Loading...
HomeMy WebLinkAboutApplication FOR OFFICE USE (ONNL P&Z CASE NO.: b9 "1 CITY OF COLLEGE STATION DATE SUBMITTED: LA " Planning dr Development Services PRELIMINARY PLAT APPLICATION The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X Filing Fee of$400.00. N/A Variance Request to Subdivision Regulations — $100 (if applicable) X Application completed in full. X Thirteen (13)folded copies of plat. (A revised mylar original must be submitted after staff review.) N/A One (1) copy of the approved Master Plan if applicable. X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. N/A Rezoning Application if zone change is proposed. N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: Unknown NAME OF SUBDIVISION: Villages of Indian Lakes SPECIFIED LOCATION OF PROPOSED SUBDIVISION: End of Arrington Road in Brazos County in the J.M. Barrera Suveys, A-68 and A-69 and in the H.G. Hudson Survey, A-141 APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name: Travis Martinek Street Address: 3608 East 29th Street, Suite 100 City: Bryan State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com Phone Number: (979) 846-4384 Fax Number: (979) 846-1461 PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name: Smiling Mallard Development, LLC Street Address: 3608 East 29th Street, Suite 100 City: Bryan State: Texas Zip Code: 77802 E-Mail Address: travis@clarkewyndham.com Phone Number: (979) 846-4384 Fax Number: (979) 846-1461 ARCHITECT OR ENGINEER'S INFORMATION: Name: McClure & Browne, Inc. Street Address: 1008 Woodcreek Drive, Suite 103 City: College Station State: Texas Zip Code: 77802 E-Mail Address: mikem@mcclurebrowne.com Phone Number: (979) 693-3838 Fax Number: (979) 693-2554 6/13/03 1 of4 Total Acres Of Subdivision: 1,397.24 R-O-W Acreage: 49.18 utal # Of Lots: 197 Number Of Lots By Zoning District: N/A Average Acreage Of Each Residential Lot By Zoning District: N/A Floodplain Acreage: 25 Parkland dedication by acreage or fee? N/A A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable) None Requested variances to subdivision regulations & reason for same: See Attachment A Requested oversize participation: None Parkland Dedication due prior to filing the Final Plat: ACREAGE: #of Acres to be dedicated # of acres in floodplain #of acres in detention # of acres in greenways OR FEE IN LIEU OF LAND: #of Single-Family Dwelling Units X $556 = $ __ (date)Approved by Parks & Recreation Board The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that all respective owners have been identified on this application. //!PAS Travis Martinek Date Design & Construction Manager 6/13/03 2 of 4 ATTACHMENT A: Phase IX of this Preliminary Plat represents a proposed patio home community. The project will consist of 44 lots that range in size from 0.17 ac to 0.36 ac. Each lot will obtain access from the private drive (as shown on the plat). The patio home community's homeowner's association will assume maintenance of the private drive once construction is complete. The conditions of this maintenance will be further outlined within the homeowner's association's Covenants, Codes, & Restrictions document during the Final Platting process. The lots within Phase IX are less than 1-acre and will be unable to qualify for Onsite Sewage Facility permits. The developer is currently in the process of obtaining a Wastewater Treatment Plant Permit from the Texas Commission on Environmental Quality and plans to construct a package wastewater treatment plant to serve the needs of the patio home community. The proposed location of this facility is shown on the Preliminary Plat. The developer is proposing to allow the private drive to additionally serve as a utility easement to accommodate, waterlines, sanitary sewer lines, and storm drainage (through the use of inverted-crown street design). A 10' Public Utility Easement along the fronts of the lots is proposed to allow for the installation of electric service, gas lines, etc. The majority of the street drainage is planned to exit the site via drainage outlets that will direct the water downstream to Lake Arapaho. If you have any further questions regarding the proposed patio home development, please contact Travis Martinek (846-4384) GrillirrdrSUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW CITY OF COLLEGE STATION Planning&Development Services PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: Z 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. Allowed to submit at 1:200 scale (per Bridgette George on 4/15/05) due to the volume of paper required to submit at 1:100 scale. ® 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. ® 3. Title Block with the following information: ® Name and address of subdivider, recorded owner, planner, engineer and surveyor. ® Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) ® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) ® Engineer's scale in feet. ® Total area intended to be developed. ® 4. North Arrow. ® 5. Location of current city limit lines and current zoning district boundary. ® 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. ® 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) ® 8. Primary control points or descriptions and ties to such control point, to which , later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original survey of which it is a part. ® 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. ® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 6/13/03 3 of • • 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. • 12. Proposed land uses (In compliance with Land Use Plan). • 13. Proposed zoning changes, if any, submit formal rezoning request. • 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed ® Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. ® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) • ® Street offsets and/or intersection angles meet ordinance. • ® Alleys. ® ® Reserve tracts. • ® Well site locations. ® ® Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product transported through the line. • Z Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient size/depth to meet the utility master plan and any future growth areas. ® ® Easements. ® ® Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. ® ® A number or letter to identify each lot or site and each block. ® ® Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) ® ® Public areas • ® Other public improvements, including but not limited to parks, schools and other public facilities • 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision.. • 16. Are there impact fees associated with this development? ❑ Yes ® No • 17. If requesting oversize participation items, are the necessary impact studies included? ❑Yes ❑No ®N/A 6/13/03 4 of 4 CITY OF COLLEGE STATION *** CUSTOMER RECEIPT *** Oper: LHOWE Type: CT Drawer: 1 Date: 4/18/05 00 Receipt no: 204944 Description Iluantit PL ;--r Cn�T Y Amount L PLANNING AND TONING 1.00 4400.00 SMILING MALLARD PP INDIAN LAKES LH CK 3686 Tender detail CK PERSONAL 3686 Total tendered 8409.99 Total payment 8409.99 8409.90 Trans date: 4/18/05 rime: 9:36:13 THANK YOU