Loading...
HomeMy WebLinkAboutStaff Comments r 1 1101 Texas Avenue, P.O. Box 9960 _ College Station, Texas 77842 Phone 979.764.3570/Fax 979.764.3496 CITY OF COLLEGE STATION MEMORANDUM August 14, 2007 TO: Adam J. Brumbaugh, RME Consulting Engineers, via fax: 979-690-0329 FROM: Jennifer Prochazka, AICP, Senior Planner SUBJECT: ALLSAFE STORAGE PH2 (SP)- Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised site plans One (1) landscaping plan One (1) 11x17 grading and erosion control plan Easement Dedication Sheet and required documents (please allow 4 weeks to process). Please note that the Easement Dedication Sheet and necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments pc: M.P. Texas Properties, LLC, c/o Pete Kountakis, via fax: 979.774.1236 Case file #07-00500183 NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 1 of 3 STAFF REVIEW COMMENTS NO. 1 Project: ALLSAFE STORAGE PH2 (SP)— 07-00500183 PLANNING 1. Please provide Non-Residential Architectural standard details, including: NRA application, a copy of building elevations for all buildings, color samples, and list of all building materials (in legend form, as shown in Section 7.9 of the UDO). The information needed is included on the site plan checklist. Please use the requirements for sites with over 50,000 square feet of building. This will also affect building footprint. 2. Please include the required sidewalks and tree wells at the fronts of buildings (Section 7.9.E). 3. Please include location and details of required bicycle facility (NRA). 4. Is the property line shown the new right-of-way line for FM 2154? 5. Please provide a curb and pavement detail on the site plan. 6. Please better distinguish between existing improvements in Phase I and proposed improvements in Phase II. 7. Please provide all setbacks on the site plan. 8. Please label throat depth. Minimum is 55 feet. 9. Please be aware that because the drive aisles between structures is only 30 feet, and the fire lane minimum is 20 feet, no parking will be allowed in these areas. 10. Please show distance from structures to single-family lot lines. Please be aware that according to the UDO Section 7.1.H Height, the structure shown can only be a height of 1/2 the distance. 11. Please provide overall height of structures on the site plan. 12. Provide a general note that all roof and ground-mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right-of-way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 13. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Jennifer Prochazka Date: August 6, 2007 LANDSCAPING/STREETSCAPING/BUFFER 1. According to Section 7.9. E.3, landscape points must be doubled for this site. 2. Please provide irrigation information. 3. Sizes of canopy and non-canopy trees should be given in caliper inches for a single cane measured at 12" above grade. 4. Is the buffer already installed behind phase II? Please show plantings (indicate whether existing or proposed). 5. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock, or a perennial grass is required in parking lot islands, swales and drainage areas, the parking lot setback, rights-of-way, and adjacent property disturbed during construction. Reviewed by: Jennifer Prochazka Date: August 6, 2007 NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 2 of 3 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double-Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. FIRE DEPARTMENT 1. Please detail any gates or fencing for fire access. Reviewed by: Steve Smith Date: August 14, 2007 ENGINEERING COMMENTS NO. 1 1. Revise/modify drawings to fit within current property lines. (Hasn't TxDOT already acquired ROW?) 2. Verify that the detention pond is functioning as designed. Provide any modifications necessary (regrading, silt removal, etc.) 3. Verify that there is enough room between the fire hydrant and the wrought iron fence for fire department to access/operate properly. 4. Add erosion control measures to detention pond outlet pipe. Reviewed by: Carol Cotter Date: August 10, 2007 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: July 31, 2007 GENERAL ELECTRICAL COMMENTS 1. Existing electrical service was installed to include future development. 2. Developer provides digital AutoCAD 2000 or later version of plat and/or site plan. Email to: sweido@cstx.gov. 3. Developer provides load data for project. 4. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 8-1-07 NOTE: Any changes made to the plans,that have not been requested by the City of College Station,must be explained in your next transmittal letter and"bubbled"on your plans. Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 3 of 3