Loading...
HomeMy WebLinkAboutApplicationFOR OFFICE USE P &Z CASE NO.: I H/1 DATE SUBMITTED: PRELIMINARY PLAT APPLICATION The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: Filing Fee of $400.00. - C- � k Variance Request to Subdivision Regulatio 100 (if applica le) - tpYe_Ji0V11 S, b Ae� 1 `yq" / Application completed in full. JJ V Thirteen (13) folded copies of plat. (A revise original must be submitted after staff review.) One (1) copy of the approved Master Plan if applicable. A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Rezoning Application if zone change is proposed. Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of aooroval (if applicable). Date of Preapplication Conference: NAME OF SUBDIVISION a tL LX oSe_,A tno� ���'�11�1 I� [1y SPECIFIED LOCATION OF PROPOSED SUBDIVISION � jr _f: af ( a stn ROCIA APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Street i State Phone Number (I i-1 ) (m Fax Number O :Lq) O'S Z14 PROPERTY OWNER'S INFORMATION &L owners must be identified. Please attach an additional sheet for multiple owners : Name A r- Street Address "5205 Ea."k City State _ _X Zip Code '1 1 %43 - E -Mai Address — Phone Number 0 1�) 61 (a(Aq Fax Number / `_17q (AS ARCHITECT OR ENGINEER'S INFORMATION: Name co' - J0 e S C' tyo. � k , '? . L Street Address 00'1 �a_.q % .ayy �90..d City C01 r jf�' 'O - V) State _ 77 k Zip Code Tltk'�— E -Mail Address _4(> 5cl, g'L +e*z0 V1 , VA C Phone Number 1 -� Fax Number (a I�) _70 -- 7 - 7 ( ' I nW Total Acres Of Subdivision 10-7, W— Number Of Lots By Zoning District � & " o /9' 1 Average Acreage Of Each Residential Lot By Zoning District: 0.1fo �- Floodplain Acreage Parkland dedication by acreage or fee? See d I NY ` zel -e od plcu n A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable) Requested variances to subdivision regulations & reason for same 6-toc k.. 0'VIA4 Va,i1,l1 1C P r _O ST Requested oversize participation �U" . 012 � Parkland Dedication due prior to filing the Final Plat: ACREAGE: # of Acres to be dedicated # of acres in floodplain # of acres in detention # of acres in greenways OR FEE IN LIEU OF LAND: A0 # of Single - Family Dwelling Units X $556 = $ , 74� D I 14 2 (date) Approved by Parks & Recreation Board - 7 12.o 2-WL - The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that all respective owners have been identified aa on this aWationl R -O -W Acreage I � 4; ,. Total # Of Lots M re itle Date SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site /waterway alterations: A LL I i h fir S1 [ �e— Cnr� 5 -u L�'► rr-� ACKNOWLEDGMENTS: I, TOVV4 JongS � J oe. ' _X 'tvtj L t , design engineer /owner, hereby acknowledge or affirm that: The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a nditi of approval of this permit application, I agree to construct the improvements proposed in this application ac in o th se documents and the requirements of Chapt r 13 of the C eg S a 'on City Code. Prope wne 1neeX CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A. 1, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer C. I, `10SeO h JC�h kkA T1- not diminish the flood - carrying capacity of the wy or development are consistent with requirem4 encroach nts of flood ys d fl odway frirf Engineer t r th 16samm 0it)8NLJZPfeg 65889 Y� a ry f 1 t- I�d✓��' D. I, , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Conditions or comments as part of approval: Date In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. or development covered by this permit shall g this permitted site and that such alterations Station City Code, Chapter 13 concerning 9 , to.- ©-5 6/13/03 A "I ( * h rq" CITY Y OF COIAT(I SFAl ION I'btInin.Q u I)e-I rnevar Sne• rrs SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) © 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. [� 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. D' Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) [Q Date of preparation. Engineer's scale in feet. Total area intended to be developed. Q 4. North Arrow. �✓ 5. Subdivision boundary indicated by heavy lines. �-�\, 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. [�f 7. All applicable certifications based on the type of final plat. [� ✓Ownership and Dedication [ \/S rveyor and /or Engineer .City Engineer ( tty Planner, anning and Zoning Commission (delete if minor plat) X [� Brazos County Clerk Ce [.� 8. Paid tax certificates. 9. If submitting a replat where there are existing improvements, submit a survey of the subject tJw property showing the improvements to ensure that no encroachments will be created. 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 0 43 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. [a' 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. 13. Matches the approved preliminary plat and /or master t plan. 613103 4 M ❑ 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed [l F Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. Q [� Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and /or intersection angles meet ordinance. Alleys. 0 Q Easements. [fi \ A number or letter to identify each lot or site and each block. []' Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) Q 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: a Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and /or sidewalk layout of the subdivision. (may be combined with other utilities). a Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size /depth to meet the utility master plan and any future growth areas.) [� Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. B Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. 4�j Drainage Report. P1 Erosion Control Plan (must be included in construction plans). f�j 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. [� 17. Are there impact fees associated with this development? Q"Yes ❑ No Impact fees for R -1, R -2, & R -3 zoned final plats, must be paid prior to filing. [� 18. Will any construction occur in TexDOT rights -of -way? ❑ Yes ©'No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 6/13/03 5 of 64-