HomeMy WebLinkAboutApplication P&Z CASEFORNOOFFIC.: U('•//C�U_SE �
DATE SUBMITTED: /A i -/1i
CITY OF COLLEGE STATION I , ►I 5
Planning d Development Services
DEVELOPMENT PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P&Z Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
N/A Filing Fee of$400.00
N/A Development Permit Application Fee of$200.00 (if applicable).
N/A Infrastructure Inspection Fee of$600.00 (applicable if any public infrastructure is being constructed)
X Application completed in full.
X Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Final Plat. (if applicable)
X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Two (2) copies of public infrastructure plans associated with this plat (if applicable).
X Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
APPLICATION DATA
Date of Required Preapplication Conference: November 22, 2005
NAME OF SUBDIVISION Olden Homeplace
SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block) North of Rock Prairie Road 3200
feet west of the intersection of Rock Prairie Road and Greens Prairie Road.
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name David R. Mayo (Joe Orr, Inc.)
Street Address 2167 Post Oak Circle City College Station
State Texas Zip Code 77845 E-Mail Address dmayoaa.myriad.net
Phone Number 979-690-3378 Fax Number N/A
PROPERTY OWNER'S INFORMATION:.
Name Dolly C. Olden
Street Address 7804 Rock Prairie Road East City College Station
State Texas Zip Code 77845 E-Mail Address N/A
Phone Number 979-690-6819 Fax Number N/A
ARCHITECT OR ENGINEER'S INFORMATION: Surveyor
Name Joe Orr, Inc.
Street Address 2167 Post Oak Circle City College Station
6/13/03
Page 1 of 3
State Texas Zip -ode 77845 E-Mail Addrb .., dmavo(c mvriad.net
Phone Number 979-690-3378 Fax Number N/A
Acreage - Total Property 28.99 acres Total # Of Lots 1 R-O-W Acreage 0.13 acres
Existing Use: Agriculture Proposed Use: Agriculture
Number Of Lots By Zoning District 1 / AO / /
Average Acreage Of Each Residential Lot By Zoning District:
28.86 /AO
Floodplain Acreage 0.00
A Statement Addressing Any Differences Between The Development Plat and the Final Plat: (If Applicable):
N/A
Requested Variances To Subdivision Regulations & Reason For Same:
None
Requested Oversize Participation: None
Total Linear Footage of Parkland Dedication due prior to filing the Final Plat:
Proposed Public: ACREAGE:
0 Streets # of acres to be dedicated + $ development fee
0 Sidewalks #of acres in floodplain
0 Sanitary Sewer Lines #of acres in detention
0 Water Lines #of acres in greenways
0 Channels OR
0 Storm Sewers FEE IN LIEU OF LAND:
0 Bike Lanes / Paths f #of Single-Family Dwelling Units X $556 = $ J�t�
(date) Approved by Parks & Recreation Board
NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true, correct, and complete. The undersigned hereby requests approval by the City of College
Station of the above-identified final plat and attests that this request does not amend any covenants or
restrictions associated with this plat.
' a-�= P2 ,Owner December 2, 2005
Signatur and Title Date
6/13/03
Page 2 of 3
SUBMIT APPLICATION AND THIS
4:if" LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
CITY OF COLLEGE STATION
Planning&Development Services
DEVELOPMENT PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers.)
�f 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
9 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
X 3. Title Block with the following information:
M. Name and address of subdivider, recorded owner, planner, engineer and surveyor.
IV Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Property that has been previously platted must retain
original subdivision name.)
114 Date of preparation.
KEngineer's scale in feet.
Total area shown on development plat.
Tgt 4. North Arrow.
5. Subdivision boundary indicated by heavy lines.
1,4II 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or
larger.
7. All applicable certifications
Ownership and Dedication
Surveyor and/or Engineer
`g Planning and Zoning Commission
Brazos County Clerk
0 Brazos County Commissioners Court Approval (ETJ Plats only)
121. 8. Paid tax certificates.
Dit 9. If using private septic systems, add a general note on the plat that no private sewage facility may
be installed on any lot in this subdivision without the issuance of a license by the Brazos County
Health Unit under the provisions of the private facility regulations adopted by the Commissioner's
Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
0 li 10. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent
available data.
U 11. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
X12. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming a
boundary with the subdivision, as well as, those within the subdivision).
6/13/03 4 of 5
t
Existing Proposed
❑ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp
turn around unless they are shorter than 100 feet.
X ❑ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
N IC ❑ Street offsets and/or intersection angles meet ordinance.
E ❑ A number or letter to identify each lot or site and each block.
:J ❑ Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
/� ❑ Building, structure or improvement or proposed modification of the external configuration
of the building, structure, or improvement.
❑ Each easement and right-of-way, including alleys, within or abutting the boundary of the
surveyed property.
N [t ❑ Any part of the property intended to be dedicated to public use of for the use of
purchasers or owners of lots frontingon or tothe adjacent sidewalk, alley, square, park,
or other part.
I1/4)
15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed
ili
by a Licensed Texas Professional Engineer that include the following:
❑ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall
street, alley and/or sidewalk layout of the subdivision. (may be combined with other
utilities).
❑ Sanitary sewer plan and profile showing depth and grades. One sheet must show the
overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the
utility master plan and any future growth areas.)
❑ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing
depth and grades. One sheet must show the overall water layout of the subdivision.
(Utilities of sufficient size/depth to meet the utility master plan and any future growth
areas.)
❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and
drainage channels, with profiles and sections. Drainage and runoff areas, and runoff
based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design,
channel lining design & detention if used. One sheet must show the overall drainage
layout of the subdivision.
❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
❑ Drainage Report.
❑ Erosion Control Plan (must be included in construction plans).
16. All off-site easements necessary for infrastructure construction must be shown on the
development plat with a volume and page listed to indicate where the separate instrument
easements were filed. Separate instrument easements must be filed prior or concurrently with
development plat.
X17. Are there impact fees associated with this development? ❑ Yes No
Impact fees for R-1, R-2, & R-3 zoned development plats, must be paid prior to filing.
18. Will any construction occur in TxDOT rights-of-way? ❑ Yes No
If yes, TxDOT permit must be submitted along with the construction docum6nts.
NOTE: 1. We will be requesting the corrected development plat to be submitted in digital form if available
prior to filing the plat at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted
prior to issuance of a development permit.
6/13/03 5 of 5