HomeMy WebLinkAboutBuilding PermitR W000 54o K e PROJECT 90 3 140 y ✓OL PLAN REVIEW NO BUSINESS OCCUPANCY REQUIREMENTS 2000 International Building Code CODE SECTION ITEM O.K., COMMENT OR N/A Table 503 Building Height and Area 0 V- 504 Height Modifications VI 505 Mezzanines f VI Y !_ 508.4 Special Unlimited Height It and > 200 ft travel to Fire 506 Area Modifications 302.3 Mixed Occupancy Separation 302.2 Accessory Use Areas 302.1.1 Incidental Use Areas Valves Controlling Water Supply 411.3 Special Amusement Buildings - Automatic Fire Detection EGRESS GENERAL 412.1 Air Traffic Control Towers Exit Capacity • Occupant 903 SPRINKLERS WHERE REQUIRED N/A 903.2.12.1 Basements > 1500 sq ft Converging Exits 903.2.12.3 Buildings Over 55 Feet in Height Travel Distance & Arrangement 507.2, 507.3 Unlimited Area of Exits Table 601 Note d Reduction of Hourly Ratings with Sprinklers Two Exits (Room or Tenant 603.1(8) Partition Material Exception for Type I and Type II Construction Space > 50 Occupants or travel Table 1004.3.2.1 Exit Access Corridor Rating > than 1004.2.5) Table 803.4 Interior Finish Classification f 907.2.2 Fire Alarms With Occupant Load of 500 or more Exit Separation ( Ys Diagonal 1004.2.4 Exit Access Travel Distance 1 903.3.1 Sprinkler Standard NFPA 13 Minimum Width of Access 905 STANDPIPES WHERE REQUIRED N/A 905.2 Standpipe Standard NFPA 14 Minimum Stair Width 905.3.1 Building With Floors 30 It above Fire Department Vehicle Access Minimum Exit Door Width 01 1. 2000 Plan Review Forms CODE ITEM O.K., SECTION COMMENT OR N/A 905.3.2 Building With Story> 10,000 sq *1 It and > 200 ft travel to Fire l v Department Vehicle Access 905.4 - 905.6 Hose Connection Location 905.9 Valves Controlling Water Supply 1001 EGRESS GENERAL 1003.2.3 Exit Capacity • Occupant Content 1003.2.2.7 Converging Exits �J 1004 Travel Distance & Arrangement of Exits tq Table 1004.2.1 Two Exits (Room or Tenant Space > 50 Occupants or travel N G > than 1004.2.5) 1004.2.5 Common Path of Travel 1004.2.2.1 Exit Separation ( Ys Diagonal N . Dimension of Building) 1004.3.2.2 Minimum Width of Access EJ Corridor a 1003.3.3.1 Minimum Stair Width 00 1003.3.1.1 Minimum Exit Door Width 01 1. Table 1005.2.2 Single Exit (One Story, 50 Occupants, and 75 ft Travel v p' / © f Distance) Table 1005.2.2 Single Exit (Two Stories, 30 Occupants, and 75 ft Travel , fil l, Distance) 1007.1 Boiler, Incinerator or Furnace N Rooms 1007.2 Refrigeration Machinery Rooms 1004.3.1.1 Aisle Width in Public Areas 1004.3.2.3 Dead End Corridor • 20 ft 9 1004.3.2 Exit Access Corridors 1004.3.2.1 Corridor Rating Page 28 of 60 - APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 Cr OP COLLE(M S1WFION (979) 764. 3570 (979) 764 -3496 FAX ADDRESS /LOCATION: / d3 DATE: APPLICATION # _ TEMP POLE # AJ .S'�n e LOT BLOCK � + S � UB � DIVISION SEC /PH BUSINESS /OWNER NAME: GCrr4RYC "/112MAk 491 2 HONE: �3 9 \ r _ CONTRACTOR /HOMEOWNER: C(.r 2 J C C A cK, PHONE: C�`�� / CONTRACTOR ADDRESS: 3. 72 ELECTRICIAN: l S4 PLUMBER: MIA. HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY /STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REM ODEURENOVATION* SWIMMING POOL Required) X , DESCRIPTION OF WORK: w o R dC) a lead STRUCTURE USE: L)QmO yO` 4 4 p 6.aw' t ry4 em o` c41 P 5 etr`Vic,t -Td S 0cfe per Q. MCltir J er < 6 < 0j HOMEOWNER ASSOCIATION /ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILI TANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: HEATED AREA: (Cost offabor and Materials) PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE NUMBER OF BEDROOM$' NUMBER OF BATHROOI\s INTERIOR WALL TYPE: Plans Examiner Zoning Official � r ZoAtµ k tss d E S FROM : AUST =NVIRONMENTAL INC FAX NO. : 979731 5 Mar. 10 2003 07:45PM P2 PLM REPORT Steve MoodyMicrn Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH I.icenso No, 30 -0094 Carrollton, Texas 75006 (972) 446 -9482 PAT ID # 102577 Client: Austin Environmental, Inc. Lab Job No.: x3B -01644 Project : Clarke Wyndham, Former Neodyme, 903 Harvey Road Report Date: 03110/2003 Project A : AE0354 Sample Date; 03/0712003 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 600 / R -93 / 116 Page 2 of 3 On 03/10/2003, twenty -f.(24) bulk material samples were submitted by Paul Dohltngor of Auslm FmvimomamA Inc. for asbestos imalysia by PLM/DS, Copies of the lab data shoots are aaae:bed, additional information may be found therein. The rmhs an summmimd below: Sample Number Client Sample Description / Location Asbestos Content ND-05A Drywall Texture, outside Room 7, by Door None Detected - Drywall Material None Detected - Texture ND -05B Drywall Texture, Mezzanine, Southwest End by Stairs None Detected - Drywall Material None Delcuted - Texture ND-05C Drywall Texture, Mezzanine, above Center Stairway None Detected - Drywall Material None Detected - Joint Compound None Detected - Texture ND-06A Cove Base & Mastic, Room 7, Right Side of Door Jamb None Detected - Covc Base None Detected - Cream Mastic ND -06B Cove Base & Mastic, Room 11, by Door Iamb None Detected - Cove Base None Detected - Cream Mastic ND -06C Cove Base & Mastic, Break Room None Detected - Cove Base None Detected - Cream Mastic ND -07A Popcorn Ceiling Texture, Women's Restroom, above Hot Tub Norte Detected - Ceiling Texture ND-07B Popcorn Ceiling Texture, Women's Restroom, above Hot Tub None Detected - Drywall Material None Detected - Ceiling Texture ND -07C Popcorn Ceiling Texture, Men's Restroom, Middle of Ceiling None Detected - Drywall Material None Detected - Ceiling Texture ND -08A Blue Drywall Texture, Hallway to Women's Restrooms None Detected - Drywall Material None Detected - Texture ND408R Blue Drywall Texture, Lobby, East Wall by Middle Column None Detected - Drywall Material None Detected - Texture Analyst .., .. Enrico '.. ^... " " I& Lab Director: Steve Moody Approved Signatory: _._...., ... Thank you for chnncmg Steve Moody Micto Services . . FROM : AUS ENVIRONMENTAL INC FAX NO. : 97973 5 Mar. 10 2003 07:46PM P1 PLM REPORT Steve Moody Micro Services, Inc. NV1.AP Lab No, 102056 1510 Randolph, Suite 602 TDH License No. 30.0084 Carrollton, Texas 75006 (972) 446 -9482 PAT Ill It 102577 Client : Austin Environmental, Inc. Lab Job No.: x38 -01644 Project : Clarke Wyndham, Former Neodyme, 903 Harvey Road Report Date: 03/10!2003 Project # : AE03 -54 Sample Date: 03/07/2003 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM /DS) EPA Method 600 / R -93 / 116 Page 3 of 3 On 03/10!2003, mvrayfour (24) bulk material samples were submitted by Paul Dahlinger of Austin L•avimumental, 1ne. for admMos analysis by PLMDS. Copies of the lab data sheets are attached; addi kwit! infamradon may be found therein. The results are surmaarized below: Sample Number Client Sample Description / Location Asbestos Content ND -08C Blue Drywall Texture, Lobby, by Men's Restroom, Hallway None Detected - Drywall Material None !Detected - Ceiling Texture These samples wart analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated vista! caimm. Results may not be reproduced acept in full. This tot sport mlates only to t11e samples toted Theme um results do not imply mdoracrnent by N VLAP or arty agwcy of the U.S. Goverment Acercdacd by Ilk: National Voluntary Laburwkwy Accrurlitation Program for Balk Asb:stos ribLr Analybis under lab Cade 102056. NWlr =J Analyst; Roy Enrico Lab Director: Steve Moody Appmecd Signatory .-... - Tbcnk you for cboosiaa Sww Moody Mx— 5—iccs -- APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 C OLLEt ;t -!itAHON (979) 764 -3570 (979) 764 -3496 FAX WWW.CSTX.GOV ADDRESS /LOCATION: / Z)3 6w se Only DATE: cc APPLICATION # TEMP POLE # LOT BLOCK SUBDIVISION d SEC /PH BUSINESS /OWNER NAME: HONE: 0 3 e / 1 > �ow CONTRACTOR /HOMEOWNER: C 4 C PHONE: .r /• 2/ CONTRACTOR ADDRESS: 3 60O 2 � 4 % ` l0 � �rI"tN T 7 2 ELECTRICIAN: c PLUMBER: HVAC: N AN GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY /STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ' SLAB ONLY DUPLEX (Landscape Plans REMODEL /RENOVATION" SWIMMING POOL Required) DESCRIPTION OF WORK: — 1 K 66 a %VCITT STRUCTURE USE: Q (w O y0 at n , rv4 e r 1 ot 6WIcP 1JU�- «�Ce•1) Remove- HOMEOWNER ASSOCIATION /ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITYf TANDARD (�) PROJECT REGISTRATION# EABPRJ VALUATION: $ l �^ TOTAL AREA: HEATED AREA: (Cost oftabor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑ SEWER TAP: WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE INTERIOR WALL TYPE: 51ZE SIZE SIZE SINGLE ATTACHED I EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE DETACHED .n TRIPLE CARPORT SIGNATURE OF APPLICANT: "If proposed work involves new com rcia construction or facade improvements /renovations to an existing commercial property, building elevations are required. Official Use Only Comments: YES or NO Plans Examiner Zoning Official Project Room 110V 30A To Existing Outlets To This Room Project Room 110V 30A To Existing Outlets To This Room Supply Room 110V 30A To Existing Outlets To This Room Up • Project Project Room Room 110V 30A To 110V 30A To Existing Outlets To Existing Outlets To This Room I This Room Racked Pallet Storage Open Fabrication Area • e 110V 30A To Existing Outlets Below Mezzanine ne 110V 30A To Existing Outlets On Mezzanine r � c-) �Ar Project Room 110V 30A To Existing Outlets To This Room EXHIBIT 1C: BUILDING 903 ELECTRICAL MODIFICATIONS u-. b e4 — �QOVKAA i �vo 220V 30A 1 1 Out4 r 25 110V 30A To Add 4 Outlets Distributed Racket Ball Court d 01 f 0 d e� a . d Y V 220V 60A 3 1 Outl m Wood Shop ADD 200A REMOVE 3 PARK SPACES IN FRC OF DOOR AND M AS LOADING ZC NORTNWESTWALL ADD: 8 FT ROLL -UP STEEL DOOR 24 EXHIBIT 1B: BUILDING 803 MODIFICATIONS M fKDL,.VT-=oN UNIFIED DEVELOPMENT ORDINANCE FACT SHEET C-1 General Commercial This district is designed to provide locations for general commercial purposes, that is, retail sales and service uses that function to serve the entire community and its visitors. Permitted• • Extended Care Facility / Convalescent / Nursing Home • Educational Facility, Indoor Instruction • Educational Facility, Outdoor Instruction • Educational Facility, Primary & Secondary • Educational Facility, Tutoring • Educational Facility, Vocational / Trade • Government Facilities • Health Care, Hospital • Health Care, Medical Clinic • Parks • Places of Worship • Animal Care Facility - Indoor • Art Studio / Gallery • Conference / Convention Center • Country Club • Day Care, Commercial • Drive -in / thru Window • Dry Cleaners and Laundry • Fraternal Lodge • Funeral Homes • Health Club / Sports Facility, Indoor • Health Club / Sports Facility, Outdoor • Hotels • Offices • Parking as a Primary Use • Personal Service Shop • Printing / Copy Shop • Radio / TV station / studios • Restaurants • Retail Sales - Single Tenant over 50,000 SF • Shooting Range, Indoor • Theater • Storage, Self Service • Wireless Telecommunication Facilities - Unregulated Permitted with Specific Use Standards: • Fuel Sales • Golf Course or Driving Range • Car Wash • Commercial Garden /Greenhouse /Landscape Maintenance • Commercial Amusements • Retail Sales and Service • Sexually Oriented Business • Vehicular Sales, Rental, Repair and Service UNIFIED DEVELOPMENT ORDINANCE FACT SHEET R &D Research & Development This district is designed for administrative and professional offices, and research and development oriented light industrial uses meeting the standards and performance criteria established in this section. These uses could be compatible with low intensity uses and all residential uses, thereby maintaining the character and integrity of neighborhoods. This district should be carefully located in areas where there is sufficient access to arterial level thoroughfares. The following supplemental standards shall apply to this district: 1. Performance Criteria for All Uses a. Impervious Surface: Impervious surface is limited to 70 percent. b. Floor Area Ratio (FAR): The maximum FAR in this district shall not exceed 50 percent. C. Building Materials: All main buildings shall have not less than 90 percent of the total exterior walls, excluding doors, windows and window walls, constructed or faced with brick, stone, masonry, stucco or precast concrete panels. d. Signs: Any detached or freestanding signage shall meet the criteria for low- profile signs established in Section 7.4, Signs. Materials shall match building facade materials. e. Other District Regulations:' Uses should be designed to provide adequate access and internal circulation such that travel through residentially -zoned or developed areas is precluded. All processes are to be conducted inside buildings and there shall be no outside storage or business activity. Any business operations occurring during the hours between 7 p.m. and 6 a.m. must meet all the performance criteria established in this section, as well as limit vehicular access into the site through a designated access point that mitigates any adverse impacts of the traffic on surrounding residential areas. 2. .Additional Standards a. This section may be applied to any conditional use proposed in this district when either the Administrator or Development Engineer believe that the existing performance standards contained in this UDO are insufficient to address the proposed use because of its technology or processes and thus, will not effectively protect adjacent existing or future land uses. One or both shall so advise the Planning and Zoning Commission in writing. In such cases, the Planning and Zoning Commission shall hold a hearing to determine whether a professional investigation or analysis should be performed to identify and establish additional reasonable standards. If so determined, based on the information presented at the hearing, the Planning and Zoning Commission will identify the areas to be investigated and analyzed and will direct the staff to conduct the appropriate research necessary to develop standards for successful management of the new project. Any and all costs incurred by the City to develop additional standards shall be charged to the applicant and included as an addition to the cost of either the building permit fee or zoning application fee. UNIFIED DEVELOPMENT ORDINANCE FACT SHEET M -1 Light Industrial This district is provided for offices, research and development activities and high technological, light manufacturing, non - polluting industries that are self- contained. It is further intended that the Light Industrial District may be compatible with adjacent uses in any other district, depending upon the character of the operation and the conditions imposed. Permitted Uses• • Educational Facility, Vocational / Trade • Government Facilities • Parks • Places of Worship • Offices • Radio / TV Station / studios • Wholesales / Service • Industrial, Light • Scientific Testing / Research Laboratory • Storage, Outdoor - Equipment or Materials • Warehousing / Distribution • Wireless Telecommunication Facilities — Unregulated Permitted with Specific Use Standards: • Sexually Oriented Business • Utility • Wireless Telecommunication Facilities— Intermediate Permitted with a Conditional Use Permit: • Wireless Telecommunication Facilities —Major UNIFIED DEVELOPMENT ORDINANCE FACT SHEET C -2 Commercial - Industrial This district is designed to provide a location for outlets offering good and services to a limited segment of the general public. The uses included primarily serve other commercial and industrial enterprises. Permitted Uses• • Extended Care Facility / Convalescent / Nursing Home • Educational Facility, Indoor Instruction • Educational Facility, Outdoor Instruction • Educational Facility, Primary & Secondary • Educational Facility, Tutoring • Educational Facility, Vocational / Trade • Government Facilities • Health Care, Hospital • Health Care, Medical Clinic • Parks • Places of Worship • Animal Care Facility - Indoor • Animal Care Facility - Outdoor • Conference / Convention Center • Country Club • Dry Cleaners and Laundry • Fraternal Lodge • Funeral Homes • Offices • Parking as a Primary Use • Printing / Copy Shop • Radio / TV station / studios • Shooting Range, Indoor • Storage, Self Service • Bulk Storage Tanks / Cold Storage Plant • Industrial, Light • Scientific Testing / Research Laboratory • Storage, Outdoor - Equipment or Materials • Warehousing / Distribution • Wireless Telecommunication Facilities - Unregulated Permitted with Specific Use Standards: • Commercial Garden /Greenhouse /Landscape Maintenance • Commercial Amusements • Golf Course or Driving Range • Retail Sales and Service • Sexually Oriented Business • Wholesales / Services • Vehicle Sales, Rental, Repair and Service • Recycling Facility -Large • Utility • Wireless Telecommunication Facilities - Intermediate PROJECT PLAN REVIEW NO BUSINESS OCCUPANCY REQUIREMENTS 2000 International Building Code CODE SECTION ITEM O.K., COMMENT OR N/A 1004.3.2.5 Exit Access Corridor Continuity 1004.2.3.1 Multiple Tenants 1003.3.4 1005.3.2.5 Smokeproof Enclosures 1004.3.3 Balconies 1003.2.2.8 Mezzanines OV 1005.3.2 Enclosed Stairs Exit Illumination and Signs 707.2(7) Floor Opening Permitted Stairway Floor Number Signs 1005.3.6 EXTERIOR EXITWAY STAIRS N/A 1005.3.6.1 Height • 6 Stories • 75 it 1004.2.4.2 Balcony Travel Distance Increase 1005.3.6.5 Fire Resistive Separation 1006.2.2 Adjacent Lot Lines 1003.3.3.5 STAIRWAY CONSTRUCTION N/A 1003.3.3.5 Stairway Construction 1003.3.3.3.2 Closed /Open Risers 1005.3.2.2 Separation of Closets Below Stairways 1005.3.2.3 Stairway Identification for Stairs That Continue Below the Level of Discharge 1003.3.3.3 Stair Treads and Risers 1003.3.3.3.1 Uniform Treads and Risers 1003.3.3.7 Circular Stairs 1003.3.3.4 Landings 1003.3.3.11 Handrails 1003.3.3.2 Headroom 1003.3.3.12 Access to Roof 1005.3.5 Horizontal Exits 1006 Exit Discharge 1003.3.1.3.4 Access - Controlled Egress Doors CODE SECTION ITEM O.K., COMMENT OR NIA 1003.3.1.3.5 Security Grilles 1003.3.1.8 Latching and Locking Hardware 1003.3.4 Ramps N 1004.3.3 Balconies 1003.2.12 Guards 1003.2.10 Exit Illumination and Signs ► /OT 1005.3.2.4 Stairway Floor Number Signs N/A 2000 Plan Review Forms Page 29 of 60 PROJECT PLAN REVIEW NO BUSINESS OCCUPANCY REQUIREMENTS 2000 International Building Code INTERIOR FINISH INTERIOR FINISH SECTION 803A UNSPRINKLERED SPRINKLERED REQUIRED ACTUAL O.K., REQUIRED ACTUAL O.K., COMMENT COMMENT OR NIA OR NIA Vertical Exits and Exit A B Passageways '•' Exit Access Corridors B C and Other Exitways Rooms and Enclosed C C Spaces Floor Covering 0.22 watt/ 0.22 watt/ Corridors & Exits sq cm. sq cm. a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section 803.3.1. b. In vertical exits of buildings less than three stories in height of other than Group 1 -3, Class B interior finish for unsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted. C. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire - resistance rating is required for structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure. d. Applies when the vertical exits, exit passageways, exit access corridors or exitways, or rooms and spaces are protected by a sprinkler system installed in accordance with Section 903.3.1.1 or Section 903.3.1.2. 2000 Plan Review Forms Page 30 of 60 W City of College Station Page of Aftl Building Inspection Department ` 14 PLANS EXAMINATION REPORT Address: Date: /0z it /(,)S— Project Name: /a. � el Drawing Number Code Ref. Number Questions or Comments r 'kq - t* , "— iF e -4 3. 2- 0 0 4 ;% Y - ----------- Y Received by: — Date: