Loading...
HomeMy WebLinkAbout07/20/2017 - Agenda Packet - Planning & Zoning CommissionPlanning and Zoning Commission Workshop College Station, TX Meeting Agenda - Final City Hall 1101 Texas Ave College Station, TX 77840 The City Council may or may not attend the Planning & Zoning Commission Workshop Meeting. City Hall Council Chambers6:00 PMThursday, July 20, 2017 1. Call the meeting to order. 2. Discussion of consent and regular agenda items. 3. Discussion of new development applications submitted to the City. New Development Link: www.cstx.gov/newdev Discussion of Minor and Amending Plats approved by Staff. *Final Plat ~ Amending Plat ~ The Science Park Subdivision Block 1, Lots 1A-3A ~ Case #FPCO2017-000007 (Paz) 17-03114. Sponsors:Paz Presentation, possible action, and discussion regarding the consideration of the 2017 P&Z Plan of Work (see attached) 17-03565. Sponsors:Bombek 2017 Plan of WorkAttachments: Presentation, possible action, and discussion regarding an update on the implementation of the organizational review report prepared by Alan Mueller, consultant. 17-03416. Sponsors:Simms P&Z MemoAttachments: Presentation, possible action, and discussion regarding the P&Z Calendar of Upcoming Meetings: *Thursday, July 27, 2017 ~ City Council Meeting ~ Council Chambers ~ Workshop 6:00 p.m. and Regular 7:00 p.m. (Liaison - Osborne) *Thursday, August 3, 2017 ~ P&Z Meeting ~ Council Chambers ~ Workshop 6:00 p.m. and Regular 7:00 p.m. 17-03757. Presentation, possible action, and discussion regarding an update on the following items: *A Rezoning for approximately three acres located at 5101 & 5102 Pebble Creek Parkway from Rural to General Suburban & Restricted Suburban. The Planning & Zoning Commission heard this item on June 15, 2017, a vote to recommend approval to 17-03768. Page 1 College Station, TX Printed on 7/14/2017 July 20, 2017Planning and Zoning Commission Workshop Meeting Agenda - Final Restricted Suburban passed (6-0), and a vote to recommend approval to General Suburban failed (3-3). The City Council heard this item on July 13, 2017, and a vote to approve Restricted Suburban zoning passed (6-1) with a condition of a 25-foot buffer against Champion's Boulevard, and a vote to approve General Suburban zoning passed (5-2) with the condition of 25-foot buffer against Champion's Boulevard. *A Rezoning for approximately two acres located at 2849 Barron Road from Planned Development District to Planned Development District. The Planning & Zoning Commission heard this item on June 15, 2017, and a vote to recommend approval failed (1-5). The City Council heard this item on July 13, 2017, and a vote to approve the request failed (0-7). *A Rezoning for approximately 18 acres located on Turkey Creek Road from General Commercial & Multi -Family to General Commercial and Multi-Family. The Planning & Zoning Commission heard this item on June 15, 2017, and voted (6-0) to recommend approval. The City Council heard this item on July 13, 2017, and voted (7-0) to approve the request. 9. Discussion, review and possible action regarding the following meetings: Design Review Board, BioCorridor Board. 10. Discussion and possible action on future agenda items - A Planning & Zoning Member may inquire about a subject for which notice has not been given. A statement of specific factual information or the recitation of existing policy may be given. Any deliberation shall be limited to a proposal to place the subject on an agenda for a subsequent meeting. 11. Adjourn. The Commission may adjourn into Executive Session to consider any item listed on this agenda if a matter is raised that is appropriate for Executive Session discussion . An announcement will be made of the basis for the Executive Session discussion. APPROVED _____________________ City Manager I certify that the above Notice of Meeting was posted at College Station City Hall, 1101 Texas Avenue, College Station, Texas, on July 14, 2017 at 5:00 p.m. _____________________ City Secretary Page 2 College Station, TX Printed on 7/14/2017 July 20, 2017Planning and Zoning Commission Workshop Meeting Agenda - Final This building is wheelchair accessible. Persons with disabilities who plan to attend this meeting and who may need accommodations, auxiliary aids, or services such as interpreters, readers, or large print are asked to contact the City Secretary ’s Office at (979) 764-3541, TDD at 1-800-735-2989 , or email adaassistance@cstx .gov at least two business days prior to the meeting so that appropriate arrangements can be made . If the City does not receive notification at least two business days prior to the meeting, the City will make a reasonable attempt to provide the necessary accommodations. Penal Code § 30.07. Trespass by License Holder with an Openly Carried Handgun. "Pursuant to Section 30.07, Penal Code (Trespass by License Holder with an Openly Carried Handgun) A Person Licensed under Subchapter H, Chapter 411, Government Code (Handgun Licensing Law), may not enter this Property with a Handgun that is Carried Openly." Codigo Penal § 30.07. Traspasar Portando Armas de Mano al Aire Libre con Licencia. “Conforme a la Seccion 30.07 del codigo penal (traspasar portando armas de mano al aire libre con licencia), personas con licencia bajo del Sub-Capitulo H, Capitulo 411, Codigo de Gobierno (Ley de licencias de arma de mano), no deben entrar a esta propiedad portando arma de mano al aire libre.” Page 3 College Station, TX Printed on 7/14/2017 Page 1 of 5 2017 Planning & Zoning Commission Plan of Work Comprehensive Plan Items Implementation of Adopted Plans Summary: Implementation of adopted master plans and neighborhood, district, and corridor plans, namely: Central College Station, Eastgate, Southside Area, Wellborn Community, and South Knoll Area neighborhood plans, and Bicycle, Pedestrian & Greenways, Parks and Recreation, Water, Waste Water, Medical District, and Economic Development master plans. Project Dates: Staff Assigned: P&DS Staff Anticipated Completion: Thoroughfare Plan Update Summary: Project Dates: The Metropolitan Planning Organization (MPO) is in the process of updating its Concept Map for the BCS region. Once adopted by the MPO, the city is anticipating taking action to amend the Thoroughfare Plan to align with the changes in the MPO’s regional Concept Map. 06/15/17: Provide an update on the BCS Thoroughfare Concept Map as adopted by the MPO and provide information on the City’s next steps to amend the current Thoroughfare Master Plan. Presentation at P&Z Workshop. (JS) Staff Assigned: Jason Schubert Initiated: June 15, 2017 Bicycle, Pedestrian and Greenways Master Plan Update Summary: Bring additional updates to the Planning and Zoning Commission as the Master Plan update moves forward. Project Dates: Staff Assigned: Venessa Garza, P&DS Staff Anticipated Completion: Page 2 of 5 Neighborhood Integrity Items *Traffic Calming Toolkit Summary: Receive information regarding the current traffic calming policy and devices (speed pillows, etc.), and including updates as recommended by the Council Transportation and Mobility Committee. Additionally receive update on the implementation of the neighborhood parking toolbox created by the Neighborhood Transportation Task Force. Project Dates: Staff Assigned: Troy Rother & Jason Schubert Anticipated Completion: January 2017 Student Housing in Established Single-Family Neighborhoods Summary: Research best practices from peer university communities regarding the management of student housing in single-family neighborhoods. Explore the possibility of expanding options for Neighborhood Conservation Overlay (NCO), mitigate the impacts to on-street parking and drainage and provide educational opportunities for Homeowner’s Associations and Neighborhood Associations Project Dates: 4/20/17: Follow up discussion regarding the presentation on student housing in established single-family neighborhoods. Staff Assigned: Mark Bombek, Rachel Lazo & Jade Broadnax Anticipated Completion: October 2017 Page 3 of 5 UDO Regulatory Items Evaluation of UDO Regulations Summary: Project Dates: Review UDO requirements that add minimal value as identified by staff and consider opportunities to reduce regulations and streamline processes. 06/01/17 Presentation of staff's initial list of identified opportunities to reduce regulations and streamline processes. 7/6/2017: Presentation of Draft UDO Amendments to eliminate certain screening requirements and eliminate the visual treatment for exposed concrete. Staff Assigned: Justin Golbabai Anticipated Initiation: June 1, 2017 Sign Ordinance Revisions Summary: Review and update the City’s sign ordinance in light of the recent Supreme Court decision regarding sign regulations based upon content. Project Dates: Staff Assigned: Molly Hitchcock, Rachel Lazo & Legal Anticipated Completion: December 2017 Update on Off-Street Parking Requirements Summary: Provide options to allow flexibility to off - street parking requirements. Receive direction on future UDO text amendments. Project Dates: 5/4/17: Additional presentation and discussion on potential amendments or additions to the City’s current off-street parking requirements. Staff Assigned: Justin Golbabai Anticipated Completion: Suburban Commercial Land Use and Zoning Summary: Under City Council direction, review current Comprehensive Plan land use description and zoning ordinance requirements of the Suburban Commercial zoning district and provide options for future text amendments. Project Dates: Staff Assigned: Madison Thomas, Jenifer Paz, Alaina Helton Anticipated Completion: September 2017 Bicycle Rack Standards Summary: Under City Council direction, review current non- residential parking requirements for providing on- site bicycle parking facilities. Project Dates: Staff Assigned: Alaina Helton & Madison Thomas Anticipated Completion: August 3, 2017 Page 4 of 5 Non-Residential Landscaping Requirements Summary: Review current city landscaping requirements (including streetscaping and buffer standards) and the water usage needed to maintain current landscaping requirements. Explore options for water-conserving landscaping. Project Dates: Staff Assigned: Rachel Lazo, Madison Thomas, Mark Bombek Anticipated Completion: December 2017 On-Going Items Economic Development Updates Summary: Receive regular updates from the Economic Development Department regarding the vision and implementation of the commercialization of TAMU research- related output, including examples of successful efforts elsewhere. Additionally, receive an update on the recent announcement regarding plans for the TAMU System Rellis Campus revitalization effort. Project Dates: 06/15/17: Provide a quarterly update on Economic Development efforts and land availability for commercial uses. Presentation at P&Z Workshop. (NR) Staff Assigned: Economic Development Anticipated Completion: On-Going Semi-Annual Review of Pre-Application Conference Surveys Summary: Provide an update on the survey results from the Pre-Application Conference process. Project Dates: 3/16/17: Provide an update on the status of the PAC meeting process and implementation of the PAC survey. Presentation at P&Z Workshop. (MB) Staff Assigned: Mark Bombek Anticipated Completion: On-Going Page 5 of 5 Educational/informational Items Parkland Dedication Summary: Review of parkland dedication requirements and available resources. Project Dates: 7/6/17: Staff presented information regarding parkland dedication requirements and summary or parks and greenways master plan. Staff Assigned: Jenifer Paz Completed: July 6, 2017 Sidewalk Fee-in-Lieu Summary: Review of sidewalk fund requirements and available resources. Project Dates: Staff Assigned: Lauren Hovde & Mark Bombek Anticipated Completion: September 2017 Block Length and Block Perimeter Summary: Review of current requirements regarding block length and block perimeter. Project Dates: Staff Assigned: Justin Golbabai & Jason Schubert Anticipated Completion: September 2017 Public Hearing Notifications Summary: Review current community notification requirements and practices for cases involving a public hearing. Project Dates: Staff Assigned: Lance Simms Anticipated Completion: October 2017 Mueller Report Update Summary: Update on the implementation of the 2013 Organizational Review of P&DS (AKA “Mueller Report”) Project Dates: 07/20/17: Provide an update on the implementation of the Mueller Report. Staff Assigned: Lance Simms Anticipated Completion: July 20, 2017 Review of Development Fees Summary: Evaluation of the effect of development fees on the price of single family housing to the homeowner and an overview of the financial context of development fees for the City. Project Dates: Staff Assigned: Justin Golbabai & Alaina Helton Anticipated Completion: November 2017 1101 Texas Avenue, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM TO: Planning & Zoning Commission FROM: Lance Simms, Director of Planning & Development Services DATE: 20 July 2017 SUBJECT: Update on Implementation of the Mueller Report Item Presentation, possible action, and discussion regarding an update on the implementation of the organizational review report prepared by Alan Mueller, consultant. Background This workshop presentation is in response to an item identified on the Commission’s 2017 Plan of Work. In 2013, the City Manager’s office retained Marsh Darcy Partners to perform an organizational review of the Planning and Development Services Department. The purpose of the review was to identify and assess the validity of internal and external perceptions related to the performance of the department. The review centered on three primary functions:  Evaluate departmental policies, procedures, and attitudes as they pertain to customer interactions and service delivery quality.  Evaluate the perceptions of the City Council, Planning Commission, and departmental customers (external stakeholders) regarding the performance of the department.  Identify opportunities for improvement based on aligning the performance of the department with the needs and perceptions of the external stakeholders. The report contained a number of recommendations intended to move the City’s development review process toward desired outcomes and rectify the mismatch in perceptions and attitudes identified in the report. At the P&Z Workshop meeting, Staff will provide an update on implementation efforts to date. Planning and Zoning Commission Regular College Station, TX Meeting Agenda - Final City Hall 1101 Texas Ave College Station, TX 77840 The City Council may or may not attend the Planning & Zoning Commission Regular Meeting. City Hall Council Chambers7:00 PMThursday, July 20, 2017 1. Call meeting to order. 2. Pledge of Allegiance. 3. Hear Citizens. At this time, the Chairman will open the floor to citizens wishing to address the Commission on issues not already scheduled on tonight's agenda. The citizen presentations will be limited to three minutes in order to accommodate everyone who wishes to address the Commission and to allow adequate time for completion of the agenda items. The Commission will receive the information, ask city staff to look into the matter, or will place the matter on a future agenda for discussion. (A recording is made of the meeting; please give your name and address for the record.) All matters listed under Item 4, Consent Agenda, are considered routine by the Commission and will be enacted by one motion. These items include preliminary plans and final plats, where staff has found compliance with all minimum subdivision regulations. All items approved by Consent are approved with any and all staff recommendations. There will not be separate discussion of these items. If any Commissioner desires to discuss an item on the Consent Agenda it will be moved to the Regular Agenda for further consideration. 4. Consent Agenda Consideration, possible action, and discussion on Absence Requests from meetings. *Casey Oldham ~ July 20, 2017 17-03474.1 Consideration, possible action, and discussion to approve meeting minutes. *July 6, 2017 ~ Workshop *July 6, 2017 ~ Regular 17-03484.2 July 6 2017 Workshop July 6 2017 Regular Attachments: Presentation, possible action, and discussion regarding a Final Plat for Castlegate II Subdivision Section 210 consisting of 71 single-family lots and four common areas on approximately 25 17-03434.3 Page 1 College Station, TX Printed on 7/13/2017 July 20, 2017Planning and Zoning Commission Regular Meeting Agenda - Final acres, generally located southwest of Castlegate II Subdivision Section 205. Case #FP2016-000029 Sponsors:Thomas Staff Report Application Final Plat Attachments: Presentation, possible action, and discussion regarding a Final Plat for The Crossing at Lick Creek Phase 2 consisting of 43 residential lots and 2 common area lots on approximately 22 acres located at 13500 Rock Prairie Road, generally located south of the William D Fitch Parkway and West of Williams Creek Subdivision. Case #FP2016-000018 17-03554.4 Sponsors:Bombek Staff Report Application Final Plat Attachments: Presentation, possible action, and discussion regarding a Final Plat for Rio Grande Subdivision consisting of 67 residential lots and 2 common area lots on approximately 7.24 acres located at 2021 Harvey Mitchell Parkway South, generally located northeast of the intersection of Harvey Mitchell Parkway South with Rio Grande Blvd, and west of Southwood Drive. Case # FP2015-000004 17-03584.5 Sponsors:Bombek Staff Report Applicaiton Final Plat Attachments: Presentation, possible action, and discussion regarding a Final Plat for Harvey Road Subdivision Phase 1 consisting of 1 lot and common area on approximately 17 acres located at 3210 Harvey Road generally located west of the intersection of State Highway 30 and Linda Lane. Case # FP2017-000009 17-03544.6 Sponsors:Bombek Staff Report Application Final Plat Attachments: Regular Agenda Page 2 College Station, TX Printed on 7/13/2017 July 20, 2017Planning and Zoning Commission Regular Meeting Agenda - Final 5. Consideration, possible action, and discussion on items removed from the Consent Agenda by Commission action. Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas, by changing the zoning district boundaries from PDD Planned Development District to PDD Planned Development District for approximately 8 acres in the Chimney Hill Retail Plaza Lots 1-4, Block 1, generally located at 701 & 715 University Drive East. Case #REZ2017-000013 (Note: Final action on this item is scheduled for the August 10, 2017 City Council meeting- subject to change) 17-03626. Sponsors:Bombek Staff Report Background Information Aerial and Small Area Map Application Concept Plan bulk variance list Attachments: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from R Rural to GC General Commercial on approximately 35.91 acres of land being situated in the J.W. Scott Survey, Abstract No. 49 in College Station, Brazos County, Texas, located at 4000 and 4002 University Drive East, and more generally located south of the intersection of University Drive East and FM158 at the College Station city limit line. Case #REZ2017-000016 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting - subject to change) 17-03607. Sponsors:Prochazka Staff Report Background Location Map, Aerial, Small Area Map Zoning Map Attachments: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified 17-03618. Page 3 College Station, TX Printed on 7/13/2017 July 20, 2017Planning and Zoning Commission Regular Meeting Agenda - Final Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from GS General Suburban to GC General Commercial for approximately one acre of land being College Hills Estates Block 18, Lots 6, 7, 8, 9 and 11, more generally located at 108, 110, 200 & 206 George Bush Drive East. Case #REZ2017-000017 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting - subject to change) Sponsors:Prochazka Staff Report Background Aerial and Small Area Map Zoning Map Attachments: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from CI Commercial Industrial to GC General Commercial on approximately 8.158 acres of land located at 1501 Earl Rudder Freeway South, and more generally located on the east side of Earl Rudder Freeway, north of Harvey Road. Case #REZ2017-000018 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting - subject to change) 17-03689. Sponsors:Prochazka Staff Report Background Aerial and Small Area Map Zoning Map Attachments: Public hearing, presentation, possible action, and discussion regarding an ordinance amending the Comprehensive Plan - Future Land Use & Character Map from General Suburban and Business Park to General Commercial for approximately 100 acres located along the east side of State Highway 6, south of The Business Park at College Station and north of the Texas World Speedway property. Case #CPA2017-000008 and Case #CPA2017-000009 (Note: Final action of this item will be considered at the July 27, 2017 City Council Meeting- subject to change.) 17-037010. Page 4 College Station, TX Printed on 7/13/2017 July 20, 2017Planning and Zoning Commission Regular Meeting Agenda - Final Sponsors:Prochazka Staff Report Background Aerial Land Use Comparison Attachments: 11. Discussion and possible action on future agenda items – A Planning & Zoning Member may inquire about a subject for which notice has not been given. A statement of specific factual information or the recitation of existing policy may be given. Any deliberation shall be limited to a proposal to place the subject on an agenda for a subsequent meeting. 12. Adjourn The Commission may adjourn into Executive Session to consider any item listed on this agenda if a matter is raised that is appropriate for Executive Session discussion. An announcement will be made of the basis for the Executive Session discussion. APPROVED _____________________ City Manager I certify that the above Notice of Meeting was posted at College Station City Hall, 1101 Texas Avenue, College Station, Texas, on July 14, 2017 at 5:00 p.m. _____________________ City Secretary This building is wheelchair accessible. Persons with disabilities who plan to attend this meeting and who may need accommodations, auxiliary aids, or services such as interpreters, readers, or large print are asked to contact the City Secretary’s Office at (979) 764-3541, TDD at 1-800-735-2989, or email adaassistance@cstx.gov at least two business days prior to the meeting so that appropriate arrangements can be made. If the City does not receive notification at least two business days prior to the meeting, the City will make a reasonable attempt to provide the necessary accommodations. Penal Code § 30.07. Trespass by License Holder with an Openly Carried Handgun. "Pursuant to Section 30.07, Penal Code (Trespass by License Holder with an Openly Carried Handgun) A Person Licensed under Subchapter H, Chapter 411, Government Code (Handgun Licensing Law), may not enter this Property with a Handgun that is Carried Openly." Page 5 College Station, TX Printed on 7/13/2017 July 20, 2017Planning and Zoning Commission Regular Meeting Agenda - Final Codigo Penal § 30.07. Traspasar Portando Armas de Mano al Aire Libre con Licencia. “Conforme a la Seccion 30.07 del codigo penal (traspasar portando armas de mano al aire libre con licencia), personas con licencia bajo del Sub-Capitulo H, Capitulo 411, Codigo de Gobierno (Ley de licencias de arma de mano), no deben entrar a esta propiedad portando arma de mano al aire libre.” Page 6 College Station, TX Printed on 7/13/2017 July 6, 2017 P&Z Workshop Meeting Minutes Page 1 of 3 MINUTES PLANNING & ZONING COMMISSION Workshop Meeting July 6, 2017 6:00 p.m. CITY HALL COUNCIL CHAMBERS College Station, Texas COMMISSIONERS PRESENT: Jane Kee, Casey Oldham, Johnny Burns, Elianor Vessali, Bill Mather, and Jeremy Osborne COMMISSIONERS ABSENT: Keith Williamson CITY COUNCIL MEMBERS PRESENT: Jerome Rektorik CITY STAFF PRESENT: Lance Simms, Molly Hitchcock, Alan Gibbs, Carol Cotter, Mark Bombek, Jenifer Paz, Alaina Helton, Rachel Lazo, Kevin Ferrer, Erika Bridges, Anthony Armstrong, Kelly Kelbly, Mary Ann Powell, Chandler Az and Kristen Hejny 1. Call the meeting to order. Chairperson Kee Called the meeting to order at 6:03 p.m. 2. Discussion of consent and regular agenda items. There was general discussion regarding Regular Agenda Item #6. 3. Discussion of new development applications submitted to the City. New Development Link: www.cstx.gov/newdev There was no discussion. 4. Presentation, possible action, and discussion regarding the consideration of the 2017 P&Z Plan of work. Senior Planner Bombek presented updates on the 2017 P&Z Plan of Work to the Commission. There was general discussion. 5. Presentation, possible action, and discussion regarding a review of parkland dedication requirements and available resources. Senior Planner Paz presented this item to the Commission. There was general discussion. Commissioner Mather asked if the City utilizes any financial model outside intrinsic value on an economic basis and if parks pay for themselves. Assistant Director of Parks & Recreation Kelbly stated that currently, maintenance comes from the general fund. July 6, 2017 P&Z Workshop Meeting Minutes Page 2 of 3 Commissioner Mather asked if the Parks & Recreation Department measures the parkland benefits to the community. Assistant Director of Parks & Recreation Kelbly stated that they are currently working on a way to measure benefits. Commissioner Kee asked if the Parks & Recreation Department separates land dedication from development fees, so that it is spent correctly. Assistant Director of Parks & Recreation Kelbly stated that the funds are kept separate. Commissioner Kee asked if the Parks & Recreation Department is working with the City’s Legal Department to revamp the ability for developers to request parkland dedication fees back after a certain amount of time. Assistant Director of Parks & Recreation Kelbly stated that they are currently working on new language for the process. Commissioner Mather asked if parkland dedication funds are accounted for separately. Assistant Director of Parks & Recreation Kelbly stated that the funds are accounted for separately, within the general fund. Commissioner Oldham asked if the developer dedicates, are they required to also develop a park. Senior Planner stated Paz in some cases where land is dedicated, they are also requesting to develop a park. 6. Presentation, possible action, and discussion regarding the P&Z Calendar of Upcoming Meetings: *Thursday, July 13, 2017 ~ City Council Meeting ~ Council Chambers ~ Workshop 6:00 p.m. and Regular 7:00 p.m. (Liaison – Mather) *Thursday, July 20, 2017 ~ P&Z Meeting ~ Council Chambers ~ Workshop 6:00 p.m. and Regular 7:00 p.m. There was no discussion. 7. Discussion, review and possible action regarding the following meetings: Design Review Board, Bio Corridor Board. There was no discussion. 8. Discussion and possible action on future agenda items - A Planning & Zoning Member may inquire about a subject for which notice has not been given. A statement of specific factual information or the recitation of existing policy may be given. Any deliberation shall be limited to a proposal to place the subject on an agenda for a subsequent meeting. There were no items. 9. Adjourn. July 6, 2017 P&Z Workshop Meeting Minutes Page 3 of 3 The meeting was adjourned at 7:20 p.m. Approved: Attest: ______________________________ ________________________________ Jane Kee, Chairman Kristen Hejny, Admin. Support Specialist Planning & Zoning Commission Planning & Development Services July 6, 2017 P&Z Regular Meeting Minutes Page 1 of 4 MINUTES PLANNING & ZONING COMMISSION Regular Meeting July 6, 2017, 7:00 p.m. CITY HALL COUNCIL CHAMBERS College Station, Texas COMMISSIONERS PRESENT: Jane Kee, Casey Oldham, Johnny Burns, Elianor Vessali, Bill Mather, and Jeremy Osborne COMMISSIONERS ABSENT: Keith Williamson CITY COUNCIL MEMBERS PRESENT: Jerome Rektorik CITY STAFF PRESENT: Lance Simms, Molly Hitchcock, Alan Gibbs, Carol Cotter, Mark Bombek, Jenifer Paz, Alaina Helton, Rachel Lazo, Kevin Ferrer, Erika Bridges, Anthony Armstrong, Mary Ann Powell, Chandler Az and Kristen Hejny 1. Call Meeting to Order Chairperson Kee called the meeting to order at 7:29 p.m. 2. Pledge of Allegiance 3. Hear Citizens Fred Dupriest, 400 Fairview Avenue, College Station, spoke with concerns regarding the rule of decision for the rezoning of a property on Gilchrist. Mr. Dupriest suggested that Staff use a “Rule of Decision” that existing zoning has a superior claim in the established neighborhood and the rezoning must benefit the neighborhood. 4. Consent Agenda Commissioner Mather abstained from voting on Consent Agenda Item #4.1. 4.1 Consideration, possible action, and discussion to approve meeting minutes. *June 15, 2017 Workshop *June 15, 2017 Regular 4.2 Presentation, possible action, and discussion regarding a Preliminary Plan for Gandy Subdivision consisting of 2 lots on approximately 16.22 acres located at 1700 Graham Road, generally located at the southwest corner of Longmire Drive and Graham Road. Case #PP2017-000007 4.3 Presentation, possible action, and discussion regarding a Final Plat for the Jones Crossing Development Phase A consisting of three commercial lots, one residential lot, and one common area on approximately 62.9 acres located at 1720 Harvey Mitchell Parkway South, generally located at the hard southeast corner of Wellborn Road and Harvey Mitchell Parkway South. Case #FPMU2017-000001 July 6, 2017 P&Z Regular Meeting Minutes Page 2 of 4 Commissioner Osborne motioned to approve Consent Agenda Items 4.1 - 4.3. Commissioner Oldham seconded the motion, motion to approve items 4.2 – 4.3 passed (6-0), and the motion to approve item 4.1 passed (5-1) with Commissioner Mather abstaining. Regular Agenda 5. Consideration, possible action, and discussion on items removed from the Consent Agenda by Commission Action. No items were removed. 6. Public hearing, presentation, possible action, and discussion regarding an ordinance amending the Comprehensive Plan – Future Land Use & Character Map from Urban and Natural Areas Reserved to General Commercial and Natural Areas Reserved for approximately 12.5 acres located at 2338 Harvey Mitchell Parkway South. Case #CPA2017-000006 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting – subject to change) Senior Planner Bombek presented the Comprehensive Plan Amendment to the Commission and recommended approval. Chairperson Kee opened the public hearing. No one spoke. Chairperson Kee closed the public hearing. Commissioner Burns motioned to recommend approval of the Comprehensive Plan Amendment as presented. Commissioner Mather seconded the motion, motion passed (6-0). 7. Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from GS General Suburban, P-MUD Planned Mix-Use District with OV Corridor Suburban and O Office to GC General Commercial with OV Corridor Overlay, MF Multi-Family and NAP Natural Areas Protected on approximately 27.868 acres of land, generally located at 2338 Harvey Mitchell Parkway South. Case #REZ2017-000009 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting – subject to change) Senior Planner Bombek presented the Rezoning to the Commission and recommended approval. There was general discussion. Chairperson Kee opened the public hearing. John Jordan, 2339 Harvey Mitchell Parkway, College Station, requested clarification on the rezoning for the property. Chairperson Kee closed the public hearing. July 6, 2017 P&Z Regular Meeting Minutes Page 3 of 4 Commissioner Osborne motioned to recommend approval the Rezoning. Commissioner Burns seconded the motion, motion passed (6-0). 8. Public hearing, presentation, possible action, and discussion regarding an ordinance amending the Comprehensive Plan – Future Land Use & Character Map from Suburban Commercial to General Commercial approximately 3.34 acres located at 2381 Earl Rudder Freeway South, generally located north of Raintree Drive along Earl Rudder Freeway South. Case #CPA2017-000005 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting – subject to change) Senior Planner Bombek presented the Comprehensive Plan Amendment to the Commission and recommended approval. Applicant, Crissy Hartl, 3204 Earl Rudder Freeway South, College Station was available to present to the Commission. Chairperson Kee opened the public hearing. Charles Hamilton, 7714 Appomattox Drive, College Station, Texas, spoke with concerns of surrounding development, and access to adjacent properties and future developments. Ron Ross, 7717 Appomattox Drive, College Station, Texas, spoke with concerns for the use of the property, and neighborhood integrity. Bill Lero, 4421 Nottingham, Bryan, Texas, spoke on citizen concerns for the rezoning, including flooding, drainage, and neighborhood integrity. Chairperson Kee closed the public hearing. There was general discussion. Commissioner Oldham motioned to recommend approval of the Comprehensive Plan Amendment as presented. Commissioner Osborne seconded the motion, motion passed (6-0). 9. Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from SC Suburban Commercial to GC General Commercial on approximately 3.34 acres of land being situated in the McGill Subdivision, Lot 1, Block 1, generally located north of Raintree Drive along Earl Rudder Freeway South. Case #REZ2017-000007 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting – subject to change) Senior Planner Bombek presented the Rezoning to the Commission and recommended approval. Bill Lero, 4421 Nottingham, Bryan, Texas, was available to speak on the rezoning. Chairperson Kee opened the public hearing. No one spoke. July 6, 2017 P&Z Regular Meeting Minutes Page 4 of 4 Chairperson Kee closed the public hearing. Commissioner Oldham motioned to recommend approval the Rezoning. Commissioner Burns seconded the motion, motion passed (6-0). 10. Public hearing, presentation, possible action, and discussion regarding an amendment to Chapter 12, Unified Development Ordinance, Section 7.6.B, Section 7.6.D.4, Section 7.9.B of the Code of Ordinances of the City of College Station, Texas regarding landscaping for single-family developments, screening of retaining walls, and visual treatment of drainage features such as concrete weirs, outlets, and spillways. Case #ORDA2017-000003 (Note: Final action on this item is scheduled for the July 27, 2017 City Council meeting – subject to change) Director of Planning & Development Services Simms presented the Ordinance Amendment to the Commission, and recommended approval. Commissioner Vessali asked if in the proposed changes in the Unified Development Ordinance (UDO), is this the only place where dumpsters are mentioned. Director Simms stated that screening of dumpster areas are covered elsewhere in UDO, and the amendment does not keep those from being screened. Chairperson Kee opened the public hearing. No one spoke. Chairperson Kee closed the public hearing. Commissioner Mather motioned to recommend approval the Ordinance Amendment. Commissioner Burns seconded the motion, motion passed (6-0). 11. Discussion and possible action on future agenda items – A Planning & Zoning Member may inquire about a subject for which notice has not been given. A statement of specific factual information or the recitation of existing policy may be given. Any deliberation shall be limited to a proposal to place the subject on an agenda for a subsequent meeting. Commissioner Mather requested an update on Southside Neighborhood unique issues. 12. Adjourn The meeting adjourned at 8:22 p.m. Approved: Attest: ______________________________ ________________________________ Jane Kee, Chairman Kristen Hejny, Admin Support Specialist Planning & Zoning Commission Planning & Development Services Planning & Zoning Commission Page 1 of 3 July 20, 2017 FINAL PLAT for Castlegate II Subdivision Section 210 FP2016-000029 SCALE: 71 single-family lots and four common areas on approximately 25.489 acres LOCATION: Generally located southwest of Castlegate II Subdivision Section 205 and northwest of Sweetwater Forest Subdivision ZONING: RS Restricted Suburban APPLICANT: Wallace Phillips IV PROJECT MANAGER: Madison Thomas, AICP Staff Planner mthomas@cstx.gov PROJECT OVERVIEW: The last of the three phases in Castlegate II Subdivision. RECOMMENDATION: Staff recommends approval of the Final Plat. Planning & Zoning Commission Page 2 of 3 July 20, 2017 Planning & Zoning Commission Page 3 of 3 July 20, 2017 DEVELOPMENT HISTORY Annexation: 1995 Zoning: A-O Agricultural Open upon annexation A-O Agricultural Open to A-OR Rural Residential (2000); A-OR Rural Residential renamed E Estate (2013); E Estate rezoned RS Restricted Suburban (2015) Preliminary Plan: Initially approved in 2010 with revised versions approved by the Planning Commission in 2012, 2015 and most recently on April 21, 2016. Site Development: The site area is undeveloped. COMMENTS Parkland Dedication: Previous parkland for neighborhood parks has been dedicated, and has covered all lots in Castlegate II Section 210. Past park improvements have covered all Neighborhood Park Development fees. A fee in lieu of Community Parkland dedication and development of $625 per lot for 71 lots will be required, totaling $44,375. Greenways: N/A Pedestrian Connectivity: Sidewalks will be installed along Victoria Avenue and along both sides of all internal residential streets. Bicycle Connectivity: Bike lanes will be provided along Victoria Avenue. Impact Fees: The tract is subject to the city wide impact fees: Water, Sanitary Sewer, and Street. Impact Fees will be dependent upon timing of building permit’s application date. REVIEW CRITERIA Compliance with Subdivision Regulations: The proposed Final Plat is in compliance with the approved Preliminary Plan and the Subdivision Requirements contained in the Unified Development Ordinance. STAFF RECOMMENDATION Staff recommends approval of the Final Plat. SUPPORTING MATERIALS 1. Application 2. Copy of Final Plat FOR OFFICE USE ONLY FINAL PLAT APPLICATION Date of Optional Preapplication or Stormwater Management Conference N.44 NAME OF PROJECT Castlegate II Subdivision -Section 210 ADDRESS Wctoria Avenue SPECIFIED LOCATION OF PROPOSED PLAT: Southwest of Castlegate II Subdivision,Section 208 APPLICANT/PROJECT MANAGER’S INFORMATION (Primary contact for the project): CASE NO.: Name Wallace Phillips Street Address 4490 Castlegate Drive City College Station Phone Number 979.690.7250 E-mail wsphiiips3~gmaiI.corn State T)(Zip Code 77845 Fax Number 979.690.1041 CITY OF COLLEGE STATION Home of TexizsAd’M Universiiy DATE SUBMITTED:_______________ TIME: STAFF: MiNIMUM SUBMITTAL REQUIREMENTS: Is this plat Commercial ~or Residential ~ (Check one)~Minor E Amending ~Final E Vacating E Replat ($700)($700)($932)($932)($932) Is this plat in the ETJ?~Yes ~No ~$700-$932 Final Plat Application Fee (see above). ~$233 Waiver Request to Subdivision Regulations Fee (if applicable). ~j $600 (minimum)Development Permit Application /Public Infrastructure Review and Inspection Fee.Fee is 1%of acceptable Engineer’s Estimate for public infrastructure,$600 minimum (if fee is>$600,the balance is due prior to the issuance of any plans or development permit). ~Application completed in full.This application form provided by the City of College Station must be used and may not be adjusted or altered.Please attach pages if additional information is provided. ~Copy of plat.(A signed mylar original must be submitted after approval.) ~Grading,drainage,and erosion control plan with supporting drainage report. ~Public infrastructure plan and supporting documents (if applicable). ~Copy of original deed restrictions/covenants for replats (if applicable). ~Title report for property current within ninety (90)days or accompanied by a Nothing Further Certificate current within ninety (90)days.The report must include applicable information such as ownership,liens, encumbrances,etc. ~The attached Final Plat checklist with all items checked off or a brief explanation as to why they are not. NOTE:A paid tax certificates from City of College Station,Brazos County and College Station I.S.D.will be due at the time of the mylar submittal prior to filing the plat. Revised 5/15 Page 1 of 9 PROPERTY OWNERS INFORMATION (All owners must be identified.Please attach an additional sheet for multiple owners): Name Greens Prairie Investors, LTD E-mail wsphillips3@gmail.com Street Address 4490 Castlegate Drive City College Station State ~‘Zip Code 77845 Phone Number 979.690.7250 Fax Number 979.690.1041 ARCHITECT OR ENGINEER’S INFORMATION: Name Schultz Engineering,LLC -Joe Schultz E-mail i0e@schultzengineeringllc.corn Street Address 911 Southwest Pkwy E. City College Station State ~Zip Code 77845 Phone Number 979.764.3900 Fax Number 979.764.3910 Do any deed restrictions or covenants exist for this property?~J Yes ~No Is there a temporary blanket easement on this property?If so,please provide the Volume 10392 and Page No.276 Total Acreage 25.489 Total No.of Lots 71 R-O-W Acreage 3.893 Existing Use Agricultural -Vacant Proposed Use Single Family Residential Number of Lots By Zoning District 71 I RS I I Average Acreage Of Each Residential Lot By Zoning District: 19.809~RS ____/________ ____ Floodplain Acreage N/A Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels)on the property?fl Yes ~No This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance.Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s)and you are requesting the application be reviewed under previous ordinance as applicable? ~Yes flNo If yes,provide information regarding the first approved application and any related subsequent applications (provide additional sheets if necessary): Project Name:Castlegate II Preliminary Plat City Project Number (if known):PP2016-000003 Date I Timeframe when submitted:2015 Revised 5/15 Page 2 of 9 A statement addressing any differences between the Final Plat and Preliminary Plan (if applicable): one Requested waiver to subdivision regulations and reason for same (if applicable): None Regarding the waiver request,explain how: 1.There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land. 2.The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant. 3.The granting of the waiver will not be detrimental to the public health, safety,or welfare, or injurious to other property in the area,or to the City in administering subdivision regulations. Fee in lieu of sidewalk construction is being requested because of the following condition (if applicable): 1.fl An alternative pedestrian way or multi-use path has been or will be provided outside the right-of-way; 2.fl The presence of unique or unusual topographic,vegetative,or other natural conditions exist so that strict adherence to the sidewalk requirements of the UDO is not physically feasible or is not in keeping with the purposes and goals of the UDO or the City’s comprehensive Plan; 3.jEI A capital improvement project is imminent that will include construction of the required sidewalk.Imminent shall mean the project is funded or projected to commence within twelve (12)months; 4.~Existing streets constructed to rural section that are not identified on the Thoroughfare Plan with an estate I rural context; 5.~When a sidewalk is required along a street where a multi-use path is shown on the Bicycle,Pedestrian,and Greenways Master Plan; 4.The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of the Unified Development Ordinance. Revised 5115 Page 3 of 9 6.E~The proposed development is within an older residential subdivision meeting the criteria in Platting and Replatting within Older Residential Subdivisions Section of the UDO;or 7.~j The proposed development contains frontage on a Freeway /Expressway as designated by Map 6.6, Thoroughfare Plan -Functional Classification,in the City’s Comprehensive Plan. Detailed explanation of condition identified above: NOTE:A waiver to the sidewalk requirements and fee in lieu of sidewalk construction shall not be considered at the same time by the Planning &Zoning Commission. Requested Oversize Participation___________________________________________________________________________ Total Linear Footage of Parkiand Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE:3027_Streets _______No.of acres to be dedicated +$__________development fee ‘-‘~“Sidewalks No.of acres in floodplain871__Sanitary Sewer Lines No.of acres in detention3293_Water Lines No.of acres in greenways -Channels OR2173_Storm Sewers FEE IN LIEU OF LAND: -Bike Lanes I Paths No.of SF Dwelling Units X $______=$__________________ (date)Approved by Parks &Recreation Advisory Board NOTE:DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true,correct,and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY, this application must be accompanied by a power of attorney statement from the owner.If there is more than one owner,all owners must sign the application or the power of attorney.If the owner is a company,the application must be accompanied by proof of authority for the company’s representative to sign the application on its behalf LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above. 7/21/2016 Signature and title Date Revised 5/15 Page 4 of 9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1.No work of any kind may start until a permit is issued. 2.The permit may be revoked if any false statements are made herein. 3.If revoked,all work must cease until permit is re-issued. 4.Development shall not be used or occupied until a Certificate of Occupancy is issued. 5.The permit will expire if no significant work is progressing within 24 months of issuance. 6.Other permits may be required to fulfill local,state, and federal requirements. Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOl and SWPPP. 7.If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre pour)and post construction. 8.Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9.If,stormwater mitigation is required,including detention ponds proposed as part of this project,it shall be designed and constructed first in the construction sequence of the project. 10.In accordance with Chapter 13 of the Code of Ordinances of the City of College Station,measures shall be taken to insure that all debris from construction,erosion,and sedimentation shall not be deposited in city streets, or existing drainage facilities.All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project.All of the applicable codes and ordinances of the City of College Station shall apply. 11.The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station,Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications,and Standard Details.All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12.Release of plans to __________________________________(name or firm)is authorized for bidding purposes only.I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13.I,THE OWNER,AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION,ARE, TO THE BEST OF MY KNOWLEDGE,TRUE, AND ACCURATE. 7/21/2016 Property Owner(s)Date Engineer Certification: 1.The project has been designed to ensure that stormwater mitigation,including detention ponds,proposed as part of the project will be constructed first in the construction sequence. 2.I will obtain or can show compliance with all necessary Local,State and Federal Permits prior to construction including NOl and SWPPP. Design will not preclude compliance with TPDES:i.e.,projects over 10 acres may require a sedimentation basin. 3.The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of College Station,Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines.All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. I,THE ENGINEER,AGREE TO ~T ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT ARE,TO THE BEST OF MY KNOWLEDGE,TRUE,AND TE. Date Revised 5/15 Page 5 of 9 The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans, Final Plats,Construction Plans,Fill I Grading Permits,and Clearing Only Permits:* A.I,______________________________________certify,as demonstrated in the attached drainage study,that the alterations or development covered by this permit,shall not: (I)increase the Base Flood elevation; (ii)create additional areas of Special Flood Hazard Area; (iii)decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the velocity of flow in the Base Flood event is greater than one foot per second.This area can also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the depth of from the BFE to natural ground is 18 inches or greater; (iv)reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than one foot per second without acceptable compensation as set forth in the City of College Station Code of Ordinances,Chapter 13 concerning encroachment into the Special Flood Hazard Area;nor (v)increase Base Flood velocities. beyond those areas exempted by ordinance in Section 5.11.3a of Chapter 13 Code of Ordinances. Engineer Date Initial *If a platting-status exemption to this requirement is asserted,provide written justification under separate ______letter in lieu of certification. Required for Site Plans, Final Plats,Construction Plans, and Fill I Grading Permits: B.I,______________________________________,certify to the following: (i)that any nonresidential or multi-family structure on or proposed to be on this site as part of this application is designed to prevent damage to the structure or its contents as a result of flooding from the 100-year storm. Engineer Date Additional certification for Floodway Encroachments: C.I,__________________________________,certify that the construction,improvement,or fill covered by this permit shall not increase the base flood elevation.I will apply for a variance to the Zoning Board of Adjustments. Engineer Date Revised 5115 Page 6 of 9 Required for all projects proposing structures in Special Flood Hazard Area (Elevation Certificate required). Residential Structures: D.I,_______________________________________,certify that all new construction or any substantial improvement of any residential structure shall have the lowest floor including all utilities,ductwork and any basement,at an elevation at least one foot above the Base Flood Elevation. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre-pour)and post construction. Engineer!Surveyor Date Commercial Structures: E.I,_______________________________________,certify that all new construction or any substantial improvement of any commercial, industrial, or other non-residential structure are designed to have the lowest floor,including all utilities,ductwork and basements, elevated at least one foot above the Base Flood Elevation Engineer /Surveyor Date OR certify that the structure with its attendant utility,ductwork, basement and sanitary facilities is designed to be flood-proofed so that the structure and utilities,ductwork, basement and sanitary facilities are designed to be watertight and impermeable to the intrusion of water in all areas below the Base Flood Elevation,and shall resist the structural loads and buoyancy effects from the hydrostatic and hydrodynamic conditions. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre pour)and post construction. Engineer!Surveyor Date Conditions or comments as part of approval:________________________________________________________________ Revised 5/15 Page 7 of 9 FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) ~Drawn on 24”x 36”sheet to scale of 100’per inch. ~Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits.No scale required but include north arrow. ~Title Block with the following information: ~Name and address of subdivider,recorded owner,planner,engineer and surveyor. ~Proposed name of subdivision.(Subdivision name &street names will be approved through Brazos County 911.) ~Date of preparation. ~Engineer’s scale in feet. ~Total area intended to be developed. ~j North Arrow. ~Subdivision boundary indicated by heavy lines. El If more than I sheet,an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. ~All applicable certifications based on the type of final plat. ~Ownership and Dedication ~Surveyor and/or Engineer ~City Engineer (and City Planner,if a minor plat) ~Planning and Zoning Commission (delete if minor plat) ~Brazos County Clerk El Brazos County Commissioners Court Approval (ETJ Plats only) El If submitting a replat where there are existing improvements,submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. El If using private septic systems,add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner’s Court of Brazos County,pursuant to the provisions of Section 21.084 of the Texas Water Code. El Location of the 100-Year Floodplain and floodway,if applicable,according to the most recent available data. Lot corner markers and survey monuments (by symbol)and clearly tied to basic survey data. Matches the approved preliminary plan or qualifies as minor amendments (UDO Section 3.3.E.2). The location and description with accurate dimensions, bearings or deflection angles and radii,area,center angle,degree of curvature,tangent distance and length of all curves for all of the following:(Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision,as well as,those within the subdivision). Existing Proposed 1~1 Streets.Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. ~1 Public and private R.O.W.locations and widths.(All existing and proposed R.O.W.’s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Revised 5/15 Page 8 of 9 Existing Proposed D Alleys. 1~1 Easements. ~A number or letter to identify each lot or site and each block (numbered sequentially). D Parkland dedication/greenbelt area/park linkages.All proposed dedications must be reviewed by the Parks and Recreation Advisory Board and documentation of their recommendation provided prior to being scheduled for P&Z Commission consideration. ~Construction documents for all public infrastructure drawn on 24”x 36”sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: ~Street,alley and sidewalk plans,profiles and sections.One sheet must show the overall street,alley and/or sidewalk layout of the subdivision.(may be combined with other utilities). Sewer Design Report. Sanitary sewer plan and profile showing depth and grades.One sheet must show the overall sewer layout of the subdivision.(Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water Design Report and/or Fire Flow Report. Water line plan showing fire hydrants, valves,etc.with plan and profile lines showing depth and.grades.One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours,street profile, inlets,storm sewer and drainage channels,with profiles and sections. Drainage and runoff areas, and runoff based on 5,10,25,50 and 100 year rain intensity. Detailed drainage structure design, channel lining design &detention if used. One sheet must show the overall drainage layout of the subdivision. ~Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ~Letter of completion for public infrastructure or guarantee /surety in accordance with UDO Section 8.6. ~Drainage Report with a Technical Design Summary. Erosion Control Plan (must be included in construction plans). All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be provided in recordable form to the City prior to being scheduled for P&Z Commission consideration. E~1 Are there impact fees associated with this development?~Yes El No Impact fees must be paid prior to building permit. ~Will any construction occur in TxDOT rights-of-way?El Yes ~No If yes,TxDOT permit must be submitted along with the construction documents. NOTE:1.We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2.If the construction area is greater than 5 acres,EPA Notice of Intent (NOI)must be submitted prior to issuance of a development permit. Revised 5/15 Page 9 of 9 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 1111 12 12 12 13 13 13 14 14 14 15 15 15 16 16 16 17 17 17 18 18 18 19 19 20 20 21 22 23 24 25 26 27 29 30 31 32 33 COMMONAREA 5COMMON AREA 6COMMON AREA 7 & PRIVATE DRAINAGE EASEMENT 1.348 ACRES Wallaceshir e C o u rtScatterby CoveCainhorn CourtOdell LaneWallaceshire Court Wallaceshire Court Stronghold Cove28 Victoria AvenueVictoria Avenue8 9 8 8 10 9 9 98 989 Odell LaneBLOCK 32 BLOCK 31 BLOCK 34 BLOCK 33 BLOCK 30 BLOCK 29 COMMON AREA 2Victoria AvenueGreens Prairie Road W. BLOCK 29 COMMON AREA 4 & PRIVATE DRAINAGE EASEMENT 0.412 ACRES BLOCK 48 BLOCK 48 BLOCK 48 BLOCK 48 BLOCK 48 BLOCK 49 BLOCK 50BLOCK 50 BLOCK 49 BLOCK 49 PUBLIC ACCESS EASEMENT & COMMON AREA 10 F O R E S T R I D G E D R I V E TBPE NO. 12327 2730 LONGMIRE, SUITE A College Station, Texas 77845  (979) 764-3900 ENGINEER: FINAL PLAT CASTLEGATE II SUBDIVISION SECTION 210 25.489 ACRES ROBERT STEVENSON LEAGUE, A-54 COLLEGE STATION, BRAZOS, TEXAS 71 LOTS BLOCK 48, LOTS 1-33 BLOCK 49, LOTS 1-20 BLOCK 50, LOTS 1-18 COMMON AREAS 5, 6, 7, & 10 SURVEYOR: Brad Kerr, RPLS No. 4502 Kerr Surveying, LLC 409 N. Texas Ave. Bryan, TX 77803 (979) 268-3195 SCALE 1'' = 60' JUNE 2017 OWNER/DEVELOPER: GREENS PRAIRIE INVESTORS, LTD. By Greens Prairie Associates, LLC 4490 Castlegate Drive College Station, TX 77845 (979) 690-7250 LEGEND METES AND BOUNDS DESCRIPTION OF ALL THAT CERTAIN TRACT OR PARCEL OF LAND LYING AND BEING SITUATED IN THE ROBERT STEVENSON LEAGUE, ABSTRACT NO. 54, COLLEGE STATION, BRAZOS COUNTY, TEXAS. SAID TRACT BEING THE REMAINDER OF A CALLED 62.97 ACRE TRACT AS DESCRIBED BY A DEED TO GREENS PRAIRIE INVESTORS, LTD. RECORDED IN VOLUME 12773, PAGE 290 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS. SAID TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING AT A 1/2 INCH IRON ROD FOUND ON THE SOUTHEAST LINE OF VICTORIA AVENUE (77' R.O.W.) MARKING THE WEST CORNER OF BLOCK 33, CASTLEGATE II SUBDIVISION, SECTION 203, ACCORDING TO THE PLAT RECORDED IN VOLUME 11898, PAGE 32 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS, AND THE NORTH CORNER OF SAID REMAINDER OF 62.97 ACRE TRACT; THENCE: S 48° 03' 24" E ALONG THE COMMON LINE OF SAID REMAINDER OF 62.97 ACRE TRACT AND SAID SECTION 203, CASTLEGATE II SUBDIVISION, SECTION 205, ACCORDING TO THE PLAT RECORDED IN VOLUME 12241, PAGE 68 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS, AND CASTLEGATE II SUBDIVISION, SECTION 206, ACCORDING TO THE PLAT RECORDED IN VOLUME 12928, PAGE 38 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS, FOR A DISTANCE OF 1394.33 FEET TO THE NORTH CORNER OF COMMON AREA 4, CASTLEGATE II SUBDIVISION, SECTION 206, ACCORDING TO THE REPLAT RECORDED IN VOLUME 13131, PAGE 71 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS; THENCE: S 13° 02' 31" W ALONG THE COMMON LINE OF SAID REMAINDER OF 62.97 ACRE TRACT AND SAID COMMON AREA 4 FOR A DISTANCE OF 296.67 FEET TO THE NORTHERLY LINE OF SWEETWATER FOREST, PHASE 1, ACCORDING TO THE PLAT RECORDED IN VOLUME 4267, PAGE 254 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS; THENCE: ALONG THE COMMON LINE OF SAID 62.97 ACRE TRACT AND SWEETWATER FOREST, PHASE 1 FOR THE FOLLOWING CALLS: N 81° 31' 25" W FOR A DISTANCE OF 73.15 FEET; N 14° 23' 23" W FOR A DISTANCE OF 95.80 FEET; S 51° 30' 19" W FOR A DISTANCE OF 137.63 FEET; S 23° 33' 08" W FOR A DISTANCE OF 37.67 FEET; N 76° 30' 58" W FOR A DISTANCE OF 82.11 FEET; S 18° 30' 02" W FOR A DISTANCE OF 40.86 FEET; N 71° 55' 53" W FOR A DISTANCE OF 120.56 FEET; N 40° 56' 24" E FOR A DISTANCE OF 47.53 FEET; N 31° 52' 55" W FOR A DISTANCE OF 34.22 FEET; N 70° 11' 07" W FOR A DISTANCE OF 25.11 FEET; S 12° 20' 47" W FOR A DISTANCE OF 83.11 FEET; N 80° 15' 06" W FOR A DISTANCE OF 42.77 FEET; N 27° 06' 14" W FOR A DISTANCE OF 27.52 FEET; N 36° 02' 48" E FOR A DISTANCE OF 78.69 FEET; N 73° 49' 56" W FOR A DISTANCE OF 104.37 FEET; S 80° 01' 10" W FOR A DISTANCE OF 167.78 FEET; N 32° 25' 11" E FOR A DISTANCE OF 51.04 FEET; N 64° 43' 03" W FOR A DISTANCE OF 67.46 FEET; S 11° 54' 33" W FOR A DISTANCE OF 64.33 FEET; S 89° 27' 57" W FOR A DISTANCE OF 28.74 FEET; N 22° 49' 44" W FOR A DISTANCE OF 122.72 FEET; S 57° 18' 15" W FOR A DISTANCE OF 57.18 FEET; N 63° 25' 01" W FOR A DISTANCE OF 64.89 FEET; N 11° 49' 23" W FOR A DISTANCE OF 27.11 FEET; N 77° 25' 22" W FOR A DISTANCE OF 62.42 FEET; S 12° 29' 02" W FOR A DISTANCE OF 33.77 FEET; S 88° 44' 14" W FOR A DISTANCE OF 59.32 FEET; N 02° 25' 01" W FOR A DISTANCE OF 58.17 FEET; S 49° 16' 09" W FOR A DISTANCE OF 85.37 FEET; N 56° 16' 57" W FOR A DISTANCE OF 109.18 FEET; N 66° 50' 42" W FOR A DISTANCE OF 36.65 FEET; S 41° 56' 16" W FOR A DISTANCE OF 152.02 FEET TO THE NORTHEAST LINE OF GREENS PRAIRIE ROAD WEST (VARIABLE WIDTH R.O.W.) FOR THE SOUTHWEST CORNER OF THIS HEREIN DESCRIBED TRACT; THENCE: N 48° 34' 12" W ALONG THE NORTHEAST LINE OF GREENS PRAIRIE ROAD WEST FOR A DISTANCE OF 302.01 FEET TO AN ANGLE POINT IN SAID LINE; THENCE: N 54° 33' 41" W CONTINUING ALONG THE NORTHEAST LINE OF GREENS PRAIRIE ROAD WEST FOR A DISTANCE OF 117.51 FEET TO THE BEGINNING OF A CLOCKWISE CURVE HAVING A RADIUS OF 25.00 FEET; THENCE:ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 96° 29' 34" FOR AN ARC DISTANCE OF 42.10 FEET (CHORD BEARS: N 06° 18' 54" W - 37.30 FEET) TO THE END OF SAID CURVE ON THE EXTENSION OF THE SOUTHEAST LINE OF VICTORIA AVENUE (77' R.O.W.); THENCE: ALONG THE SOUTHEAST LINE OF VICTORIA AVENUE AND THE EXTENSION THEREOF FOR THE FOLLOWING CALLS: N 41° 55' 53" E FOR A DISTANCE OF 82.07 FEET TO THE BEGINNING OF A CLOCKWISE CURVE HAVING A RADIUS OF 611.50 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 09° 30' 09" FOR AN ARC DISTANCE OF 101.42 FEET (CHORD BEARS: N 46° 40' 58" E - 101.30 FEET) TO THE END OF SAID CURVE AND THE BEGINNING OF A CLOCKWISE CURVE HAVING A RADIUS OF 25.00 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 83° 14' 58" FOR AN ARC DISTANCE OF 36.32 FEET (CHORD BEARS: S 86° 56' 28" E - 33.21 FEET) TO THE END OF SAID CURVE AND THE BEGINNING OF A COUNTERCLOCKWISE CURVE HAVING A RADIUS OF 225.00 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 05° 34' 16" FOR AN ARC DISTANCE OF 21.88 FEET (CHORD BEARS: S 48° 06' 07" E - 21.87 FEET) TO THE END OF SAID CURVE; N 39° 06' 45" E FOR A DISTANCE OF 50.00 FEET TO THE BEGINNING OF A CLOCKWISE CURVE HAVING A RADIUS OF 25.00 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 103° 55' 45" FOR AN ARC DISTANCE OF 45.35 FEET (CHORD BEARS: N 01° 04' 37" E - 39.38 FEET) TO THE END OF SAID CURVE; N 53° 02' 30" E FOR A DISTANCE OF 90.53 FEET TO THE BEGINNING OF A COUNTERCLOCKWISE CURVE HAVING A RADIUS OF 688.50 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 11° 06' 01" FOR AN ARC DISTANCE OF 133.39 FEET (CHORD BEARS: N 47° 29' 29" E - 133.18 FEET) TO THE END OF SAID CURVE; N 41° 56' 29" E FOR A DISTANCE OF 538.07 FEET TO THE POINT OF BEGINNING CONTAINING 25.489 ACRES OF LAND, MORE OR LESS, AS SURVEYED ON THE GROUND. BEARING SYSTEM SHOWN HEREIN IS BASED ON GRID NORTH AS ESTABLISHED FROM GPS OBSERVATION. VICINITY MAP NOT TO SCALECASTLEGATE DRIVEW. S . P H I L L I P S P A R K W A Y GREENS PRAIRIE ROADVICTORIA AVENUEGREENS PRAIRIE ROAD WF:\_____15-411 Castlegate II Section 210\FINAL PLAT\Castlegate II Section 210.dwg, Final Plat Planning & Zoning Commission Page 1 of 4 July 20, 2017 FINAL PLAT for The Crossing at Lick Creek, Phase 2 FP2016-000018 SCALE: 43 residential lots and 2 common areas on 22 acres LOCATION: 13500 Rock Prairie Road, generally located south of the William D Fitch Parkway and West of Williams Creek Subdivision. ZONING: R-1B Single-Family Residential APPLICANT: Bernie Bernard PROJECT MANAGER: Mark Bombek, Senior Planner mbombek@cstx.gov RECOMMENDATION: Staff recommends approval of the Final Plat Planning & Zoning Commission Page 2 of 4 July 20, 2017 Planning & Zoning Commission Page 3 of 4 July 20, 2017 Planning & Zoning Commission Page 4 of 4 July 20, 2017 DEVELOPMENT HISTORY Annexation: Part of the property was annexed in 1983, the remaining portion was annexed in 1994 Zoning: A-O Agricultural Open (upon annexation), R1-B Single-Family Residential (2012) Preliminary Plat: Approved in 2015. The approval included the use of fee-in-lieu of sidewalk construction for portions of the sidewalk required along Rock Prairie Road. Site Development: The property has an abandoned oil well site with the majority of the property being vacant and densely vegetated. COMMENTS Parkland Dedication: Fee in lieu of Parkland dedication in the amount of $1,261 per single-family lot will be due prior to filing the Final Plats for this development. Greenways: No greenway dedication is required or proposed. Pedestrian Connectivity: Sidewalks are required on both sides of all streets located within this development. Bicycle Connectivity: Future Bike lanes are anticipated along Rock Prairie Road according to the Bicycle, Pedestrian, and Greenways Master Plan. These bike lanes will be installed with the future reconstruction of Rock Prairie Road. Impact Fees: This tract is subject to citywide impact fees: water, sanitary sewer, and roadway. Impact fees will be dependent upon timing of the building permit application date. REVIEW CRITERIA 1. Compliance with Comprehensive Plan and Unified Development Ordinance: The subject property is classified as Restricted Suburban on the Comprehensive Plan Future Land Use and Character Map. The tract is currently governed by R1-B Single- Family Residential zoning district. The Final Plat is in compliance with the applicable sections of the Unified Development Ordinance (UDO). 2. Compliance with Subdivision Regulations: The proposed Final Plat is in compliance with the approved Preliminary Plan and Subdivision Regulations. STAFF RECOMMENDATIONS Staff recommends approval of the Final Plat. SUPPORTING MATERIALS 1. Application 2. Copy of Final Plat (4 ~‘~FOR OFFICE USE ONLY CASE NO.:________________ DATE SUBMITTED:_____________ CITY OF COLLEGE STATION TIME: Home of TexajA?,M University’STAFF:_______________________ FINAL PLAT APPLICATION (Check one)~Minor ~Amending ~Final ~Vacating ~Replat ($700)($700)($932)($932)($932) Is this plat in the ETJ?~Yes ~No Is this plat Commercial ~or Residential ~ MINIMUM SUBMITTAL REQUIREMENTS: $700-$932 Final Plat Application Fee (see above). $233 Waiver Request to Subdivision Regulations Fee (if applicable). $600 (minimum)Development Permit Application I Public Infrastructure Review and Inspection Fee. Fee is 1%of acceptable Engineer’s Estimate for public infrastructure,$600 minimum (if fee is>$600,the balance is due prior to the issuance of any plans or development permit). ~Application completed in full.This application form provided by the City of College Station must be used and may not be adjusted or altered.Please attach pages if additional information is provided. Copy of plat.(A signed mylar original must be submitted after approval.) Grading,drainage,and erosion control plan with supporting drainage report. Public infrastructure plan and supporting documents (if applicable). Copy of original deed restrictions/covenants for replats (if applicable). Title report for property current within ninety (90)days or accompanied by a Nothing Further Certificate current within ninety (90) days.The report must include applicable information such as ownership,liens, encumbrances,etc. ~The attached Final Plat checklist with all items checked off or a brief explanation as to why they are not. NOTE:A paid tax certificates from City of College Station, Brazos County and College Station I.S.D.will be due at the time of the mylar submittal prior to filing the plat. Date of Optional Preapplication or Stormwater Management Conference 1-21-2015 NAME OF PROJECT The Crossing at Lick Creek,Phase 2 ADDRESS 13500 Rock Prairie Rd E SPECIFIED LOCATION OF PROPOSED PLAT: Rock Prairie Road East adjacent to Lick Creek Park APPLICANT/PROJECT MANAGER’S INFORMATION (Primary contact for the project): Name Bernie Bernard E-mail berniebernard@tdi-bi.com Street Address 14391 S.Dowling Road City College Station State ~Zip Code 77845 Phone Number (979)2203804 Fax Number _______________________________ Revised 5/15 Page 1 of 9 PROPERTY OWNERS INFORMATION (All owners must be identified.Please attach an additional sheet for multiple owners): Name TDI-B rooks Developments, LLC E-mail berniebernard~tdi-bL corn Street Address 14391 S.Dowling Road City College Station State ~Zip Code 77845 Phone Number (979)220-3804 Fax Number _________________________________ ARCHITECT OR ENGINEER’S INFORMATION: Name Schultz Engineering, LLC -Joe Schultz E-mail /oe~schultzeng.com Street Address 2730 Longrnire Drive,Suite A City College Station State 7)<’Zip Code 77842 Phone Number (979)7643900 Fax Number (979)764 -3910 Do any deed restrictions or covenants exist for this property?IZ~Yes ~No Is there a temporary blanket easement on this property?If so,please provide the Volume 130 3Z.and Page No.51/ Total Acreage 22.063 Total No.of Lots 43 R-O-WAcreage 3.134 Existing Use Vacant Proposed Use Residential Number of Lots By Zoning District 43 I RS I I _______ Average Acreage Of Each Residential Lot By Zoning District: 0.360 /RS ______ ______ ______,,,______ Floodplain Acreage 0 Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels)on the property?fl Yes ~No This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance.Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s)and you are requesting the application be reviewed under previous ordinance as applicable? ~Yes flNo If yes,provide information regarding the first approved application and any related subsequent applications (provide additional sheets if necessary): Project Name:The Crossing at Lick Creek (PP) City Project Number (if known):PP2OI 5-900097 Date!Timeframe when submitted:March 2015 Revised 5/15 Page 2 of 9 A statement addressing any differences between the Final Plat and Preliminary Plan (if applicable): IA Requested waiver to subdivision regulations and reason for same (if applicable): VIA Regarding the waiver request,explain how: 1.There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land. 2.The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant. 3.The granting of the waiver will not be detrimental to the public health,safety,or welfare,or injurious to other property in the area,or to the City in administering subdivision regulations. Fee in lieu of sidewalk construction is being requested because of the following condition (if applicable): 1.fl An alternative pedestrian way or multi-use path has been or will be provided outside the right-of-way; 2.fl The presence of unique or unusual topographic, vegetative,or other natural conditions exist so that strict adherence to the sidewalk requirements of the UDO is not physically feasible or is not in keeping with the purposes and goals of the UDO or the City’s comprehensive Plan; 3.~A capital improvement project is imminent that will include construction of the required sidewalk.Imminent shall mean the project is funded or projected to commence within twelve (12)months; 4.fl Existing streets constructed to rural section that are not identified on the Thoroughfare Plan with an estate / rural context; 5.fl When a sidewalk is required along a street where a multi-use path is shown on the Bicycle,Pedestrian,and Greenways Master Plan; 4.The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the Drovisions of the Unified Development Ordinance. Revised 5/15 Page 3 of 9 6.fl The proposed development is within an older residential subdivision meeting the criteria in Platting and Replatting within Older Residential Subdivisions Section of the UDO;or 7.E The proposed development contains frontage on a Freeway I Expressway as designated by Map 6.6, Thoroughfare Plan -Functional Classification,in the City’s Comprehensive Plan. Detailed explanation of condition identified above: NOTE:A waiver to the sidewalk requirements and fee in lieu of sidewalk construction shall not be considered at the same time by the Planning &Zoning Commission. Requested Oversize Participation Watedme -8”to 12” Total Linear Footage of Parkland Dedication due prior to filing the Final Plat: Proposed Public: ACREAGE:2838 Streets No.of acres to be dedicated +$_________development fee ~Sidewalks _______No.of acres in floodplain1865_Sanitary Sewer Lines No.of acres in detention2389_Water Lines No.of acres in greenways813Channels OR1868StormSewers FEE IN LIEU OF LAND: Bike Lanes I Paths ‘~3 No.of SF Dwelling Units X $_1261 =$54,180 3312015 (date)Approved by Parks &Recreation Advisory Board NOTE:DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true,correct,and complete.IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY,this application must be accompanied by a power of attorney statement from the owner.If there is more than one owner,all owners must sign the application or the power of attorney.If the owner is a company,the application must be accompanied by proof of authority for the company’s representative to sign the application on its behalf.LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above. -Ji14~)4(JA1~4f~~oi~ ignature and ti 1€6’)‘j,≤~,t..Date Revised 5/15 Page 4 of 9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1.No work of any kind may start until a permit is issued. 2.The permit may be revoked if any false statements are made herein. 3.If revoked,all work must cease until permit is re-issued. 4.Development shall not be used or occupied until a Certificate of Occupancy is issued. 5.The permit will expire if no significant work is progressing within 24 months of issuance. 6.Other permits may be required to fulfill local,state,and federal requirements.Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOl and SWPPP. 7.If required,Elevation Certificates will be provided with elevations certified during construction (forms at slab pre pour) and post construction. 8.Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9.If,stormwater mitigation is required,including detention ponds proposed as part of this project,it shall be designed and constructed first in the construction sequence of the project. 10.In accordance with Chapter 13 of the Code of Ordinances of the City of College Station,measures shall be taken to insure that all debris from construction,erosion,and sedimentation shall not be deposited in city streets, or existing drainage facilities.All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 11.The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the City of College Station,Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications,and Standard Details. All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12.Release of plans to __________________________________ (name or firm)is authorized for bidding purposes only.I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13.I,THE OWNER,AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION,ARE,TO THE BEST OF MY KNOWLEDGE,TRUE,AND ACC1J~ATE./ )~j~V~EF~~-~~i( ~f~erty Owner(s)TOL%1OO1~≤Date OV~L~o/#.5~1≤LL~ Engineer Certification: 1.The project has been designed to ensure that stormwater mitigation,including detention ponds,proposed as part of the project will be constructed first in the construction sequence. 2.I will obtain or can show compliance with all necessary Local,State and Federal Permits prior to construction including NOI and SWPPP.Design will not preclude compliance with TPDES:i.e.,projects over 10 acres may require a sedimentation basin. 3.The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines.All develoi in accordance with all applicable codes and ordinances of the City of College Station ulations. 4.I,THE ENGINEER,AGREE 1 LL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT E,TO THE BEST OF MY KNOWLEDGE,TRUE,AND TE. — Date Revised 5/15 Page 5 of 9 The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans,Final Plats,Construction Plans,Fill I Grading Permits,and Clearing Only Permits :* A.I,_______________________________________certify, as demonstrated in the attached drainage study,that the alterations or development covered by this permit,shall not: (i)increase the Base Flood elevation; (ii)create additional areas of Special Flood Hazard Area; (iii)decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the velocity of flow in the Base Flood event is greater than one foot per second.This area can also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the depth of from the BFE to natural ground is 18 inches or greater; (iv)reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than one foot per second without acceptable compensation as set forth in the City of College Station Code of Ordinances, Chapter 13 concerning encroachment into the Special Flood Hazard Area; nor (v)increase Base Flood velocities. beyond those areas exempted by ordinance in Section 5.11 .3a of Chapter 13 Code of Ordinances. Engineer Date Initial *If a platting-status exemption to this requirement is asserted, provide written justification under separate ______letter in lieu of certification. Required for Site Plans,Final Plats,Construction Plans,and Fill I Grading Permits: B.I,_______________________________,certifytothefollowing: (i)that any nonresidential or multi-family structure on or proposed to be on this site as part of this application is designed to prevent damage to the structure or its contents as a result of flooding from the 100-year storm. Engineer Date Additional certification for Floodway Encroachments: C.I,_______________________________________,certify that the construction, improvement,or fill covered by this permit shall not increase the base flood elevation.I will apply for a variance to the Zoning Board of Adjustments. Engineer Date Revised 5/15 Page 6 of 9 Required for all projects proposing structures in Special Flood Hazard Area (Elevation Certificate required). Residential Structures: D.I,_______________________________________certify that all new construction or any substantial improvement of any residential structure shall have the lowest floor,including all utilities,ductwork and any basement,at an elevation at least one foot above the Base Flood Elevation. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre-pour)and post construction. Engineer I Surveyor Date Commercial Structures: E.I,_______________________________________,certify that all new construction or any substantial improvement of any commercial, industrial, or other non-residential structure are designed to have the lowest floor,including all utilities,ductwork and basements,elevated at least one foot above the Base Flood Elevation Engineer!Surveyor Date OR I,____________________________________________,certify that the structure with its attendant utility,ductwork, basement and sanitary facilities is designed to be flood-proofed so that the structure and utilities,ductwork, basement and sanitary facilities are designed to be watertight and impermeable to the intrusion of water in all areas below the Base Flood Elevation,and shall resist the structural loads and buoyancy effects from the hydrostatic and hydrodynamic conditions. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre pour) and post construction. Engineer!Surveyor Date Conditions or comments as part of approval:_______________________________________________________________ Revised 5/15 Page 7 of 9 FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) ~Drawn on 24”x 36”sheet to scale of 100 per inch. ~Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits.No scale required but include north arrow. ~Title Block with the following information: ~Name and address of subdivider,recorded owner, planner,engineer and surveyor. ~Proposed name of subdivision. (Subdivision name &street names will be approved through Brazos County 911.) ~Date of preparation. ~Engineer’s scale in feet. ~Total area intended to be developed. ~North Arrow. ~Subdivision boundary indicated by heavy lines. ~If more than I sheet,an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. ~All applicable certifications based on the type of final plat. ~Ownership and Dedication ~Surveyor and/or Engineer ~City Engineer (and City Planner,if a minor plat) ~Planning and Zoning Commission (delete if minor plat) ~Brazos County Clerk ~Brazos County Commissioners Court Approval (ETJ Plats only) ~If submitting a replat where there are existing improvements,submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. ~If using private septic systems,add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner’s Court of Brazos County,pursuant to the provisions of Section 21.084 of the Texas Water Code. ~Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent available data. ~Lot corner markers and survey monuments (by symbol)and clearly tied to basic survey data. ~Matches the approved preliminary plan or qualifies as minor amendments (UDO Section 3.3.E.2). ~The location and description with accurate dimensions, bearings or deflection angles and radii, area,center angle,degree of curvature,tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision,as well as,those within the subdivision). Existing Proposed Streets.Continuous or end in a cul-de-sac,stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. ~Public and private R.O.W.locations and widths.(All existing and proposed R.O.W.’s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Revised 5/15 Page 8 of 9 Existing Proposed D Alleys. Easements. ~A number or letter to identify each lot or site and each block (numbered sequentially). ~Parkland dedication/greenbelt area/park linkages.All proposed dedications must be reviewed by the Parks and Recreation Advisory Board and documentation of their recommendation provided prior to being scheduled for P&Z Commission consideration. ~Construction documents for all public infrastructure drawn on 24”x 36”sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: ~Street,alley and sidewalk plans,profiles and sections.One sheet must show the overall street,alley and/or sidewalk layout of the subdivision.(may be combined with other utilities). Sewer Design Report. Sanitary sewer plan and profile showing depth and grades.One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water Design Report and/or Fire Flow Report. Water line plan showing fire hydrants, valves,etc.with plan and profile lines showing depth and grades.One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours,street profile,inlets,storm sewer and drainage channels, with profiles and sections.Drainage and runoff areas,and runoff based on 5,10,25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design &detention if used.One sheet must show the overall drainage layout of the subdivision. ~Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ~Letter of completion for public infrastructure or guarantee /surety in accordance with UDO Section 8.6. ~Drainage Report with a Technical Design Summary. Erosion Control Plan (must be included in construction plans). ~All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be provided in recordable form to the City prior to being scheduled for P&Z Commission consideration. ~Are there impact fees associated with this development?D Yes D No Impact fees must be paid prior to building permit. ~Will any construction occur in TxDOT rights-of-way?~Yes ~No If yes,TxDOT permit must be submitted along with the construction documents. NOTE:1.We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2.If the construction area is greater than 5 acres,EPA Notice of Intent (NOl) must be submitted prior to issuance of a development permit. Print Form Revised 5/15 Page 9 of 9 Planning & Zoning Commission July 20, 2017 Page 1 of 9 Final Plat for Rio Grande Subdivision Lot 1 Block 1, Lots 1-14 Block 2, Lots 1-3 Block 3 and Lots 1-41 Block 4 FP2015-000004 SCALE: 67 residential lots and 2 common areas on approximately 7.24 acres LOCATION: 2021 Harvey Mitchell Parkway S, generally located northeast of the intersection of Harvey Mitchell Parkway South with Rio Grande Blvd, and west of Southwood Drive. ZONING: T Townhouse and NAP Natural Areas Protected APPLICANT: Veronica Morgan, Mitchell & Morgan, LLP PROJECT MANAGER: Mark Bombek, Senior Planner mbombek@cstx.gov RECOMMENDATION: Staff recommends approval of the Final Plat. Planning & Zoning Commission July 20, 2017 Page 2 of 9 Planning & Zoning Commission July 20, 2017 Page 3 of 9 Planning & Zoning Commission July 20, 2017 Page 4 of 9 DEVELOPMENT HISTORY Annexation: 1969 Zoning: Neighborhood Business District C-N upon annexation Partially rezoned Townhouse-Rowhouse District R-3 (1978) Rezoned T Townhouse and NAP Natural Areas Protected (2014) Site development: In 2008, a preliminary plan was approved for an 8.255 acre tract containing this piece of property. However, a final plat was never submitted. A new preliminary plan was approved May 21, 2015 and infrastructure has been constructed as noted below. COMMENTS Parkland Dedication Fees: Parkland dedication fees in the $1,636 per townhouse lot is will be collected prior to filing the Final Plat for this development. Greenways: None proposed or required for this development. Property adjacent to Bee Creek Tributary B, which includes property zoned NAP Natural Areas Protected and 100-year floodplain, is being platted as Common Area and for detention. Pedestrian Connectivity: Sidewalks are required for this development along both sides of all streets within the development except for alleys and the bulb of the cul-de-sac. Bicycle Connectivity: There is an existing multi-use path along Harvey Mitchell Parkway South. There is also a future multi-use path that is expected to run along the western boundary of this property through the Bee Creek Tributary B. No portion of the proposed multi-use path is required to be built with this development. Impact Fees: The tract is subject to citywide impact fees: water, sanitary sewer, and roadway. Impact fees will be dependent upon timing of the building permit application date. REVIEW CRITERIA 1. Compliance with the Comprehensive Plan and Unified Development Ordinance: The majority of the property is classified as Urban on the Comprehensive Plan Future Land Use and Character Map, and a small portion along the creek is designated Natural Areas- Reserved. The plat meets the respective minimum requirements for T Townhouse and NAP Natural Areas Protected zoning. 2. Compliance with Subdivision Regulations: The proposed Final Plat is in compliance with the previously approved Preliminary Plan and the Subdivision Regulations contained in the Unified Development Ordinance. Planning & Zoning Commission July 20, 2017 Page 5 of 9 STAFF RECOMMENDATION Staff recommends approval of the Final Plat. SUPPORTING MATERIALS 1. Application 2. Copy of Final Plat Planning & Zoning Commission July 20, 2017 Page 1 of 5 Final Plat for Harvey Road Subdivision Phase 1 FP2017-000009 SCALE: 1 lot and 2 common areas on approximately 17 acres LOCATION: 3210 Harvey Road, generally located west of the intersection of State Highway 30 and Linda Lane. ZONING: MF Multi-Family and NAP Natural Areas Protected APPLICANT: Jon Belanger, Cypressbrook Company PROJECT MANAGER: Mark Bombek, Senior Planner mbombek@cstx.gov RECOMMENDATION: Staff recommends approval of the Final Plat. Planning & Zoning Commission July 20, 2017 Page 2 of 5 Planning & Zoning Commission July 20, 2017 Page 3 of 5 Planning & Zoning Commission July 20, 2017 Page 4 of 5 DEVELOPMENT HISTORY Annexation: June 1980 Zoning: A-O Agricultural Open upon annexation renamed R Rural in 2013, Portion rezoned to GC General Commercial and NAP Natural Area Protected in 2016, Remaining portion rezoned to MF Multi-Family and NAP Natural Area Protected in 2017 Preliminary Plan: Approved in April of 2017. The approval included a request to pay fee-in-lieu of sidewalk construction for a portion along Harvey Road in phase 2 of this development. Site development: Vacant COMMENTS Parkland Dedication: Fee in lieu of Parkland dedication in the amount of $687.00 per bedroom will be due prior to the issuance of building permits for the multi-family portion of this plan. Greenways: N/A Pedestrian Connectivity: A six foot wide sidewalk will be constructed along Harvey Road the entire length of Phase 1. Bicycle Connectivity: The Bicycle, Pedestrian and Greenways Master Plan identifies Harvey Road as an existing bicycle route. Separated bike lanes are not proposed for this roadway at this time. Oversize Request: N/A Impact Fees: This tract is subject to citywide impact fees: water, sanitary sewer, and roadway. Impact fees will be dependent upon timing of the building permit application date. REVIEW CRITERIA 1. Compliance with Comprehensive Plan and Unified Development Ordinance: The subject property is classified as Urban on the Comprehensive Plan Future Land Use and Character Map. The tract is currently governed by two different zoning districts be MF Multi-Family and NAP Natural Areas Protected. The Final Plat is in compliance with the applicable sections of the Unified Development Ordinance (UDO). Planning & Zoning Commission July 20, 2017 Page 5 of 5 2. Compliance with Subdivision Regulations: The proposed Final Plat is in compliance with the approved preliminary plan and Subdivision Regulations. STAFF RECOMMENDATION Staff recommends approval of Final Plat SUPPORTING MATERIALS 1. Application 2. Copy of Final Plat $600 (minimum) Development Permit Application / Public Infrastructure Review and Inspection Fee. Fee is 1% of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is > $600, the balance is due prior to the issuance of any plans or development permit). Application completed in full. This application form provided by the City of College Station must be used and may not be adjusted or altered. Please attach pages if additional information is provided. $700-$932 Final Plat Application Fee (see above). $233 Waiver Request to Subdivision Regulations Fee (if applicable). Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate current within ninety (90) days. The report must include applicable information such as ownership, liens, encumbrances, etc. Copy of plat. (A signed mylar original must be submitted after approval.) Copy of original deed restrictions/covenants for replats (if applicable). FINAL PLAT APPLICATION (Check one) Minor Amending Final Vacating Replat Is this plat in the ETJ? MINIMUM SUBMITTAL REQUIREMENTS: NOTE: A paid tax certificates from City of College Station, Brazos County and College Station I.S.D. will be due at the time of the mylar submittal prior to filing the plat. Is this plat Commercial No ($700)($700)($932)($932)($932) The attached Final Plat checklist with all items checked off or a brief explanation as to why they are not. APPLICANT/PROJECT MANAGER'S INFORMATION (Primary contact for the project): Name E-mail Street Address City State Zip Code Phone Number Fax Number Revised 5/15 Page 1 of 9 Date of Optional Preapplication or Stormwater Management Conference SPECIFIED LOCATION OF PROPOSED PLAT: ADDRESS NAME OF PROJECT FOR OFFICE USE ONLY CASE NO.: DATE SUBMITTED: TIME: STAFF: Public infrastructure plan and supporting documents (if applicable). Grading, drainage, and erosion control plan with supporting drainage report. or Residential Cypressbrook Company - Jon Belanger jbelanger@cypressbrook.com 1776 Woodstead Court, Suite 218 The Woodlands TX 77380 832.403.2864 October 19, 2016 Southeast Side of Harvey Road Between Veterans Parkway and Linda Lane 000801-0004-0040 Harvey Road Subdivision ARCHITECT OR ENGINEER'S INFORMATION: Is there a temporary blanket easement on this property? If so, please provide the Volume and Page No. Do any deed restrictions or covenants exist for this property? Total Acreage Total No. of Lots R-O-W Acreage Existing Use Proposed Use Average Acreage Of Each Residential Lot By Zoning District: / / / / Number of Lots By Zoning District / / / Floodplain Acreage Name E-mail Street Address City State Zip Code Phone Number Fax Number Yes No Revised 5/15 Page 2 of 9 Street Address PROPERTY OWNER'S INFORMATION (All owners must be identified. Please attach an additional sheet for multiple owners): Name E-mail City State Zip Code Phone Number Fax Number NoYesIs there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? This information is necessary to help staff identify the appropriate standards to review the application and will be used to help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made, vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law. Is this application a continuation of a project that has received prior City platting approval(s) and you are requesting the application be reviewed under previous ordinance as applicable? If yes, provide information regarding the first approved application and any related subsequent applications (provide additional sheets if necessary): Project Name: Date / Timeframe when submitted: City Project Number (if known): 16.845 1 0.173 Vacant Residential 4.441 1 MF 10.590 Schultz Engineering, LLC - Joe Schultz, PE eng@schultzeng.com 911 Southwest Parkway E College Station TX 77840 979.764.3900 979.764.3910 MF 1776 Woodstead Court, Suite 218 Cypressbrook Harvey Road, LP jbelanger@cypressbrook.com The Woodlands TX 77381 832.403.2864 4. The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in accordance with the provisions of the Unified Development Ordinance. Fee in lieu of sidewalk construction is being requested because of the following condition (if applicable): An alternative pedestrian way or multi-use path has been or will be provided outside the right-of-way; The presence of unique or unusual topographic, vegetative, or other natural conditions exist so that strict adherence to the sidewalk requirements of the UDO is not physically feasible or is not in keeping with the purposes and goals of the UDO or the City's comprehensive Plan; A capital improvement project is imminent that will include construction of the required sidewalk. Imminent shall mean the project is funded or projected to commence within twelve (12) months; Revised 5/15 Page 3 of 9 3. The granting of the waiver will not be detrimental to the public health, safety, or welfare, or injurious to other property in the area, or to the City in administering subdivision regulations. A statement addressing any differences between the Final Plat and Preliminary Plan (if applicable): Requested waiver to subdivision regulations and reason for same (if applicable): Regarding the waiver request, explain how: 1. There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land. 2. The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant. When a sidewalk is required along a street where a multi-use path is shown on the Bicycle, Pedestrian, and Greenways Master Plan; Existing streets constructed to rural section that are not identified on the Thoroughfare Plan with an estate / rural context; 5. 4. 3. 2. 1. N/A N/A N/A N/A N/A N/A 6.[]The proposed development is within an older residential subdivision meeting the criteria in Platting and Replatting within Older Residential Subdivisions Section of the UDO;or 7.U The proposed development contains frontage on a Freeway /Expressway as designated by Map 6.6, Thoroughfare Plan -Functional Classification,in the City’s Comprehensive Plan. NOTE:A waiver to the sidewalk requirements and fee in lieu of sidewalk construction shall not be considered at the same time by the Planning &Zoning Commission. Requested Oversize Participation~ NOTE:DIGITAL COPY OF FLAT MUST BE SUBMITIED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true,coirecL~and complete.IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY,this application must be accompanied by a power of attorney statement from the owner.if there is more than one owner,all owners must sign the application or the power of attorney.if the owner is a company, the application must be accompanied by proof of authority for the company’s representative to sign the application on its behaff.LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above. Date 5’/~~’~±~- of condition identified above: ACREAGE: Parkiand Dedication due prior to filing the Final Plat:Total Linear Footage of Proposed Public: N/A_Streets 1442_Sidewalks N/A_Sanitary Sewer Lines N/A_Water Lines N/A_Channels N/A Storm Sewers N/A_Bike Lanes I Paths N/A No.of acres to be dedicated +$_________ N/A No.of acres in floodplain N/A No.of acres in detention development fee N/A No.of acres in greenways OR FEE IN LIEU OF LAND: No.of SF Dwelling Units X $______=$ N/A (date)Approved by Parks &Recreation Advisory Board Signature and title Vi~e ~~ Revised 5115 Page 4 of 9 CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT Owner Certification: 1.No work of any kind may start until a permit is issued. 2.The permit may be revoked if any false statements are made herein. 3.If revoked,alt work must cease until permit is re-issued. 4.Development shall not be used or occupied until a Certificate of Occupancy is issued. 5.The permit will expire if no significant work is progressing within 24 months of issuance. 6.Other permits may be required to fulfill local,state,and federal requirements.Owner will obtain or show compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP. 7.If required,Elevation Certificates will be provided with elevations certified during construction (forms at slab pit- pour)and post construction. 8.Owner hereby gives consent to City representatives to make reasonable inspections required to verify compliance. 9.If,stormwater mitigation is required, including detention ponds proposed as part of this project,it shall be designed and constructed first in the construction sequence of the project. 10. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station,measures shall be taken to insure that all debris from construction, erosion,and sedimentation shall not be deposited in city streets,or existing drainage facilities.All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project.All of the applicable codes and ordinances of the City of College Station shall apply. 11.The information and conclusions contained in the attached plans and supporting documents will comply with the current requirements of the CIty of College Station, Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines Technical Specifications,and Standard Details.All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 12.Release of plans to _________________________________(name or firm)is authorized for bidding purposes only.I understand that final approval and release of plans and development for construction is contingent on contractor signature on approved Development Permit. 13.I,THE OWNER,AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION,ARE,TO THE BEST OF MY KNOWLEDGE,TRUE,AND ACCURATE. ~_____________ Property Owner(s)Date Engineer Certification: 1.The project has been designed to ensure that stormwater mitigation,including detention ponds,proposed as part of the project will be constructed first in the construction sequence. 2.1 will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction including NOI and SWPPP. Design will not preclude compliance with TPDES:i.e.,projects over 10 acres may require a sedimentation basin. 3.The information and conclusions contained in the attached plans and supporting documents comply with the current requirements of the City of College Station,Texas City Code,Chapter 13 and associated BCS Unified Design Guidelines.All development has been designed in accordance with all applicable codes and ordinances of the City of College Station and State and Federal Regulations. 4.1,THE ENGINEER,AGREE TO AND CERTIFY THAT ALL STATEMENTS HEREIN,AND IN ATTACHMENTS FOR THE DEVELOPMENT PERMIT APPLICATION,ARE,TO THE BEST OF MY KNOWLEDGE, TRUE, AND ACCURATE. ___o&/o’/17 Date Page 5 of 9Revised 5/15 C— C The following CERTIFICATIONS apply to development in Special Flood Hazard Areas. Required for Site Plans,Final Plats,Construction Plans,Fill I Grading Permits,and Clearing Only Permits:* A.I,____________________________________certify,as demonstrated in the attached drainage study,that the alterations or development covered by this permit,shall not: (i)increase the Base Flood elevation; (ii)create additional areas of Special Flood Hazard Area; (iii)decrease the conveyance capacity to that part of the Special Flood Hazard Area that is not in the floodway and where the velocity of flow in the Base Flood event is greater than one foot per second.This area can also be approximated to be either areas within 100 feet of the boundary of the regulatory floodway or areas where the depth of from the BFE to natural ground is 18 inches or greater~ (iv)reduce the Base Flood water storage volume to the part of the Special Flood Hazard Area that is beyond the floodway and conveyance area where the velocity of flow in the Base Flood is equal to and less than one foot per second without acceptable compensation as set forth in the City of College Station Code of Ordinances, Chapter 13 concerning encroachment into the Special Flood Hazard Area;nor (v)increase Base Flood velocities. beyond those areas exempted by ordinance in Section 5.11 .3a of Chapter 13 Code of Ordinances. ô~~/oijr7 Engineer Date Initial *If a platting-status exemption to this requirement is asserted, provide written justification under separate ______letter in lieu of certification. Required for Site Plans,Final Plats,Construction Plans,and Fill I Grading Permits~ B.I,________________________________,certify to the following: (i)that any nonresidential or multi-family structure on or proposed to be on this site as part of this application is designed to prevent damage to the structure or its contents as a result of flooding from the 100-year storm. ...........................-~———.~2~J0I/17 Engineer Date Additional certification for Floodway Encroachments: C.I,D~r~ç)o~j E~i’J ,certify that the construction,improvement,or fill covered by this permit shall not increase the base flood elevation.I will apply for a variance to the Zoning Board of Adjustments. 1 ~m.___________________________ Engineer Date Revised 5/15 Page 6 af 9 , certify that all new construction or any substantial improvement of any residential structure shall have the lowest floor, including all utilities, ductwork and any basement, at an elevation at least one foot above the Base Flood Elevation. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre-pour) and post construction. D. I, Engineer / Surveyor Date Conditions or comments as part of approval: Required for all projects proposing structures in Special Flood Hazard Area (Elevation Certificate required). Page 7 of 9Revised 5/15 E. I, , certify that all new construction or any substantial improvement Commercial Structures: Residential Structures: of any commercial, industrial, or other non-residential structure are designed to have the lowest floor, including all utilities, ductwork and basements, elevated at least one foot above the Base Flood Elevation DateEngineer / Surveyor OR basement and sanitary facilities is designed to be flood-proofed so that the structure and utilities, ductwork, basement and sanitary facilities are designed to be watertight and impermeable to the intrusion of water in all areas below the Base Flood Elevation, and shall resist the structural loads and buoyancy effects from the hydrostatic and hydrodynamic conditions. Required Elevation Certificates will be provided with elevations certified during construction (forms at slab pre- pour) and post construction. DateEngineer / Surveyor I, , certify that the structure with its attendant utility, ductwork, If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) North Arrow. Subdivision boundary indicated by heavy lines. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.084 of the Texas Water Code. Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent available data. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. Matches the approved preliminary plan or qualifies as minor amendments (UDO Section 3.3.E.2). The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Revised 5/15 Page 8 of 9 Ownership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) Planning and Zoning Commission (delete if minor plat) Brazos County Clerk Brazos County Commissioners Court Approval (ETJ Plats only) All applicable certifications based on the type of final plat. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. Drawn on 24" x 36" sheet to scale of 100' per inch. Title Block with the following information: Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) Name and address of subdivider, recorded owner, planner, engineer and surveyor. Date of preparation. Engineer's scale in feet. Total area intended to be developed. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. Alleys. Easements. A number or letter to identify each lot or site and each block (numbered sequentially). Parkland dedication/greenbelt area/park linkages. All proposed dedications must be reviewed by the Parks and Recreation Advisory Board and documentation of their recommendation provided prior to being scheduled for P&Z Commission consideration. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). Sewer Design Report. Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water Design Report and/or Fire Flow Report. Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. Drainage Report with a Technical Design Summary. Erosion Control Plan (must be included in construction plans). All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be provided in recordable form to the City prior to being scheduled for P&Z Commission consideration. Are there impact fees associated with this development? Impact fees must be paid prior to building permit. Will any construction occur in TxDOT rights-of-way? If yes, TxDOT permit must be submitted along with the construction documents. Yes No Yes No Letter of completion for public infrastructure or guarantee / surety in accordance with UDO Section 8.6. Existing Proposed Revised 5/15 Page 9 of 9 STATE HIGHWAY 3 0 ( H A R V E Y R O A D ) COMMON AREA 2 & PRIVATE DRAINAGE EASEMENT COMMON AREA 1 & PRIVATE DRAINAGE EASEMENT LOT 1 11.23 AC. BLOCK 1 1.76 AC. 3.86 AC. STATE HIGHWAY 30 (HARVEY ROAD)BFE: 258'BFE: 260'BFE: 262 ' TBPE NO. 12327 911 SOUTHWEST PKWY E. College Station, Texas 77840  (979) 764-3900 ENGINEER: FINAL PLAT HARVEY ROAD SUBDIVISION PHASE 1 16.845 ACRES RICHARD CARTER LEAGUE, A-8 COLLEGE STATION, BRAZOS, TEXAS PHASE 1 1 LOT BLOCK 1, LOT 1 COMMON AREAS 1 & 2 SCALE 1'' = 60' JULY 2017 LEGEND LEGEND VICINITY MAP NOT TO SCALE HARVEY ROADLI N D A L A N E RANCHERO ROADCITY LIMIT LINESURVEYOR: Brad Kerr, RPLS No. 4502 Kerr Surveying, LLC 409 N. Texas Ave. Bryan, TX 77803 (979) 268-3195 OWNER Cypressbrook Harvey Road, LP 1776 Woodstead Court, Suite 218 The Woodlands, TX 77380 832.403.2864 DEVELOPER: Cypressbrook Company 1776 Woodstead Court, Suite 218 The Woodlands, TX 77380 832.403.2864 METES AND BOUNDS DESCRIPTION OF A 16.845 ACRE TRACT RICHARD CARTER LEAGUE, A-8 COLLEGE STATION, BRAZOS COUNTY, TEXAS METES AND BOUNDS DESCRIPTION OF ALL THAT CERTAIN TRACT OR PARCEL OF LAND LYING AND BEING SITUATED IN THE RICHARD CARTER LEAGUE, ABSTRACT NO. 8, COLLEGE STATION, BRAZOS COUNTY, TEXAS. SAID TRACT BEING A PORTION OF THE REMAINDER OF A CALLED 28.57 ACRE TRACT OF LAND AS DESCRIBED BY A DEED TO THE SUMMIT CROSSING, LLC RECORDED IN VOLUME 8491, PAGE 52 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS, AND ALL OF A CALLED 11.37 ACRE TRACT AS DESCRIBED BY A DEED TO KATE ROMAIN RECORDED IN VOLUME 8499, PAGE 21 OF THE OFFICIAL PUBLIC RECORDS OF BRAZOS COUNTY, TEXAS. SAID TRACT BEING MORE PARTICULARLY DESCRIBED BY METES AND BOUNDS AS FOLLOWS: BEGINNING AT A 1/2 INCH IRON ROD FOUND ON THE SOUTHWEST LINE OF LOT 2, BLOCK 3, HARVEY HILLSIDES, ACCORDING TO THE PLAT RECORDED IN VOLUME 263, PAGE 489 OF THE DEED RECORDS OF BRAZOS COUNTY, TEXAS, MARKING THE NORTH CORNER OF LOT 8, BLOCK 3, AND THE EAST CORNER OF SAID 11.37 ACRE TRACT; THENCE: ALONG THE COMMON LINE OF SAID 11.37 ACRE TRACT AND SAID REMAINDER OF 28.57 ACRE TRACT AND SAID BLOCK 3 FOR THE FOLLOWING CALLS: S 42° 10' 40" W FOR A DISTANCE OF 362.71 FEET TO A 1/2 INCH IRON ROD FOUND MARKING THE WEST CORNER OF SAID LOT 8 AND THE NORTH CORNER OF LOT 10, BLOCK 3; S 41° 02' 24" W FOR A DISTANCE OF 370.11 FEET TO A 1/2 INCH IRON ROD FOUND MARKING THE WEST CORNER OF SAID LOT 10 AND THE NORTH CORNER OF LOT 12, BLOCK 3; S 41° 11' 42" W FOR A DISTANCE OF 369.83 FEET TO A 1/2 INCH IRON ROD FOUND MARKING THE WEST CORNER OF SAID LOT 12 AND THE NORTH CORNER OF LOT 14, BLOCK 3; S 40° 59' 03" W FOR A DISTANCE OF 369.69 FEET TO A 1/2 INCH IRON ROD FOUND MARKING THE WEST CORNER OF SAID LOT 14 AND THE NORTH CORNER OF LOT 16, BLOCK 3; S 42° 32' 43" W FOR A DISTANCE OF 41.52 FEET TO A 1/2 INCH IRON ROD MARKING THE SOUTH CORNER OF THIS HEREIN DESCRIBED TRACT; THENCE: N 47° 42' 16" W THROUGH SAID REMAINDER OF 28.57 ACRE TRACT FOR A DISTANCE OF 399.48 FEET TO A 1/2 INCH IRON ROD SET ON THE SOUTHEAST LINE OF STATE HIGHWAY NO. 30 MARKING THE WEST CORNER OF THIS HEREIN DESCRIBED TRACT; THENCE: ALONG THE SOUTHEAST LINE OF STATE HIGHWAY 30 FOR THE FOLLOWING CALLS: N 33° 17' 22" E FOR A DISTANCE OF 738.25 FEET TO THE BEGINNING OF A CLOCKWISE CURVE HAVING A RADIUS OF 2757.32 FEET, FOR REFERENCE A 1/2 INCH IRON ROD FOUND BEARS: N 00° 33' 21" E FOR A DISTANCE OF 0.17 FEET, AND A CONCRETE RIGHT-OF-WAY MARKER FOUND ON THE NORTHWEST LINE OF STATE HIGHWAY NO. 30 BEARS: N 56° 42' 38" W FOR A DISTANCE OF 119.98 FEET; ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 09° 00' 34" FOR AN ARC DISTANCE OF 433.58 FEET (CHORD BEARS: N 37° 47' 39" E - 433.13 FEET) TO THE END OF SAID CURVE, FOR REFERENCE A CONCRETE RIGHT-OF-WAY MARKER FOUND BEARS: S 48° 33' 16" W FOR A DISTANCE OF 2.20 FEET; N 42° 17' 56" E FOR A DISTANCE OF 338.40 FEET TO THE NORTH CORNER OF SAID 11.37 ACRE TRACT AND THE WEST CORNER OF BLOCK 4, HARVEY HILLSIDES, ACCORDING TO THE PLAT RECORDED IN VOLUME 264, PAGE 484 OF THE DEED RECORDS OF BRAZOS COUNTY, TEXAS; THENCE:S 49° 15' 45" E ALONG THE COMMON LINE OF SAID 11.37 ACRE TRACT AND SAID BLOCK 4, AND THE AFOREMENTIONED BLOCK 3, HARVEY HILLSIDES, FOR A DISTANCE OF 524.98 FEET TO THE POINT OF BEGINNING CONTAINING 28.294 ACRES OF LAND AS SURVEYED ON THE GROUND MARCH, 2016. BEARING SYSTEM SHOWN HEREIN IS BASED ON THE TEXAS STATE PLANE CENTRAL ZONE GRID NORTH (NAD-83) PER THE PUBLISHED COORDINATES OF THE CITY OF COLLEGE STATION GPS MONUMENT CS94-126 AND AS ESTABLISHED FROM GPS OBSERVATION. DISTANCES SHOWN HEREIN ARE GRID DISTANCES. TO DETERMINE SURFACE (GROUND) DISTANCES MULTIPLY BY A COMBINED SCALED FACTOR OF 1.00010092035446 (CALCULATED USING GEOID12A). SHEET 1 OF 2 July 20, 2017 Regular Agenda Rezoning – Chimney Hill Development To: Planning & Zoning Commission From: Mark Bombek AICP, Senior Planner Agenda Caption: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas, by changing the zoning district boundaries from PDD Planned Development District to PDD Planned Development District for approximately 8 acres in the Chimney Hill Retail Plaza Lots 1-4, Block 1, generally located at 701 & 715 University Drive East. Case #REZ2017-000013 (Final action on this item is scheduled for the August 10, 2017 City Council Meeting- subject to change) Recommendation: Staff recommends approval of the rezoning request with the condition that Sidewalks be added to the Concept Plan along Tarrow Street, as identified on the Bicycle, Pedestrian and Greenways Master Plan. Summary: This PDD Planned Development District request proposes to amend the existing PDD to realign it with the current vision for the development. This property was previously owned by the City of College Station and was sold in 2014 in conjunction with an adopted economic development agreement that provided an additional level of regulation with the PDD. Due to the changed direction for the development, a request has been made to City Council to dissolve this agreement. This will be considered at an upcoming meeting for City Council. REZONING REVIEW CRITERIA 1. Consistency with the Comprehensive Plan: The subject property is designated as General Commercial on the Comprehensive Plan’s Future Land Use and Character Map and is within the area identified as the Hospitality Corridor along University Drive East. The proposed project has sought to redevelop an aging shopping center along one of the College Station’s primary image corridors. The site was originally constructed in the late 1970s and the proposed project will retain mostly commercial retail uses, but is allowed to develop some residential uses that provides a mix of uses in line with an urban development pattern. The subject property is surrounded by thoroughfares and developed property zoned GC General Commercial with OV Corridor Overlay. The proposed development will continue the commercial nature of the immediate vicinity while allowing residential uses in which the parking will be accommodated within a parking garage. Given the amount of access and proximity to major thoroughfares, commercial uses remain suitable for this centrally located property. A greater intensity of uses though, is commonly needed to support the costs associated with a redevelopment project of this nature. While marketable as a commercial-only property, the opportunity provided by redevelopment allows for the creation of a unique, destination-based development along one of the City’s main corridors. 2. Compatibility with the present zoning and conforming uses of nearby property and with the character of the neighborhood: The uses requested for the PDD are those allowed under the current PDD that utilizes a base zoning district of GC General Commercial and R-6 High Density Multi-Family, Given the current development pattern of the area being primarily commercial retail and office uses, the proposed uses of the subject property are compatible. 3. Suitability of the property affected by the amendment for uses permitted by the district that would be made applicable by the proposed amendment: The property is located at the intersection of a 6-lane Major Arterial, University Drive, and 4-lane Minor Arterial, Tarrow Street. This is a suitable location for a large scale commercial development that could serve as an anchor for the University Drive Corridor and hopefully spur the redevelopment of other underutilized properties in an area that is beginning to show a demand for increased urban development. 4. Suitability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The size and location of the property is suitable for intense commercial and residential uses. With its location at the intersection of two thoroughfares, the uses allowed under the General Commercial and R-6 High Density Multi-Family zoning districts are suitable for this property with the modifications listed in the Concept Plan notes. 5. Marketability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The property is currently marketable various commercial and residential uses under the existing PDD Planned Development District. The purpose of the request is to amend the concept plan and existing language to align the ordinance with the current vision for the development. 6. Availability of water, wastewater, stormwater, and transportation facilities generally suitable and adequate for the proposed use: There is a 12-inch water line along East Tarrow, a 20-inch water line along Tarrow Street, and an 8-inch sanitary sewer line off East Tarrow to serve the property. Storm drainage is to Burton Creek and post-development flows will not be able to exceed pre-development flows. Drainage and other public infrastructure required with site development shall be designed and constructed in accordance with the B/CS Unified Design Guidelines. Existing infrastructure appear to have capacity to adequate serve the proposed change of use at this time. Access to the subject tract will be via Tarrow Street/East Tarrow, a four-lane Minor Arterial, and University Drive East, a six-lane Major Arterial. A Traffic Impact Analysis (TIA) was submitted as part of this rezoning application. Based on the analysis, an additional right- turn lane is required on Tarrow Street for the southbound approach to University Drive East as it falls below the acceptable level of service with the forecasted and site-generated traffic. A right-turn deceleration lane will be required for the proposed consolidated driveway from University Drive East due to the anticipated volume of right turns into the site. SUMMARY OF EXISTING PDD AND CONCEPT PLAN (The change with this request is shown in bold) The Concept Plan provides an illustration of the general layout of the proposed building and parking areas as well as other site related features. The request is revising the Concept Plan to eliminate specific building footprints and building locations to allow more flexibility with site development. In proposing a PDD, an applicant may also request variations to the general site development standards provided that those variations are outweighed by demonstrated community benefits of the proposed development. The Unified Development Ordinance provides the following review criteria as the basis for reviewing PDD Concept Plans:  The proposal will constitute an environment of sustained stability and will be in harmony with the character of the surrounding area;  The proposal is in conformity with the policies, goals, and objectives of the Comprehensive Plan, and any subsequently adopted Plans, and will be consistent with the intent and purpose of this Section;  The proposal is compatible with existing or permitted uses on abutting sites and will not adversely affect adjacent development;  Every dwelling unit need not front on a public street but shall have access to a public street directly or via a court, walkway, public area, or area owned by a homeowners association;  The development includes provision of adequate public improvements, including, but not limited to, parks, schools, and other public facilities;  The development will not be detrimental to the public health, safety, welfare, or materially injurious to properties or improvements in the vicinity; and  The development will not adversely affect the safety and convenience of vehicular, bicycle, or pedestrian circulation in the vicinity, including traffic reasonably expected to be generated by the proposed use and other uses reasonably anticipated in the area considering existing zoning and land uses in the area. The applicant has provided the following information related to the purpose and intent of the proposed zoning district: “The purpose and intent of the PDD is to encourage the redevelopment of an existing underperforming retail center along the University Drive Hospitality Corridor. The new development will provide a destination for residents and visitors to shop, dine, live, and recreate in a more urban environment. Introducing high density residential land uses and more urban development standards will incent the major reinvestment of an underutilized property in a prominent area of College Station.” The Concept Plan proposes three main quadrants that will be utilized for building area and other accessory site development features such as parking and drive aisles and areas for landscaping. These quadrants will be further defined with a replat that will subdivide the property creating smaller internal lot boundaries. The two driveways along University Drive East will be consolidated into one with a right- turn deceleration lane provided. The existing driveway location on East Tarrow with left- turn lane will remain and three new driveways are proposed along Tarrow Street. Such drives will align with the existing drives and/or streets located on the opposite side of Tarrow Street (and “Opposite Left Drive”) or will be offset at least one hundred twenty-five feet (125’) from such Opposite Left Drive. The Concept Plan attached is conceptual in nature and, accordingly the number and configuration of the building and parking areas may not be exactly as shown on the Concept Plan. Base Zoning and Meritorious Modifications The development will utilize GC General Commercial and R-6 High Density Multi-Family as the base zoning districts. Permitted Uses GC General Commercial uses along with multi-family land uses as allowed in R-6 High Density Multi-Family Permitted are permitted Note: the previous PDD planned for a pedestrian-oriented outdoor plaza designed for community events that include a pavilion, tower architectural feature, outdoor sales, display and other park-like amenities. This feature is no longer being provided with the revisions made in the new zoning request. Density The maximum residential density is 30 units per acre as per the R-6 High Density Multi- Family zoning district. Setbacks Instead of standard zoning setbacks, the applicant has proposed: Minimum Front Setback (along University Drive East) 20 feet (normally 25 feet) Minimum Side Setback (between buildings) 7.5 feet Minimum Side Street Setback (along East Tarrow) 15 feet Minimum Rear Setback (along Tarrow Street) 10 feet (normally 15 feet) Height Building height will be regulated by GC General Commercial and R-6 High Density Multi- Family base zoning districts. Building heights will range between one and eight stories. Note: the previous PDD proposed a maximum building height of seven stories. Minimum Driveway Throat Length A minimum driveway throat length (also known as throat depth) as defined in UDO Section 12-7.4.C.7.h. of forty (40) feet is required on all entry drives connecting to Tarrow Street and East Tarrow Street, except for the entry drive on Tarrow Street located closest to University Drive which may have a minimum driveway throat length of thirty-five (35) feet provided a second entry drive from Tarrow Street to the Property is constructed. Sidewalks Sidewalks shall only be required in the development along University Drive and along one side of the interior access drive that connects University Drive to the internal traffic circle. Additionally as shown on the Concept Plan, sidewalks are being provided along East Tarrow with this development. The Bicycle Pedestrian and Greenways Master Plan identifies sidewalks along the entire perimeter of the development. The applicant is requesting to not provide sidewalks along Tarrow Street. As stated previously in the recommendation, staff is recommending that sidewalks be built along Tarrow Street in compliance with the Bicycle, Pedestrian, and Greenways Master Plan. A project has been identified to build a sidewalk along the western side of Tarrow Street that will tie into a connection into the City of Bryan. It is planned for this sidewalk to extend down to University Drive with this property acting as the connection point along East Tarrow and Tarrow Street. Providing sidewalks along the perimeter of this development is crucial to the long-term connectivity anticipated in this area. Parking Parking for multi-family residential uses will be as follows per unit: 1 parking space for the first bedroom in the unit and 0.5 parking space for each additional bedroom in the unit. A “unit” is considered to be a multi-family housing unit containing one or more bedrooms, a kitchen and common living areas. Non-residential parking will be 1 parking space per 250 gross square feet with no increase for restaurants and more intense commercial uses as defined by the Unified Development Ordinance. Other Meritorious Modifications Off-Street Parking Standards: Minimum parking lot setback is reduced to 8 feet along Tarrow Street with double landscape islands not being required every seven parking spaces. Right-of-Way Dedication: No additional right-of-way is anticipated for University Drive East, East Tarrow, or Tarrow Street unless needed for the additional turn-lane mitigation. Non-Residential Architecture Standards: Accessory buildings and parking garages are exempt from the requirements except that parking garages may be constructed of a pre-cast concrete product and painted to complement abutting buildings. Signage The sign regulations for the base zoning districts of GC General Commercial and R-6 High Density Multi-Family will be utilized for this development with the following modifications:  Signs may be approved administratively by staff with appeals to staff’s interpretations to be considered by the Design Review Board;  Wayfinding signage (UDO Section 12-7.5.AA Campus Wayfinding Signs) is permitted for this development and may also be located at street intersections including driveways with parking;  In addition to one freestanding sign, low profile signs are allowed at one per building;  Light pole signage may be utilized along the interior access drives and traffic circle only and is limited to a maximum of 14 light pole signs with 36 square feet per light pole. These signs are not in lieu of freestanding signage, and are intended as development identification and special event signage, will not be utilized for tenant signage, and do not count against attached signage. (Note: This signage was originally being utilized as part of the pedestrian plaza that was proposed with the original PDD. This signage is intended to be utilized for the same purposes, but placed along the interior drive aisle instead of the surrounding the plaza.)  Apartment Identification signage is allowed with two detached signs – one placed at University Drive East and East Tarrow and a second placed at University Drive East and Tarrow Street only advertising the subdivision, development, or area. No commercial tenant advertising shall occur on the Apartment Identification signs; and  Attached signage is permitted for all residential and non-residential buildings. o The residential portion of the public entry façade shall be calculated in the allowance for attached signage square footage. o The facades of the commercial-only buildings along University Drive East are to be included in the public entry façade calculation. STAFF RECOMMENDATION Staff recommends approval of the rezoning request with the condition that Sidewalks be added to the Concept Plan along Tarrow Street, as identified on the Bicycle, Pedestrian and Greenways Master Plan. SUPPORTING MATERIALS 1. Background Information 2. Small Area Map and Aerial 3. Application 4. Concept Plan 5. Bulk variance list BACKGROUND INFORMATION NOTIFICATIONS Advertised Commission Hearing Date: July 20, 2017 Advertised Council Hearing Dates: August 10, 2017 The following neighborhood organizations that are registered with the City of College Station’s Neighborhood Services have received a courtesy letter of notification of this public hearing: Chimney Hill HOA Villas of Chimney Hill HOA Property owner notices mailed: 23 Contacts in support: None at the time of staff report. Contacts in opposition: None at the time of staff report. Inquiry contacts: One ADJACENT LAND USES Direction Comprehensive Plan Zoning Land Use North (across Tarrow Street) Suburban Commercial GC General Commercial Office buildings South (across University Dr. E) General Commercial GC General Commercial with OV Corridor Overlay Shopping center and restaurants East (across East Tarrow Street) General Commercial GC General Commercial with OV Corridor Overlay Hotel West (across Tarrow Street) General Commercial GC General Commercial Bank, shopping center including former Albertson’s grocery DEVELOPMENT HISTORY Annexation: 1956 Zoning: GC General Commercial with OV Corridor Overlay PDD Planned Development District 2014 Final Plat: 1975 with replats in 1984 & 1985 Site development: Majority of the site is vacant as a result of the demolition of the previous shopping center. There is one building remaining on the property being The Republic restaurant. This will remain until their new building is constructed on site. Notes: 1. There is no FEMA regulated 100-Year Floodplain on this site per FEMA Map Panel #48041C0215F Dated 04/02/2014. 2. All site lighting will comply with City of College Station ordinances. 3. The development will not include parks, greenways, conservtion areas, schools, or trails. BFV Chimney Hill, LLC Chimney HIll Retail Plaza, Lots 1-4, Block 1 7.95 AC BFV Chimney Hill, LLC C/O Johnathan Hitchcock 24 Waterway Ave., Suite 225 Spring, TX 77380 (978) 376-3981 Mitchell & Morgan, LLP 3204 Earl Rudder Fwy. S. College Station, TX 77845 (979) 260-6963 Oldham Goodwin Group 2800 S. Texas Ave. Bryan, TX 77802 (979) 268-2000 University Dri v e ( R . O . W . V a r i e s ) The purpose and intent of the PDD is to encourage the redevelopment of an existing underperforming retail center along the University Drive Hospitality Corridor. The new development of approximately 8 acres to be subdivided into two or more lots will provide a destination for residents and visitors to shop, dine, live, and recreate in a more modern environment. Introducing high density residential land uses and more modern development standards will incent the major reinvestment of an underutilized property in a prominent area of College Station. The Concept Plan proposes to demolish the existing buildings and construct commercial outparcels, with some uses being up to eight stories, in phases. The two driveways along University Drive East will be consolidated into one driveway with a right-turn deceleration lane provided. The existing driveway location on East Tarrow with left-turn lane will remain. N ew driveways are proposed along Tarrow Street. Such drives will align with the existing drives and/or streets located on the opposite side of Tarrow Street (an “Opposite Left Drive’) or will be offset at least one hundred twenty-five feet (125’) from such Opposite Left Drive. The Concept Plan attached as Exhibit “C” is conceptual in nature and, accordingly, the lot lines, building areas, drives and parking areas of the Development may not be in the exact numbers and locations shown on the Concept Plan. Base Zoning and Meritorious Modifications The development will utilize GC General Commercial and R-6 High Density Multi Family as the base zoning districts. Through the PDD, the following meritorious modifications have been granted: Permitted Uses GC General Commercial uses along with multi-family land uses as allowed in R-6 High Density Multi- Family zoning are permitted. Density The maximum residential density for the development is 30 units per acre to be calculated based on the entire acreage of the Property and the total maximum number of units may be located on any one or more lots within the Property. Setbacks Instead of standard zoning setbacks, the following will apply: Minimum Front Setback (along University Drive East): 20 feet Minimum Side Setback (between buildings): 7.5 feet Minimum Side Street Setback (along East Tarrow Street): 15 feet Minimum Rear Setback (along Tarrow Street): 10 feet Height Building height will be regulated by GC General Commercial and R-6 High Density Multi-Family base zoning districts. Building heights will range between one and eight stories. Minimum Driveway Throat Length A minimum driveway throat length (also known as throat depth) as defined in UDO Section 12-7.4.C.7.h. of forty (40) feet is required on all entry drives connecting to Tarrow Street and East Tarrow Street, except for the entry drive on Tarrow Street located closest to University Drive which shall have a minimum driveway throat length of thirty-five (35) feet provided a second entry drive from Tarrow Street to the Property is constructed. Sidewalks Sidewalks shall only be required in the development along University Drive and along one side of the interior access drive that connects University Drive to the internal traffic circle. Parking Parking for multifamily, residential uses will be as follows per unit: 1 parking space for the first bedroom in the unit and 0.5 parking spaces for each additional bedroom in such unit. A “unit” is considered to be a multifamily housing unit containing one or more bedrooms, a kitchen and common living areas. Non- residential parking will be 1 parking space per 250 gross square feet with no increase for restaurants and other more intense commercial uses as defined by the Unified Development Ordinance. Off-Street Parking Standards: Minimum parking lot set back is reduced to 8 feet along all streets with double landscape islands not being required every 7 parking spaces. Right-of-Way Dedication: No additional right-of-way is anticipated for University Drive East, East Tarrow Street, or Tarrow Street unless needed for the additional turn-lane mitigation. Non-Residential Architecture Standards: Accessory buildings and parking garages are exempt from the requirements except that parking garages must be painted to complement abutting buildings. Signage The sign regulations for the base zoning districts of GC General Commercial and R-6 High Density Multi- Family will be utilized for this development with the following modifications:  Signs may be approved administratively by staff with appeals of staff’s interpretations to be considered by the Design Review Board;  Wayfinding signage (UDO Section 12-7.5.AA Campus Wayfinding Signs) is permitted for this development and may also be located at street intersections and on interior driveways;  In addition to one freestanding sign, low profile signs are allowed at one per building;  In addition to one freestanding sign and the low-profile signs, the following are allowed in the development: o Light pole signage may be utilized along the interior access drives and traffic circle only and is limited to a maxim um of 14 light pole signs with 36 square feet per light pole. These signs are not in lieu of freestanding signage, are intended as development identification and special event signage, will not be utilized for tenant signage, and do not count against attached signage limitations; o Any R-6 based zoning identification signage is allowed with two detached signs one placed at University Drive East and East Tarrow Street and a second placed at University Drive East and Tarrow Street only advertising the subdivision, development, or area. No commercial tenant advertising shall occur on the R-6 based zoning identification signs; and  Attached signage is permitted for all residential and non-residential buildings. o The residential portion of the public entry façade shall be calculated in the allowance for attached signage square footage. o The facades of the commercial-only buildings along University Drive East are to be included in the public entry façade calculation. July 20, 2017 Regular Agenda Rezoning – Conaway Tract To: Planning and Zoning Commission From: Jennifer Prochazka, AICP, Economic Development Manager Agenda Caption: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from R Rural to GC General Commercial on approximately 35.91 acres of land being situated in the J.W. Scott Survey, Abstract No. 49 in College Station, Brazos County, Texas, located at 4000 and 4002 University Drive East, and more generally located south of the intersection of University Drive East and FM158 at the College Station city limit line. Case #REZ2017-000016 (Note: Final action on this item is scheduled for the July 27th City Council meeting – subject to change) Recommendation: Staff recommends approval of the rezoning. Summary: The proposed City-initiated rezoning from R Rural to GC General Commercial is to allow for infill commercial development opportunities in north College Station. The intent of pursuing this entitlement at this time is to preserve potential commercial sites for future development. The property is located at the intersection of two regionally significant roadways, a location appropriate for general commercial development. REZONING REVIEW CRITERIA 1. Consistency with the Comprehensive Plan: The subject area is designated on the Comprehensive Plan Future Land Use and Character Map as General Commercial. The General Commercial designation is described in the Comprehensive Plan as areas intended for concentrations of commercial activities that cater to both nearby residents and to the larger community or region. Generally these areas tend to be large in size, located near the intersection of two regionally significant roads, and concentrated in nodes within the community. The proposed rezoning is in compliance with the Comprehensive Plan. The City adopted the Economic Development Master Plan in 2012, with an over-arching goal of a diversified economy generating quality, stable, full-time jobs; bolstering the sales and property tax base; and contributing to a high quality of life. One of the strategic initiatives for continued economic success is to support retail development by ensuring that there are opportunities to locate and expand businesses that make College Station a regional destination for retail services. The stated Master Plan goal for retail is as follows: “The City of College Station will continue to recognize the significance of retail expenditures to the local economy and will ensure that locations are ready to accommodate the development of such opportunities and that the City remains responsive to an ever-changing market.” 2. Compatibility with the present zoning and conforming uses of nearby property and with the character of the neighborhood: The properties located immediately to the north and west are located in the City of Bryan and are zoned and used as A-O Agricultural-Open and Planned Development (multi-family), respectively. To the east is a lawnmower repair business and a home, both zoned CI Commercial Industrial. To the south is vacant land planned for future phases of Summit Crossing, a townhome and duplex development. 3. Suitability of the property affected by the amendment for uses permitted by the district that would be made applicable by the proposed amendment: The property has approximately 1,200 feet of frontage on Boonville Road (FM 158), and approximately 900 feet of frontage on University Drive East. The intersection of these regionally significant roadways is suitable for General Commercial uses such as retail and restaurant. 4. Suitability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The property is currently zoned R Rural and is used for single-family and for agricultural uses. The property is suitable for rural uses. 5. Marketability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The subject property may be marketable with its current zoning of R Rural, however, the requested rezoning provides an opportunity for regionally significant commercial development and the intersection of two regionally significant roadways, where general commercial land uses are most appropriate. 6. Availability of water, wastewater, stormwater, and transportation facilities generally suitable and adequate for the proposed use: Water and sewer service is not currently available to this property. Off-site sewer extensions from the southeast will be required for service to this tract. The City’s Water Master Plan requires 18-inch and 12-inch lines be extended with development of this property, and a future 12-inch waterline will need to be extended with the future extension of Summit Crossing Lane. Detention will be required with development of this property. Drainage and other public infrastructure required with site development shall be designed and constructed in accordance with the BCS Unified Design Guidelines. Future master planned infrastructure, appear to be adequate for the proposed general commercial use at this time. The subject property has approximately 1,200 feet of frontage on Boonville Road (FM 158), designated a 6-lane Major Arterial and approximately 900 feet of frontage on University Drive East, designated a 4-lane Major Arterial on the City’s Thoroughfare Plan. Summit Crossing Lane, a future 2-lane Minor Collector, is proposed to be located near the southwest property edge. Access to the site will likely be from University Drive, Boonville Road and Summit Crossing Lane. A Traffic Impact Analysis (TIA) is not required with the proposed rezoning as the adjacent thoroughfares have been widened with medians and traffic signal installed at the intersection of University Drive East and Boonville Road (FM 158). A TIA will be required with the platting of the tracts which is closer to the time of development and will identify traffic impact and site access needs at that time. Budget & Financial Summary: N/A Attachments: 1. Background Information 2. Aerial & Small Area Map 3. Rezoning Map Background NOTIFICATIONS Advertised Commission Hearing Date: July 20, 2017 Advertised Council Hearing Date: July 27, 2017 The following neighborhood organizations that are registered with the City of College Station’s Neighborhood Services have received a courtesy letter of notification of this public hearing: N/A Property owner notices mailed: 9 Contacts in support: None at the time of staff report. Contacts in opposition: None at the time of staff report. Inquiry contacts: None at the time of staff report. ADJACENT LAND USES Direction Comprehensive Plan Zoning Land Use North (Across FM 158 in Bryan) N/A City of Bryan - C-2 Retail District and A-O Agricultural-Open District Vacant and single- family homes South Urban GC General Commercial and R Rural Vacant East Urban and General Commercial PDD Planned Development District for Multi-family housing and CI Commercial Industrial Vacant and lawn mower repair West (Across University Drive East in Bryan) N/A City of Bryan-PD for Multi-family housing Multi-family DEVELOPMENT HISTORY Annexation: 1980 Zoning: 1980 - Zoned A-O Agricultural-Open at the time of annexation. 2013 – A-O renamed R Rural Final Plat: Unplatted Site development: Undeveloped Existing: R Rural Proposed: GC General Commercial ALLEYM O M E N T U M BL DANSBYLNM A R C Y L NEASTCHESTERDREA S T C R E S T D R C O R P O R A T E C E N T E R D R SARA LNHICKSLNCROSSPARKDREASTCHESTER DRCROSSPARKDRHICKS LNUNIVERSITY DR EHARVEYRDSARALNBOONVILLE RD MOM E N T UMBLDANSBYLNFM 158 July 20, 2017 Regular Agenda Rezoning – 108, 110, 200 & 206 George Bush Drive East To: Planning and Zoning Commission From: Jennifer Prochazka, AICP, Economic Development Manager Agenda Caption: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing t he zoning district boundaries from GS General Suburban to GC General Commercial for approximately one acre of land being College Hills Estates Block 18, Lots 6, 7, 8, 9 and 11, more generally located at 108, 110, 200 & 206 George Bush Drive East. Case #REZ2017-000017 (Note: Final action on this item is scheduled for the July 27th City Council meeting – subject to change) Recommendation: Staff recommends approval of the rezoning. Summary: The proposed City-initiated rezoning from GS General Suburban to GC General Commercial is to allow for infill commercial redevelopment opportunities in proximity to Texas A&M University. The subject properties are located along the south side of George Bush Drive East, just north of existing commercial development. The lots are currently developed as single- family residential homes. While the properties are likely too small to redevelop for commercial uses on their own, there is opportunity for consolidation of lots for a larger redevelopment effort. As currently zoned, the properties could redevelop as single-family homes on a lot-by-lot basis, potentially precluding future commercial redevelopment in the area. This area was identified by Staff as a prime location for needed general commercial redevelopment and as a targeted area for commercial preservation. 100, 102, 104, 106, 112, and 204 George Bush Drive East were recently rezoned to GC General Commercial at the request of the property owners. Since that time, staff hosted a property owner meeting to discuss the potential of City-initiated rezoning on the remainder of the block. Two property owners in attendance preferred to retain the single-family zoning designation on the property until the time that they sold their properties. Those properties are located at the north end of the block and have not been included in this rezoning request. REZONING REVIEW CRITERIA 1. Consistency with the Comprehensive Plan: The subject area is currently designated on the Comprehensive Plan Future Land Use and Character Map as Urban and Redevelopment. This area is included in Redevelopment Area II in the Comprehensive Plan, stating the following: includes a number of underperforming land uses that, due to their proximity to two of the busiest corridors in the City, are poised for redevelopment. Much of the area is currently subdivided into small lots, making it difficult to assemble land for redevelopment. A portion of this area includes the current City Hall, which offers the opportunity to redevelop a larger parcel if City Hall is relocated to the Municipal Center District. The proximity of existing neighborhoods and the Texas A&M University campus requires careful site planning and appropriate building design. These efforts should be complimentary to the Area V: Hospitality corridor plan, the neighborhood plan for the Eastgate area, and the Texas A&M University Campus Master Plan and should focus on bringing vertical mixed-use and other aspects of urban character to this portion of the City. The Eastgate Neighborhood Plan includes discussion of this area and specifically states the following: The block bounded by George Bush Drive East, Texas Avenue South and Dominik Drive is split with two character designations. The lots on the north side of the block that front George Bush Drive East are designated as Urban and Redevelopment in the Comprehensive Plan and are developed as single-family residential. The lots on the block face fronting Dominik Drive are designated as Urban Mixed Use and Redevelopment and are developed with commercial uses. With aging commercial properties and single-family rental dwellings, the area is poised for redevelopment and consolidation of property on both sides of the block. In addition, given the block’s location in the City and proximity to major thoroughfares, Texas Avenue South (six-lane major arterial) and George Bush Drive East (four-lane major collector), more intense development is anticipated. To create more consistency in the future development pattern, both block faces should be designated Urban with an emphasis on creating mixed-use opportunities. Additionally, the City adopted the Economic Development Master Plan in 2012, with an over-arching goal of a diversified economy generating quality, stable, full-time jobs; bolstering the sales and property tax base; and contributing to a high quality of life. One of the strategic initiatives for continued economic success is to support retail development by ensuring that there are opportunities to locate and expand businesses that make College Station a regional destination for retail services. The stated Master Plan goal for retail is as follows: “The City of College Station will continue to recognize the significance of retail expenditures to the local economy and will ensure that locations are ready to accommodate the development of such opportunities and that the City remains responsive to an ever-changing market.” The proposed rezoning is in compliance with the Comprehensive Plan and related master plans. 2. Compatibility with the present zoning and conforming uses of nearby property and with the character of the neighborhood: Discrepancies currently exist in zoning and future land use and character in the area that could lead to unintended development scenarios that are contrary to the character desired by area residents. Lots along the south side of George Bush Drive East are currently zoned GS General Suburban and developed as single-family homes. Properties to the south are zoned GC General Commercial and are developed as such. As the block is rezoned, consolidated, and redeveloped, the proposed GC General Commercial zoning will be consistent and compatible. The subject area is located at the periphery of the Eastgate neighborhood in a redevelopment area. 3. Suitability of the property affected by the amendment for uses permitted by the district that would be made applicable by the proposed amendment: The block is surrounded by major thoroughfares. The proposed rezoning is for seven lots along the south side of George Bush Drive East. The south side of the block (facing Dominik Drive) is already zoned GC General Commercial. As properties continue to rezone for redevelopment in this area and properties consolidate, the area becomes most suitable for General Commercial uses such as retail and restaurant. 4. Suitability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The subject properties along George Bush Drive East are currently zoned GS General Suburban. The property is suitable for single-family residential uses, as they are currently developed as such. The lots currently abut commercially zoned and developed properties and are generally separated from the larger Eastgate neighborhood by George Bush East Drive. 5. Marketability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The subject properties are marketable with their current zoning of GS General Suburban; however, the requested rezoning provides an opportunity for additional commercial redevelopment near Texas A&M University. The existing zoning allows for the existing single-family homes to be redeveloped for new single-family housing on a lot-by-lot basis, potentially precluding redevelopment envisioned by the Comprehensive Plan. 6. Availability of water, wastewater, stormwater, and transportation facilities generally suitable and adequate for the proposed use: Water service is available to the properties from existing 8-inch waterline along the south side of George Bush Drive East. A 6-inch sewer main is located at the rear of the lots closest to Texas Avenue and an 8-inch sewer main is located in front of the properties that are located further from Texas Avenue. Drainage is mainly to the southwest toward Texas Avenue. Drainage and other public infrastructure required with site development shall be designed and constructed in accordance with the BCS Unified Design Guidelines. Existing and proposed infrastructure appear to be adequate for the proposed general commercial use at this time. The subject properties have individual residential driveways along George Bush Drive East, designated a Major Collector on the City’s Thoroughfare Plan. As properties consolidate and redevelop, driveway access points will be consolidated and reduced. Budget & Financial Summary: N/A Attachments: 1. Background Information 2. Aerial & Small Area Map 3. Rezoning Map Background NOTIFICATIONS Advertised Commission Hearing Date: July 20, 2017 Advertised Council Hearing Date: July 27, 2017 The following neighborhood organizations that are registered with the City of College Station’s Neighborhood Services have received a courtesy letter of notification of this public hearing: College Hills Estates Property owner notices mailed: 24 Contacts in support: None at the time of staff report. Contacts in opposition: None at the time of staff report. Inquiry contacts: One (1) at the time of staff report. ADJACENT LAND USES Direction Comprehensive Plan Zoning Land Use North (Across George Bush Drive East) Natural Areas, Urban & Redevelopment GS General Suburban City-owned, undeveloped South Urban & Redevelopment GC General Commercial Retail and Restaurant East (Across Texas Avenue) Urban & Redevelopment GS General Suburban Retail and Restaurant West General Commercial & Redevelopment GC General Commercial Single-Family Residential DEVELOPMENT HISTORY Annexation: 1939 Zoning: 1939 - Zoned for single-family use upon annexation. 2013 – R-1 Single-Family Residential renamed GS General Suburban Final Plat: 1940- College Hills Estates, Fourth Installment Site development: Existing single-family homes Existing: GS General Suburban Proposed: GC General Commercial F O S T E R A V MOSS STGEORGE BUSH DRTE X A S A V DOMINIK DRGEORGE BUSH DRGEORGE BUSH DR EFO S T E R A V T E X A S A V SMOSS ST July 20, 2017 Regular Agenda Rezoning – 1501 Earl Rudder Freeway South To: Planning and Zoning Commission From: Jennifer Prochazka, AICP, Economic Development Manager Agenda Caption: Public hearing, presentation, possible action, and discussion regarding an ordinance amending Chapter 12, “Unified Development Ordinance,” Section 12-4.2, “Official Zoning Map,” of the Code of Ordinances of the City of College Station, Texas by changing the zoning district boundaries from CI Commercial Industrial to GC General Commercial on approximately 8.158 acres of land located at 1501 Earl Rudder Freeway South, and more generally located on the east side of Earl Rudder Freeway, north of Harvey Road. Case #REZ2017-000018 (Note: Final action on this item is scheduled for the July 27th City Council meeting – subject to change) Recommendation: Staff recommends approval of the rezoning. Summary: The proposed City-initiated rezoning from CI Commercial Industrial to GC General Commercial is to allow for infill commercial redevelopment opportunities along Earl Rudder Freeway. The intent of pursuing rezoning at this time is to fully entitle the property for general commercial uses encouraging redevelopment of the site. The property is located on the east side of Earl Rudder Freeway, a location appropriate for general commercial development. REZONING REVIEW CRITERIA 1. Consistency with the Comprehensive Plan: The subject area is designated on the Comprehensive Plan Future Land Use and Character Map as General Commercial. The General Commercial designation is described in the Comprehensive Plan as areas intended for concentrations of commercial activities that cater to both nearby residents and to the larger community or region. Generally these areas tend to be large in size, located near the intersection of two regionally significant roads, and concentrated in nodes within the community. The proposed rezoning is in compliance with the Comprehensive Plan. The City adopted the Economic Development Master Plan in 2012, with an over-arching goal of a diversified economy generating quality, stable, full-time jobs; bolstering the sales and property tax base; and contributing to a high quality of life. One of the strategic initiatives for continued economic success is to support retail development by ensuring that there are opportunities to locate and expand businesses that make College Station a regional destination for retail services. The stated Master Plan goal for retail is as follows: “The City of College Station will continue to recognize the significance of retail expenditures to the local economy and will ensure that locations are ready to accommodate the development of such opportunities and that the City remains responsive to an ever-changing market.” 2. Compatibility with the present zoning and conforming uses of nearby property and with the character of the neighborhood: The surrounding properties are zoned GC General Commercial and developed as such. 3. Suitability of the property affected by the amendment for uses permitted by the district that would be made applicable by the proposed amendment: The property has approximately 300 feet of frontage on Earl Rudder Freeway South Frontage Road. Earl Rudder Freeway South is College Station’s most regionally significant road and properties in this area are generally suitable for General Commercial uses such as retail and restaurant. 4. Suitability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: Because of its size, location, and access to Earl Rudder Freeway Frontage Road, the property is suitable for GC uses. 5. Marketability of the property affected by the amendment for uses permitted by the district applicable to the property at the time of the proposed amendment: The property is currently zoned CI Commercial Industrial and is currently used as self- storage, a permitted use in both CI and GC. When the property was zoned CI and developed, College Station’s zoning was cumulative within the non-residential districts, allowing both CI and GC uses in the CI district. The property is suitable for CI uses, but because of its location, is more appropriate for GC uses. Availability of water, wastewater, stormwater, and transportation facilities generally suitable and adequate for the proposed use: An 18-inch water line exists along Earl Rudder Freeway and an 8-inch exists within the site. An 8-inch sewer line exists through the property. Existing infrastructure appears to be adequate for the proposed general commercial use at this time, however, water and sewer may need to be upgraded depending on demands of future redevelopment on the site. Drainage and other public infrastructure required with site redevelopment shall be designed and constructed in accordance with the BCS Unified Design Guidelines. The subject property has approximately 300 feet of frontage on Earl Rudder Freeway South, a Freeway/Expressway on the City’s Thoroughfare Plan. A Traffic Impact Analysis (TIA) is not required for the rezoning of this property from CI Commercial Industrial to GC General Commercial. A TIA may be required at the time of site redevelopment depending upon the intensity of the proposed redeveloped use. Budget & Financial Summary: N/A Attachments: 1. Background Information 2. Aerial & Small Area Map 3. Rezoning Map Background NOTIFICATIONS Advertised Commission Hearing Date: July 20, 2017 Advertised Council Hearing Date: July 27, 2017 The following neighborhood organizations that are registered with the City of College Station’s Neighborhood Services have received a courtesy letter of notification of this public hearing: N/A Property owner notices mailed: 6 Contacts in support: None at the time of staff report. Contacts in opposition: None at the time of staff report. Inquiry contacts: None at the time of staff report. ADJACENT LAND USES Direction Comprehensive Plan Zoning Land Use North General Commercial, Urban and Natural Areas GC General Commercial Undeveloped South (Across SH6) Urban Mixed-Use GC General Commercial Post Oak Mall and Plantation Oaks Apartments East General Commercial GC General Commercial Hotel, fueling station West General Commercial GC General Commercial Sam’s Club DEVELOPMENT HISTORY Annexation: 1958 Zoning: 1980 - Zoned A-O Agricultural-Open at the time of annexation. 1983 – Rezoned to CI Commercial Industrial Final Plat: 1984 - Harvey Road East 1989 – Harvey Road East Amending Plat 1996 - Harvey Road East Replat Site development: Primary structure built in 1983. Currently used as Lock ‘n’ Roll, a self- storage company. Existing: CI Commercial Industrial Proposed: GC General Commercial A S S O CIA T E S A V TA R A C T WOOD CLIFF CTSPICEWOODCT UNIVERSITY OAKSBLCLEARWOOD CTSANDELWOOD CTWI N D W O O D D R E A R L R U DD E R FW S UNIVERSITYOAKSBLHARVEYRDWINGATE CRMAGNOLIADRWOOD CLIFF CTDOMINIK DRSPICEWOODCTCLEARWOOD CTW I N D W O O D D RSANDELWOOD CTOFFRAMPEARLRUDDERFWSON R A MP E A R L R U D D E R F WS A S S O CIA T E S A V July 6, 2017 Regular Agenda Comprehensive Plan Amendment – Young Tract & Clarke Tract To: Planning and Zoning Commission From: Jennifer Prochazka, AICP, Economic Development Manager Agenda Caption: Public hearing, presentation, possible action, and discussion regarding an ordinance amending the Comprehensive Plan - Future Land Use & Character Map from General Suburban and Business Park to General Commercial for approximately 100 acres located along the east side of State Highway 6, south of The Business Park at College Station and north of the Texas World Speedway property. Case #CPA2017-000008 and Case #CPA2017-000009 (Note: Final action of this item will be considered at the July 27th City Council Meeting- Subject to change.) Recommendation: Staff recommends approval of the amendment to the Comprehensive Plan Future Land Use and Character Map. Summary: The proposed City-initiated Comprehensive Plan Future Land Use and Character Map amendment from General Suburban to General Commercial is for approximately 100 acres located along the east side of State Highway 6 South. As growth and development moves further south, single-family homes are not appropriate adjacent to a freeway. The Natural Areas in the area of the floodplain will remain designated as it is today. REVIEW CRITERIA 1. Changed or changing conditions in the subject area or the City: The City of College Station’s Comprehensive Plan was adopted in 2009. This site was designated as General Suburban on the Future Land Use and Character Map. A portion of the area is identified on the Comprehensive Plan Concept Map as a part of “Growth Area I.” According to the Comprehensive Plan, “Growth areas exhibit opportunities for new development. In general, these areas are greenfields, located beyond the influence area of existing neighborhoods and not intended to be within a district or corridor. These areas will be the most market responsive areas; that is, they will offer the greatest level of land use flexibility. This flexibility will be accompanied by proscriptive land use and design guidance that will ensure the resulting development furthers the City’s overall goals and objectives.” The Comprehensive Plan states that this area “consists of land adjacent to State Highway 6 bounded by the Speedway District to the south, the Pebble Creek area to the north and the Lick Creek Corridor to the east. This area should exhibit a suburban character overall. The streams, related riparian areas and floodplains shall be left intact and undisturbed except where utility placements, recreation facilities, or street crossings are necessary.” City Staff has recently begun to identify and actively market developable commercial properties along key corridors in an effort to attract businesses to the community. Limited developable commercial properties of significant scale exist along Earl Rudder Freeway, the City’s primary commercial corridor. The subject property is one of the areas that City staff identified as an opportunity for future commercial development along the Freeway. 2. Scope of the request: Staff proposes to amend the Comprehensive Plan Future Land Use and Character Map for an area that is approximately 100 acres from General Suburban to General Commercial. The Natural Areas designation shown in the middle of the property will remain. The intent of the amendment is to permit and encourage future general commercial development along State Highway 6 South. 3. Availability of adequate information: The General Commercial designation allows for future development of general commercial uses such as retail and restaurant uses. The property has over 5,500 feet of frontage along Earl Rudder Freeway. 4. Consistency with the goals and strategies set forth in the Plan: The proposal is consistent with the goals and strategies of the Comprehensive Plan. The goal for College Station’s Future Land Use and Character is to create a community with strong, unique neighborhoods, protected rural areas, special districts, distinct corridors, and a protected and enhanced natural environment. City staff has identified the undeveloped frontage as a future commercial development opportunity along Earl Rudder Freeway, the City’s primary commercial corridor. The portion of the property proposed for General Commercial use is located furthest from the existing residential uses. The City adopted the Economic Development Master Plan in 2012, with an over-arching goal of a diversified economy generating quality, stable, full-time jobs; bolstering the sales and property tax base; and contributing to a high quality of life. One of the strategic initiatives for continued economic success is to support retail development by ensuring that there are opportunities to locate and expand businesses that make College Station a regional destination for retail services. The stated Master Plan goal for retail is as follows: “The City of College Station will continue to recognize the significance of retail expenditures to the local economy and will ensure that locations are ready to accommodate the development of such opportunities and that the City remains responsive to an ever-changing market.” 5. Consideration of the Future Land Use & Character and/or Thoroughfare Plans: The subject property is currently designated as General Suburban on the Comprehensive Plan Future Land Use and Character Map. The proposed amendment is to General Commercial. The current land use of General Suburban is intended for high density single-family use. The proposed land use of General Commercial is intended for concentrations of commercial activities that cater both to nearby residents and to the larger community or region. Generally, these areas tend to be large in size and located near the intersection of two regionally significant roads (arterials and freeways). Earl Rudder Freeway South is designated as a Highway/Freeway on the City’s Thoroughfare Plan. Given its location, the subject property is suitable for a General Commercial land use designation. A portion of the area is identified on the Comprehensive Plan Concept Map as a part of “Growth Area I.” Growth areas exhibit opportunities for new development. In general, these areas are greenfields, located beyond the influence area of existing neighborhoods and not intended to be within a district or corridor. These areas will be the most market responsive areas; that is, they will offer the greatest level of land use flexibility. This flexibility will be accompanied by proscriptive land use and design guidance that will ensure the resulting development furthers the City’s overall goals and objectives. 6. Compatibility with the surrounding area: The proposed amendment to General Commercial would allow for the property to be zoned in the future for commercial uses that serve the general community and region. The surrounding area is largely undeveloped. 7. Impacts on infrastructure including water, wastewater, drainage, and the transportation network: Water service is available to this area from existing 8-inch and 18-inch waterlines along State Highway 6 South and Lakeway Drive, respectively. There is an existing 15-inch sewer main through the area that may serve this property. Drainage and other public infrastructure required with site development shall be designed and constructed in accordance with the BCS Unified Design Guidelines. Existing infrastructure appears to be adequate for the proposed future general commercial use at this time. The subject property has frontage on Earl Rudder Freeway South, a Freeway/Expressway and the extension of Lakeway Drive, a two-lane Major Collector on the City’s Thoroughfare Plan. An unnamed Minor Arterial is projected to cross this area at the overpass at State Highway 6 South and an additional unnamed minor collector is shown on the City’s Thoroughfare Plan. Access to the area will be from Earl Rudder Freeway South, Lakeway Drive, and future thoroughfares. 8. Impact on the City’s ability to provide, fund, and maintain services: The proposed amendment for the subject property does not negatively impact the City’s ability to provide, fund, and maintain services. 9. Impact on environmentally sensitive and natural areas: The proposed amendment for the area does not negatively impact natural areas nor prevent the preservation of such areas. 10. Contribution to the overall direction and character of the community as captured in the Plan’s vision and goals: The goal for College Station’s Future Land Use and Character is to create a community with strong, unique neighborhoods, protected rural areas, special districts, distinct corridors, and a protected and enhanced natural environment. The proposed amendment to General Commercial does not limit the goals of the Comprehensive Plan. The amendment proposes future uses consistent with properties fronting a regionally significant freeway. Supporting Materials 1. Background Information 2. Aerial 3. Land Use Comparison Background NOTIFICATIONS Advertised Commission Hearing Date: July 20, 2017 Advertised Council Hearing Date: July 27, 2017 Contacts in support: None at the time of staff report. Contacts in opposition: None at the time of staff report. Inquiry contacts: None at the time of staff report. ADJACENT LAND USES Direction Comprehensive Plan Zoning Land Use North Business Park M-1 Planned Industrial College Station Business Center South General Suburban R Rural Texas World Speedway, auto sales, distribution East General Suburban R Rural Undeveloped West (Across Earl Rudder Freeway) Restricted Suburban and Rural GS General Suburban, R Rural, PDD Planned Development District for housing Single-family housing DEVELOPMENT HISTORY Annexation: 1994 & 1996 Zoning: 1994 & 1996 – A-O Agricultural-Open upon annexation 2007 – Approximately 16 acres rezoned to CI Commercial Industrial 2013 – A-O renamed R Rural Final Plat: The majority of the properties are currently unplatted, with the exception of Animate Habitat Phase 1, platted in 2007 for the development of A&M Super Storage. Site development: The majority of the subject properties, as well as the surrounding area, are currently undeveloped, with the exception of A&M Super Storage on approximately five acres. View.ashx %d×%d pixels https://collegestation.legistar.com/View.ashx?M=F&ID=5311107&GUID=63DF73DB-B7E9-4041-AB3C-82B84564AEA2[7/13/2017 4:27:24 PM]