Loading...
HomeMy WebLinkAboutStaff Comments CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM March 21, 2003 TO: Joel Ross, via fax, 776.6288 FROM: Bridgette George, Assistant Development Manager SUBJECT: CRESCENT POINTE- Preliminary Plat Staff reviewed the above-mentioned preliminary plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, March 24, 5:00 p.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, April 3, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised preliminary plat; and, One (1) Mylar original of the revised preliminary plat. One (1) copy of the digital file of the preliminary plat on diskette or e-mail to nmanhart@ci.college-station.tx.us Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. If you have any questions or need additional information, please call Spencer Thompson or myself at 764-3570. Attachments: Staff review comments cc: Michael R. McClure, via fax, 693.2554, Kim Foust, via fax, 764.6377 Case file #03-00500066 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: CRESCENT POINTE - 03-00500066 ENGINEERING 1. Please provide 10-ft PUE along northeast property boundary, Lot 1 and Lot 4. 2. Please provide 10-ft PUE along southeast property boundary, Lot 1. 3. Please provide 20-ft PUE along property boundary between Lot 1 and Lot 4, 10-ft each side. 4. Plan shows curved sewer. Please note that public sewers must comply with TCEQ requirements. Whereas our ordinance allows curved sewers the ordinance does not supercede TCEQ requirements. 5. The City requires utility extensions through properties when platting where applicable. Please show continuation of sewer through property to the east unless it is determined that said property will be served from another location. 6. Are sidewalks to be in ROW, access easements or on platted lots? Are additional access easements required on plat to allow for sidewalks? 7. Show legal specifics of Parking and Access Easements. 8. Please note that properties are adversely impacted by building line setbacks when property lines contain numerous bends, as in the case of Lot 2/ Lot 3. 9. Please note that actual location of First American Blvd must be approved by TxDOT permit. Reviewed by: Spencer Thompson Date: March 19, 2003 ELECTRICAL 1. Developer installs conduit as per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser pole(s). Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design. (pull boxes furnished by the city). 5. Developer provides digital AutoCAD 2000i version of plat and/or site plan. Email to rbolin(a ci.college-station.tx.us. 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines (including street lighting). Reviewed by: Ronnie Bolin Date: 3-12-03 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and"bubbled"on your plans.Any additional changes on these plans that have not been pointed out to the City,will constitute a completely new review. 2 of 2