CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS
Case Number
T.A.B. Construction
Name of Applicant
P.O. Box 823
Mailing Address Georgetown, TX- 78627
(512 ) 310-0094
Telephone Number
Name of Property Owner
Simon Kahan----
219 Manuel
Mailing Address TX 77840
College Station,
Telephone Number
(409 ) 693-0051
LOCATION OF PROPERTY
219 Manuel Drive
Address
---
Lott KFO Addition
5 Block 1 Subdivision
� --
Description if Applicable _
Want to variance to Table 700
Action Requested
Current Zoning of Subject Land
Table 700
Applicable Ordinance Section
—.. 4 TuE 1 4 = 4c3
=SEC 1 ?a
COMPLETE THE FOLLOWING FOR A VARIANCE REQUEST
The following specific variation from the ordinance is requested.
To change the fire walls into 4 sections to meet fire ordinances and
to eliminate the requirement for fire rated exit access corridors .
This variance is necessary due to the following special conditions.
I would have to redesign the entire building unaer the current
ordinance.
•
The following alternatives to the requested variance are possible.
To run fire walls from front to back of building and into 4 sections.
This variance will not be contrary to the public interest by
virtue of the following
We will be achieving the same fire protection by running
facts:
the fire walls in all 4 sections.
The facts stated by me in this application are true and correct to the best of my knowledge.
la ! 3- 5V
Date
Applicant •
CONSTRUCTION BOARD OF ADJUSTMENTS
AND APPEALSBUILDING AND
STANDARDS COMMISSION
FORMAT FOR NEGATIVE MOTION FOR A VARIANCE
I move to deny a variance from the terms of this ordinance for the following reasons: A
variance would be contrary to the public interest; no special conditions exist by which a
strict enforcement of the provisions of the ordinance would result in unnecessary
hardship to this applicant; in addition, granting a variance would not observe nor
accomplish substantial justice.
74 6'4,A) 5 rn c)c f, C:,/ 4.1 7 19 5 )9v
74
1 nJ 1r ".J! ,- -r 7-4 C' c 0 GIC C D Al c P I`' i✓ ,vR_C
SCO/-V_'s,9 ? �✓ /0 A..)/-1 C--%x ; ( e CO g i dc i_ S,
1-- 9 ---_____,_,7
Motion made by , / c6'") a G7//' Date /-3-
Seconded by �a ,n c✓ z 5 .- Voting Results
Chair Signature Mftl<----
In , , • `
CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS
STAFF REPORT
•
Case Number: 95-001
Applicant: T.A.B. Construction
Post Office Box 823
Georgetown,Texas 78627
Telephone: 512/310-0094
Property Owner: Simon Kahan
219 Manuel
College Station,Texas 77840
Telephone: 409/693-0051
Location of Property: 219 Manuel Drive
Description of Property: Lot 5, Block 1,of KFO Addition
Zoning of Property: Table 700
Action Requested: To allow installation of fire rated walls from the front to the back of the
structure. This would create four sections in the building. Also,consideration of variance to the
requirement for fire rated exit access corridors.
Building Official's Comments: City Ordinance 1919 and Standard Building Code 1991 addition,
Section 1103.4.7 Table 700 require 1 hour rated walls for corridor access and 1 hour rated doors for
partitions between rooms and corridors or hallways.
•
1:01 CITY OF COLLEGE STATION
Post Office Box 9960 1101 Texas Avenue
College Station,Texas 77842-9960
(409)764-3500
December 27, 1994
The Eagle 4--+4 _ r V
Attn: Joyce Hayes -"'
1729 Briarcrest Drive
Bryan,Texas 77802
Re: Legal Publication
Dear Brenda:
Please publish the following legal notice in the classified section on Thursday,December 29, 1994. Please
bill the City of College Station,Post Office Box 9960, College Station,Texas 77840.
The College Station Construction Board of Adjustments and appeals will hold a
public hearing to consider a variance request by T.A.B. Construction regarding
the following property: 219 Manuel,Lot 5,Block 1 of the KFO Addition,
Current Zoning of Table 700.
The hearing will be held in the Council Room of the College Station City Hall,
1101 Texas Avenue at 4:00 p.m.on January 3, 1995. Any request for sign
interpretive services,must be made 48 hours before the meeting. To make
arrangements call(409)764-3547 or(TDD) 1-800-735-2989.
For additional information please contact the undersigned at(409)764-3743.
Barbara P.DeWeese,Building Technician.
If you have any questions please call me at(409)764-3743. Thank you in advance for assistance in this
matter.
Best regards,
` A _ S
arbara P.DeWeese,
Building Technician
Home of Texas ABM University