Loading...
HomeMy WebLinkAboutStaff Commentsy CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 IMI=1J,MZT_1ki IBill �i September 15, 2003 TO: Lee Adams, MDG, Via Fax 693.4243 ✓ FROM: Bridgette George, Assistant Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) -Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: $400 Site Plan Review Fee (this includes the previous 3 reviews and the next 3 reviews) One (1) complete set of revised construction documents for the proposed development with the revised site and landscaping plans attached; If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call Molly Hitchcock or Spencer Thompson at 979.764.3570. Attachments: Staff review comments cc: Billy Martin, Texas Hotel Mgmt, Co., LP, Via fax 260.8709 ERN Architects, Inc., Via fax 817.469.9661 Case file #03- 00500119 Home of Texas A &M University f STAFF REVIEW COMMENTS NO. 6 Project: HAMPTON INN AND SUITES (SP) - 03 -119 PLANNING 1. The 0.33 -acre lot that abuts the subject property by the dumpster enclosure is Lot 2 Block 1 of Greensworld Ph. 3. Please identify the lot as such. 2. Streetscaping requires additional landscaping points. Please include these in the landscaping calculations. 3. No landscape buffer is required for this site. 4. Live oaks are required to be separated from other live oaks by a minimum of 35 feet. 5. The "points provided" does not match the points shown in the "Plant Schedule ". Please reconcile. Reviewed by: Molly Hitchcock Date: September 2, 2003 ENGINEERING 1. Oral comments given to Lee Adams. Reviewed by: Spencer Thompson NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2of2 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 • . • College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM August 20, 2003 TO: Lee Adams, MDG, Via fax 693.4243 � FROM: Bridgette George, Asst. Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: $200 Site Plan Review fee (for the next 3 reviews) One (1) complete set of construction documents for the proposed development with the revised site and landscaping plans attached; If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Billy Martin, Texas Hotel Mgmt, Co., LP, Via fax 260.8709 ✓ ERN Architects, Inc., Via fax 817.469.9661 ✓ Case file # 03- 00500119 STAFF REVIEW COMMENTS No. 4 Project: HAMPTON INN AND SUITES (SP) - 03 -119 Please Note: These comments are only in reference to the Irrigation and Grading plans that were submitted August 6, 2003. They are being accepted as late additions to the plans submitted July 28, 2003 and reviewed in Staff Review Comments #3. PLANNING 1. No comment. Reviewed by: Molly Hitchcock Date: August 11, 2003 ENGINEERING 1. More detailed information is required for development along bank of creek bank. 2. Proposed silt fence location shown is in accurate. 3. 100 -yr floodplain line appears inaccurate. Refer to official LOMR. 4. Show detail of how surface run -off will enter creek from site. Reviewed by: Spencer Thompson Date: August 18, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM May 15, 2003 TO: Lee Adams, Municipal Development Group, Via fax 693 -4243 FROM: Natalie Thomas Ruiz, Development Mana SUBJECT: HAMPTON INN AND SUITES (SP) - Site Plan Staff received the above - mentioned site plan and performed a cursory review. Due to the number of staff comments that could significantly impact the site plan and the information missing from the plans, staff could not perform a complete review. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review: Ten (10) folded copies of the revised site plan. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Texas Hotel Management Company, 1203 University Drive East, CS, TX 77840 ERN Architects, Inc., Via fax (817) 469 -9661 Billy Martin, 1203 University Drive East, CS, TX 77840 Case file #03- 00500119 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 1 Project: HAMPTON INN AND SUITES (SP) — 03 -119 Plans show building in utility easement. It is understood by Staff that, at this time, plans are to be turned in to relocate sewer line, dedicate a new easement and abandon existing easement. This Site Plan will be reviewed with this in mind. However, under no circumstances will the Site Plan be approved and stamped without the removal of the easement and relocation of sewer as needed. This review has been stopped. Because the extent of the development intended to be approved through this site plan submittal is unclear, and because of incomplete or incorrect information on the plans, Staff has only made a cursory review of this submittal. A full review will be made of the next submittal. PLANNING 1. What is the current intention for the restaurant pad site? Will the property be replatted or will the pad site be a future phase of the building plot? Is there an intent to have the restaurant site plan reviewed at this time as a future phase, or will it be submitted to the City at some time in the future? The current intent of the pad site should consistently be treated the same on all plans. 2. Please provide a more detailed location map that includes an outline of the subject property. 3. Please identify the zoning of the parcel and all abutting parcels and total building square footage on the site plan. 4. General Site Plan Note #4 states "See site plan for specific site notes and data." Only an "Overall Site Plan" was submitted. 5. Please identify the driveway /aisle as existing. 6. Setbacks for C -2 are as follows: front =25 ft., rear =15 ft., side =7.5 ft., and side street= 15 ft. 7. Please show required and provided parking space information. 8. Please clarify fire lane and curb locations. 9. Please ensure that the Symbol and Line Legend is consistent with what is being shown on the plan. 10. Please locate the dumpsters where they will not be able to be seen from the ROW. The screening fence should be 8 feet tall. 11. Identify fire hydrants on the site plan also. 12. In the fire lane note on the Overall Site Plan, please reference the fire lane detail. 13.A buffer is required between the subject property and any adjacent platted lot. 14. Please clearly identify the property lines on the landscape plan. 15. Several of the Site Plan Notes on page L1 are inappropriate for the landscaping plan. 16. Please show the irrigation layout on the irrigation plan. 17. Three acres is equal to 130,680 sq.ft. Required buffer yards may be removed from the total square footage when calculating total required landscaping points. 18. Please identify the linear feet of buffer. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 4 19. Parking must be screened from the ROW. If a berm is intended to be used as a screening device, its location(s) should be included on the landscaping plan. 20. Please note on the site plan that all disturbed earth must be 100% covered with established grass or groundcover prior to C.O. Reviewed by: Molly Hitchcock Date: May 15, 2003 ENGINEERING 1. Sheet C1, scale does not appear accurate. 2. Sheet C1, North arrow does not appear accurate 3. Sheet C2, please show grading in a more legible form or font. 4. No detention required if drainage is discharged directly to creek channel. It is not possible to approve the grading of the site per the grading plans at this time due to font size and cluttering. 5. Sheet C2, show proposed erosion control measures. 6. Show any proposed stream improvements. 7. This lot was removed from the SFHA by way of a LOMR -F. 8. Erosion Control Note # 5 should read TCEQ rather than EPA. 9. Sheet C3, this sheet has no labels on any utility. 10. Proposed private sewer location must be shown. 11. There are existing tees in the line. Additional tees should not be installed. 12. On profiles, state "Minimum 4 -ft bury". 13. Label all fittings, tee sizes, etc. Domestic and irrigation lines to be sized. Estimated flow information must be provided on this Plan. The City will determine your meter sizes from the flow data provided. 14. Is 8" proposed to go into building? 15. Is 8" proposed to go to hydrant "A "? 16. All water lines must be in easements. Easements must be dedicated prior to approval of plans. Options are replat property, blanket easement by plat, separate /specific easements. Reviewed by: Spencer Thompson Date: May 14, 2003 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design.(pull boxes provided by the city. 5. Developer provides digital AutoCAD 14 version of plat and /or site plan. email to rbolin(�ci.college- station.tx.us 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 4 8. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). Reviewed by: Ronnie Bolin MISCELLANEOUS Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 4 of 4 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM July 21, 2003 TO: Lee Adams, MDG, Via fax 693.4243 FROM: Bridgette George, Assistant Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: One (1) complete set of construction documents for the proposed development with the revised site and landscaping plans attached If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Billy Martin, Texas Hotel Mgmt, Co, LP, Via fax 260.8709 ✓ ERN Architects, Inc., Via fax 817.469.9661 Case file #03- 00500119 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 2 Project: HAMPTON INN AND SUITES (SP) - 03 -119 This review has been stopped. Because of incomplete information on the plans, Staff has only made a cursory review of this submittal. A full review will be made of the next submittal. As a complete submittal was not made before the effective date of the Unified Development Ordinance (June 13, 2003), this cursory review and all future reviews will be reviewed for compliance with the Unified Development Ordinance. Also, hotels and restaurants are not permitted uses in C -2 zoning districts. A successful rezoning will be necessary before the plans may be stamped approved. PLANNING 1. Please clearly identify the site's property lines on the Overall Site Plan. 2. Please ensure that the Symbol and Line Legend is consistent with what is being shown on the plan. 3. Please show the phase line on the Overall Site Plan (as well as the Landscaping Plan). 4. The dumpsters should not be gated. There is a reference to a screening fence detail, but the detail could not be found in the plans. 5. Please show a smooth transition from the width of the existing drive aisle to the width of the expanded drive aisle. 6. When parking is located closer than 15 feet from a ROW line, there have to be two interior islands (360 sq.ft.) after every seven parking spaces. 7. A buffer is required between the subject property and any adjacent platted lot. 8. Please include all site planning notes on the Overall Site Plan and reference the Site Plan as the Landscaping Plan. 9. Please include all landscaping and streetscaping calculations on the Landscaping Plan. Required buffer yards may be removed from the total square footage when calculating total required landscaping points. 10. Please identify plant sizes, point values, quantity, and total points. 11. Plant species must be appropriate for Zone 8 of the USDA Hardiness Zone Map. 12. Parking must be screened from the ROW. If a berm is intended to be used as a screening device, its location(s) should be included on the landscaping plan. 13. Please note on the site plan that all disturbed earth must be 100% covered with established grass or groundcover prior to C.O. 14. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 3 15.All Back Flow devices must be installed and tested upon installation as per City Ordinance 2394. Reviewed by Molly Hitchcock Date: July 15, 2003 ENGINEERING 1. Sheet 5: Please call out all fittings. How does 8" line transition from 18 "x8" tee, on Water Line A to 8" line at Sta. 0 +00? 2. Why are both 8" lines connected parallel to main? This connection will require isolation valve(s). 3. Water line B, why two 8 "x8 "x8" tees? Plugs valves, etc? Small taps for water service meters do not need valves whereas, 8" tees require additional valving. 4. Show transitions from 8" line to 6" FH. 5. Water line C requires a valve for supply to building after bend. 6. A fire hydrant flow analysis must be performed to ensure sufficient flow is provided for structure. Please submit calculations for final approval according to Appendix B in 2000 International Fire Code. 7. Show existing easement. You may label this "To be abandoned ". 8. Show future sewer line and approximate location of sewer tap, building line, size, etc. 9. Water line profiles do not show sewer line crossings (approx.). 10. How will erosion control be dealt with at "curb leave -out' to creek? Reviewed by: Spencer Thompson Date: July 17, 2003 MISCELLANEOUS 1. Enclosure of the dumpsters is shown to be 10 by 13 feet. It needs to be 12 by 12 feet when measured from the inside. Reviewed by: Pete Caler NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3 -I CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM August 7, 2003 TO: Lee Adams, MDG, Via fax 693.4243- FROM: Bridgette George, Assistant Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) complete set of construction documents for the proposed development with the revised site and landscaping plans attached; Easement Dedication Sheet and required documents. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments Easement Dedication Sheet cc: Billy Martin, Texas Hotel Mgmt, Co., LP, Via fax 260.8709 ERN Architects, Inc., Via fax 817.469.9661 Case file #03- 00500119 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 3 Project: HAMPTON INN AND SUITES (SP) - 03 -119 PLANNING 1. Please show Lot 2 as an abutting parcel and identify its ownership. 2. The title block identifies the lot as 3 acres. If the note above the Parking Analysis is identifying the size of the current phase, please call it out. 3. Please identify the proposed zoning for Lots 1 and 2. 4. For the five angled parking spaces, please call out the angle and stall dimensions. 5. Please describe the dumpster enclosure. 6. If the rezoning is successful, no buffer will be necessary. 7. Streetscaping requires additional landscaping points. Please include these in the landscaping calculations. Reviewed by: Molly Hitchcock Date: July 29, 2003 ENGINEERING 1. Always show existing and proposed utility easements on all drawings. 2. Sewer line has moved. Plans cannot be checked. 3. It is not possible to review the water line plans when water lines do not stand out. Please remember that these are the plans to construct the City water infrastructure. Make the plan and profile drawings of decent size for the contractor, the inspector and all parties involved to utilize them. Reviewed by: Spencer Thompson Date: August 6, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2 r* CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM , 2003 TO: Stewart Kling, Kling Engineering & Surveying, Via fax 846.8252 FROM: Bridgette George, Assistant Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) — Construction Documents Staff reviewed the above - mentioned engineering documents as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review and approval of the plans: One (1) set of revised construction documents. If you have any questions or need additional information, please call Spencer Thompson or myself at 764.3570. Attachments: Staff Review Comments Cc: Case file no. (03- 00500119) Home of Texas A&M University ENGINEERING REVIEW COMMENTS No. 1 1. Existing pipe (21") connects to proposed pipe (24 "). TNRCC §317 regulations require the tops of these lines through the manhole to me aligned. 2. Add note on Sheet SS -1 that proposed manholes are 6 -ft in diameter. 3. Manhole at Sta 1 +67.3 requires a Flow -line In and Flow -line Out elevation noted on design plans with a minimum 0.1 ft elevation difference. 4. Note concerning "rubber boot" added to manhole is not valid. Manhole invert and flow line will need to be re- shaped for new pipe and new outlet. 5. Concerning line capacity calculations; TNRCC §317 requires a minimal acceptable "n" value of 0.013. Preliminary calculations show a 24" sewer at 0.08% slope, n = 0.013 has a capacity of 6.4 cfs. This is close enough to the 6.55 being replaced. The upstream line capacity was also considered. Reviewed by: Spencer Thompson Date: July 23, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City of College Station will constitute a completely new review. Page 2 of 2 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM August 20, 2003 TO: Lee Adams, MDG, Via fax 693.4243 FROM: Bridgette George, Asst. Development Manager SUBJECT: HAMPTON INN AND SUITES (SP) Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: $200 Site Plan Review fee (for the next 3 reviews) One (1) complete set of construction documents for the proposed development with the revised site and landscaping plans attached; If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Billy Martin, Texas Hotel Mgmt, Co., LP, Via fax 260.8709 ERN Architects, Inc., Via fax 817.469.9661 Case file # 03- 00500119 STAFF REVIEW COMMENTS No. 4 Project: HAMPTON INN AND SUITES (SP) - 03 -119 Please Note: These comments are only in reference to the Irrigation and Grading plans that were submitted August 6, 2003. They are being accepted as late additions to the plans submitted July 28, 2003 and reviewed in Staff Review Comments #3. PLANNING 1. No comment. Reviewed by: Molly Hitchcock Date: August 11, 2003 ENGINEERING 1. More detailed information is required for development along bank of creek bank. 2. Proposed silt fence location shown is in accurate. 3. 100 -yr floodplain line appears inaccurate. Refer to official LOMR. 4. Show detail of how surface run -off will enter creek from site. Reviewed by: Spencer Thompson Date: August 18, 2003 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 2 of 2