HomeMy WebLinkAboutOpen Record RequestKristen Hejny
From: Kristen Hejny
Sent: Tuesday, November 18, 2014 7:57 AM
To:'rperez@williamsassociatespc.com'
Subject: RE: Building and Plumbing pemmit question Wood/8001914220
Attachments: 4890_001.pdf
Hi Rosalia,
Please see the attached building permit and plumbing permit issued for the home at 1509 Fairhaven Cv. in 2005.
Let me know if you have any questions.
Kristen Hejny
Staff Assistant
City of College Station
Planning and Development Services
PCS Box 9960
1101 Texas Ave
College Station, Texas 77840
khejny_@cst_x,_goy
979-764-3570 Phone
979-764-3496 Fax
From
i_
Rosalia Perez rTiito r
..__. i)erez(is, illiaiiisa_5>Ot VciL�OO I
' ()i. ClIJ
Sent: Friday, November 14, 2014 5:34 PM
To: cspds
Subject: Building and Plumbing pemmit question Wood/8001914220
Hello,
My name is Rosalia and I am trying to obtain a copy of the building and plumbing permit for the
address listed below, the home was built in 2005. 1 don't need the plans or anything like that just
the permits or the application for the permits would work; essentially I need the Contractor and
subcontractor information. Please let me know if you have any questions or concerns. Thank you
in advance for your time and efforts .
Address: 1509 Fairhaven cove
College Station, TX 77845
Owner: Joy Wood
Claim# 8001914220
Rosalia Perez
Williams and Associates, PC
711 Mall Ring Circle Suite 101
Henderson, NV 89014
Toll Free: 1-877-331-9463
Main:(702) 331-4010 ext.230
Fax:(702) 331-4011
Email: rDe'rez (@,will iannsassociatesrx,corn
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840.>
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 05-00000245 Date 11/17/14
Propert Address . . . . 1509 FAIRHAVEN CV
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . FAIRHAVEN COVE
Pro ppert Use . . . . . . . RESIDENTIAL
Application valuation . . . . 94380
Owner Contractor
------------------------ ------------------------
SUNSET HOMES
JOHN ALBERNAZ
3946 ARBOLEDA DR
COLLEGE STATION TX 77845
(979) 680-1033
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy T pe RESIDENTIAL-SFR/DUPLEX
Other struc info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NO. OF GARAGE BAYS 1.00
HEATED AREA 1430.00
INTERIOR WALL TYPE SHEETROCK
NO. OF BATHROOMS 2.50
NO. OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 262.00
----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 347617
Permit Fee . . . . 440.00
Issue Date . . . . 2/11/05 Valuation . . . . 94380
Expiration Date . . 8/10/05
Qty Unit Charge Per Extension
BASE FEE 260.00
45.00 4.0000 THOU BLDG, VAL 50001-100000 180.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
------------------------------------------- FILE-CURY ------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Pae 2
Application Number . . . . . 05-00000245 Dae 11/17/14
----------------------------------------------------------------------------
Special Notes and Comments
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2003 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL PUBLIC
SEWER SERVICE IS PROVIDED OR APPROVED ALTERNATE SEWER
SYSTEM IS INSTALLED
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Pa e 3
Application Number . . . . . 05-00000245 Dae 11/17/14
----------------------------------------------------------------------------
Special Notes and Comments
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2003 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION.
Assure roper house placement, all setbacks tight because
of right side easement
Fully sheathed APA portal wall bracing method to be used
add wall elect. recepticles in bedrooms #2 & #3
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 440.00 440.00 .00 .00
Grand Total 440.00 440.00 .00 .00
------------------------------------------- FILE tap -y ------------------
BUILDING DEPT REPRESENTATIVE:
PLUMBING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE COLLEGE STATION, TX 77840
PHONE: (979f764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 05-00000245 Date 11/17/14
Proppert Address . . . . 1509 FAIRHAVEN CV
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . FAIRHAVEN COVE
Proppert Use . . . . . . . RESIDENTIAL
Application valuation . . . . 94380
Owner Contractor
------------------------
------------------------
SUNSET HOMES
JOHN ALBERNAZ
3946 ARBOLEDA DR
COLLEGE STATION
TX 77845
--- Structure
Information
000 000 SINGLE FAMILY680-1033
Construction
Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy
Other structs
Tpe
info . .
RESIDENTIAL -SFR DUPLEX
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NO. OF GARAGE BAYS
1.00
HEATED AREA
1430.00
INTERIOR WALL TYPE
SHEETROCK
NO. OF BATHROOMS
2.50
NO. OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
262.00
----------------------------------------------------------------------------
Permit.
. .
PLUMBING PERMIT
Additional
desc . .
SS
Permitpin
number
349258
Sub Contractor
CURRY PLUMBING
Permit Fee
. . . .
90.00
Issue Date
. . . .
2/23/05 Valuation . .
. . 0
Expiration
Date . .
8/22/05
Qty
Unit Charge
Per
Extension
BASE FEE
20.00
3.00
4.0000
EA PLBG, WATER CLOSET
12.00
1.00
4.0000
EA PLBG, WATER HEATER
4.00
4.00
4.0000
EA PLBG, LAVATORIES
16.00
1.00
4.0000
EA PLBG, KITCHEN SINK
4.00
2.00
4.0000
EA PLBG, BATH TUB
8.00
1.00
4.0000
EA PLBG, SHOWER
4.00
1.00
4.0000
EA PLBG, DISHWASHER
4.00
1.00
4.0000
EA PLBG, FLOOR DRAIN
4.00
1.00
5.0000
EA PLBG, WATER SERVICE OR REPLACE 5.00
--------------------------------------------- FILE -CORY ----------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
PLUMBING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE COLLEGE STATION, TX 77840
PHONE: (979f764-3570 FAX: (979) 764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Pa e 2
Application Number . . . . . 05-00000245 Dae 11/17/14
Qt Unit Charge Per Extension
1.OD
5.000 EA PLBG, SEWER COLL OR REPLACE 5.00
1.00 4.0000 EA PLBG, WASHING MACHINE 4.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 90.00 90.00 .00 .00
Grand Total 90.00 90.00 .00 .00
------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE: V,
• • y _kill