HomeMy WebLinkAboutMisc.Permit Number
Envelope Compliance Certificate Checked By /Date
2003 IECC
COMcheck - -EZ So$ware Version 3.0 Release la
Data filename: G: \Wallace Halpin \College Station \Documents \College Station.cck
Section 1: Project Information
Project Name:
Designer /Contractor:
Document Author:
COLLEGE STATION RETAIL
COLLEGE STATION, TEXAS
LANE DESIGN GROUP
820 GESSNER, SUITE 1770
HOUSTON TEXAS 77024
BURKE LANE
Section 2: General Information
Building Location (for weather data):
Climate Zone:
Heating Degree Days (base 65 degrees F):
Cooling Degree Days (base 65 degrees F):
Project Type:
Window / Wall Ratio:
College Station, Texas
4b
1788
2776
New Construction
0.19
Building Type Floor Area
Retail Sales, Wholesale Showroom 14000
Section 3: Requirements Checklist
Bldg.
Dept.
Use
Air Leakage, Component Certification, and Vapor Retarder Requirements
[ ] 1. All joints and penetrations are caulked, gasketed, weather - stripped, or otherwise sealed.
[ ] 2. Windows, doors, and skylights certified as meeting leakage requirements.
[ ] 3. Component R- values & U- factors labeled as certified.
[ ] 4. Stair, elevator shall vents, and other dampers integral to the building envelope are equipped
with motorized dampers.
[ ] 5. Cargo doors and loading dock doors are weather sealed.
[ ] 6. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an
appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and
with 3 inches clearance from insulation material.
+. s
Climate- Specific Requirements
omnonent Name /Description
Roof 1: Metal Roof with Thermal Blocks
Exterior Wall 1: Solid Concrete or Masonry <= 8"
Furring: None
Exterior Wall 2: Metal Frame, 16" o.c.
Window 1: Metal Frame:Double Pane
Clear, SHGC 0.70, PF 0.44
Door 1: Glass, Clear, SHGC 0.70
Gross
Cavity
Cont.
Proposed
Budget
Area
R -Value
R -Value
- Factor
-Fact r
8050
24.0
0.0
0.059
0.063
5057
- --
0.0
0.505
0.207
2647
11.0
0.0
0.143
0.207
1394
- --
- --
1.000
1.230
63
- --
- --
1.000
1.230
(a) Budget U- factors are used for software baseline calculations ONLY, and are not code requirements.
Envelope PASSES: Design 17% better than code
Section 4: Compliance Statement
The proposed envelope design represented in this document is consistent with the building plans, specifications and other
calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003
lECC requirements in COMcheck - EZ Version 3.0 Release la and to comply with the mandatory requirements in the
Signature Date