Exhibit D WaterCAD Analysis Summary Pipe Analysis - Fire Flow - Fire Hydrant 2 & 3 Pipe Number Length (ft) Start Node End Node Size (in) Pipe Material Hazen - William C- Value Pipe Flow (GPM) Velocity (ft /s) P -1 250 J -1 FH1 12 PVC 150 2,750 7.8 P -2 139 FH1 J -3 12 PVC 150 2,750 7.8 P -3 504 J-3 J -4 12 PVC 150 2,700 7.66 P -4 14 J -4 FH2 12 PVC 150 2,650 7.52 P -5 427 FH2 J -6 12 PVC 150 1,400 3.97 P -6 186 J -6 FH3 12 PVC 150 1,350 3.83 P -7 357 FH3 J -8 12 PVC 150 100 0.28 P -8 299 J -8 J -9 12 PVC 150 50 0.14 P -9 13 1 -9 J -10 12 PVC 150 50 0.14 P -10 612 J -11 J -1 8 PVC 150 0 0 P -12 61 J -12 J -3 8 PVC 150 -50 0.32 P -13 61 J -13 J -4 8 PVC 150 -50 0.32 P -14 66 J -14 J -6 8 PVC 150 -50 0.32 P -15 78 J -15 J -8 8 PVC 150 -50 0.32 P -RES 20 R -1 I J -1 12 PVC 150 2,750 7.8 Exhibit D WaterCAD Analysis Summary Junction Analysis - Fire Flow Analysis - FH 2 & FH 3 Junction Elevation (ft) (GPM Pressure (PSI) J -1 317.05 0 80.5 FH1 314.73 0 80.1 J-3 312.56 0 80.3 J -4 311.27 0 78.2 FH2 311.32 1,250 78.1 J -6 314.26 0 76.2 FH3 311.87 1,250 76.9 J -8 308.48 0 78.4 J -9 303.41 0 80.6 J -10 303.41 50 80.6 J -11 306 0 85.3 J -12 313.38 50 79.9 J -13 311.93 50 77.9 J -14 314.41 50 76.1 J -15 307.86 50 78.6 Exhibit D WaterCAD Analysis Summary Pipe Analysis - Fire Flow - Fire Hydrant 1 & 3 Pipe Number Length (ft) Start Node End Node Size (in) Pipe Material Hazen - William C- Value Pipe Flow (GPM) Velocity (ft /s) P -1 250 J -1 FH1 12 PVC 150 2,750 7.8 P -2 139 FH1 J -3 12 PVC 150 1,500 4.26 P -3 504 J-3 J -4 12 PVC 150 1,450 4.11 P -4 14 J -4 FH2 12 PVC 150 1,400 3.97 P -5 427 FH2 J -6 12 PVC 150 1,400 3.97 P -6 186 J -6 FH3 12 PVC 150 1,350 3.83 P -7 357 FH3 J -8 12 PVC 150 100 0.28 P -8 299 J -8 J -9 12 PVC 150 50 0.14 P -9 13 J -9 J -10 12 PVC 150 50 0.14 P -10 612 J -11 J -1 8 PVC 150 0 0 P -12 61 J -12 J -3 8 PVC 150 -50 0.32 P -13 61 J -13 J -4 8 PVC 150 -50 0.32 P -14 66 J -14 J -6 8 PVC 150 -50 0.32 P -15 78 J -15 J-8 8 PVC 150 -50 0.32 P -RES 20 R -1 J -1 12 PVC 1 150 1 2,750 7.8 Exhibit D WaterCAD Analysis Summary Junction Analysis - Fire Flow Analysis - FH 1 & FH 3 Junction Elevation (ft) Demand (GPM) Pressure (PSI) J -1 317.05 0 80.5 FH1 314.73 1,250 80.1 J-3 312.56 0 80.8 J -4 311.27 0 80.5 FH2 311.32 0 80.5 J -6 314.26 0 78.5 FH3 311.87 1,250 79.3 J -8 308.48 0 80.8 J -9 303.41 0 83 J -10 303.41 50 83 J -11 306 0 85.3 J -12 313.38 50 80.5 J -13 311.93 50 80.2 J -14 314.41 50 78.5 J -15 1 307.86 1 50 1 81