HomeMy WebLinkAboutApplicationa
(*h
CITY OF COLLEGE STATION
Home of Texas Ae7M University'
SITE PLAN APPLICATION
GENERAL
MINIMUM SUBMITTAL REQUIREMENTS:
$932 Site Plan Application Fee.
❑ 350 Non - Residential Architectural Standards / Northgate Building Review Application Fee (if applicable).
600 (minimum) Development Permit Application / Public Infrastructure Review and Inspection Fee. Fee is
1 % of acceptable Engineer's Estimate for public infrastructure, $600 minimum (if fee is > $600, the balance is
Xe prior to the issuance of any plans or development permit).
Application completed in full. This application form provided by the City of College Station must be used
and may not be adjusted or altered.
urteen (14) folded copies of site plan.
One (1) folded copy of the landscape plan.
® One (1) copy of the following for Non - Residential Architectural Standards building review or Northgate
Building Review (if applicable).
® Building elevations to scale for all buildings.
❑IK A list of building materials for all facade and screening.
® Color samples for all buildings or list colors to be used from the approved color palette.
Electronic copy of Site Plan e- mailed to csuelectdesign @cstx.gov.
IL Two (2) copies of the grading, drainage, and erosion control plans with supporting drainage report.
❑ Two (2) copies of the Public infrastructure plans and supporting documents (if applicable).
❑ Traffic Impact Analysis or calculations of projected vehicle trips showing that a TIA is not necessary for the
proposed request (if applicable).
❑ The attached Site Plan Non - Residential Architectural Standards Building Review and Northgate Building
Review checklists (as applicable) with all items checked off or a brief explanation as to why they are not
check off.
Date of Optional Preapplication or Stormwater Management Conference August 14, 2013
NAME OF PROJECT Discount Tire - Caprock Crossing
ADDRESS (Not yet assigned)
LEGAL DESCRIPTION (Lot, Block, Subdivision) Lot 2R, Blk 2 of Caprock Crossing Lots 1 R & 2R B/k 2 Common Areal
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary contact for the project):
Name Kevin Po /asek /James Roman E -mail Jsr@terraassoc.com
Street Address 1445 N. Loop West, Ste. 450
City Houston
FOR OFFICE� W$E �Y
CASE NO.: f ✓ � e
DATE SUBMITTED: L
TIME:
STAFF:
Zip Code 77008
Phone Number 713 - 993 -0333
PROPERTY OWNER'S INFORMATION:
Name Jesse Durden
Fax Number 713 - 993 -0743
Street Address 2809 Earl Rudder Freeway 5, Ste. 2 03
E -mail jesse.dur den@caprocktx.gov
City Col lege Station
Phone Number 979 - 49 2 -0425
Zip Code 77845
Fax Number 979- 314 -760
State Texas
State Texas
1/11 Page 1 of 11
ARCHITECT OR ENGINEER'S INFORMATION:
Name Terra Associates, Inc. - Kevin Polasek
Street Address 1445 N. Loop West, Ste. 450
City Houston
Phone Number 713 - 993 -0333
OTHER CONTACTS (Please specify type of contact):
Name
Street Address
City
Phone Number
Zip Code
Current zoning C -1 - General Commercial
Present use of property Vacant
Proposed use of property Tire Service & Retail Shop
Number of parking spaces required 34 Number of parking spaces proposed 48
Is there Special Flood Hazard Area (Zone A or Zone AE on FEMA FIRM panels) on the property? F Yes F No
This information is necessary to help staff identify the appropriate standards to review the application and will be used to
help determine if the application qualifies for vesting to a previous ordinance. Notwithstanding any assertion made,
vesting is limited to that which is provided in Chapter 245 of the Texas Local Government Code or other applicable law.
Is this application a continuation of a project that has received prior City platting approval(s) and you are requesting the
application be reviewed under previous ordinance as applicable?
FT Yes
F_ No
If yes, provide information regarding the first approved application and any related subsequent applications (provide
additional sheets if necessary):
Project Name: Caprock Crossing
City Project Number (in known):
Date / Timeframe when submitted: October 2013
E -mail kbp @terraassoc.com
E -mail
State
State Texas Zip Code 77008
Fax Number 713 - 933 -0743
Fax Number
1/11 Page 2 of 11
MULTI - FAMILY RESIDENTIAL
Total Acreage _
Floodplain Acreage
Housing Units
# of 1 Bedroom Units
# of 2 Bedroom Units
PARKLAND DEDICATION
(Fees due prior to the issuance of a Building Permit)
# of Multi - Family Dwelling Units
X$1636 =$
# of acres in floodplain
# of acres in detention
# of acres in greenways
# of 3 Bedroom Units
Date dedication approved by Parks &
# of 4 Bedroom Units Recreation Advisory Board
COMMERCIAL
FOR 2 BEDROOM UNITS ONLY
# Bedrooms = 132 sq. ft. Total Acreage 1.453
Building Square Feet 7,454
# Bedrooms < 132 sq. ft.
Floodplain Acreage
* Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government
Code may be assessed a different amount. Please contact city staff for additional information.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true
and correct.
and ' le
!l'8' °13
Date
1/11 Page 3 of 11
CERTIFICATIONS REQUIRED FOR ALL DEVELOPMENT
Owner Certification:
1. No work of any kind may start until a permit is issued.
2. The permit may be revoked if any false statements are made herein.
3. If revoked, all work must cease until permit is re- issued.
4. Development shall not be used or occupied until a Certificate of Occupancy is issued.
5. The permit will expire if no significant work is progressing within 24 months of issuance.
6. Other permits may be required to fulfill local, state, and federal requirements. Owner will obtain or show
compliance with all necessary State and Federal Permits prior to construction including NOI and SWPPP.
7. If required, Elevation Certificates will be provided with elevations certified during construction (forms at slab pre -
pour) and post construction.
sentatives to make reasonable inspections required to verify
8. Owner hereby gives consent to City repre
compliance.
9. If, stormwater mitigation is required, including detention ponds proposed as part of this project, it shall be
designed and constructed first in the construction sequence of the project.
10. In accordance with Chapter 1 of the onstruction�erosion, Ord
and sedimentation shall not be delpositedanuc'ty streets, o
to insure that all debris from c
existing drainage f Ci Enll g neer he sha be in accordance
named project. All N of the applicable cable codes and ordinances of the
and approved by the City
City of College Station shall apply. ed in the attached plans and
11. The information and conclusions of stain Station, Texas City Code, Chapter 113 documents and associated co mply with BCS Unified
e
current requirements of the y 9
Design Guidelines l T echncal
appl c codes and of the City Detai
of College ege deve
S Station and State and des
accordance with al Federal
l app
Regulations. (name or firm) is authorized for bidding purposes
12. Release of plans to
only. I understand that final approval and release of plans and development for construction is contingent on
contractor signature on approved Development Permit.
13. I, THE OWNER, AGREE APPL ICATION, CE RTIFY THAT ALL STATEMENTS HEREIN, AND IN ATTACHMENTS RE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND FOR
THE DEVELOPMENT PERR MIT IT
ACCURATE.
Property Owner(s) Date
Engineer Certification:
1. The project has been designed to ensure that stormwater mitigation, including detention ponds, proposed as part
of the project will be constructed first in the construction sequence.
2. 1 will obtain or can show compliance with all necessary Local, State and Federal Permits prior to construction
including NOI and SWPPP. Design will not preclude compliance with TPDES: i.e., projects over 10 acres may
require a sedimentation basin.
3. The information and conclusions contained in the attached plans and supporting documents comply with the
current requirements of the City of College Station, Texas City Code, Chapter 13 and associated BCS Unified
Design Guidelines. All development has been designed in accordance with all applicable codes and ordinances
of the City of College Station and State and Federal Regulations.
4. I, THE ENGINEER, AGREE NT PERMIT APPLICATION, ARE, TO THE BEST OF MY KNOWLEDGE, TRUE, AND
FOR THE DEVELOPME
ACCURATE.
10 C
Engineer Date
Page 4 of 11
1/11
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
❑ Sheet size - 24" x 36" (minimum).
❑ A key map (not necessarily to scale).
❑ Title block to include:
❑ Name, address, location, and legal description
❑ Name, address, and telephone number of applicant
❑ Name, address, and telephone number of developer /owner (if differs from applicant)
❑ Name, address, and telephone number of architect/engineer (if differs from applicant)
❑ Date of submittal
❑ Total site area
❑ North arrow.
❑ Scale should be largest standard engineering scale possible on sheet.
❑ Ownership and current zoning of parcel and all abutting parcels.
❑ The total number of multi - family buildings and units to be constructed on the proposed project site.
❑ The density of dwelling units per acre of the proposed project.
E] The gross square footage of all buildings location t o d size of the e uses within the f Building separation is a
located in a single building, shoe
minimum of 15 feet w/o additional fire protection.
Locations of the following on or adjacent to the subject site:
Designate between existing and proposed
❑ The density of dwelling units per acre of the proposed project.
❑ Phasing. Each phase must be able to stand alone to meet ordinance requirements.
❑ Buildings (Existing and Proposed).
❑ Setbacks according to UDO, Article 5.
Geography
❑ Water courses.
❑ 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site. Please note if there is none
on the site with confirming FEMA/FIRM map number.
❑ other pertinent drainage information. (If plan has too much
Existing topography (2' max or spot elevations) and
information, show drainage on separate sheet.)
El Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too
much information, show drainage on separate sheet.)
Page 7 of 11
1/11
Streets, Parking, and Sidewalks
❑ Existing streets and sidewalks (R.O.W.).
E] Existing Driveways, both opposite and adjacent to the site according to UDO, Article 7.
❑ Proposed drives. Minimum drive aisle width according to UDO, Article 7
❑ Indicate proposed driveway throat length according to UDO, Article 7
❑ Proposed curb cuts.
ets, alleys, etc.) locate existing curb cuts on the same an
F For each proposed curb cut (including driveways, stre
opposite side of the street to determine separation distances between existing and proposed curb cuts.
❑ Proposed curb and pavement detail.
❑ A 6" raised curb is required arou
stedges ocations, utility all paved
No exception will be or island, areas
planting areas, access ways, p
designated as "reserved for future parking ".
❑ Proposed medians.
❑ Proposed sidewalks (both public and private).
❑ Proposed pedestrian /bike circulation and facilities for non - residential buildings (UDO, Article 7).
❑ Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned.
❑ Designate number of parking spaces required by ordinance and provided by proposal.
❑ Handicap parking spaces.
❑ Parking Islands drawn and dimensioned with square footage calculated according to UDO, Section 7.2 or 7.9 fornon-
residential buildings.
❑ Parking setback from R.O.W. to curb of parking lot as required. not owned b the applicant or where there may be
El Wheelstops may be required when cars overhang onto property Y
conflict with pedestrian or bike facilities, handicap accessible routes or above ground utilities, signs or other conflicts.
❑ Security gates, showing swing path and design specs with colors.
❑ Guardrails. Include design and colors.
❑ Traffic Impact Analysis for non - residential development (UDO, Article 7).
❑ Please note if none is required.
❑ Will there be access from a TOOT R.O.W.? ❑ Yes X❑ No
If yes, then TOOT permit must be submitted with this application.
Easements and Utilities
❑ Easements - clearly designate as existing or proposed and type (utility, access, etc.)
❑ Utilities (noting size and designate as existing or proposed) within or adjacent to the proposed site, including building
transformer locations, above ground and underground service connections to buildings, and drainage inlets.
❑ Sewer Design Report (if applicable).
❑ Water Design Report and /or Fire Flow Report (if applicable).
❑ Drainage Report with a Technical Design Summary.
❑ Meter locations, existing and proposed (must be located in public R.O.W. or public utility easement).
❑ Provide a water and sanitary sewer legend to include
❑ Minimum water demands
❑ Maximum water demands
❑ Average water demands in gallons per minute, and
❑ Maximum sewer loadings in gallons per day
❑ Will there be access from a TOOT R.O.W.? ❑ Yes ❑x No
If yes, then TOOT permit must be submitted with this application.
Page 8 of 11
1/11
Fire Protection
❑ Show fire lanes. Fire lanes with a minimum of structure is s t more than with
150 feed from the l cu t rb l line or pavement edge of a
established if any portion of the proposed
public street or highway. Fire hydrants must
E] Show proposed and existing t on hydrants.
project, and shall be in l roved by the City Engin er Any structurehn any structure zoning d other t than R-1,
R -1A, or R -2 must be wi thin in 300 feet
of a fire hydrant as measured along a public street, highway or designated fire
lane.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface before a
building permit can be issued. ❑ No
❑ Will building be sprinkled? Yes
If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. If Yes,
❑ Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any
further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or
a structure.
Landscaping be shown
❑ Landscape plans as required n a separate sheet if too much reformation on the oDginalosite plan. I bequest requesting protected tree points, then t hose
trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in
easements.
Include information on the plans such as:
❑ required point calculations
❑ additional streetscape points required. Streetscape compliance is required all points will accrue toward total
calculations for # of street trees required and proposed (proposed
landscaping points.)
❑ proposed new plantings with points earned
❑ proposed locations of new plantings
❑ screening of parking lots, 50% of all shrubs used for screening shall be evergreen.
screening of dumpsters, concrete retaining walls, off street loading areas, utility connection points, or other
❑ areas potentially visually offensive.
❑ existing landscaping to remain
plan. Protected points will only be awarded if barricades are
show existing trees to be barricaded and barricade
El up before the first development permit is issued.
❑ Buffer as required in Article 7 of the Unified Development Ordinance.
❑ Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.
water
O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the an9 and must
systems for buildings and will be sized by city according to irrigation demand submitted by applicant
include backflow prevention protection.
❑ Is there any landscaping in TxDOT R.O.W.? ❑ Yes No
If yes, then TxDOT permit must be submitted at the time of application.
Other
❑ Common open spaces sites
❑ Loading docks
❑ Detention ponds
❑ Retaining walls
eening. Locations of dumpsters are accessible but not visible from streets or
❑ Sites for solid waste containers with scr
residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad required.)
❑ Are there impact fees associated with this development? X❑ Yes ❑ No
NOTE: Signs are to be permitted separately.
Page 9 of 11
1/11
(*t1
CITY OF COLLEGE STATION
Home of Texas A6-M University'
NRA BUILDING REVIEW MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMI TO THE FOLLO
Refer to UDO Section 7.9 Non - Residential Architectural Standards, as appropriate.
❑ Sheet size - 24" x 36" (minimum).
❑ Title block to include:
Name, address, location, and legal description
El
El
El
El
Name, address, and telephone number of applicant
Name, address, and telephone number of developer /owner (if differs from applicant)
Name, address, and telephone number of architect/engineer (if differs from applicant)
Date of submittal
❑ Scale should be largest standard scale possible on sheet.
❑ List of colors from the City of College Station color palette to be utilized or proposed equivalents.
❑ Color samples.
❑ List of materials to be utilized.
ning structure. Show placement of materials and colors on
E] Elevations of each non - residential building and scree
the facades according to LIDO Section 5.6.13 or 7.9.
❑ Include the following dimensions:
❑ Total vertical square footage minus openings (for each facade separately)
❑ Total vertical square footage of transparency (for each facade separately in Northgate)
❑ Total vertical square footage of each building material (for each facade separately)
❑ Total vertical square footage of each color (for each facade separately)
❑ Graphic representation and /or description of existing buildings in building plot to show material, color, and
architectural harmony.
Page 10 of 11
1/11