HomeMy WebLinkAboutStaff CommentsCOLLEGE STATION P. O. Box 9960 1101 Texas Avenue College Station, TX 77842 Teh. 409 764 3500 MEMORANDUM May 20, 2000 TO: Stephen Cast, Wellborn S.U.D., Via fax (979) 690-1260 FROM: Bridgette George, Asst. Development Coordinator ~ ~~~ d_, SUBJECT: Wellborn Special Utility District -Conditional Use Permit Site Plan Staff reviewed the above-mentioned site plan as requested but had to stop review due to an incomplete submittal. The following page is a list of preliminary staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, June 5, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for June 15, 2000, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Two (2) copies of the revised site and landscape plan. If you would like to meet with staff to review the comments on the site plan, please let me know and I will set up a meeting. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: J. F. Fontaine & Associates, Inc., Via fax (903) 729-7310 Case file #00-85 Home of Texas A&M University is CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 /Fax (979) 764-3496 MEMORANDUM July 7, 2000 TO: Stephen Cast, Wellborn S.U.D., Via fax 690-1260 FROM: Bridgette George, Asst. Development Coordinator ~~` SUBJECT: Wellbvrrl SUD WaterBoosterPlant #2 -Conditional Use Permit Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Wednesday, July 12, 10:00 a.m., to be placed on the Agenda for the next Planning & Zoning Commission meeting scheduled for Thursday, July 20, 2000, 7:00 p.m.: $150 Conditional Use Permit fee; Ten (10) copies of the revised site and landscape plan; and, (2) Copies of the erosion control plan. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: J. F. Fontaine & Associates, Inc. Via fax (903) 729-7310 Case file #00-85 Home of Texas A&M University COLLEGE STATION P. O. Box 9960 1101 Texas Avenue CoNege Station, TX '7"7£342 Tel; 409 764 3500 MEMORANDUM June 29, 2000 TO: Stephen Cast, Wellborn S.U.D., via fax 690-1260 FROM: Bridgette George, Asst. Development Coordinator SUBJECT: Wellborn S.U.D. Water Booster Plant #2 -Conditional Use Permit Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed prior to the Planning & Zoning Commission meeting next Thursday, July 6. Please address the comments and submit the following information for further staff review and presentation to the Commission: Two (2) copies of the revised site and landscape plan. Please call me when you receive this memo to discuss the comments. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: J. F. Fontaine & Associates, Inc., Via fax (903) 729-7310 Case file #00-85 ~,~,9-~. u~ ~ 5~~-G~~. ~ao~ ~/~~ . ~ ,~ ~ r~~~,y,~ ~ ~-u~ ~e Home of Texas A&M University STAFF REVIEW COMMENTS No. 1 Project: WELLBORN SUD BOOSTER PLANT (CUP) (0-85) Review Stopped: Incomplete Submittal - No Landscaping Plan submitted. Submittal with a Conditional Use Permit Application should be a site plan not a preliminary plat. In the predevelopment meeting it was determined that only a Conditional Use Permit and a Final Plat would be required for this site. The following comments do not constitute a complete site plan review. 1. Both sheets need to show a north arrow, if you choose to resubmit with information on two sheets. 2. Clearly label the property lines on both sheets. 3. Label fire hydrant on both sheets. 4. Scale needs to be a standard engineering scale. Usually not greater than 1:100. Not 1":1 mile as on the sheet prepared by Orr. The sheet prepared by Fontaine has 2 different scales shown. 1:15 is not a standard _ scale. ~5. i Show landscape reserve and proposed landscaping plan. 1 ~r~~a. ~',;~~"' C~~ 6. Show the building setbacks. In A-O zoned areas, they are 50' in front, 15' on a side street and none for the rear of the property. The existing building should be considered a legal non-conformity. The water tank as a utility facility, as opposed to a habitable building or structure, will not be required to meet setbacks. 7. Are there any existing easements on the property? `~~ Provide dimensions for existing improvements, including height. C(9~ Provide R.O.W. widths for Greens Prairie and Arrington Roads. 10. Clearly show how the existing concrete drive connects to the pavement on Greens Prairie Rd. (length, width & surface) ~~ Provide distances to opposite and adjacent driveways and streets from proposed and existing drives. 12. Gravel drives are not permitted per ordinance. 13. Commercial drives should be a minimum of 24 feet wide. The driveway ordinance allows the City Engineer (or his designee) to "override the recommended dimensions set forth in this policy if warranted by specific traffic conditions." It ~ be possible to determine that this proposed drive is only a service maintenance drive for which a 12-foot width is 9-'J acceptable. To make that determination -How often are inspections and r. ae maintenance required? What size are the trucks that will be required? ~'~ This area should be designated as a service area, not a parking area. a ~~~?~ c rl~~ ~~ J:~PZTEXT~PZ03070.DOC Page 1 of 1 What are the dimensions of this area? This area should provide adequate room for service vehicles to turn around, so that there are no backing maneuvers onto Arrington. 14. Gravel areas are only allowed in rare circumstances when there will be no access to the public and the area is completely screened from public view. 15. Fence type? Is it a screening fence? 0ln~n~. (,~-~- ~~ ~-~''~ ~~~ 16. Show proposed grading and provide drainage report. 17. What are the water tank and pumphouse going to look like? Color and material? With the subject property's close proximity to such a prominent intersection it is anticipated that the Planning and Zoning Commission will be interested in the screening and the aesthetics of the property. 18. Building permits will not be issued until property is final platted. Reviewed by: Jessica Jimmerson Date: 19-May-00 J:~PZTEXTlPZ03070.DOC Page 2 of 1 .~ ~- ~~ STAFF REVIEW COMMENTS No. 2 Project: WELLBORN SUD BOOSTER PLANT (CUP) (0-85) e~' ~ ~~ ~~o 1~~ l~ ~ 5. The landscape reserve line should be shown 24 feet back from the property ~ ~~~~~~,\, ~~ ~~. lines along Greens Prairie and Arrington Rds. The proposed landscaping °:~/~' ~.., ~- does not meet the ordinance for required landscaping or streetscaping. _ ~~°~ ~°~~ ~ . Irrigation is required for all new plantings. ~,~~.~'`'~~~ 6. Show the building setbacks. In A-O zoned areas, they are 50' in front, 15' on a side street and none for the rear of the property. The existing building should be considered a legal non-conformity. The water tank as a utility facility, as opposed to a habitable building or structure, will not be required to meet setbacks. 8. What is the height of the existing building? 11. Provide distances to opposite and adjacent driveways and streets from proposed and existing drives. 12. Gravel drives are not permitted per ordinance. 13. Commercial drives should be a minimum of 24 feet wide. The driveway ~~ ~"'`"b~~o, ordinance allows the City Engineer (or his designee) to "override the ~- recommended dimensions set forth in this policy if warranted by specific ~~~~__-n-~a~ traffic conditions." It may be possible to determine that this proposed drive is ~'o-~~ only a service maintenance drive for which a 12-foot width is acceptable. ~f9 ~d- ok°~-U~. 15. Chain link with wooden slats is not considered screening fencing, but it will gybe up to the Commission to decide if full screening fencing will be required. c_v-.~bv'"~ NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Reviewed by: JESSICA JIMMERSON Date: 06/28/00 ,_..r- I ( «s~ . "- C~-fi-~n) (J:~P~EXT\PZ03297.DOC ' ~~,~r~ Page 1 of 1 STAFF REVIEW COMMENTS No. 2 Project: WELLBORN SUD BOOSTER PLANT (CUP) (0-85) 5A. The landscape reserve line should be shown 24 feet back from the property lines along Greens Prairie and Arrington Rds. 5B. The proposed landscaping does not meet the ordinance for required landscaping or streetscaping. Provide landscaping legend showing required landscaping and streetscaping points and the number and type of plants proposed to meet those requirements. 50% of landscaping points must be canopy trees. streetscaping is required along Arrington Road to minor arterial standards. If the vault shown along Greens Prairie is above ground, it should be screened. Irrigation is required for all new plantings. 6. Show the building setbacks. In A-O zoned areas, they are 50' in front, 15' on a side street and none for the rear of the property. The existing building should be considered a legal non-conformity. The water tank as a utility facility, as opposed to a habitable building or structure, will not be required to meet setbacks. 8. What is the height of the existing building? 12. Gravel drives are not permitted per ordinance. 13. The driveway ordinance allows the City Engineer (or his designee) to "override the recommended dimensions set forth in this policy if warranted by specific traffic conditions." Variances to the surface material and width are being allowed, because of the low frequency of use (one pick-up size maintenance truck once a day) and because the public will not have access to the site. Commercial drives should be 24 - 36 feet wide per ordinance; a width of 16 feet will be permitted in this instance. Concrete is usually the required material; here asphalt will be permitted. The location of the driveway will need to meet adjacent driveway spacing requirements for a collector, which is 185 feet from Greens Prairie Road. 15. Chain link with wooden slats is not considered screening fencing, but it will be up to the Commission to decide if full screening fencing will be required. 19. In the upper left-hand corner the plan erroneously states that the property is .036 acres not .36 acres. J:\PZTEXT\PZ03297.DOC Page 1 of 1 Note: If in the future, the use of the Fire Department building changes and the truck access point is removed from Greens Prairie Road, the site will need to fully comply with the driveway ordinance. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Reviewed by: JESSICA JIMMERSON Date: 06/28/00 J:\PZTEXT\PZ03297.DOC Page 2 of 1 STAFF REVIEW COMMENTS No. 3 Project: WELLBORN SUD BOOSTER PLANT (CUP)-CONDITIONAL USE PERMIT (0-85) PLANNING There are additional streetscaping point requirements above and beyond the basic landscaping points. Staff calculations show that a little more than 800 additional points are required for this site. Please remember that shrubs have a point value of 10pts for each 5 gallon plant. Reviewed by: JESSICA JIMMERSON Date: 07/07/00 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 1 of 1