Loading...
HomeMy WebLinkAbout2016-3776 - Ordinance - 06/09/2016ORDINANCE NO. 2016-3776 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF COLLEGE STATION, TEXAS, APPROVING A NEGOTIATED SETTLEMENT BETWEEN THE ATMOS CITIES STEERING COMMITTEE ("ACSC") AND ATMOS ENERGY CORP., MID­ TEX DIVISION REGARDING THE COMPANY'S 2016 RA TE REVIEW MECHANISM FILINGS; DECLARING EXISTING RA TES TO BE UNREASONABLE; ADOPTING TARIFFS THAT REFLECT RA TE ADJUSTMENTS CONSISTENT WITH THE NEGOTIATED SETTLEMENT; FINDING THE RATES TO BE SET BY THE SETTLEMENT TARIFFS TO BE JUST AND REASONABLE AND IN THE PUBLIC INTEREST; REQUIRING THE COMPANY TO REIMBURSE ACSC'S REASONABLE RA TEMAKING EXPENSES; DETERMINING THAT THIS ORDINANCE WAS PASSED IN ACCORDANCE WITH THE REQUIREMENTS OF THE TEXAS OPEN MEETINGS ACT; ADOPTING A SAVINGS CLAUSE; DECLARING AN EFFECTIVE DATE; AND REQUIRING DELIVERY OF THIS ORDINANCE TO THE COMPANY AND THE ACSC'S LEGAL COUNSEL. WHEREAS, the City of College Station, Texas ("City") is a gas utility customer of Atmos Energy Corp., Mid-Tex Division ("Atmos Mid-Tex" or "Company"), and a regulatory authority with an interest in the rates and charges of Atmos Mid-Tex; and WHEREAS, the City is a member of the Atmos Cities Steering Committee ("ACSC"), a coalition of similarly-situated cities served by Atmos Mid-Tex ("ACSC Cities") that have joined together to facilitate the review of, and response to, natural gas issues affecting rates charged in the Atmos Mid-Tex service area; and WHEREAS, ACSC and the Company worked collaboratively to develop a new Rate Review Mechanism ("RRM") tariff that allows for an expedited rate review process by ACSC Cities as a substitute to the Gas Reliability Infrastructure Program ("GRIP") process instituted by the Legislature, and that will establish rates for the ACSC Cities based on the system-wide cost of serving the Atmos Mid-Tex Division; and WHEREAS, on March 1, 2016, Atmos Mid-Tex filed its 2016 RRM rate request with ACSC Cities; and WHEREAS, ACSC coordinated its review of the Atmos Mid-Tex 2016 RRM filing through its Executive Committee, assisted by ACSC's attorneys and consultants, to resolve issues identified in the Company's RRM filing; and WHEREAS, the Executive Committee, as well as ACSC's counsel and consultants, recommend that ACSC Cities approve an increase in base rates for Atmos Mid-Tex of $29.9 million on a system-wide basis; and WHEREAS, the attached tariffs implementing new rates are consistent with the recommendation of the ACSC Executive Committee, are agreed to by the Company, and are just, reasonable, and in the public interest; and 1 Ordinance No. 2016-3776 Page 2of14 WHEREAS, the RRM Tariff contemplates reimbursement of ACSC's reasonable expenses associated with RRM applications; NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF COLLEGE STATION, TEXAS: Part 1: That the findings set forth in this Ordinance are hereby in all things approved. Part 2: That the City Council finds that the settled amount of an increase in revenues of $29.9 million on a system-wide basis represents a comprehensive settlement of gas utility rate issues affecting the rates, operations, and services offered by Atmos Mid-Tex within the municipal limits arising from Atmos Mid-Tex's 2016 RRM filing is in the public interest, and is consistent with the City's authority under Section 103.001 of the Texas Utilities Code. Part 3: That the existing rates for natural gas service provided by Atmos Mid-Tex are unreasonable. The new tariffs attached hereto and incorporated herein as Attachment A, are just and reasonable, and are designed to allow Atmos Mid-Tex to recover annually an additional $29.9 million in revenue over the amount allowed under currently approved rates, as shown in the Proof of Revenues attached hereto and incorporated herein as Attachment B; such tariffs are hereby adopted. Part 4: That the ratemaking treatment for pensions and other post-employment benefits in Atmos Mid-Tex's next RRM filing shall be as set forth on Attachment C, attached hereto and incorporated herein. Part 5: That Atmos Mid-Tex shall reimburse the reasonable ratemaking expenses of the ACSC in processing the Company's 2016 RRM filing. Part 6: That to the extent any resolution or ordinance previously adopted by the Council is inconsistent with this Ordinance, it is hereby repealed. Part 7: That the meeting at which this Ordinance was approved was in all things conducted in strict compliance with the Texas Open Meetings Act, Texas Government Code, Chapter 5 51. Part 8: That if any one or more sections or clauses of this Ordinance is adjudged to be unconstitutional or invalid, such judgment shall not affect, impair, or invalidate the remaining provisions of this Ordinance, and the remaining provisions of the Ordinance shall be interpreted as if the offending section or clause never existed. Part 9: That consistent with the City Ordinance that established the RRM process, this Ordinance shall become effective from and after its passage with rates authorized by attached tariffs to be effective for bills rendered on or after June 1, 2016. 2 Ordinance No. 2016-3776 Page 3of14 Part 10: That a copy of this Ordinance shall be sent to Atmos Mid-Tex, care of Chris Felan, Vice President of Rates and Regulatory Affairs Mid-Tex Division, Atmos Energy Corporation, 5420 LJB Freeway, Suite 1862, Dallas, Texas 75240, and to Geoffrey Gay, General Counsel to ACSC, at Lloyd Gosselink Rochelle & Townsend, P.C., 816 Congress A venue, Suite 1900, Austin, Texas 78701. PASSED AND APPROVED this 9111 day of June, 2016. ATTEST: APPROVED AS TO FORM: j1, � City Secr� City Attorney 2557/26/7087606 3 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: R -RESIDENTIAL SALES Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 06/01/2016 1 PAGE: 12 Application Applicable to Residential Customers for all natural gas provided at one Point of Delivery and measured through one meter. Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be required prior to service being furnished. Monthly Rate Customer's monthly bill will be calculated by adding the following Customer and Ccf charges to the amounts due under the riders listed below: Charge Amount Customer Charge per Bill $ 19.10 per month Rider CEE Surcharge $ 0.02 per month1 Total Customer Charge $ 19.12 per month Commodity Charge -All Ccf $0.11378 per Ccf Gas Cost Recovery: Plus an amount for gas costs and upstream transportation costs calculated in accordance with Part (a) and Part (b), respectively, of Rider GCR. Weather Normalization Adjustment: Plus or Minus an amount for weather normalization calculated in accordance with Rider WNA. Franchise Fee Adjustment: Plus an amount for franchise fees calculated in accordance with Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality. Tax Adjustment: Plus an amount for tax calculated in accordance with Rider TAX. Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s). Agreement An Agreement for Gas Service may be required. Notice Service hereunder and the rates for services provided are subject to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service. 1Reference Rider CEE -Conservation and Energy Efficiency as approved in GUD 10170. Surcharge billing effective July 1, 2015. Ordinance No. 2016-3776 Page 4 of 14 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: C -COMMERCIAL SALES Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 06/01/2016 I PAGE: 13 Application Applicable to Commercial Customers for all natural gas provided at one Point of Delivery and measured through one meter and to Industrial Customers with an average annual usage of less than 30,000 Ccf. Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be required prior to service being furnished. Monthly Rate Customer's monthly bill will be calculated by adding the following Customer and Ccf charges to the amounts due under the riders listed below: Charge Amount Customer Charge per Bill $41.75 per month Rider CEE Surcharge $ 0.02 per month1 Total Customer Charge $41.77 per month Commodity Charge -All Ccf $ 0.08494 per Ccf Gas Cost Recovery: Plus an amount for gas costs and upstream transportation costs calculated in accordance with Part (a) and Part (b), respectively, of Rider GCR. Weather Normalization Adjustment: Plus or Minus an amount for weather normalization calculated in accordance with Rider WNA. Franchise Fee Adjustment: Plus an amount for franchise fees calculated in accordance with Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality. Tax Adjustment: Plus an amount for tax calculated in accordance with Rider TAX. Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s). Agreement An Agreement for Gas Service may be required. Notice Service hereunder and the rates for services provided are subject to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service. 1 Reference Rider CEE -Conservation and Energy Efficiency as approved in GUO 10170. Surcharge billing effective July 1, 2015. Ordinance No. 2016-3776 Page 5 of 14 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: I -INDUSTRIAL SALES Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 06/0 1/20 16 I PAGE: 14 Application Applicable to Industrial Customers with a maximum daily usage (MDU) of less than 3,500 MMBtu per day for all natural gas provided at one Point of Delivery and measured through one meter. Service for Industrial Customers with an MDU equal to or greater than 3,500 MMBtu per day will be provided at Company's sole option and will require special contract arrangements between Company and Customer. Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be required prior to service being furnished. Monthly Rate Customer's monthly bill will be calculated by adding the following Customer and MMBtu charges to the amounts due under the riders listed below: Charge Amount Customer Charge per Meter $ 738.00 per month First 0 MMBtu to 1,500 MMBtu $ 0.3096 per MMBtu Next 3,500 MMBtu $ 0.2267 per MMBtu All MMBtu over 5,000 MMBtu $ 0.0486 per MMBtu Gas Cost Recovery: Plus an amount for gas costs and upstream transportation costs calculated in accordance with Part (a) and Part (b), respectively, of Rider GCR. Franchise Fee Adjustment: Plus an amount for franchise fees calculated in accordance with Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality. Tax Adjustment: Plus an amount for tax calculated in accordance with Rider TAX. Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s). Curtailment Overpull Fee Upon notification by Company of an event of curtailment or interruption of Customer's deliveries, Customer will, for each MMBtu delivered in excess of the stated level of curtailment or interruption, pay Company 200% of the midpoint price for the Katy point listed in Platts Gas Daily published for the applicable Gas Day in the table entitled "Daily Price Survey." Replacement Index In the event the "midpoint" or "common" price for the Katy point listed in Platts Gas Daily in the table entitled "Daily Price Survey" is no longer published, Company will calculate the applicable imbalance fees utilizing a daily price index recognized as authoritative by the natural gas industry and most closely approximating the applicable index. Ordinance No. 2016-3776 Page 6 of 14 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: I -INDUSTRIAL SALES Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 06/01/2016 I PAGE: 15 Agreement An Agreement for Gas Service may be required. Notice Service hereunder and the rates for services provided are subject to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service. Special Conditions In order to receive service under Rate I, Customer must have the type of meter required by Company. Customer must pay Company all costs associated with the acquisition and installation of the meter. Ordinance No. 2016-3776 Page 7 of 14 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: T-TRANSPORTATION Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 0610112016 I PAGE: 16 Application Applicable, in the event that Company has entered into a Transportation Agreement, to a customer directly connected to the Atmos Energy Corp., Mid-Tex Division Distribution System (Customer) for the transportation of all natural gas supplied by Customer or Customer's agent at one Point of Delivery for use in Customer's facility. Type of Service Where service of the type desired by Customer is not already available at the Point of Delivery, additional charges and special contract arrangements between Company and Customer may be required prior to service being furnished. Monthly Rate Customer's bill will be calculated by adding the following Customer and MMBtu charges to the amounts and quantities due under the riders listed below: Charge Amount Customer Charge per Meter $ 738.00 per month First 0 MMBtu to 1,500 MM Btu $ 0.3096 per MMBtu Next 3,500 MMBtu $ 0.2267 per MMBtu All MMBtu over 5,000 MMBtu $ 0.0486 per MMBtu Upstream Transportation Cost Recovery: Plus an amount for upstream transportation costs in accordance with Part (b) of Rider GCR. Retention Adjustment: Plus a quantity of gas as calculated in accordance with Rider RA. Franchise Fee Adjustment: Plus an amount for franchise fees calculated in accordance with Rider FF. Rider FF is only applicable to customers inside the corporate limits of any incorporated municipality. Tax Adjustment: Plus an amount for tax calculated in accordance with Rider TAX. Surcharges: Plus an amount for surcharges calculated in accordance with the applicable rider(s). Imbalance Fees All fees charged to Customer under this Rate Schedule will be charged based on the quantities determined under the applicable Transportation Agreement and quantities will not be aggregated for any Customer with multiple Transportation Agreements for the purposes of such fees. Monthly Imbalance Fees Customer shall pay Company the greater of (i) $0.10 per MM Btu, or (ii) 150% of the difference per MM Btu between the highest and lowest "midpoint" price for the Katy point listed in Platts Gas Daily in the table entitled "Daily Price Survey" during such month, for the MMBtu of Customer's monthly Cumulative Imbalance, as defined in the applicable Transportation Agreement, at the end of each month that exceeds 10% of Customer's receipt quantities for the month. Ordinance No. 2016-3776 Page 8 of 14 MID-TEX DIVISION ATMOS ENERGY CORPORATION RATE SCHEDULE: T-TRANSPORTATION Attachment A RRC Tariff No: APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 0610112016 I PAGE: 17 Curtailment Overpull Fee Upon notification by Company of an event of curtailment or interruption of Customer's deliveries, Customer will, for each MMBtu delivered in excess of the stated level of curtailment or interruption, pay Company 200% of the midpoint price for the Katy point listed in Platts Gas Daily published for the applicable Gas Day in the table entitled "Daily Price Survey." Replacement Index In the event the "midpoint" or "common" price for the Katy point listed in Platts Gas Daily in the table entitled "Daily Price Survey" is no longer published, Company will calculate the applicable imbalance fees utilizing a daily price index recognized as authoritative by the natural gas industry and most closely approximating the applicable index. Agreement A transportation agreement is required. Notice Service hereunder and the rates for services provided are subj ect to the orders of regulatory bodies having jurisdiction and to the Company's Tariff for Gas Service. Special Conditions In order to receive service under Rate T, customer must have the type of meter required by Company. Customer must pay Company all costs associated with the acquisition and installation of the meter. Ordinance No. 2016-3776 Page 9 of 14 Attachment A MID-TEX DIVISION ATMOS ENERGY CORPORATION RIDER: WNA-WEATHER NORMALIZATION ADJUSTMENT APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 11/01/2016 I PAGE: 41 Provisions for Adjustment The Commodity Charge per Ccf (100 cubic feet) for gas service set forth in any Rate Schedules utilized by the cities of the Mid-Tex Division service area for determining normalized winter period revenues shall be adjusted by an amount hereinafter described, which amount is referred to as the "Weather Normalization Adjustment." The Weather Normalization Adjustment shall apply to all temperature sensitive residential and commercial bills based on meters read during the revenue months of November through April. The five regional weather stations are Abilene, Austin, Dallas, Waco, and Wichita Falls. Computation of Weather Normalization Adjustment The Weather Normalization Adjustment Factor shall be computed to the nearest one-hundredth cent per Ccf by the following formula: WNAFi = Where = WNAFi = Ri = HSFi = NOD = ADD = Bli = R I (HSFi (Bli x (NOD-ADD)) + (HSFi x ADD) ) any particular Rate Schedule or billing classification within any such particular Rate Schedule that contains more than one billing classification Weather Normalization Adjustment Factor for the ith rate schedule or classification expressed in cents per Ccf Commodity Charge rate of temperature sensitive sales for the ith schedule or classification. heat sensitive factor for the ith schedule or classification divided by the average bill count in that class billing cycle normal heating degree days calculated as the simple ten-year average of actual heating degree days. billing cycle actual heating degree days. base load sales for the ith schedule or classification divided by the average bill count in that class The Weather Normalization Adjustment for the jth customer in ith rate schedule is computed as: WNAi= Where qi is the relevant sales quantity for the jth customer in ith rate schedule. Ordinance No. 2016-3776 Page10of14 Attachment A MID-TEX DIVISION ATMOS ENERGY CORPORATION RIDER: WNA-WEATHER NORMALIZATION ADJUSTMENT APPLICABLE TO: ALL CUSTOMERS IN THE MID-TEX DIVISION EXCEPT THE CITY OF DALLAS AND UNINCORPORATED AREAS EFFECTIVE DATE: Bills Rendered on or after 11/01/2016 I PAGE: 42 Base Use/Heat Use Factors Residential Commercial Base use Heat use Base use Heat use Weather Station Ccf Ccf/HDD Ccf Ccf/HDD Abilene 10.09 0.1392 98.01 0.6440 Austin 11.21 0.1551 203.36 0.8564 Dallas 13.72 0.2048 189.83 0.9984 Waco 9.89 0.1411 129.75 0.6695 Wichita 11.49 0.1506 122.35 0.5967 Falls Weather Normalization Adjustment (WNA) Report On or before June 1 of each year, the company posts on its website at atmosenergy.com/mtx-wna, in Excel format, a Weather Normalization Adjustment (WNA) Report to show how the company calculated its WNAs factor during the preceding winter season. Additionally, on or before June 1 of each year, the company files one hard copy and an Excel version of the WNA Report with the Railroad Commission of Texas' Gas Services Division, addressed to the Director of that Division. Ordinance No. 2016-3776 Page 11 of 14 File Date: March 1, 2016 ATMOS ENERGY CORP., MID-TEX DIVISION PROPOSED TARIFF STRUCTURE (BEFORE RATE CASE EXPENSE RECOVERY) TEST YEAR ENDING DECEMBER 31, 2015 (a) (b) 1 Proposed Change In Rates: 2 Proposed Change In Rates without Revenue Related Taxes: 3 4 5 6 7 Residential 8 Commercial 9 Industrial and Transportation 10 Net Revenue Requirements GUD No. 10170 11 12 13 14 Revenue Requirements $ 338,431,486 84,223,622 11,490,316 $ 434,145,424 (c) $ 29,603,205 $ 27,447,850 Allocations 77.95% 19.40% 2.65% (d) (e) (f) Schedule A Ln 1 divided by factor on WP _F-5.1 Per GUD 10170 Final Order Per GUD 10170 Final Order Per GUD 10170 Final Order (g) (h) (i) Attachm 3 Proof of Revenues 0) (k) 15 16 r.IWi""'1t�h�P�ro_p_o_rt�i-o -na�l�l-ncr�e-a-se �a�ll -c�la_s_s-es-,.b-ut�R=-e�si�d-e -nt7ia�l -a-n�d-a-470�%�,-r-e�si�d-e-nt7ia�l�b-a-s-e -c�h-a -rg-e�i-n -cr-e-a-s -e:������I With Customer Charges Rounded Off and residential base charge increase for 2015 limited to $0.50 per RRM tariff: 17 18 Current Prospective Revenues 19 20 Residential Base Charge $ 18.56 $ 0.48 $ 8,558,622 21 Residential Consumption Charge $ 0.09931 $ 0.01540 12,837,933 22 Commercial Base Charge $ 39.87 $ 1.81 2,662,423 23 Commercial Consumption Charge $ 0.08020 $ 0.00480 2,662,423 24 I& T Base Charge $ 697.35 $ 38.03 363,224 25 l&T Consumption Charge Tier 1 MMBTU $ 0.2937 $ 0.0166 172,167 26 l&T Consumption Charge Tier 2 MMBTU $ 0.2151 $ 0.0121 139,070 27 l&T Consumption Charge Tier 3 MM BTU $ 0.0461 $ 0.0026 51,988 28 $ 27,447,850 29 Ordinance No. 2016-3776 Proposed Change Residential Base Charge $ 0.52 $ Residential Consumption Charge $ 0.01447 Commercial Base Charge $ 1.83 Commercial Consumption Charge $ 0.00474 I& T Base Charge $ 39.65 l&T Consumption Charge Tier 1 MMBTU $ 0.0159 l&T Consumption Charge Tier 2 MMBTU $ 0.0116 I& T Consumption Charge Tier 3 MMBTU $ 0.0025 $ Proposed Change In Revenues 9,335,278 12,061,297 2,697, 162 2,626,475 378,728 165,150 132,888 49,955 27,446,933 Proposed $ $ $ $ $ $ $ $ Rates Proposed Revenues 19.08 0.11378 41.70 0.08494 737.00 0.3096 0.2267 0.0486 $ 339,813,673 94,839,970 61,390,268 47,065,984 7,039,815 3,215,747 2,597,042 971,117 $ 556,933,616 WP_J-5 Page 2 of 4 Page 12of14 File Date: March 1, 2016 ATMOS ENERGY CORP., MID-TEX DIVISION PENSIONS AND RETIREE MEDICAL BENEFITS ADJUSTMENT TEST YEAR ENDING DECEMBER 31, 2015 Shared Services Post- Pension Retirement Pension Mid-Tex Direct Post- Supplemental Retirement Line Account Plan Medical Plan Account Plan Executive Benefit Medical Plan No. Description (a) Fiscal Year 2016 Towers Watson Report as adjusted (1), (3) 2 O&M Expense Factor (2) 3 Fiscal Year 2016 Actuarially Determined O&M Benefits (Ln 1 x Ln 2) 4 Allocation to Mid-Tex (2) 5 Mid-Tex Benefits Expense Included in Rates -Proposed (Ln 3 x Ln 4) 6 Mid-Tex Benefits Expense per GUD 10359 and RRM Test Year Ending 7 December 31, 2014 Benchmark (4) 8 9 Test Year Adjustment (Line 5 minus Line 7) 10 11 Adjustment Summary: 12 Account 922 13 Account 926 14 Total (Ln 12 plus Ln 13) 15 16 17 Notes: 18 1. Studies not applicable to Mid-Tex or Shared Services are omitted. $ $ $ $ $ $ $ ("PAP") ("FAS 106") (b) (c) 5,101,680 $ 2,896,450 $ 96.41% 96.41% 4,918,540 $ 2,792,473 $ 40.56% 40.56% 1,995,016 $ 1,132,659 $ 2,831,859 $ 2,013,260 $ (836,844) $ (880,601) $ (836,844) $ (880,601) $ (836,844) $ (880,601) $ 19 2. The factors on Lines 2 and 4 are based on the factors in 2016 RRM (Test Year Ending December 31,2015). 20 3. SSU amounts exclude cost centers which do not allocate to Mid-Tex for rate making purposes. ("PAP") Plan f"SERP"l (d) (e) 7,840,683 $ 150,433 $ 37.42% 20.77% 2,933,599 $ 31,249 $ 71.52% 100.00% 2,098,222 $ 31,249 $ 2,925,600 $ 34,809 $ (827,379) $ (3,561) $ $ $ (827,379) (3,561) (827,379) $ (3,561) $ 21 4. GUO No. 10359 is the benchmark for January-May which is the same benchmark as used in the RRM TYE December 31, 2014 for June-December. Ordinance No. 2016-3776 ("FAS 106") (f) 4,466,430 37.42% 1,671,119 71.52% 1, 195,248 $ 2,695,721 $ (1,500,472) $ $ (1,500,472) (1,500,4r2) $ Attachment C Adjustment Total (g) 6,452,393 10,501,250 (4,048,856) (1,717,445) (2,331,412) (4,048,856) WP_F-2.3 Page 1 of 2 Page 13 of14 Line No. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ATMOS ENERGY CORP., MID-TEX DIVISION PENSIONS AND RETIREE MEDICAL BENEFITS FOR CITIES APPROVAL TEST YEAR ENDING DECEMBER 31, 2015 Shared Services Pension Post-Retirement Pension Mid-Tex Direct Supplemental Account Plan Medical Plan Account Plan Executive Benefit Descriotion ("PAP") ("FAS 106") ("PAP"l Plan ("SERP"l (a) (b) (c) (d) (e) Fiscal Year 2016 Towers Watson Report (excluding Removed Cost Centers) $ 5,101,680 $ 2,896,450 $ 7,840,683 $ 150,433 Allocation to Mid-Tex 40.56% 40.56% 71.52% 100.00% FY16 Towers Watson Benefit Costs (excluding Removed Cost Centers) Allocated to MTX (Ln 1 x Ln 2) $ 2,069,299 $ 1,174,833 $ 5,607,955 $ 150,433 O&M and Capital Allocation Factor 100.00% 100.00% 100.00% 100.00% FY 16 Towers Watson Benefit Costs To Approve (excluding Removed Cost Centers) (Ln 3 x Ln 4) $ 2,069,299 $ 1,174,833 $ 5,607,955 $ 150,433 Summary of Costs to Approve: Total Pension Account Plan ("PAP") $ 2,069,299 $ 5,607,955 Total Post-Retirement Medical Plan ("FAS 106") $ 1,174,833 Total Supplemental Executive Retirement Plan ("SERP'') $ 150,433 Total (Ln 10 + Ln 11+Ln 12) $ 2,069,299 $ 1,174,833 $ 5,607,955 $ 150,433 O&M Expense Factor 96.41% 96.41% 37.42% 20.77% Expense Portion (Ln 13 x Ln 16) $ 1,995,016 $ 1,132,659 $ 2,098,222 $ 31,249 Capital Factor 3.59% 3.59% 62.58% 79.23% Capital Portion (Ln 13 x Ln 20) $ 74,283 $ 42,174 $ 3,509,733 $ 119,184 Total (Ln 18 + Ln 22) $ 2,069,299 $ 1,174,833 $ 5,607,955 $ 150,433 Ordinance No. 2016-3776 Attachment C Post-Retirement Medical Plan Adjustment ("FAS 106"} Total (f) (g) $ 4,466,430 71.52% $ 3,194,561 100.00% $ 3, 194,561 $ 12,197,081 $ 7,677,254 $ 3,194,561 4,369,394 150,433 $ 3,194,561 $ 12, 197,081 37.42% $ 1,195,248 $ 6,452,393 62.58% $ 1,999,313 $ 5,744,687 $ 3,194,561 $ 12, 197,081 Page 14 of 14