HomeMy WebLinkAboutCorrespondencer �
TEXCON o5-iq2
TRANSMITTAL 161-31)6s-
Date: October 31, 2005
To: Jennifer Reeves
Development Services
City of College Station
From: Joe Schultz, P.E.
Texcon General Contractors
1707 Graham Road
College Station, Texas 77845
Phone: (979) 764 -7743
Subiect: Revised Final Plat ��
Williams Creek Subd ision — Phase 3
College Station, Texas
Remarks: Attached are 2 full -sized copies and 12 -11x17 copies of the revised Final Plat
for Williams Creek Phase 3. Parkland Dedication fees and the signed mylar
original of the plat will be submitted at a later date. Also attached is our
response to Staff Review Comments No. 1, dated October 24, 2005.
Please let me know if you need anything else or have any questions.
Response to Comments
Staff Review Comments No. 1
(dated October 24, 2005)
• Note #17 has been added to the plat stating that fill material has been placed on some
of the lots and the foundation for the structure to be constructed on each of these lots
should be designed accordingly.
• Lot and Block information has been added to the title block of the plat, as requested.
• The lots in Phase 3 do not need a minimum finished floor elevation for the sewer,
because the Sewer Master Plan shows the sewer lines and services in the rear of the
lots where necessary for gravity flow.
• Phase 4 has been constructed, so Williams Creek Subdivision has 2 access points.
(Lanham Drive was constructed with Phase 4).
• The 20' PUE along the inside of Johnson Creek Loop has been changed to a 15' PUE
so that the retaining wall in this area could be placed closer to the street.
• The slope easement widths have been reduced since the street ditch design back
slopes can be steeper than 4H:1 V slopes outside of the street right -of -way, thereby
reducing the area needed for the back slopes.