Loading...
HomeMy WebLinkAboutStaff Comments (4*. ff 1444 CITY OF COLLEGE STATION Planning el Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 12, 2005 TO: Strong Engineering, via fax: 731-0096 FROM: Lindsay Boyer, Project Manager SUBJECT: SQUID HILL (FP) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, September 19, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for, October 20, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Development Plat application and additional $100 fee; Two (2) 24"x36" copies of the revised final plat; Twelve (12) 11"x17" copies of the revised final plat; Parkland Dedication in the amount of$ must be submitted prior to the filing of the final plat; One (1) Mylar original of the revised final plat; and One (1) copy of the digital file of the final plat on diskette or e-mail to nmanhart@cstx.gov Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Tiersa Hopkins via fax: 764-5872 Case file #05-00500153 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: SQUID HILL (FP) - 05-00500153 ENGINEERING 1. This plat must be processed as a Development Plat, otherwise fire flow regulations will apply to the plat. (A Minor Plat can be approved at staff level, but all provisions of the subdivision regulations must be met, including Fire Flow. Per the Subdivision Regulations there specifically no provision to allow a variance to Fire Flow.) Please return with a completed Development Plat application, the title block corrected, and additional $100 for processing. Please be aware that a Development Plat must be heard by the Planning and Zoning Commission. Based on date of submittal, and the Parks Board schedule, this plat will be scheduled for the October 20th meeting. 2. Please provide a note as to how water and wastewater are being provided to this lot. 3. Parkland Dedication must be provided. Please contact Pam Springfield with Parks and Recreation in order to be placed on the Parks Board agenda (764-3773). This plat may not go before Planning and Zoning until it has been heard by the Parks Board. 4. As a point of information for the owner and as noted above, a Development Plat may be processed without providing fire flow. However, once a building permit is requested, fire flow must be provided per the Fire Code. At that point, a variance may be sought from the Construction Board of Appeals. Generally, the Fire Marshall's office would make a recommendation as to Fire Flow variances. The $480 fee for the Construction Boards of Appeals may be waived for areas in the most recently annexed area. Reviewed by: Lindsay Boyer/Alan Gibbs Date: September 8, 2005 ELECTRICAL 1. Property is in the Bryan Texas Utilities Electric service territory. 2. To discuss any of the above electrical comments, please contact Tony Michalsky at 979.764.3438. Reviewed by: Tony Michalsky Date: September 8, 2005 BTU 1. BTU will require 20' easements centered on any existing overhead distribution lines on the property, a 20' easement along the three side property lines, and 16 feet along the front parallel to Jones-Butler. 2. Please identify all easements that currently exist on this property. Reviewed by: Randy Trimble Date: September 12, 2005 NOTE: Any changes made to the plans,that have not been requested by the City of College Station, must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 2 of 2 (Ariffu" CITY OF COLLEGE STATION Planning cl Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM October 3, 2005 TO: Curtis Strong, Strong Surveying, via fax: 979-731-0096 FROM: Lindsay Boyer, Project Manager SUBJECT: SQUID HILL (FP) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information: Two (2) 24"x36" copies of the revised final plat; Parkland Dedication in the amount of$556 must be submitted prior to the filing of the final plat; and One (1) Mylar original with the appropriate signatures. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Tiersa Hopkins, via email: tiersahopkins@msn.com Case file #05-00500153 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 2 Project: SQUID HILL (FP) - 05-00500153 ENGINEERING 1. Please correct the City Planner certificate. Under the signature line, it shows Bryan, Texas. 2. FYI: This plat will be placed on the October 11th Parks Board meeting. Your attendance is not required. After speaking with Ric Ploeger, he is certain Parks will accept a fee in lieu of land dedication for the property. This amount of $556 must be paid prior to filing of the plat. Assuming all conditions are met, the plat would be filed following October 11th Reviewed by: Lindsay Boyer/Alan Gibbs Date: September 27, 2005 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 2