HomeMy WebLinkAboutmarch 22 ♦�� City of College Station
POST OFFICE BOX 9960 1101 TEXAS AVENUE
\ / COLLEGE STATION, TEXAS 77840 -2499
March 22, 1984
PRESUBMISSION CONFERENCE
TO: Wick McKean, Steve Hansen, Chris Galindo, Robin Bruno,
Jim Schutt
FROM: Al Mayo, Director of Planning V i‘d
David Pullen, City Engineer
Joe Guidry, Electrical Superintendent
Bill Riley, Ass't, to Water & Sewer Superintendent
Cathy Locke, Ass't. City Attorney
Bob Epps, Ass't. Director of Public Services
Shirley Volk, Planning Technician
SUBJECT: Final Plat - Park Place (9.3162 Acres located at the corner
of Southwest Parkway & Texas Avenue - 84 -210
A Presubmission Conference was held on 3 -21 -84 to review the above men -
tioned plat, and staff recommends approval with the following conditions:*
(1) All utility easements must be a minimum of 20 feet in width with
exception of those along Southwest Parkway and Texas Avenue.
(2) Lot 2 of this plat will take access through the PPAE and will not
have access to Texas Avenue or Southwest Parkway.
(3) Extend the 65 ft, PUE at the SW corner of Lot 2 around the property
line to the NE corner of Lot 2 along Southwest Parkway to accommodate
electrical service to Lot 2.
(4) Extend the access easement from Ashford Square into this tract.
*Any changes to an approved plat must be cleared through the office of
the Director of Planning.
SUBMIT AN ORIGINAL AND 10 COPIES OF REVISED PLAT TO PLANNING DEPARTMENT BY
5:00 P.M, ON MARCH 30 TO BE INCLUDED ON P &Z AGENDA APRIL 5.
sjv
♦�� City of College Station
POST OFFICE BOX 9960 1101 TEXAS AVENUE
\ / COLLEGE STATION, TEXAS 77840 -2499
March 22, 1984
MEMORANDUM
TO: Bill Scarmardo, Bill Schutt
FROM: Project Review Committee:
Al Mayo, Director of Planning
David Pullen, City Engineer
David B. Hill, P &Z Representative
Other Staff:
Bob Epps, Asst. Director of Public Services
Joe Guidry, Electrical Superintendent
Bill Riley, Ass't. to Water & Sewer Superintendent
Jane Kee, Zoning Official
Kim Johnson, Ass't. Zoning Official
Rick Ploeger, City Forester
Shirley Volk, Planning Technician
Jim McCord, Elec. Power Engrs.
SUBJECT: Parking Lot Plan - Allen Honda (Auto Dealership) located on
Southwest Parkway & SH 6 Frontage Road - 84 - 408
The P.R.C. met on 3 -21-84 to review the above mentioned parking lot plan
and recommends approval of the plan as shown with the existing location
of Southwest Parkway with the following conditions:*
(1) Ass't. Director of Public Services Epps has indicated approval of
trash facilities as shown.
(2) Compliance with the P.R.C. drainage statement which has been provided
is required.
(3) If the interior double parking row contains more than ten spaces
per side, wheel stops are required.
(4) Show the dimension from the Frontage Road to the sign.
(5) A fire hydrant must be located within 300 feet of all parts of
all buildings.
(6) Buildings must be within 150 feet of a street or a fire lane. Fire
Marshal has indicated that all curb areas are to be marked as fire
lanes.
(7) Reduce the drive access to 36 feet in width.
(8) This plan will be placed on a Planning and Zoning Commission meeting
agenda for determination of the parking requirements for a car dealership.
It should be noted that this site plan has been approved with condition and
as shown with the existing location of Southwest Parkway. The configuration
of this particular tract of land may change with the future relocation of
Southwest Parkway and could change the site plan from the plan which has
been reviewed on 3- 21 -84.
SUBMIT 5 COPIES OF REVISED SITE PLAN TO PLANNING DEPARTMENT FOR APPROVAL
PRIOR TO ISSUANCE OF BUILDING PERMIT. PLAN IS SCHEDULED FOR P &Z MEETING ON
APRIL 5th.
♦ �� City of College Station
S k POST OFFICE BOX 9960 1 101 TEXAS AVENUE
/ COLLEGE STATION, TEXAS 77840 -2499
March 22, 1984
MEMORANDUM
TO: Wick McKean, Steve Hanse, Chris Galindo, Robin Bruno,
Jim Schutt
FROM: Project Review Committee:
Al Mayo, Director of Planning
David Pullen, City Engineer
David Hill, P &Z Representative
Other Staff:
Jane Kee, Zoning Official
Joe Guidry, Electrical Superintendent
Bill Riley, Ass't. to Water & Sewer Superintendent
Jim McCord, Elec. Power Engrs.
Bob Epps, Ass't. Director of Public Services
Rick Ploeger, City Forester
Kim Johnson, Asst. Zoning Official
Shirley Volk, Planning Technician
SUBJECT: Parking Lot Plan — Park Place (Shopping Center) located at
the corner of Southwest Parkway & Texas Avenue - 84 - 404
The P.R.C. met on 3 - 84 to review the above mentioned parking lot plan
and recommends approval with the following conditions:*
(1) Coordinate all utilities and easements (both existing and planned) with
the platting process and show on site plan so the location will be
exact.
(2) A 6 ft. continuous, solid screening fence is required between this
project and the existing mobile home park.
(3) The parallel parking spaces must be 22 feet in length.
(4) Maintain the required 8 foot setback from the R.O.W. to the parking
area.
(5) Dumpster numbers, sizes and locations must be changed to accommodate
individual stores and must comply with the directions given by the
Ass't. Dir. of Public Services, Bob Epps. Maintain a 50 ft. clearance
for maneuvering the garbage trucks.
(6) There is inadequate number of parking spaces available for employee
parking for this center. A variance must be granted by the Zoning
Board of Adjustments prior to issuance of a Building Permit.
(7) Relocate the signs so they will be more reasonably dispersed in this
center, or create a development agreement which limits the entire
center to one sign.
(8) Do not put large canopy trees under utility lines in the utility easements.
(9) Show the drainage pipes on the landscaping plans. The location of these
pipes may affect the size of the trees to be planted in islands over them.
Continued on page 2
P.R.C. Report 84 -404
3 -22 -84
page 2
(10) Compliance with the P.R.C. drainage statement which has been
provided is required.
(11) Clarify the location, type and application of sod and /or groundcover
in the landscaping notes.
`Any changes to an approved site plan must be cleared through the office
of the Director of Planning,
SUBMIT 5 COPIES OF THE REVISED SITE PLAN TO THE PLANNING DEPARTMENT FOR
APPROVAL PRIOR TO ISSUANCE OF BUILDING PERMIT.
sjv