(- GENERAL NOTES;
A J EFINITIONS
WALL CONTRACTOR - CHADWICK'S RETAINING WALLS
GENERAL CONTRACTOR - GENERAL CONTRACTOR FOR PROJECT
ENGINEER - COMPREHENSIVE ENGINEERING SOLUTIONS, INC. (CES)
B. GENLRAL
ALL CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE
INTERNATIONAL BUILDING CODE AND ALL CITY OF COLLEGE STATION BUILDING REGULATIONS.
THE CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS, DIMENSIONS AND ELEVATIONS PRIOR TO
EXECUTING ANY WORK.
THE CONTRACTOR SHALL RESOLVE ANY CONFLICTS WITH THE ENGINEER BEFORE PROCEEDING WITH
CONSTRUCTION.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY UNUSUAL OR UNFORESEEN CONDITION OR
SITUATION WHICH AFFECTS THE STRUCTURAL STABILITY OR SAFETY OF THE WALL.
TYPICAL DETAILS. DETAILS NOTED AS TYPICAL AND GENERAL NOTES APPLY TO ALL PARTS OF THE JOB
EXCEPT WHERE SPECIFICALLY DETAILED OR NOTED OTHERWISE,
IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THIS
DRAWING.
THIS STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENT PARTS ARE IN PLACE.
THEREFORE, THE CONTRACTOR SHALL PROVIDE ALL SHORING AND BRACING NECESSARY TO INSURE THE
STABILITY OF ANY AND ALL PARTS DURING THE CONSTRUCTION.
ALL CONTRACTORS PERFORMING WORK ON OR RELATED TO THESE PLANS SHALL CONDUCT THEIR
OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THAT THE PUBLIC IS
PROTECTED. ALL CONTRACTORS SHALL COMPLY WITH THE 'OCCUPATIONAL SAFETY AND HEALTH
REGULATIONS" OF THE U.S. DEPARTMENT OF LABOR, AND WITH THE STATE OF TEXAS REGULATIONS.
THE ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS AND SUBCONTRACTORS
COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS ", SUBJECT TO MORE
STRINGENT REQUIREMENTS IN CONTRACT, DOCUMENTS, AND SPECIFICATIONS FOR THE GENERAL PROJECT.
IN THE EVENT THAT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THESE
DRAWINGS OR CALLED FOR IN THE GENERAL NOTES, THEIR CONSTRUCTION SHALL BE OF THE SAME
CHARACTER AS SHOWN FOR SIMILAR CONDITIONS BUT SHALL BE SUBJECT TO ENGINEER'S APPROVAL
ALL DETAILS OF THE EXISTING STRUCTURE AND DIMENSIONS SHALL BE VERIFIED IN FIELD PRIOR TO
CONSTRUCTION. CONSTRUCTION SHALL BE BASED ON DIMENSIONS AND DETAILS VERIFIED IN FIELD.
. NSPECTION
INSPECTION OF SOILS CONDITIONS AND COMPACTION PER SOILS SECTION BELOW. CONTINUOUS OR
PERIODIC INSPECTION AS REQUIRED BY PROJECT SPECIFICATIONS AND CONSTRUCTION DRAWINGS OR CITY
ORDINANCE SHALL BE COORDINATED BY GENERAL CONTRACTOR AND FACILITATED BY THE WALL
CONTRACTOR FOR THE FOLLOWING WORK AS IT PERTAINS TO THE RETAINING WALLS:
1. PLACING OF ALL ST CTURAL MORTAR WITH 28 -DAY COMPRESSIVE STRENGTH OF 1800 PSI OR
GREATER. :2.43/05
��••�+•++t 1 _ scow N s Im Dorr 1 00041 Smet 1 of 6
. F. T�fif Project raa 04--.1 66 Duo o 9� KBA
* ' / f Filr Nome: WALLdwg Orewrl BY; KQA
'•' �: r HAMPTON INN & SUITES
KRI flNfw 6. NIC)RE1MS ; COLLEGE STATION. TEXAS
1 80993 :�Q^
io''"� 15 5-'t STONE RETAINING WALLS Comprehensive Engineering Solutions, Inc.
I �f�si o i Zt -' GENERAL NOTES 319 South First Strout, Suite A Temple. Texas 76504
t t +�����` - — Voice: (254) 742— 2050 Fax: (254) 742 -2055
V \ h evy. vim LC-3
Feb 14 05 10:34a CES 254- 742 -2055 p.3
�( 2, THE PORTIONS OF MASONRY CONSTRUCTION NOTED ON THE DRAWINGS. y ,"
APPROVAL BY INSPECTOR DOES NOT MEAN APPROVAL OF CONTRACTOR'S FAILURE TO COMPLY WITH THE
PLANS OR SPECIFICATIONS. ANY DETAIL WHICH FAILS TO BE CLEAR OR IS AMBIGUOUS MUST REFERRED
TO THE ENGINEER FOR INTERPRETATION OR CLARIFICATION.
ALL OTHER TESTS SHALL BE DONE IN CONFORMANCE WITH APPLICABLE BUILDING CODE.
D. SOILS & FOUNDAT1Oy.S
ALL RETAINING WALL FOOTINGS SHALL BE CARRIED TO A MINIMUM OF 24" BELOW LOWEST ADJACENT
GRADE, AND SHALL BE FOUNDED ON FIRM BEARING. NATURAL SOILS. OR ON APPROVED COMPACTED
FILL. FOOTINGS MAY OR MAY NOT BE REQUIRED (REFER TO TYPICAL SECTIONS).
FOOTINGS MAY BE POURED NEAT PROVIDED THAT THE SIDES OF THE EXCAVATION WILL NOT SLOUGH IN
AND 2" ARE ADDED TO FOOTING WIDTH.
BOTTOM OF FOOTINGS SHALL BE SLOPED.
ALL FOOTINGS SHALL BE CENTERED UNDER THE SUPPORTED WALL PER DETAILS.
ALL EXCAVATIONS SHALL BE FREE OF WATER AND DEBRIS PRIOR TO POURING FOUNDATION CONCRETE.
BEFORE BACKFILLING REMOVE ALL FORMS AND DEBRIS. ALL BACKFILL SOIL SHALL BE FREE OF ROCKS
AND DEBRIS.
ALL BACKFILL SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE SOILS REPORT.
E. CONCRETE
PORTIAtJI CEMENT; SHALL CONFORM TO ASTM C -150, TYPE I OR TYPE 11.
AGGREGATE; NATURAL SAND, GRAVEL AND CRUSHED STONE AGGREGATE SHALL CONFORM TO ASTM C -33
IF REQUIRED BY SPECS.
MAXIMUM WATER /CEMENT RATIO .55.
ALL CONCRETE SHALL BE SUPPLIED BY AN APPROVED READY MIX PLANT. ALL CONCRETE MIXES SHALL
BE DESIGNED BY AN APPROVED LABORATORY. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR
APPROVAL PRIOR TO START OF CONSTRUCTION IF REQUIRED BY SPECS,
CONCRETE SHALL 28 -DAY MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 3000 PSI WHEN
PROPORTIONED PER METHOD I OF THE APPLICABLE CODE.
MAXIMUM CONCRETE SLUMP SHALL BE 4 ".
ALL CONCRETE SHALL BE VIBRATED.
ALL CONSTRUCTION DETAILS SHALL BE IN STRICT CONFORMANCE WITH THE LATEST EDITION OF THE ACI
CODE.
CONCRETE FOOTINGS SHALL CURE FOR 3 DAYS BEFORE CONSTRUCTION OF CORE OF WALLS IS
STARTED.
ALL REINFORCING STEEL. DOWELS, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE FIRMLY SECURED IN
PROPER POSITION PRIOR TO PLACING CONCRETE.
SEE ARCHITECTURAL /CIVIL DRAWINGS FOR LOCATION AND EXTENT OF EXTERIOR WALKS AND PAVEMENT.
2 I3 °S. ............ scale: NTS pm caul sn..R 2 01 6
.. T l � � � l� 0 4 - 1
r3 o s �. NOm �
e: WALL.dwy - •^ KBA
/ HAMPTON INN S, SUITES
'r KRISf N E B ANDREWS COLLEGE STATION, TEXAS
9 =. 80993
i , � F •- .,! ;: `�`"� STONE RETAINING WALLS
Comprehensive Engineering
South First Street. Suit* olutions Inc.
.,`�--'c, S A em le, rexoa 26504
rr + ►ii aN;� . � �' � GENERAL NOTES P
Voice: (254) 742 -2050 Fax: (254) 742 -2055
Feb 14 05 10:34a CES 254 - 742 -2055 p.4
ALL CONCRETE WORK SHALL BE TESTED AND INSPECTED IN CONFORMANCE WITH THE APPLICABLE BUILDING
`` CODE FOR 3000 PSI CONCRETE BY A LABORATORY OR TESTING AGENCY. TEST AND INSPECTION REPORTS
SHALL BE SUBMITTED TO THE ENGINEER, CONTRACTOR AND BUILDING DEPARTMENT.
ALL CEMENT AND REINFORCING STEEL SHALL BE FROM TESTED STOCK. ALL REINFORCING NO. 4 AND LARGER
SHALL BE GRADE 60.
CONCRETE THAT DOES NOT REACH THE SPECIFIED 28 DAY WORKING STRESSES BASED ON ABOVE TESTS SHALL
BE RETESTED PER IBC. IF THE REQUIRED ADDITIONAL TESTS FAIL TO REACH THE SPECIFIED COMPRESSIVE
STRENGTH, THE STRUCTURE SHALL BE REEVALUATED BY THE ENGINEER FOR THE LOWER STRENGTH CONCRETE
AND, IF IT FAILS TO MEET THE REQUIRED STRUCTURAL STANDARDS. THE CONCRETE SHALL BE REMOVED.
ALL THE REMEDIAL WORK, INCLUDING ANY DESIGN WORK BY THE ENGINEER AND ANY RE- TESTING, SHALL BE
PAID FOR BY THE WALL CONTRACTOR.
F. STONE MASONRY WALL
WALL MATERIALS FOR CORE AND FACE TO BE VERIFIED AND PROVIDED BY CONTRACTOR. APPEARANCE OF FACE
STONE PER OWNER.
BATTER INDICATED ON DETAILS MAY VARY BY 1". REAR OF WALL MAY MATCH FRONT BATTER.
6 -INCH DRAINS SHALL BE PROVIDED BEHIND WALL AS SHOWN IN DETAIL. PVC PIPE SHALL DRAIN INTO STORM
DRAIN SYSTEM.
WALL BACKFILL MATERIAL SHALL HAVE A P.I. LESS THAN 15. BACKFILL WITHIN 36" OF THE BACK FACE OF THE
WALL SHALL BE GRAVITY COMPACTED BY EQUIPMENT OR BY HAND, NO VIBRATORY COMPACTION EQUIPMENT
SHALL BE USED WITHIN 36" OF BACK FACE OF WALL.
ALL FINISHED PARKING. WALKING SURFACES AND LANDSCAPING SHALL BE GRADED AND SLOPED TO PROVIDE
POSITIVE DRAINAGE AWAY FROM WALL.
A CHAIN LINK FENCE OR PEDESTRIAN HANDRAIL SHALL BE PROVIDED FOR ANY AREA WHERE THE VERTICAL
DROP IS GREATER THAN 32 INCHES. FENCE OR HAND RAIL SHALL NOT BE TIED TO STRUCTURAL WALL
G. MISCELLANEOUS;
PRIOR TO CONSTRUCTION, CONTRACTOR SHALL VERY AND FIELD LOCATE ALL UTILITIES. UTILITIES SHOWN ON
WALL PLAN AND /OR SECTIONS MAY NOT REPRESENT ALL UNDERGROUND UTILITIES NEAR WALL CONSTRUCTION,
CONTRACTOR SHALL IMPLEMENT PROPER SHORING TO PROTECT THE INTEGRITY OF THE EXCAVATION (INCLUDING
BUT NOT LIMITED TO NEARBY UNDERGROUND UTILITIES AND ADJACENT FOUNDATIONS). TRENCH SHORING SHALL
BE DESIGNED BY OTHERS.
ENGINEER ASSUMES THAT ADJACENT BUILDING FOUNDATIONS IMPART NO SURCHARGE LOADING ON WALL.
OWNER TO VERIFY WITH GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION.
OWNER TO CONSULT WITH TRENCH SHORING SPECIALIST PRIOR TO ANY EXCAVATION FOR RETAINING WALL
IF OWNER DOES NOT OBTAIN ADDITIONAL BORINGS PER GEOTECHNICAL REPORT. OWNER TAKES RESPONSIBILITY
FOR VERIFYING THAT SOILS ENCOUNTERED DURING CONSTRUCTION ARE ADEQUATELY REPRESENTED BY BORINGS
AND DESIGN CRITERIA DEVELOPED IN THE GEOTECHNICAL REPORT. PER GEOTECHNICAL REPORT, OWNER SHALL
HAVE EXPERIENCED GEOTECHNICAL PERSONNEL TO OBSERVE CONSTRUCTION OPERATIONS AND DOCUMENT THAT
CONDITIONS ENCOUNTERED DURING CONSTRUCTION CONFORM TO THE ASSUMED GENERALIZATIONS IN THE
CEOTECHNICAL REPORT.
BASE OF FOOTING SHALL BE SITUATED AT LEAST 2 FEET BELOW THE MAXIMUM SCOUR DEPTH OF THE
ADJACENT CREEK ALONG THE "REACH" OF THE CREEK ADJACENT TO THE PROPOSED WALL. FOOTING SHALL
BE FOUNDED AT LEAST 3 FEET INTO THE FOUNDING FORMATION OF GRAY, SHALEY CLAYS ( GEOTECHNICAL
PERSONNEL TO VERIFY
r.. ���� / //� , score: NT$ f Prot Dote::2 13/05 I Sheet 3 or 6 .
.... iV' L/ a` - 01. -1066 Designed KI A • - .. _ +r ) C wAli -41W4 ow KBA
P`k KRISriNE (/ HAMPTON INN $ SUITES
COLLEGE STATION, TEXAS
° 80993 .
F'. = STONE RETAINING WALLS Comprehensive Engineering Solutions, Inc.
r rr - s GENERAL NOTES 319 South First Street. Suite A Temple, Texas 76504
Voice; (254) 742 -2050 Fox: (234) 742 - 2055
Feb 14 05 10:34a CES 254- 742 -2055 p.5
r _= .. 10 STONE FINISH PER ARCH. SPEC.
--------11 WITH TYPE N WALL MORTARED
MORTAR OR
/�\ MIN. 18" PORTLAND MORTAR MIX.
Mi vos......
IMPORTED GRANULAR G
-.
SA ND Y) BA CKFILL 12 + •� 1
1'
OMPA TED 9 5% IN i %i'��' �� c�' �0"
6" LIFTS % 12
t + { \ � MAX
6" PVC DRAIN (200' MAX) - �y, . f WEEP HOLE
%A ' 12" ELEVATION OF WATER IN
NON- -WOVEN GEOTEXTILE '* - CREEK DURING HIGH FLOW
MORTARED
RUBBLE CORE y -.E7,4 � • - \\(/
'" � 3' -0" GRAY SHALEY CLAY
1' -6" ��
% (TO 6 VERIFIED)
' — •
CLEAN. BAGGED GRANULAR FILL
SUCH AS AN ASTM C-33, SIZE 57 5-
3' -6"
- TYPICAL SECTION — STRUCTURAL WALL A 0
NTS
10 MAX.
STONE FINISH PER ARCH. SPEC.
/X\ V/ 1
MIN_ 18" FACE OF WALL TO BE MORTARED
7 WITH TYPE N MORTAR OR
PORTLAND MORTAR MIX.
Prrr,21.- Ill
IMPORTED GRANULAR
//' ,
(SANDY) BACKFILL 12 + :� 1
COMPACTED 957. IN � % 12
6" LIFTS
-r -' 9 " WEEP HOLE
6" PVC DRAIN (200' MAX) / TO
5' -O"
_
NON -WOVEN GEOTEXTILE �� � �� .. 2 • ELEVATION OF WATER IN
• '
+ � • CREEK DRAIN HIGH FLOW
6" PVC DRAIN (200' MAX) N A % •
WE EP
:A �'
MORTARED
L
RUBBLE CORE '�"'�E' 1 1, /
y '= % , 3 . -0 "
1'-6" r GRAY SHALEY CLAY
�W` EL 238
. _
CLEAN. BAGGED GRANULAR FILL .--14-1-7--; .`.., . ;-x',;r (70 BE VERIFIED)
SUCH AS AN ASTM C -33. SIZE 57
. • "..z., 11" �� OF �T I � II i
CONCRETE BASE W/ N0.5 0 11" 5' _ *�1Q � --Ar �
i
CONTINUOUS WALL KEY WITH 5 KRISTINE B. ANDREWS
EX
SYNKO -FL WATERSTOP 1' -6" / 1' -1" ,i-o • 84993 a_
(TYP. 0 ALL WALL KEYS) yip:• (41_
TYPICAL SECTION—STRUCTURAL WALL B 0
NTS 4?- 1310
NOTES: Scds: NTS 1PIot Date2 13 05 1 Sheet 4 _ of 6
1. FOR WEEP HOLES AND DRAIN PIPE Project No.: 04 Dsl ed KBA .
INSTALLATION AND SPACING SEE GENERAL Filo Nom WALL.dw9 Drown ac. KBA
NOTES. HAMPTON INN & SUITES
COLLEGE STATION. TEXAS
STONE RETAINING WALLS Comprehensive Engineering Solutions, Inc.
SECTIONS 319 South First Street. Suite A Temple, Texas 76504
Voice_ (254) 742 -2050 Fax; (254) 742 -205
Feb 14 05 10:34a CES 254 - 742 -2055 p.6
"1
10 MAX.
--t STONE FINISH PER ARCH_ SPEC.
/ X`��
f� FACE OF WALL TO BE MORTARED
7 MIN. it3' WITH 'TYPE N MORTAR OR
PORTLAND MORTAR MIX.
% 1
IMPORTED GRANULAR 1 + " 'A
i
(SANDY) BACKFILL j
COMPACTED 95X IN L "-�, MORTARED
6" LIFYS M�:,ll '� % RUBBLE CORE
;`i +� e ,
1 O'+ Cryp �-�J. % 1
ri t �
6" PVC DRAIN (200' MAX) r " � 12 WEEP
HOLE
STRATAGRID 500 _ -..-- •74 r . .
OR EQUIVALENT 4 MAX ) :�',,. i % 1 ■ ELEVATION OF WATER IN
-------- �'�rJ • K �U` N HI L•
12' MAX
1' -6' GRAY SHALEY CLAY
NON - WOVEN GEOTEXYILE - - ��•�- f (TO VIFIED)
-- I fil: * . L ^ WEEP
'`�� ` r_ HOLE
6' PVC DRAIN (200' MAX) ∎ r. ��
_ 3' -0'
CLEAN, BAGGED GRANULAR Flll + , _rt ,`:-
SUCH AS AN ASTM C -33, SIZE 57 "' . . It
•a\
CONCRETE BASE w/ N0.5 0 11* 5.
CONTINUOUS WALL KEY WITH
SYNKO -FLEX wATERSTOP 1' -6" `- / 1' -6"
(TYP. 0 ALL WALL KEYS)
4 -6" /
TYPICAL SECTION—STRUCTURAL WALL C O
NTS
` .....NFy.%t
"P\ OF -411..°10
NOTES: 0 ►
NOTES: ...T• e`' : - * •
/,
1- FOR WEEP HOLES AND DRAIN PIPE
INSTALLATION AND SPACING SEE GENERAL 5 KRISTINE 8- ANDREWS S•
NOTES. i
'.0, 80993 '.
7/4„...4.2?...n,,,,--- 4
ci
soak NTS ] Alot Dot.;2 f 05 rsh..t 5 o f 6
PM' .. N0.: 44— • .. Designed
Rye Nam. WALL.dwg - Drw, or KBA
HAMPTON INN & SUITES
COLLEGE STATION. TEXAS
STONE RETAINING WALLS Comprehensive Engineering Solutions, Inc.
SECTIONS 319 South ( Fret Street. Suite A Temple. Texas 76504
Voice: 254) 742 -2050 Fox: (254) 742 -22055 d
Feb 14 05 10:34a CES 254 742 -2055 p. 7
(------ ... A P.
W il"
r \
10 MAX.
E STONE FINISH PER ARCH. SPEC.
I\ / I MIN_ 19' FACE OF WALL TO BE MORTARED ,. z WITH TYPE N MORTAR OR
PORTLAND MORTAR MIX.
1 %O #509"
+
IMPORTED GRANULAR 2 _
(SANDY) BACKFILL "z �'
COMPACTED 95% IN A,�� 3000
6" LIFTS � gAv 3000 PSI CONC.
k 10'+ (TYP) 1
•, •/-4 7 12 WEEP
6" PVC DRAIN (200' MAX)
"''! � HOLE
STRATAGRID 600_.--- , - ... _
OR EQUIVALENT 4' t4AX (r :owe 'L•� : % 12' ., ELEvATION OF WATER IN
Ilrldri '! 4 CREEK DURING NIGH FLOW
l
. ._ .. !'c .,k _ M iami X 22' MAX
NON -WOVEN GEOTEXTILE --I �..3 _ #909' GR ELLEE , 4 S CLAY
-
_ �.►.�, 'Iv, • I % WEEP (TO BE vERIF1E0)
TM. , % + 4 HOLE
6` PVC DRAIN (200' MAX) f ! 11 �� t` \V/ 1 \�j[[���\\ I
e 0 4 .. . .
CLEAN, BAGGED GRANULAR FILL • - ---
SUCH AS AN ASTM C -33, SIZE 57 �' •• `A -' =� , 1 -
6 #8 I. #709"
5 #509`
CONTINUOUS WALL KEY WRH
SYNKO -FLEX WATERSTOP 5' -6" A-2'_6
(TYP. 9 ALL WALL KEYS)
9' -7" -
- • E OF 1
TYPICAL SECTION — STRUCTURAL WALL D ,
NT5 I � / i
y
NOTES: Ri_NI
_ KRISIINE 8. ANOS S
1. FOR w£EP HOLES AND DRAIN PIPE � 80993 4 -
INSTALLATION AND SPACING SEE GENERAL 1 '`� -
NOTES. 1 ` ;,,,61:79F- / 4 r
Scab: NTS I Plot Dote2 /1 3L05 1 sh,.t 7 6
Project No_: 04 -10 U.,i n.0 er Kw„,
. Nam.: WALL.dwg Drown e?"• KBA ---
ril HAMPTON INN S SUITES
COLLEGE STATION. TEXAS
STONE RETAINING WALLS Comprehensive Engineering Solutions, Inc.
SECTIONS 319 South First Streot. Suite A Temple, Texas 76504
Voice: (254) 742 -2050 Fax: (254) 742 -2055