Loading...
HomeMy WebLinkAbout14-108_Page_21BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Pa e 6 Application Number . . . . . 12-00001538 Dae 8/11/14 ---------------------------------------------------------------------------- Sp*ecial Notes and Comments * All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-wa or residential district within 150 feet of the subject lo�, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screenin rooftop equipment may include, but are not limited ?o encasement, parapet walls, or partition screens. * ALL OUTDOOR LIGHTING WITHIN DEVELOPMENTS OTHER THAN SINGLE-FAMILY RESIDENTIAL AND DUPLEXES SHALL MEET THE REQUIREMENTS OF SECTION 7.10 OF THE UNIFIED DEVELOPMENT ORDINANCE. LIGHT FIXTURES -THE LIGHT SOURCE (LIGHT BULB)SHALL NOT PROJECT BELOW AN OPAQUE HOUSING. NO FIXTURE SHALL DIRECTLY PROJECT LIGHT HORIZONTALLY. FIXTURES SHALL BE MOUNTED IN SUCH A MANNER THAT THE PROJECTED CONE OF LIGHT DOES NOT CROSS ANY PROPERTY LINES. ** PROVIDE VISUAL AND AUDIBLE SIGNAL DEVICE, MOUNTED IN A NORMALLY OCCUPIED AREA FOR EACH RETURN AIR DUCT SMOKE DETECTOR FOR EACH UNIT GREATER THAN 2000 CFM IN A BUILDING WITHOUT AN APPROVED FIRE ALARM SYSTEM, PER NFPA 90A CHAPTER 6. PROVIDE RETURN AIR DUCT SMOKE DETECTOR FOR ALL UNITS GREATER THAN 2000 CFM. *** WHEN CONSTRUCTION PLANS ARE SEALED BY AN ARCHITECT OR ENGINEER, THE INSTALLATION SHALL COMPLY WITH SEALED PLANS. IF DURING CONSTRUCTION, A PROPOSED FIELD CHANGE SHALL BE COMMUNICATED TO THE DESIGN PROFESSIONAL, REVISED SEALED PLANS OR LETTER SUBMITTED TO BUILDING DEPT OFFICE AND REVIEWED PRIOR TO DESIGN CHANGE INSTALLATION. INSPECTIONS ARE BASED UPON CURRENT CODE & ON -FILE APPROVED SEALED CONSTRUCTION DOCUMENTS. ANY & ALL UN -AUTHORIZED FIELD CHANGES WILL NOT PASS BUILDING DEPT INSPECTION. ** AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE ** CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR AT (512)463-3211, WWW.LICENSE.STATE.TX.US/ABPROJECTREGISTRATION FOR MORE INFORMATION. ** INSTALL FULL -OPEN SHUT-OFF VALVE ON WATER DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE INTO THE STRUCTURE, ON THE DISCHARGE SIDE OF EVERY WATER METER, SECTION 606 OF IPC. *** WINDOWS SHALL COMPLY WITH 2012 IECC: --- ----------- -- ---- - - - - -- 11 BUILDING DEPT REPRESENTATIVE: r1 �,C n n, APPLICANT: 1