No. 1
Project: SILK STOCKING LOUNGE (SP) -SITE PLAN (0 -169)
Please note: This area needs to be platted before a site plan can be approved.
PLANNING
1. Please remove all items in the legend that are not applicable to this site
plan.
2. Please show the utility service lines to the building. This requirement is to
confirm that landscaping will not be placed directly over a line.
3. Please show water meter, transformer, and NC unit locations. If the NC/
unit and transformer are visible from the ROW, they will require
landscaped screening.
4. An irrigation system is needed for the landscaping.
5. Please show the elevations in the area of the pond.
6. Please show the building setback lines.
7. Please add a note to the ambulatory ramp detail that it will meet ANSI
standards.
8. An additional 204 sq. ft. of interior islands is needed.
9. All parking islands must be curbed (which is shown on the plan), with the
majority of the area landscaped or treated with enhanced paving. Please
make the appropriate adjustments to all of the islands.
10. Please identify the curb return radii.
11. The fence around the dumpster needs to be 8' tall.
12. Show the fire lanes and related signage and striping details.
13. Please note the groundcover to be used.
Reviewed by: MOLLY HITCHCOCK Date: September 21, 2000
ENGINEERING
1. Please show calculations that ensure there is sufficient surface area for
the on -site wastewater treatment spray heads as per TNRCC regulations.
Reviewed by: Spencer Thompson Date: 09/25/00
Staff Review Comments Page 1 of 2
ELECTRICAL
1. Developer installs conduit per city spec. and design.
2. Developer provides 30' rigid pipe for riser.
3. Developer responsible for providing easements to cover all primary
electrical lines and equipment.
Reviewed by: Jennifer Reeves Date: September 20, 2000
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City will constitute a completely new review.
Staff Review Comments Page 2 of 2
STAFF REVIEW COMMENTS
No. 1
Project: SILK STOCKING LOUNGE (SP) -SITE PLAN (0 -169)
Please note: This area needs to be platted before a site plan can be approved.
PLANNING
1. Please remove all items in the legend that are not applicable to this site
plan.
2. Please show the utility service lines to the building. This requirement is to
confirm that landscaping will not be placed directly over a line.
3. Please show water meter, transformer, and NC unit locations. If the A/C/
unit and transformer are visible from the ROW, they will require
landscaped screening.
4. An irrigation system is needed for the landscaping.
5. Please show the elevations in the area of the pond.
6. Please show the building setback lines.
7. Please add a note to the ambulatory ramp detail that it will meet ANSI
standards.
8. An additional 204 sq. ft. of interior islands is needed.
9. All parking islands must be curbed (which is shown on the plan), with the
majority of the area landscaped or treated with enhanced paving. Please
make the appropriate adjustments to all of the islands.
10. Please identify the curb return radii.
11. The fence around the dumpster needs to be 8' tall.
12. Show the fire lanes and related signage and striping details.
13. Please note the groundcover to be used.
Reviewed by: MOLLY HITCHCOCK Date: September 21, 2000
ENGINEERING
1. Please show calculations that ensure there is sufficient surface area for
the on -site wastewater treatment spray heads as per TNRCC regulations.
Reviewed by: Spencer Thompson Date: 09/25/00
Staff Review Comments Page 1 of 2
ELECTRICAL
1. Developer installs conduit per city spec. and design.
2. Developer responsible for providing 30' of rigid pipe for risor.
3. Developer responsible for providing easements to cover all primary
electrical lines and equipment.
Reviewed by: Jennifer Reeves Date: September 20, 2000
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City will constitute a completely new review.
Staff Review Comments Page 2 of 2
CITY OF COLLEGE STATION
�`•� DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
COLLEGE STATION Phone (979) 764 -3570 / Fax (979) 764 -3496
MEMORANDUM
September 26, 2000
TO: Jim Allen, Via fax 846 -6006
FROM: Bridgette George, Asst. Development Coordinator
SUBJECT: Sit k Stocking Lounge Parking Lot Upgrade - Site .Plan
Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff
review comments detailing items that need to be addressed. Please address the comments and
submit the following information for further staff review:
Two (2) revised site and drainage plans attached; and,
$100 Development Permit fee.
If there are comments that you are not addressing with the revised site plan, please attach a
letter explaining the details. If you have any questions or need additional information, please
call me at 764 -3570.
Attachments: Staff review comments
Electrical layout
cc: Christian A. Galindo, Via fax 846 -8868
Case file #00 -169
Home of Texas A &M University