HomeMy WebLinkAbout2022-4374 - Ordinance - 07/28/2022
ORDINANCE NO. 2022-4374
AN ORDINANCE AMENDING APPENDIX A, UNIFIED DEVELOPMENT
ORDINANCE, ARTICLE 5DISTRICT PURPOSE STATEMENTS AND
SUPPLEMENTAL STANDARDS SECTION 5.2 RESIDENTIAL DIMENSIONAL
STANDARDS AND ARTICLE
SECTION 8.3
DESIGN FOR SUBDIVISIONS WITHIN THE CITY LIMITS.4
, OF THE CODE OF ORDINANCES OF THE CITY OF
COLLEGE STATION, TEXAS, BY AMENDING CERTAIN SECTIONS RELATING TO
CLUSTER DEVELOPMENTS;PROVIDING A SEVERABILITY CLAUSE; DECLARING
A PENALTY; AND PROVIDING AN EFFECTIVE DATE.
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF COLLEGE STATION,
TEXAS:
PART 1: That Appendix AUnified Development Ordinance
Of Ordinances Of The City Of College Station, Texas, be amended as set out in
Exhibit A attached hereto and made a part of this Ordinance
for all purposes.
PART 2: If any provision of this Ordinance or its application to any person or circumstances
is held invalid or unconstitutional, the invalidity or unconstitutionality does not
affect other provisions or application of this Ordinance or the Code of Ordinances
of the City of College Station, Texas, that can be given effect without the invalid
or unconstitutional provision or application, and to this end the provisions of this
Ordinance are severable.
PART 3: That any person, corporation, organization, government, governmental subdivision
or agency, business trust, estate, trust, partnership, association and any other legal
entity violating any of the provisions of this Ordinance shall be deemed guilty of a
misdemeanor, and upon conviction thereof shall be punishable by a fine of not less
than twenty five dollars ($25.00) and not more than five hundred dollars ($500.00)
or more than two thousand dollars ($2,000) for a violation of fire safety, zoning, or
public health and sanitation ordinances, other than the dumping of refuse. Each day
such violation shall continue or be permitted to continue, shall be deemed a separate
offense.
PART 4: This Ordinance is a penal ordinance and becomes effective ten (10) days after its
date of passage by the City Council, as provided by City of College Station Charter
Section 35.
ORDINANCE NO. 2022-4374 Page 2 of 9
PASSED, ADOPTED and APPROVED this 28th day of July, 2022.
ATTEST: APPROVED:
_____________________________ _____________________________
City Secretary Mayor
APPROVED:
_______________________________
City Attorney
ORDINANCE NO. 2022-4374 Page 3 of 9
EXHIBIT A
of the Code of
Ordinances of the City of College Station, Texas, is hereby amended to read as follows:
Sec. 5.2. Residential Dimensional Standards.
The following table establishes dimensional standards that shall be applied within the Residential Zoning Districts,
unless otherwise identified in this UDO.
Residential Zoning Districts
R WE E(N)(P) WRS RS(J) GS(J)(P) T D MHP MF MU Accessory
Structures
Non-Clustered Residential Zoning Districts
Min. 3 Acres 2 1 Acre 20,000 10,000 5,000 SF 2,000 SF 3,500 SF >(L) None None Refer to
Average Lot Average Acres SF SF Section
Area per Average 6.5,
Dwelling Accessory
Unit (DU) Uses(L)
Absolute 2 Acres 2 1 Acre 20,000 6,500 SF 5,000 SF 2,000 SF 3,500 SF None None
Min. Lot Acres SF
Area per
Dwelling
Unit (DU)
Min. Lot None 100 100'(M) 70' 70' 50' None 35'/DU(E) None None
Width (M)
Min. Lot None None None None None 100' None 100' None None
Depth
Min. Front 50' 30' 30' 25' 25' 25'(D) 25'(D) 25'(D) 15' None
Setback (H)
Max. Front N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'(O)
Setback
Min. Side 20' 10' 10' 7.5' 7.5' (Q) 7.5' (Q) (A) 7.5'(C) (A) None
Setback (Q) (B)
Min. Side 15' 15' 15' 15' 15' 15' 15' 15' 15' None
Street
Setback
Max. Side N/A N/A N/A N/A N/A N/A N/A N/A N/A 15'(O)
Street
Setback
Min. Side N/A 15' 15' 15' 15' 15' 7.5' 15' 7.5' None
Setback
between
Structures(B)
Min. Rear 50' 20' 20' 20' 20' 20' 20' 20'(F) 20' 20'
Setback (L)
Max. 30% 30% 30% 40% 50% 55% 75% 65% (S) (S)
Impervious
Cover(R)
ORDINANCE NO. 2022-4374 Page 4 of 9
Max. Height 35' 35' 35' 35' 35' 2.5 35' 2.5 (G)(L) (G)(L)
(G)(K)(L) (G)(K) (G)(K)(L) (G)(K) (G)(K)(L) Stories/35' (G)(K)(L) Stories/35'
(G)(K)(L) (G)(K)(L)
Minimum N/A N/A N/A N/A N/A N/A N/A N/A N/A 2
Number of Stories
Stories
Max. 0.33 0.5 1.0 2.0 4.00 8.0 14.0 12.0 10.0 30.0 N/A N/A
Dwelling
Units/Acre
(Subdivision
Gross)
Min. N/A N/A N/A N/A N/A N/A N/A N/A N/A 12 N/A
Dwelling
Units/Acre
Clustered Residential Zoning Districts
Min. N/A 1 Acre 20,000 8,000 8,000 SF None N/A N/A N/A N/A N/A N/A
Average Lot SF SF Average
Area per Average
Dwelling
Unit (DU)
Absolute 1 Acre 10,000 8,000 6,500 SF None
Min. Lot SF SF
Area per
Dwelling
Unit (DU)
Min. Lot 100' 100'(M) None None None
Width (M)
Min. Lot None None None None None
Depth
Min. Front Refer to Section 8.3.H.4, Cluster Development, Specific
Setback (H) District Standards
Min. Side
Setback
Min. Street
Side Setback
Min. Side
Setback
between
Structures(B)
Min. Rear
Setback (L)
Max. 30% 30% 40% 50% 55%
Impervious
Cover(R)
Max. Height 35'(G) 35'(G) 35'(G) 35'(G) 2.5
(K) (K) (K) (K) Stories/
35'(G)
(K)(L)
Max. 0.5 1.0 2.0 4.00 8.0
Dwelling
Units/Acre
(Subdivision
Gross)
Notes:
(A) A minimum side setback of seven and one-half (7.5) feet is required for each building or group of
contiguous buildings.
ORDINANCE NO. 2022-4374 Page 5 of 9
(B) Lot line construction on interior lots with no side yard or setback is allowed only where the building is
covered by fire protection on the site or by dedicated right-of-way or easement.
(C) Zero lot line construction of a residence is allowed where property on both sides of a lot line is owned
and/or developed simultaneously by single party. Development under lot line construction requires prior
approval by the Zoning Official. In no case shall a single-family residence or duplex be built within
fifteen (15) feet of another primary structure. See Article 8, Subdivision Design and Improvements, for
more information.
(D) Minimum front setback may be reduced to fifteen (15) feet when approved rear access is provided, or
when side yard or rear yard parking is provided.
(E) The minimum lot width for a duplex dwelling may be reduced to thirty (30) feet per dwelling unit when
all required off-street parking is provided in the rear or side yard.
(F) Minimum rear setback may be reduced to fifteen (15) feet when parking is provided in the front yard or
side yard.
(G) Shall abide by Section 7.2 H., Height.
(H) Reference Section 7.2 D.1.e for lots created by plat prior to July 15, 1970 and designated as
Neighborhood Conservation in the Comprehensive Plan Future Land Use and Character Map.
(I) Reference Section 7.2 D.1.b for lots with approved rear access.
(J) For areas within a Single-Family Overlay District, reference the Neighborhood Prevailing Standards
Overlay Districts Section in Article 5 or the Ordinance authorizing the rezoning for Neighborhood
Conservation Overlay Districts.
(K) Public, civic, and institutional structures shall have a maximum building height of fifty (50) feet in these
districts.
(L) Reference Easterwood Field Airport Zoning Ordinance regarding height limitations.
(M) In subdivisions built to rural street standards, lots shall be a minimum of one hundred (100) feet in
width. There is no minimum lot width in cluster subdivisions built to urban street standards.
(N) Estate lots that are part of a subdivision existing on or before September 12, 2013 are not permitted to
use Cluster Development Standards without rezoning approval, which incorporates the entire
subdivision.
(O) For MU zoned properties, maximum side street and front setbacks may be measured from the edge of a
public easement when it is in excess of the maximum setback. Maximum setbacks may be increased to
up to eighty-five (85) feet to accommodate a parking lot between the structure and the street. Maximum
setback requirements may be fulfilled through the use of plazas, outdoor dining, and bicycle parking.
(P) Reference Section 8.3 H.4.e when using the cluster option in the Wellborn Community Plan area.
(Q) Minimum side setback may be reduced to five (5) feet where property on both sides of a lot line is
owned and/or developed simultaneously by a single party. Development under reduced side setbacks
requires prior approval by the Zoning Official, and must be established by plat. In no case shall a single-
family residence be built within fifteen (15) feet of another primary structure. When reduced side
setbacks are approved, sills, belt courses, cornices, buttresses, chimneys, flues, eaves, and other
architectural features are prohibited from extending into the required side yard setback
(R) Maximum impervious cover is to be defined by the applicable zoning district designation unless
otherwise mitigated by an on-site or regional drainage facility and associated drainage study as approved
by the City Engineer or his/her designee.
Work being performed by the homeowner and/or resident that does not require a building permit, that is
less than 120 square feet, and that does not cause the lot to exceed the applicable maximum impervious
cover, does not require an Impervious Coverage Permit.
ORDINANCE NO. 2022-4374 Page 6 of 9
(S) Maximum impervious cover for MF and MU zoning districts shall be determined by an engineered
drainage analysis performed in conjunction with the BCS Unified Stormwater Design Guidelines and as
approved by the City Engineer or his/her designee.
ORDINANCE NO. 2022-4374 Page 7 of 9
EXHIBIT B
That Appendix BArticle
of the Code of
Ordinances of the City of College Station, Texas, is hereby amended to read as follows:
4. Cluster Development.
a. General Purpose.
A cluster development is intended to provide open space, preserve unique environmental features,
or protect the character of rural areas. It is a residential subdivision in which the lots are allowed to
be smaller (in area and width) than otherwise required for the underlying, base zoning district, but
in which the overall density of all the lots collectively do not exceed the maximum density limit
for the underlying zoning district. Through the cluster development option, a subdivision can
contain no more lots than would otherwise be allowed for a conventional subdivision in the zoning
district, though the individual lots within the development can be smaller than required in a
conventional subdivision. The average lot size in a cluster development must be less than the
minimum lot size of the base zoning district. Smaller lot sizes within a cluster development are
required to be offset by the provision of open space as set forth below.
b. Conflict with Other Regulations.
If there is a conflict between the cluster development standards of this Section and any other
requirement of this UDO, the standards of this Section control. Where no conflict exists, a cluster
development is subject to all other applicable requirements of this UDO.
c. Where Allowed.
Cluster developments are allowed in residential WE Wellborn Estate, E Estate, RS Restricted
Suburban, WRS Wellborn Restricted Suburban, and GS General Suburban zoning districts.
d. Approval Procedure.
Cluster Developments are subject to the subdivision procedures set forth in this UDO. A note shall
be provided on the plat that states the subdivision is a cluster development with additional
descriptions as necessary.
e. Specific District Standards.
1. Wellborn Estate -
a. Lot Size. The minimum lot size is one (1) acre as long as individual lot sizes are adequate to
meet all other required density, district, and development standards. There is no set minimum
lot width or depth requirement within a cluster development, except as noted below.
Subdivisions with all lots over one acre and lot widths of one hundred (100) feet may use
rural character roads.
b. Setbacks and Building Separations. The minimum setback standards of the base zoning
district apply along the perimeter of a cluster development. All detached structures within a
cluster development must be separated by a minimum distance of ten (10) feet.
2. Estate -
a. Lot Size. The minimum average lot size is twenty thousand (20,000) square feet with an
absolute minimum lot size of ten thousand (10,000) square feet as long as individual lot sizes
are adequate to meet all other required density, district, and development standards. There is
no set minimum lot width or depth requirement within a cluster development, except as noted
below. Subdivisions with all lots over twenty thousand (20,000) square feet and lot widths of
one hundred (100) feet may use rural character roads. Subdivisions containing any lots below
twenty thousand (20,000) square feet must use urban street standards.
b. Setbacks and Building Separations. The minimum setback standards of the base zoning
district apply along the perimeter of a cluster development. All detached structures within a
cluster development must be separated by a minimum distance of ten (10) feet.
ORDINANCE NO. 2022-4374 Page 8 of 9
c. In the Wellborn Community Plan area, the cluster option may be used only in the area
designated Wellborn Preserve-Open on the Comprehensive Plan Land Use and Character
Map.
3. Wellborn Restricted Suburban
a. Lot Size. The minimum average lot size is eight thousand (8,000) square feet as long as
individual lot sizes are adequate to meet all other required density, district, and development
standards. There is no set minimum lot width or depth requirement within a cluster
development.
b. Setbacks and Building Separations. The minimum setback standards of the base zoning
district apply along the perimeter of a cluster development. All detached structures within a
cluster development must be separated by a minimum distance of ten (10) feet.
4. Restricted Suburban -
a. Lot Size. The minimum average lot size is eight thousand (8,000) square feet with an absolute
minimum lot size of six thousand five hundred (6,500) square feet as long as individual lot
sizes are adequate to meet all other required density, district, and development standards.
There is no set minimum lot width or depth requirement within a cluster development.
b. Setbacks and Building Separations. The minimum setback standards of the base zoning
district apply along the perimeter of a cluster development. All detached structures within a
cluster development must be separated by a minimum distance of ten (10) feet.
5. General Suburban -
a. Lot Size. There is no minimum lot size as long as individual lot sizes are adequate to meet all
other required density, district, and development standards. There is no set minimum lot width
or depth requirement within a cluster development.
b. Setbacks and Building Separations.
The minimum setback standards of the base zoning district apply along the
perimeter of a cluster development. All detached structures within a cluster
development must be separated by a minimum distance of ten (10) feet.
c. In the Wellborn Community Plan area as designated on the Comprehensive Plan Future Land
Use and Character Map, the cluster option is not permitted.
f. Open Space.
1. Description of Open Space.
Any parcel or parcels of land or an area of water, or a combination of land and water within
a development site provided and made legally available for the use and enjoyment of all
residents of a proposed project. Open space may include amenities such as private outdoor
recreation facilities, natural areas, trails, agricultural lands, or stormwater management
facilities designed as a neighborhood amenity. Areas encumbered by right-of-way,
easements, or utilized as parking may not be counted towards the Open space requirements.
Open spaces must be privately owned and maintained by a Home Owners Association
(HOA).
Common open space must be set aside and designated as an area where no development will
occur, other than project-related recreational amenities or passive open space areas. The
Commission may require that up to fifty (50) percent of required common open space be
useable recreational space, if deemed necessary by the Commission to ensure adequate
recreational amenities for residents of the development.
2. Common Open Space Required for Cluster Developments.
a. Minimum Requirement.
1. Common open space is required within a cluster development to ensure
that the overall density within the development does not exceed the
maximum density allowed by the underlying zoning district.
2. Common open space must be provided in an amount of at least twenty-
five (25) percent of the gross area of the development.
3. All proposed lots shall have direct access to the common open space, via
access easement, sidewalk, or street. Common open space may be located
ORDINANCE NO. 2022-4374 Page 9 of 9
at the rear of lots only when the space is designed for active recreation or a
design concept is submitted to staff for approval. Examples of active
recreation areas may include amenities such as sports fields, hike or bike
trails, parks, amenity centers, and golf courses.
4. All open space areas shall be part of a larger continuous and integrated
open space system within the parcel being developed. The required
common open space must be arranged to provide at least thirty (30)
percent of the space in at least one (1) contiguous area. The minimum
dimensions of such space must be at least twenty-five (25) feet in depth
and width. The remaining required common usable open space may be
distributed throughout the proposed subdivision, or subdivision phase if
applicable, and need not be in one (1) such area; provided, however, no
area containing less than five thousand (5,000) square feet will be
considered common usable open space. If the required open space totals
less than ten thousand (10,000) square feet all required open space shall be
in one (1) contiguous area.
5. The common open space requirement shall not be credited toward the
parkland dedication requirements specified in the City subdivision
ordinance.