Application Number . . . 12-00001227----------- -Dae---8/11/14
-----------------------------------------
Sppecial Notes and Comments
TO THE FIRE MARSHAL'S OFFICE, (979)764-3705.
NO WORK ON SPRINKLER SYSTEM SHALL
BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED.
SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE
REQUIRED TO BE MONITORED BY AN APPROVED MONITORING
COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE
SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE
PREVENTION DIVISION. KNOX CAP REQUIRED ON ANY FIRE
SPRINKLER SYSTEM SUPPORTED BY AN F.D.C.
*** GUARDRAILS SHALL COMPLY TO SECTION 1013 OF 2012 IBC.
HEIGHT SHALL BE NO LESS THAN 42" AND OPENINGS SHALL NOT
ALLOW THE PASSAGE OF A 4" SPHERE.
*** POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD OR
PARKING LOT.
*** ANY CHANGES OR ALTERATIONS TO APPROVED BUILDING PLANS
MUST BE RE -SUBMITTED AND APPROVED BEFORE WORK IS DONE IN
ORDER TO ASSURE CODE COMPLIANCE.
*** PROVIDE SANITARY FACILITIES/PORTA-CAN FOR WORKERS ON
SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY (STREET &
SIDEWALKS)
*** CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00PM AND
7:OOAM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA).
*** ALL IRRIGATION, PLUMBING, ELECTRICAL, MECHANICAL (HVAC)
WORK MUST BE PERFORMED BY A LICENSED CONTRACTOR. CONTACT
BUILDING DEPARTMENT FOR PERMITS PRIOR OR WORK, AND
INSPECTIONS PRIOR TO COVERING ANY & ALL WORK, (979)764-3570.
*** ELECTRICAL SHALL BE INSTALLED PER 2011 NATIONAL
ELECTRICAL CODE AND LOCAL AMENDMENTS. ASSURE PROPER GFI
LOCATIONS, INCLUDE ONE WITHIN 25 FEET OF OUTSIDE A/C UNITS.
*** ALL CONSTRUCTION INSTALLATIONS SHALL COMPLY WITH THE
2012 INTERNATIONAL CODES, AND LOCAL AMENDMENTS
*WWW.CSTX.GOV).
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAX. STATIC WATER PRESSURE TO 80 PSI OR LESS.
*** SAFETY GLAZING REQUIRED IN WINDOWS WITHIN 24" OF DOORS
IN ADJACENT WALLS, WITHIN 60" ADJACENT TO TUBS & WITHIN 60"
ABOVE WALKING SURFACE, ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE; COMPLY WITH SECTION
2406 OF 2012 IBC.
*** PROVIDE MINIMUM 42" CLEARANCE FROM CENTERLINE OF WATER
CLOSET TO EDGE OF LAVATORY, WALL, OR OTHER OBJECT TO COMPLY
WITH ICC/ANSI A117.1, ACCESSIBLE STANDARDS. CENTERLINE OF
------------------------------
------------------------------------------------
BUILDING DEPT REPRESENTATIVE: —�
APPLICANT: