Loading...
HomeMy WebLinkAboutStaff Comments CITY OF COLLEGE STATION `� DEVELOPMENT SERVICES cf 1101 Texas Avenue South, PO Box 9960 COLLEGE STATION College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM May 20, 2003 TO: Henry Mayo, Via fax 690.3378 FROM: Bridgette George, Assistant Development Manager SUBJECT: LORD'S ACRES - Preliminary Plat Staff reviewed the above - mentioned preliminary plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Tuesday, May 27, 2002, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, June 5, 2002, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised preliminary plat; and, One (1) Mylar original of the revised preliminary plat. One (1) copy of the digital file of the preliminary plat on diskette or e-mail to nmanhart @ci.college - station.tx.us Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. If you have any questions or need additional information, please call Carol Cotter or myself at 764 -3570. Attachments: Staff review comments cc: Mrs. Terry Quick, St. Thomas Aquinas Church, Via fax 260.4502 Paul Lodholz, Tackett - Lodholz Architects, Via fax 713.521.0594 Case file #03- 00500111 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 1 Project: LORD'S ACRES - 03- 00500111 ENGINEERING 1. No comments. Reviewed by: Carol Cotter Date: May 16, 2003 ELECTRICAL 1. Developer installs conduit as per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser pole(s). 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design. Pull boxes provided by the city. 5. Developer provides digital AutoCAD 2000i version of plat and /or site plan. Email to rbolin @ci.college - station.tx.us 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines. Reviewed by: Ronnie Bolin Date: 5 -14 -03 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2