HomeMy WebLinkAbout14-108_Page_11BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (9http://bpinspect3570 .ccstx.gov764-3496 ---------------------------------------------------------------------------- We 5 Application Number . . . . . 12-00001227 e 8/11/14 ---------------------------------------------------------------------------- Special Notes and Comments WATER CLOSET SHALL BE 18" FROM SIDE WALL. PROVIDE MINIMUM 60" WIDE X 56" DEEP CLEARANCE FOR ACCESSIBLE WATER CLOSET AND ALSO A 60" TURNING DIAMETER CIRCLE CLEARANCE. *** HANDRAILS SHALL COMPLY WITH SECTION 1012 OF THE 2012 IBC. HANDRAIL HEIGHT SHALL BE MOUNTED BETWEEN 34"-38" ABOVE STAIR TREAD NOSINGS AND FINISH RAMP WALKING SURFACE. PROVIDE HANDRAILS ON BOTH SIDES AND HANDRAIL EXTENSIONS AT THE TOP & BOTTOM OF EACH FLIGHT OF STAIRS OR RAMPS. *** PROVIDE PROTECTION FOR EXIT DOORS & REQUIRED EGRESS PATH, STRUCTURES, DUMPSTER ENCLOSURES, MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT FROM IMPACT OR BLOCKED BY AUTOMOBILES. *** SEE GENERAL INSPECTION CHECKLIST FOR COMMERCIAL, MULTI -FAMILY, AND/OR MIXED OCCUPANCY BUILDINGS. INSPECTION CHECKLIST AVAILABLE AT PLANNING & DEVELOPMENT SERVICES, CITY HALL, CITY OF COLLEGE STATION. (1101 TEXAS AVENUE) *** PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR EACH SHELL BUILDING DOOR AND/OR TENANT ENTRY DOOR IS REQUIRED. CONTACT FIRE MARSHAL'S OFFICE (979)764-3705. ** REQUIRED EMERGENCY EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE/EFFORT. STOREFRONT EXIT DOORS WITHOUT A THUMB -LATCH REQUIRE STATEMENT "DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" ON THE DOOR WITH 1 INCH LETTERS. WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *** INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE LIMIT REQUIREMENTS OF CHAPTER 4 OF THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE. *** PROVIDE LIGHTING REDUCTION CONTROLS (ABLE TO REDUCE ROOM/AREA LIGHTING BY AT LEAST 50 PERCENT)IN EACH ROOM WITH MORE THAN ONE LIGHT FIXTURE PER SECTION C405.2.1.2 OF IECC. *** PROVIDE AUTOMATIC TIME SWITCH CONTROLS AND OCCUPANCY SENSORS PER SECTIONS C405.2.2.1 & C405.2.2.2 OF IECC. ** All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-wa or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. ----------------- BUILDING DEPT REPRESENTATIVE: 'Aff APPLICANT: