Loading...
HomeMy WebLinkAboutApplication • FOR OFFICE USE ONLY . P &Z CASE NO.: V8 r � crry OF COLLEGE. STATION DATE SUBMITTED: E 'tY Plannrng ' 1)eve n nnnaa 5errices g PRELIMINARY PLAT APPLICATION 11%- ` 5' The following items must be submitted by an established filing deadline date for P &Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: '400 Filing Fee 4 /A- $100 Variance Request to Subdivision Regulations (if applicable) /Application completed in full. l Fourteen (14) folded copies of plat. (A revised mylar original must be submitted after approval.) A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. A/A Rezoning Application if zone change is proposed. Parkland Dedication requirement approved by the Parks & Recreation Advisory Board, please provide proof of approval (if applicable). Date of Preapplication Conference: June 25, 2008 NAME OF SUBDIVISION cutting Edge Edition SPECIFIED LOCATION OF PROPOSED SUBDIVISION 7103 Rock Prairie Road, College Station, TX APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Mark Delgado, Design Project Manager - dcb Construction Company, Inc. Street Address 909 East 62nd Avenue City Denver State Colorado Zip Code 80216 E -Mail Address mdelgado @dcbl . c Phone Number 303 - 287 -5525 Fax Number 303 -An -6q8.5 PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): Name S tephen Ross - Cutting Edge Self Storage ADT L.C. Street Address 5630 s. Waterbury Way, Ste. B -100 City Murray State Ut Zip Code 84121 E -Mail Address Phone Number 866- 970 -3343 Fax Number 801- 273 -1634 ARCHITECT OR ENGINEER'S INFORMATION: Name Chris Harris, P.E. - Kimley -Horn and Associates, Inc. Street Address 111 University Drive East, Suite 105 City College Station State Texas Zip Code 77840 E -Mail Address chris.harris @kimley - horn.com Phone Number 979- 846 -8401 Fax Number 979 - 846 -8450 Page 1 of 4 Total Acres of Subdivision 5.005 R -O -W Acreage o .31 Total # Of Lots 1 Number of Lots By Zoning District 1 / C-3 / / Average Acreage of Each Residential Lot By Zoning District: / / / / Floodplain Acreage 0 Are you proposing to dedicate park land by acreage or fee in lieu of land? By acreage Are you proposing to ❑ develop the park or • dedicate the development fee? (Check one) A statement addressing any differences between the Preliminary Plat and approved Master Plan (if applicable) Requested variances to subdivision regulations & reason for same S idewalk waver for 10' sidewalk and tree wells along building facade. Requested oversize participation None Parkland Dedication due prior to filing the Final Plat: ACREAGE: 0 . 165 # of Acres to be dedicated o # of acres in floodplain o # of acres in detention o # of acres in greenways OR FEE IN LIEU OF LAND: # of Single- Family Dwelling Units X $900* = $ (date) Approved by Parks & Recreation Advisory Board * Projects that were vested prior to January 1, 2008, per Chapter 245 of the Texas Local Government Code may be assessed a different amount. Please contact City staff for additional information. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat and attests that all respective owners have been identified and signed this application, or proof of authority to sign provided with application. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY, THIS APPLICATION MUST BE ACCOMPANIED BY A POWER OF ATTORNEY STATEMENT FROM THE OWNER. �I Sign. ure and Tit e v Date Page 2 of 4 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 Crr) Cot f S r,AI ION FOLDED COPIES OF PLAT FOR REVIEW PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: I I 1. Mylar original of approved master plan (Mylar must be on file or submitted before the preliminary plat will be reviewed). 2. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 3. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. I7 4. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. [f Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) W Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) v� Engineer's scale in feet. EZ Total area intended to be developed. 5. North Arrow. [v� 6. Location of current city limit lines and current zoning district boundary. 7. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. V 8. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) 9. Primary control points or descriptions and ties to such control point, to which , later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original survey of which it is a �/ part. IV 10. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. 11. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. Page 3 of 4 V 12. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. 13. Proposed land uses (In compliance with Land Use Plan). 14. Proposed zoning changes, if any, submit formal rezoning request. 15. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed d Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. [VI Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and /or intersection angles meet ordinance. Alleys. Reserve tracts. Well site locations. Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product transported through the line. Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient size /depth to meet the utility master plan and any future growth areas. Easements. I J Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. [1I A number or letter to identify each lot or site and each block. n Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) Public areas Other public improvements, including but not limited to parks, schools and other public facilities I I 16. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and � infrastructure costs should be distributed evenly throughout the subdivision. L� / 17. Are there impact fees associated with this development? Yes V No �I 18. If requesting oversize participation items, are the necessary impact studies included? IYes INo VN /A Page 4 of 4