Loading...
HomeMy WebLinkAboutROWP Notice of Proposed Installation rMeM Utility Line on Non-Controlled Access Highway onn 102J�� (Rev.&2002) (GSD-EPC) Pepe 1of2 To the Texas Transportation Commission Date August 31,2005 do District Engineer Texas Department of Transportation Bryan ,Texas Formal notice is hereby given that Southcorp Holdings 1, L.P. do Southcorp Realty Advisors Company proposes to place a water line&sanitary sewer force main line within the right of way of FM 2818 in Brazos County, Texas as follows: (give location,length,general design,etc.) 1.) 140 If 12"AWWA C-909 Class 200 PVC water line across F&B Road,parallel to FM 2818(plan sheet WL-1 of 2) 2.) 1230 If 4"AWWA C-909 Class 200 PVC sanitary sewer force main along FM 2818(plan sheets SS-1,2,&3 of 5) 3.) 350 If 4"AWWA C-909 Class 200 PVC and ductile iron sanitarty sewer force main across FM 2818(plan sheet SS-3 of 5) The line will be constructed and maintained on the highway right of way as shown on the attached drawing and in accordance with the rules,regulations and policies of the Texas Department of Transportation(TxDOT), and all governing laws, induding but not limited to the"Federal Clean Water Act,"the"National Endangered Species Act,"and the'Federal Historic Preservation Act." Upon request by TxDOT,proof of compliance with all governing laws, rules and regulations will be submitted to TxDOT before commencement of construction. Our firm will use Best Management Practices to minimize erosion and sedimentation resulting from the proposed installation,and we will revegetate the project area as indicated under 'Revegetation Special Provisions." Our firm will ensure that traffic control measures complying with applicable portions of the Texas Manual of Uniform Traffic Control Devices will be installed and maintained for the duration of this installation. The location and description of the proposed line and appurtenances is more fully shown by 2-11"x17" complete sets of drawings attached to this notice. Construction of this line will begin on or after the September 1,2005 Month/Day/Year By signing below, I certify that I am authorized to represent the Firm listed below, and that the Firm agrees to the conditions/provisions included in this permit. Southcorp Holdings 1,L.P. do Southcorp Realty Advisors Firm Name sAik-Cia on �.�.� \\.`Ivan Signature RRreeident JAt Qres. Title 3401 Allen Parkway, Suite 200 _ Address Houston TX 77019 City, State Zip (713) 960-1880 Area Code Telephone Number 1611111.4 A1/4‘' q/jg1c Form 1023 (Rev.812002) Page 2 of 2 APPROVAL Notice No.: To: Southcorp Holdings 1, L.P. Hwy. No. FM 2818 3401 Allen Parkway, Suite 200 Beg. RM Offset Houston, Texas 77019 End RM Offset Attn: David Hillman (713) 960-1880 Brazos County,Texas MNT Sec. No. 002 Date October 12, 2005 TxDOT offers no objection to the location on the right of way of your proposed 4"x 1,585' Force Main & 12"x 140'Water lines as shown by accompanying drawings and notice dated September 20, 2005 except as noted below. It is expressly understood that TxDOT does not purport, hereby, to grant any right, claim, title, or easement in or upon this highway; and it is further understood that TxDOT may require the owner to relocate this line, subject to provisions of governing laws, by giving thirty(30) days written notice. You are requested to notify this office prior to commencement of any routine or periodic maintenance which requires pruning of trees within the highway right of way, so that we may provide specifications for the extent and methods to govern in trimming, topping, tree balance, type of cuts, painting cuts and clean up. These specifications are intended to preserve our considerable investment in highway planting and beautification, by reducing damage due to trimming. The installation should not damage any part of the highway and adequate provisions must be made to cause minimum inconveniences to traffic and adjacent property owners. In the event the Owner fails to comply with any or all of the requirements as set forth herein, the State may take such action as it deems appropriate to compel compliance. • General Special Provisions: SEE ATTACHMENTS • Revegetation Special Provisions: In order to minimize erosion and sedimentation resulting from the proposed installation, the project area will be revegetated ® in accordance with TxDOT's Standard Specification Item 164 which specifies the appropriate grass seed mix to be used or ❑ as indicated on the attachment. Please notify Mr. Ronnie Waller, Maintenance Section 778-8054 forty-eight (48) hours prior to starting construction of the line in order that we may have a representative present. Karl Nelson, P.E. Bryan TxDOT Bryan Area Engineer District ! — (979) 778 -6233 ignature Area Code Telephone Number r0-tc-o5— October 21, 2005 RE: FM 60(North ROW) FM 2818 to East(1,000')(Research Parkway) Valley Park Center Subdivision College Station, Texas Utility Permit - 4"x 1,585' (CI 200) Sanitary Sewer Force Main w/10" Casing 12"x 140' (CI 200) PVC Waterline w/20" Casing + 18" GV+ 12" GV+ FH GENERAL SPECIAL PROVISIONS (Utility Permit) : 1) Traffic Control plan is required per TMUTCD prior to start of construction work in the FM 60 & FM 2818 right-of-ways. 2) Areas within ROW disturbed by construction shall be restored to equal or better conditions than existing prior to construction. 3) Contractor shall be responsible for locating all utilities within the right-of-way construction site. Contacts with local utility companies and utility locators are required. 4) Sanitary Sewerline (Force Main) shall be located as indicated (4' minimum bury; 10' max. from FM 2818 ROW line & 5' from FM 60 ROW line). 5) Longitudinal lines without a metal sheath shall have a durable metal wire, etc. installed concurrently for detection purposes. 6) Paved driveways, streets, etc. within ROW shall be bored at force main, water line, etc. x-ings; unpaved driveways to be open-cut shall be restored to equal or better conditions than existing prior to construction. All permanent structures, etc. crossings shall be bored. 7) Encasement(10"x 20') shall be provided for bore under 5' x 4' SBC(Sta.10+40+/-). 8) Bend (4") @ Sta. 11+99 may be required to be 30° in lieu of 221/2°. 9) Crossing of FM 2818 shall be encased as indicated (10" x 153'). Force main (4")ti not encased, shall be ductile iron pipe, as indicated. Top of casing shall be 36" below roadway ditches. 10) Bore pits in the right-of-way shall be a minimum of 30' from edge of pavement & shall not remain open overnight. 11) Force Main (4") & Water line (12") construction shall be as per City of College Station Standard Details & Specifications. 12) Gate Valves(18" &12")shall be located within 10'of ROW line. 13) Fire Hydrants(2)shall be located within 5' of ROW line. 14) Backfill shall be placed in 12" lifts, and compaction density shall be equal to the surrounding area. 15) Pavement surface shall be kept clear of mud, debris, etc.