March 17, 2003
TO: Joe Gattis, Ash & Browne Engineering, Inc., Via fax 846-8914
FROM: Bridgette George, Assistant Development Manager
SUBJECT: CITY LIMITS RESTAURANT (SP) - Site Plan
Staff reviewed the above-mentioned site plan as requested but had to stop review due
to an incomplete submittal. The following page is a preliminary list of staff review
comments detailing items that need to be addressed. Please address the comments
and submit the following information for further staff review:
One (1) revised site and landscaping plan; and
Easement Dedication Sheet and required documents.
Please note that the Easement Dedication Sheet and the necessary documents are
required prior to the issuance of a building permit. If there are comments that you are
not addressing with the revised site plan, please attach a letter explaining the details. If
you have any questions or need additional information, please call Jennifer Reeves at
764-3570.
Attachments: Staff review comments
cc: John Fedora, Via fax 696.0001
Case file #03-00500067
Home of Texas A&M University
STAFF REVIEW COMMENTS NO. 1
Project: CITY LIMITS RESTAURANT (SP) — 03-00500067
THIS IS A STOP REVIEW: Items that need to be addressed may affect the layout
of the site. The following comments do not constitute a full site plan review.
(PLANNING
J 1. The parking requirement for a restaurant "without" a drive thru is one parking space
per 100-sq.ft. With the proposed building being 5,261-sq.ft. This will require 81
parking spaces. This puts the site 28 parking spaces short of meeting the
requirement. It appears that the additional parking spaces will effect the site layout
Jtremendously, therefore a Staff has determined that this be a "Stop Review".
2. It looks as if you are showing tables outside by the proposed fountain area. All
seated areas must be included toward your total square footage for the parking
requirement. This will require additional parking. Please delineate the outside
seating area as part of the parking analysis.
j3. Please be aware that the subject property must be Final Platted prior to site plan
approval. Platting requirements could also directly effect the site plan layout.
A54. Please provide a vicinity map on the site plan.
. Show the zoning district of the subject property as well as the abutting parcels.
. Show all easements as proposed or as existing.
.5X7. Please note on the site plan weather or not the subject property, exist within a 100-
.Jyear flood plain or not, referencing FEMA map.
8. All end-island must be a minimum 180-sq.ft. in area. It appears that the end island
adjacent to the east property line and the first end island adjacent to the handicap
parking space does not meet this area requirement.
J9. It appears that there is not a curb between the sidewalk and the handicap parking
spaces. A curb is required.
`___.. 0. The F.D.0 must be accessible and within 75-ft. of an approved fire lane.
{,/11. The driveway entrance will need to serve as a hammer head turnaround for a fire
truck.
. A2. The proposed 18-ft. parking spaces will overhang onto the four-foot sidewalk by two
feet. The sidewalk will have to be widened.
(3. The dumpster will need to be moved further away from the east property line
��Y� because of the five-ft. buffer requirement.
J4. How are people getting from the sidewalk to the restaurant? Is this grass or some
• kind of enhanced paving?
LANDSCAPE/STREETSCAPE/BUFFERS
)(15. A five-foot planted buffer is required between commercial and commercial
development. One 2" canopy tree every 25-ft. and one-five gallon shrub every three-
ft. of buffer. These plantings will be required along the east and south property line.
NOTE: Any changes made to the plans,that have not been requested by the City of College Station, must be explained in your
next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out
to the City,will constitute a completely new review.
Page 2 of 4
:./16. Please provide a different symbol for each type of tree and shrub species on the
landscape plan.
. It appears that you are providing one five gallon shrub per parking space to screen
the R.O.W., Although this looks good on paper this will not sufficiently screen
parking from the R.O.W. Please add more shrubs to help screen the parked cars
from the R.O.W.
18. Please note on the landscape plan that an irrigation system must be approved and
installed prior to C.O.
Reviewed by: Jennifer Reeves Date: 03-13-03
ENGINEERING
1. Provide construction drawings for the public fire water line.
2. Relocate private sewer service out of Public Utility Easement.
3. A 6-inch service tap on a 6-inch sewer main is not allowed "size on size". A manhole
will be required.
4. Please show paving details make sure pavement thickness is a minimum of 6-
inches for fire lanes and the dumpster pad.
5. Lay down curbs, are not permitted.
Reviewed by: Carol Cotter Date: 03-13-03
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. Developer provides 30' of#4 rigid conduit for riser poles. Developer installs
first 10'. City installs remainder.
3. Developer pours transformer pad(s) per city specs and design.
4. Developer installs pull boxes as per city specs and design.(pull boxes
provided by the city.
5. Developer provides digital AutoCAD 2000i version of plat and/or site plan.
email to rbolinci.colleqe-station.tx.us
6. Developer provides load data for project.
7. Developer provides temporary blanket easement for construction
purposes.
8. Developer provides easements for electric infrastructure as installed for
electric lines.
Reviewed by: Ronnie Bolin Date: 3-12-03
NOTE: Any changes made to the plans,that have not been requested by the City of College Station, must be explained in your
next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out
to the City,will constitute a completely new review.
Page 3 of 4
MISCELLANEOUS
1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a
Reduced Pressure Principle Back Flow Device, or a Double-Check Back Flow
Device, and installed as per City Ordinance 2394.
2. All BackFlow devices must be installed and tested upon installation as per City
Ordinance 2394.
Reviewed by: Rob Werley
NOTE: Any changes made to the plans,that have not been requested by the City of College Station, must be explained in your
next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out
to the City,will constitute a completely new review.
Page 4 of 4
CITY OF COLLEGE STATION
(S2/1DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
COLLEGE STATION College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
May 21, 2003
TO: Joe Gattis, Ash & Browne Engineering, Inc., Via fax 846-8914
FROM: Bridgette George, Assistant Development Manager
SUBJECT: CITY LIMITS RESTAURANT (SP) - Site Plan
Staff reviewed the above-mentioned site plan as requested but had to stop
review due to an incomplete submittal. The following page is a preliminary list of
staff review comments detailing items that need to be addressed. The next
submittal will be the third and final review by staff for this round of reviews. If all
items have not been addressed on the next submittal, another $200 processing
fee will need to be submitted for the subsequent set of three (3) reviews. Please
address the comments and submit the following information for further staff
review:
One (1) revised set of construction documents with the revised site
and landscaping plans attached.
If there are comments that you are not addressing with the revised site plan,
please attach a letter explaining the details. If you have any questions or need
additional information, please call me at 764-3570.
Attachments: Staff review comments
cc: John Fedora, Via fax 696.0001
Case file #03-00500067
Home of Texas A&M University
STAFF REVIEW COMMENTS NO. 2
Project: CITY LIMITS RESTAURANT (SP) - 03-00500067
THIS IS A STOP REVIEW: Items that need to be addressed may affect the
layout of the site. The following comments do not constitute a full site plan
review.
PLANNING
I/. Please provide a vicinity map on the site plan.
2. Show the zoning district of the subject property as well as the abutting
,./(‘' parcels.
. lease identify all easements. It appears that you are not showing all of the
existing easements (located at . - ant of property).
' 4, Please note on the site . an , eather or it the subject property, exist within a
I// 100-year flood plain or : - - - - -'- • EMA map.
5. All end-island must be a minimum 180-sq.ft. in area. It appears that the end
island adjacent to the east property line and the first end island adjacent to
the handicap parking space does not meet this area requirement.
6. The F.D.0 must be accessible and within 75-ft. of an approved fire lane.
Where is the F.D.C. located?
7. The dumpster will need moved from the north and east
property line because of the
tobe five-ft. bufferfurther requirement.away
J8. All end islands must be a minimum of 180-sq.ft. in area. The end-island on
the northwest side of the dumpster does not meet this requirement, and it
must be the length of the parking space. Currently the way it is designed the
parking space will interfere with the dumpster operation. Please adjust.
9. Please identify location of the drive thru window.
LAN D SCAP E/STRE ETS CAP E/BUFFERS
/10. A five-foot planted buffer is required between commercial and commercial
development. One 2" canopy tree every 25-ft. and one-five gallon shrub every
three-ft. of buffer. These plantings will be required along the north, east and
south property line.
. Please note on the landscape plan that an irrigation system must be
approved and installed prior to C.O.
V2. Please screen along side parking spaces 1, 16 and 17. Please keep in mind
that all screening shrubs must be a minimum three feet in height at planting
stage.
3. Please adjust calculations and landscape legend accordingly:
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City,will constitute a completely new review.
2 of 3
STREETSCAPE
• Frontage minus driveway/site triangle = 160-ft.
• 160 div. 25 = 7 canopy tree's or 2-non-canopy for each.
• 160 div. 50 = 3.2 x 300 = 960 additional landscape points required.
• Total landscape points required = 2100
Please call out caliper of streetscape trees provided for point calculation.
Reviewed by: Jennifer Reeves Date: 05-08-03
ENGINEERING 7. Turn-arounds will be required on the fire lanes per Fire Marshall.7Minimum water meter size is 3/4 inches. The proposed 1/2 inch irrigation meter
will need to be changed.
. Verify your proposed water demand.
r4. Cate private water and sewer service out side the PUEs. (A 10' PUE is
required along the back of the property.)
XPlan and profile shows meters as existing. Please verify.
avement detail for fire lane is 6-inch concrete with #4 bars @ 18' OCEW.
The curb that is detailed is not allowed—
. You will need erosion control measures in the detention basin area around
/the outlet structure.
�'Show limits of structural back fill on water line profile.
Show detail for drop manhole.
1 P Ovide size of grease trap.
2 Please match legend with calls on plat. What is TP? Should it be PVMT or
TOC? What is TG? Clarify grading plan.
3. Show limits of detention pond.
14. Provide detail for pilot channel.
Reviewed by: Carol Cotter Date: May 13, 2003
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City,will constitute a completely new review.
3 of 3
f
CITY OF COLLEGE STATION
(hDEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
COLLEGE STATION College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
June 10, 2003
TO: Joe Gattis, Ash & Browne Engineering, Inc., Via fax 846.8914 i/
FROM: Bridgette George, Assistant Development Manager
SUBJECT: CITY LIMITS RESTAURANT (SP) - Site Plan
Staff reviewed the above-mentioned site plan as requested and has no comments.
Please submit the following information for the plans to be stamped approved:
Four (4) complete sets of construction documents for the proposed
development with the site and landscaping plans attached;
Two (2) site plans; and
One (1) landscaping plan.
Easement Dedication Sheet and required documents.
If you have any questions or need additional information, please call me at 764-3570.
Attachments: Staff review comments
cc: John Fedora, Via fax 696.0001
Case file #03-00500067
Home of Texas A&M University
STAFF REVIEW COMMENTS NO. 3
Project: CITY LIMITS RESTAURANT (SP) - 03-00500067
PLANNING
1. No comment.
Reviewed by: Jennifer Reeves Date: 06-02-03
ENGINEERING
1. No comments.
Reviewed by: Carol Cotter Date: June 6, 2003
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the
City,will constitute a completely new review.
2 of 2