Loading...
HomeMy WebLinkAboutStaff Comments Ckif CITY OF COLLEGE STATION Planning d• Development Service 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM August 14, 2008 TO: Rabon Metcalf, RME Consulting Engineers, via fax 69t0329 FROM: Lindsay Boyer, AICP, Senior Planner 1 oJi'(fot SUBJECT: CREEK MEADOWS (PP) - Preliminary Plat Staff reviewed the above - mentioned Preliminary Plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. If all comments have been addressed and the following information submitted by Monday, August 18th, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled for September 18th, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24" x 36" copy of the revised Preliminary Plat; and Nineteen (19) 11" x 17" copies of the revised Preliminary Plat. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed, your project will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P &Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http://www.cstx.gov/home/index.asp?page=2481. Please note that a Mylar original of the revised preliminary plat will be required after P &Z approval and prior to processing subsequent final plats. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Todd Carnes, Creek Meadow Partners, via fax 694.4141 Case file #08- 00500175 1. This plat is outside the College Station Utility electric service area. Customer will have to get with their electric supplier for this area to determine electric service specifications and requirements. Reviewed by Timothy Crabb, CSU Electric, (979) 764 -3439. Date: 08/05/08. 08/14/2008 12:11:30 PM -0500 FAXCOM PAlil✓ L ur Y Offf C ri of Col GE STATION P"ng* . s ue ...: -::.. 1101 Texas Avenue, P.O. Box 9960 Co "ege Station, Texas 77842 Phone 9. '9.764.3570 / Fax 979.764.3496 MEMORANDUM August 14, 2008 TO: Rabon Metcalf, RME consulting Engineers, via fax 690.0329 FROM: Lindsay Boyer, AICP. Senior Planner SUBJECT: CREEK MEADOWS i :PP) - Preliminary Plat - - - -- — Staff reviewed the above mentionecl Preliminary Plat as requested. The following page is a list of staff review comments detailing it ins that need to be addressed. If all comments have been addressed and the following inform ation submitted by Monday, August 18th, 10:00 a.m., your project will be placed on the n( xt available Planning and Zoning Commission meeting scheduled for September 18th, 7: )0 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24" x 36" cony of the revised Preliminary Plat; and V Nineteen (19) 11" x 17" copies of the revised Preliminary Plat. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the Cty of College Station. Please note that if all comments have not been addressed, your projec: will be pulled from the scheduled Planning & Zoning Commission agenda. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P &Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http: //www.c stx.gov/home /index.asp ?page =2 Please note that a Mylar original of the revised preliminary plat will be required after P &Z approval and prior to processing :subsequent final plats. If you have any questions or need additional information, please call roe at 979.764.3570. Attachments: Staff review comments cc: Todd Carnes, Creek Meadow Partners, via fax 694.4141 Case file #08- 00500175 b AO q: CU 08/14/2008 12:11:30 PM -0500 FAXI::OM PAUL 3 ur 4 V STAFF REVIEW COMMENTS NO. 1 Project: CREEK MEADOWS (PP) - 08- 00500175 PLANNING d k4 Section 1C does not close per Mapping. Please revise the calls. early show delineation between Section 4 and phases 1, 2A, and 2B on the coversheel:. V Correct general note 7 to state The existing use of this tract is vacant, except for Section 1A, Phases 1 -2 and Section 1B, Phases 1 -4, which are currently developed as duplex and single - family residential, respectfully. The proposed uses are commercial, open space, ulti- family, and single - family residential in compliance with the approved Master Plan. . Is note 3 under Homeowner's ,Association (HOA) from the previous preliminary plat still necessary since a portion of the project still lies outside the City limits? Please include if it is necessary, but clarify that it is ally applicable to the portions outside the City Limits, same ith Note 3 under Construction ::.tandards & Notes.' lease modify the note regardir g Common Areas being unbuildable. There is a clubhouse and pool located on some common area, so clearly they are buildable, but not intended for idential unit construction. . Please provide a breakdown of number of Tots by phase for the previous and current preliminary plat. My calculation; are not coming out to the difference between the total number of lots for the two pla:s. This does not have to be on the plat itself, just as a reference so I can more easily ic'entify where there are changes for the staff report. Reviewed by: Lindsay Boye Date: August 11, 2008 ENGIN RING COMMENTS NO. 1 Depict the 100 -yr floodplain I:hat you determined in your drainage report on the plat and ovide finished floor elevation for the Tots impacted. rovide cross - access ease nents on non - residential lots in Section 1 C, fronting on Greens Prairie Road. AL4(> See 4)0 7E # 17. Reviewed by: Carol Cotter Date: August 11, 2008 No FIRE combustibles will be allowed on site until all- weather roads and fire hydrants have ben t. epted by the City. 0 A more than a six percent (6%; grade is allowed on any length of fire lane. Fire Hydrant shall be located v ithin a six hundred and fifty foot radius from any part of a cture. Measured on a road sir-face as afire apparatus would lay hose. Single fire access is limited to th rty (30) single - family residential units or one hundred (100) multi - family residential units. Reviewed by: Steve Smith Date: 08/04/2008 SANI N . Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: August 6, 2008 GENERAL ELECTRICAL COMMENTS 08/14/2008 12:11:30 PM -0500 FAXCOM PAGE 4 OF 4 . This plat is outside the College Station Utility electric service area. Customer will have to get with their electric supplier for this area to determine electric service specifications and requirements. Reviewed by Timothy Crabb, CSU Electric, (979) 764 -3439. Date: 08/05/08. STAFF REVIEW COMMENTS NO. 1 Project: CREEK MEADOWS (PP) - 08- 00500175 PLANNING 1. Section 1C does not close per Mapping. Please revise the calls. 2. Clearly show delineation between Section 4 and phases 1, 2A, and 2B on the coversheet. 3. Correct general note 7 to state "The existing use of this tract is vacant, except for Section 1A, Phases 1 -2 and Section 1B, Phases 1 -4, which are currently developed as duplex and single - family residential, respectfully. The proposed uses are commercial, open space, multi - family, and single - family residential in compliance with the approved Master Plan. 4. Is note 3 under Homeowner's Association (HOA) from the previous preliminary plat still necessary since a portion of the project still lies outside the City limits? Please include if it is necessary, but clarify that it is only applicable to the portions outside the City Limits, same with Note 3 under Construction Standards & Notes. 5. Please modify the note regarding Common Areas being unbuildable. There is a clubhouse and pool located on some common area, so clearly they are buildable, but not intended for residential unit construction. 6. Please provide a breakdown of number of Tots by phase for the previous and current preliminary plat. My calculations are not coming out to the difference between the total number of lots for the two plats. This does not have to be on the plat itself, just as a reference so I can more easily identify where there are changes for the staff report. Reviewed by: Lindsay Boyer Date: August 11, 2008 ENGINEERING COMMENTS NO. 1 1. Depict the 100 -yr floodplain that you determined in your drainage report on the plat and provide finished floor elevation for the lots impacted. 2. Provide cross - access easements on non - residential lots in Section 1C, fronting on Greens Prairie Road. Reviewed by: Carol Cotter Date: August 11, 2008 FIRE 1) No combustibles will be allowed on site until all- weather roads and fire hydrants have been accepted by the City. 2) No more than a six percent (6 %) grade is allowed on any length d fire lane. 3) A Fire Hydrant shall be located within a six hundred and fifty foot radius from any part of a structure. Measured on a road surface as a fire apparatus would lay hose. 4) Single fire access is limited to thirty (30) single - family residential units or one hundred (100) multi - family residential units. Reviewed by: Steve Smith Date: 08/04/2008 SANITATION 1. Sanitation is ok with this project. Reviewed by: Wally Urrutia Date: August 6, 2008 GENERAL ELECTRICAL COMMENTS