Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Open Record Request
Open Records Request# 140501 Name of Requestor:Jessica Oxford - Nova Consulting \4. (.., \ Open Records Routing Date/Time Received: 5/1/2014 11:45 am Date/Time Sent Out: 5/1/2014 12:45 pm CC: John Haislet - Legal Rita Stivors - Legal Kristen Hejny - Planning and Development Services Marisia Dominguez - Fire Bart Humphreys - Fire Send all responsive records to Legal along with copies of any correspondence with the requestor. Once Legal has received records from all City Departments they will communicate the status of the release to the requestor. Police and Fire Departments are exempt from this request. Sherry Mashburn City Secretary City of College Station 979) 764-3541 From: Kristen Hejny Sent: Thursday, May 01, 2014 11:40 AM To: Pubrequest Subject: FW:� Pub|\cReco/dsRequest Follow up Flagged Please see request below. I will complete the parts P&DS is responsible for. Kristen Hejny Staff Assistant City of College Station Planning and Development Services 1101 Texas Ave POBox V860 College Station Texas 77840 kh_ejnT@bx.gvv 979-764-3570 Phone 979-764-3496 Fax From: Morgan Hester Sent:Thursday, May 01,2014 11:32 AM To: Kristen Hejny Subject: FW: Public Records Request Are you the right person to send this to? Morgan Hester Staff Planner Planning & Development Services City of College Station P.D. Box 9960 l |O| Texas Avenue College Station, TX 77842 Office:979.764.3570 Fax: 979.764.3496 Email: mhestek@cstx.gov COLLEGE STATION x ♦ s* fit 1 193 i4 2013 City of College Station : 75th Anniversary From: Jessica Oxford [mailto:Jessica.Oxford©novaconsultinq.com] Sent:Thursday, May 01, 2014 11:31 AM To: Bart Humphreys; Bridgette George; POC Subject: Public Records Request Hello, I am conducting a Phase I Environmental Site Assessment for the Hampton Inn located at 320 Texas Avenue South, in College Station. I am interested in records and permits for spills/releases reported at the site, and hazardous materials storage or waste for the site,and underground storage tank information. Also,original building permits/information, and the number and types of permits issued for the site. If I need to submit a request to someone specifically,or fill something out, I will. I will be in town, but it won't be for very long and I am not sure if I will be able to make it into your offices. If there is a way to get electronic copies of permits related to the site that would be great! Thank you! F NOVk Jessica Oxford Project Manager Nova Consulting Group, Inc. 384 East 200 South American Fork,UT 84003 Phn: 801-358-6912 Fax 952-448-9572 Eml: Jessica.oxford(a�novaconsultinq.com Web:www.novaconsultinq.com 2 Kristen Hejny From: Kristen Hejny Sent: Thursday, May 01, 2014 12:55 PM To: 'jessica.oxford@novaconsulting.com' Subject: RE: ORR 140501 Attachments: 14-61.pdf Jessica, Please see attached information regarding the building permits for the address at 320 Texas Avenue. Let me know if you have any additional questions. Kristen Hejny Staff Assistant City of College Station Planning and Development Services 1101 Texas Ave PO Box 9960 College Station,Texas 77840 khejny@cstx.gov 979-764-3570 Phone 979-764-3496 Fax 1 • BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (97.9) 764-3570 ' FAX: (979) 764-3496 http: //bpinspect .cstx.gov, Application Number . . . . . 10-00001432 Date 5/01/14 Property Address .. . . . 320 TEXAS AVE Tenant nbr, name . . HAMPTON` INN Application type description COMMERCIAL, REMODEL/RENOVATION Subdivision Name . . . GORZYCKI ' S MEADOWLAND Proppert Use Application valuation . . . 154609 • Owner Contractor W2007 EQI COLLEGE STATION TAYLOR CONSTRUCTION CO PARTNERSHIP LP % W2007 EQUITY 10260 HWY 57 INNS REALTY LLC PO BOX 77110201020 r(O0C)W854-5907 TN 38057 77--- Structure Information 000 000 INTERIOR RENOVATION OF HOTEL LOBBY Construction Type COMBUSTIBLE (PROTECTED) Occupancy Type RESIDENTIAL-HOTEL/MOTEL Other struct info IMPACT/PRORATA FEES PAID n/a HEATED AREA 2090 . 00 INTERIOR WALL TYPE sheetrock SEWER TYPE public Permit BUILDING PERMIT Additional desc . AC Permit pin number 720433 Permit Fee . . . 625 . 00 Issue Date 6/02/10 Valuation . . . . 154609 Expiration Date . . 12/25/10 Qty Unit Charge Per Extension BASE FEE 460 . 00 55 . 00 3 . 0000 THOU BLDG, VAL 100001-500000 165 . 00 Special Notes and Comments THIS PERMIT IS FOR THE INTERIOR REMODEL OF AN EXISTING HOTEL LOBBY AREA. PROVIDE ADDRESS ON COMMERCIAL BUILDINGS-FRONT: 5" ADDRESS NUMBERS, AND ON REAR DOOR(S) : 2" HIGH ADDRESS NUMBERS AND NAME OF BUSINESS . FOR MULTI-FAMILY RESIDENTIAL PROVIDE UNIT NUMBER ON FRONT DOOR AND IDENTIFY EACH UNIT FROM A REAR FIRE LANE. IDENTIFY MULTI-FAMILY BUILDINGS WITH 12" BUILDING NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES . ALL NUMBERS AND LETTERS SHALL HAVE CON BASTING BACKGROUNDS . ** INSTALL EMERGENCY LIGHTING IN ALL COMMON AREAS, CORRIDORS, EGRESS PATHES, AND EXTERIOR ' EXIT DISCHARGE' LANDING AREAS AT EACH EXIT DOOR TO COMPLY WITH SECTION BUILDING DEPT REPRESENTATIVE: FILE-CO-P-Y APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gay Pae 2 Application Number 10-00001432 Date 5/01/14 Special Notes and Comments 1006 . 3 OF 2009 IBC. ** INSTALL EXIT SIGNS IN LOCATIONS AND ILLUMINATED PER SECTION 1011 OF THE 2009 IBC. SEE BUILDING CODES AND NOTES ON CITY STAMPED APPROVED BUILDING PLANS FOR EXIT SIGN LOCATIONS . ** PROVIDE EXTERIOR LANDING (60" X 60" FOR ACCESSIBILITY) LEVEL WITH THE INTERIOR FLOOR AT EACH REQUIRED EXIT DOOR. ** SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND APPROVED BY LOCAL FIRE MARSHAL' S OFFICE, (979) 764-3705 . ** PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL' S OFFICE (MIN. 2A10BC) ** PROVIDE FIRE-RATED DOORS & WINDOWS WHEN INSTALLED WITHIN FIRE-RATED WALL ASSEMBLIES THAT COMPLY WITH TABLES 715 .4 & 715 . 5 OF 2009 IBC. ** SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW TO THE FIRE MARSHAL' S OFFICE, (979) 764-3705 . NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. KNOX CAP REQUIRED ON ANY FIRE SPRINKLER SYSTEM SUPPORTED BY AN F.D. C. ** POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD OR PARKING LOT. ** ANY CHANGES OR ALTERATIONS TO APPROVED BUILDING PLANS MUST BE RE-SUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE. ** PROVIDE SANITARY FACILITIES PORTA-CAN FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-O -WAY (STREET) . ** CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10 : 00PM AND 7 : 00AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) . ** ALL IRRIGATION, PLUMBING, ELECTRICAL, MECHANICAL (HVAC) WORK MUST BE PERFORMED BY A LICENSED CONTRACTOR. CONTACT BUILDING DEPARTMENT FOR PERMITS PRIOR OR WORK, AND INSPECTIONS PRIOR TO COVERING ANY & ALL WORK, (979) 764-3570 . ** ELECTRICAL SHALL BE INSTALLED PER 2008 NATIONAL ELECTRICAL CODE AND LOCAL AMENDMENTS . ASSURE PROPER GFI LOCATIONS, INCLUDE ONE WITHIN 25 FEET OF OUTSIDE A C UNITS . ** ALL CONSTRUCTION INSTALLATIONS SHALL COMPLY WIT THE 2009 BUILDING DEPT REPRESENTATIVE: FILE COPY APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Pae 3 Application Number 10-00001432 Date 5/01/14 Special Notes and Comments INTERNATIONAL CODES, AND LOCAL AMENDMENTS (WWW. CSTX.GOV) . ** WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAX. STATIC WATER PRESSURE TO 80 PSI . ** SAFETY GLAZING REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS, ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN, ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE; COMPLY WITH SECTION 2406 OF 2009 IBC. ** PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS . A KEY FOR EACH SHELL BUILDING DOOR AND OR TENANT ENTRY DOOR IS REQUIRED. CONTACT FIRE MARSH L' S OFFICE (979) 764-3705 . ** REQUIRED EMERGENCY EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY, TOOL, OR SPECIAL KNOWLEDGE/EFFORT. STOREFRONT EXIT DOORS WITHOUT A THUMB-LATCH REQUIRE STATEMENT "DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" ON THE DOOR WITH 1 INCH LETTERS . WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ** INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE REQUIREMENTS OF SECTION 505 OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE. PROVIDE LIGHTING REDUCTION CONTROLS (ABLE TO REDUCE BY 50 PERCENT) IN EACH ROOM WITH MORE THAN ONE LIGHT FIXTURE. ** All roof and ground-mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-wa or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance . Acceptable methods of screenin rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens . * AS PER THE ZONING ORDINANCE SECTION 12 . 3 .L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE ** CONSTRUCTION CONTRACTS OVER $50, 000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR AT (512) 463-3211, WWW.LICENSE. STATE.TX.US/ABPROJECTREGISTRATION FOR MORE INFORMATION. Fee summary Charged Paid Credited Due Permit Fee Total 625 . 00 625 . 00 . 00 . 00 Grand Total 625 . 00 625 . 00 . 00 . 00 BUILDING DEPT REPRESENTATIVE. FILE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Pae 4 Application Number 10-00001432 Date 5/01/14 BUILDING DEPT REPRESENTATIVE: FILE APPLICANT: ELECTRICAL PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Application Number 10-00001432 Date 5/01/14 Property Address 320 TEXAS AVE Tenant nbr, name HAMPTON INN Application type description COMMERCIAL, REMODEL/RENOVATION Subdivision Name GORZYCKI ' S MEADOWLAND PropertyUse Applicaion valuation . . . 154609 Owner Contractor W2007 EQI COLLEGE STATION TAYLOR CONSTRUCTION CO PARTNERSHIP LP % W2007 EQUITY 10260 HWY 57 INNS REALTY LLC PO BOX 771020 MOSCOW TN 38057 381771020 (901) 854-5907 --- Structure Information 000 000 INTERIOR RENOVATION OF HOTEL LOBBY Construction Type COMBUSTIBLE (PROTECTED) Occupancy Typ RESIDENTIAL-HOTEL/MOTEL Other struct info IMPACT/PRORATA FEES PAID n/a HEATED AREA 2090 . 00 INTERIOR WALL TYPE sheetrock SEWER TYPE public Permit ELECTRICAL PERMIT Additional desc . GS Permitin number 722439 Sub Contractor . BRITT RICE Permit Fee . . . 38 . 80 Issue Date . . . 6/09/10 Valuation . . . . 0 Expiration Date . 12/25/10 Qty Unit Charge Per Extension BASE FEE 37 . 00 90 . 00 . 0200 ELEC, ELECTRICAL NEW CONST 1 . 80 Fee summary Charged Paid Credited Due Permit Fee Total 38 . 80 38 . 80 . 00 . 00 Grand Total 38 . 80 38 . 80 . 00 . 00 BUILDING DEPT REPRESENTATIVE: APPLICANT: FILE COPY PLUMBING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Application Number 09-00003393 Date 5/01/14 Property Address 320 TEXAS AVE Tenant nbr, name INSTALL GAS LINE Application type description PLUMBING ONLY Subdivision Name GORZYCKI ' S MEADOWLAND PropertyUse Applicaion valuation . . . 0 Owner Contractor EQI COLLEGE STATION BASS PLUMBING PARTNERSHIP LP PO BOX 10684 PO BOX 771020 COLLEGE STATION TX 77842 381771020 (979) 731-8723 Other struct info IMPACT/PRORATA FEES PAID na Permit PLUMBING PERMIT Additional desc . GS Permit pin number 673277 Permit Fee . . . 10 . 00 Issue Date . . 9/10/09 Valuation . . . . 0 Expiration Date . 3/09/10 Qty Unit Charge Per Extension 1 . 00 5 . 0000 EA PLBG, GAS PERMIT FEE 5 . 00 1 . 00 5 . 0000 EA PLBG, GAS PIPING-TO 4 OUTLETS 5 . 00 Fee summary Charged Paid Credited Due Permit Fee Total 10 . 00 10 . 00 . 00 . 00 Grand Total 10 . 00 10 . 00 . 00 . 00 BUILDING DEPT REPRESENTATIVE: F4-L-E--C-IJPY APPLICANT: MECHANICAL PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Application Number 09-00003387 Date 5/01/14 Property Address 320 TEXAS AVE Tenant nbr, name REPLAC MAKE UP AREA UNIT Application type description MECHANICAL ONLY Subdivision Name GORZYCKI ' S MEADOWLAND PropertyUse Applicaion valuation . . . 26300 Owner Contractor EQI COLLEGE STATION BLESSING ENTERPRISES PARTNERSHIP LP 2308 WINECUP LN PO BOX 771020 LEAGUE CITY TX 77573 381771020 (281) 316-9091 Permit MECHANICAL PERMIT Additional desc . KH Permit pin number 673111 Permit Fee . . . 149 . 00 Issue Date . . 9/09/09 Valuation . . . . 0 Expiration Date . 6/14/10 Qty Unit Charge Per Extension BASE FEE 24 . 00 25 . 00 5 . 0000 THOU MECH, EA ADDN 1000 VALUATION 125 . 00 Fee summary Charged Paid Credited Due Permit Fee Total 149 . 00 149 . 00 . 00 . 00 Grand Total 149 . 00 149 . 00 . 00 . 00 BUILDING DEPT REPRESENTATIVE: FILfeipy APPLICANT: PLUMBING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http: //bpinspect . cstx.gov Application Number 09-00000316 Date 5/01/14 Property Address 320 TEXAS AVE Tenant nbr, name 2 WTR HEATERS Application type description PLUMBING ONLY Subdivision Name GORZYCKI ' S MEADOWLAND PropertyUse Applicaion valuation . . . 0 Owner Contractor EQI COLLEGE STATION A G PLUMBING PARTNERSHIP, LP 233 MARINO RD. PO BOX 771020 BRYAN TX 77808 381771020 (979) 778-8500 Other struct info . . . . . IMPACT/PRORATA FEES PAID NA Permit PLUMBING PERMIT Additional desc . KG Permit pin number 622233 Permit Fee . . . 28 . 00 Issue Date . . 2/03/09 Valuation . . . . 0 Expiration Date . 8/03/09 Qty Unit Charge Per Extension BASE FEE 20 . 00 2 . 00 4 . 0000 EA PLBG, WATER HEATER 8 . 00 Fee summary Charged Paid Credited Due Permit Fee Total 28 . 00 28 . 00 . 00 . 00 Grand Total 28 . 00 28 . 00 . 00 . 00 BUILDING DEPT REPRESENTATIVE: FILE DOPY APPLICANT: