setback dimensions. Ordinance requires an 8 ft. setback from the pro- perty line to any paved area. (3) Include a Location Map. (4) Show island dimensions. Ordinance requires all islands to be a minimum of 9' x 20'. (5) Curbside trash pickup limited to 4 bags per week is approved; if more would be generated, a dumpster will be required. (6) Indicate which trees will be protected; include barrier section; show land- scaping notes in a legend; include total number of points for project and the breakdown for landscaping planned. (7) Any underground parking area must be sprinklered and also have the appro- priate fire walls required by the building codes of the City. (8) A fire hydrant must be within 300 feet of all parts of the building as the hose lays. Show the location of the nearest fire hydrant to this property. (9) P.R.C. drainage statement provided; compliance required; final site plan approval subject to results of this drainage study. (10) Any assembly class building over 5,000 sq. ft. must include a sprinkler system. (11) A 10 foot utility easement is required for the existing overhead utility line. (12) A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, dumpster Continued on Page 2 P.R.C. (84 -704) continued page 2 locations, utility pads, etc.) Curb detail to be approved by the City Engineer, No exceptions will be made for areas indicated on site plan as "reserved for future parking ". SUBMIT 10 COPIES OF REVISED PLAN TO PLANNING DEPARTMENT BY JUNE 15th TO BE INCLUDED ON PAZ AGENDA JUNE 21st. SUBMIT 1 COPY OF REVISED PLAN TO THE ELECTRICAL DEPARTMENT WHICH INCLUDES THE ELECTRIC SERVICE LOCATION FOR DESIGN AND APPROVAL. -`Any changes to an approved plan must be cleared through the office of the Director of Planning. sjv