HomeMy WebLinkAboutStaff Comments CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM June 2, 2003 TO: ✓Craig Breedlove, Via fax 979.776.6095 FROM: Bridgette George, Assistant Development Manager SUBJECT: EDELWEISS BUSINESS CTR, LOT 9 BLK 1 (FP) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, June 9, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for June 19, 2003, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Two (2) copies of the revised final plat; and, One (1) Mylar original with the appropriate signatures. If you have any questions or need additional information, please call Carol Cotter or myself at 979.764.3570. Attachments: Staff review comments cc: ./Lieven J. Van Riet, Trustee, Via fax 713.652.4926 Michael McClure, McClure Engineering Inc., Via fax 693.2554 Case file #03-00500065 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 2 Project: EDELWEISS BUSINESS CTR, LOT 9 BLK 1 (FP) - 03-00500065 ENGINEERING 1. Add note that signage (one consolidated freestanding sign) is to be shared with by Lots 7, 8 and 9 of Block 1. 2. Add 10' PUE along southeast property line. 3. The letter provided by Patrick Marek regarding the sewer service to his property (Lots 6,7&8 of Block 1) does not yet relieve the burden of the sewer to Lot 8 with the platting of Lot 9. Additional wording will be required releasing the owner of Lot 9 from extending the sewer to Lot 8 and acknowledging that any additional sewer service required through platting of Lots 6,7 & 8 will be the responsibility of Mr. Marek or the owner of said lots at the time of platting. Reviewed by: Carol Cotter Date: May 28, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2 • ITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 12, 2003 TO: Craig Breedlove, Via fax (979),776-•!15 FROM: Natalie Ruiz, Development Manar SUBJECT: EDELWEISS BUSINESS CENTER - Fina r=te at Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. You will notice that staff stopped review due to several issues that could significantly impact the final plat. Please address the staff review comments and resubmit the following by an established deadline date: Two (2) copies of public infrastructure plans for the sanitary sewer lines; $600 infrastructure inspection fee; and, 13 folded copies of the final plat. Upon receipt of the required documents, staff will perform a complete review and pursue scheduling for the next available Planning & Zoning Commission meeting. If you have any questions or need additional information, please call or myself at 764-3570. Attachments: Staff review comments cc: Lieven J. Van Riet, Trustee, Via fax (713) 652-4926 McClure Engineering, Via fax (979) 693-2554 Case file #03-00500065 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: EDELWEISS BUSINESS CENTER - 03-00500065 THIS IS A STOP REVIEW. THIS REVIEW DOES NOT CONSTITUTE A COMPLETE REVIEW. ENGINEERING 1. Extension of the public sewer system to and through the property is required. Platting of this property will isolate the 1.25-acre Fedora tract from sewer service. Extend sewer service to this tract. Provide construction documents as part of Final Plat application. 2. The preliminary plat shows sewer service being provided to Lot 8 from Lot 9. Extend sewer service to Lot 9. Provide construction documents as part of Final Plat application. 3. Please show the 55' private drainage and access easement along front of the property as shown on Preliminary Plat. 4. Change the public drainage easement along the back of the property to a private drainage easement. 5. This property will have to share signage with Lots 7 and 8 in accordance the Preliminary Plat. 6. Property is in Impact Fee Area 92-01. Impact fees are due at time of building permit. Reviewed by: Carol L Cotter Date: March 12, 2003 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer provides 30' of#4 rigid conduit for riser poles. Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design.(puil boxes provided by the city. 5. Developer provides digital AutoCAD 2000i version of plat and/or site plan. email to rbolin(a�ci.college-station.tx.us 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). Reviewed by: Ronnie Bolin Date: 3-12-03 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. Page 2 of 2