HomeMy WebLinkAboutStaff Comments PRELIMINARY PLAT STAFF REVIEW COMMENTS NO. 1 Project: CRESCENT POINTE PH. 4 (PP) - 08- 00500257 PLANNING (Preliminary Plat) 1. Please update the title page index sheet (looks like it was used for a replat of phase 2, at one time). 2. Please revise zoning to reflect existing A -P zoning line. Please also indicate the proposed zoning for that area. 3. The volume & page of all easements will need to be provided on the mylar (whether by separate instrument or plat). The City will need first right of refusal of the off -site easement in Common Areas A & B. 4. Please provide lot dimensions on all lots, including townhome and A -P lots in phase 4. 5. The net density of the townhomes is 48 units on 4.15 acres, or 11.8 du /ac. Please indicate this by way of a note on the plat. 6. The preliminary plat and final plat for phase 4 need to be consistent. Make any necessary changes (ie: easement locations on lots, street right -of -way at previous cul -de -sac, etc.). 7. All sidewalks and utilities should be shown. Related specifically to Phase 4, sidewalks are required on Crescent Pointe Parkway and on Crescent Ridge Drive. Reviewed by: Jennifer Prochazka Date: October 28, 2008 ENGINEERING COMMENTS NO. 1 (Preliminary Plat) 1. Please illustrate all requires infrastructure on this preliminary plat (ie. water, sanitary sewer, storm sewer, sidewalks, etc). 2. Please provide all surveying calls, as it appears several side lot line calls are missing. 3. Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION (preliminary Plat 1. Most easements on site are existing. Electric facilities will be designed within existing easements where possible. 2. Developer provides temporary blanket easement for construction purposes or provides descriptive easements for electric infrastructure as designed by CSU for electric lines. 3. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. 4. If applicable, the following easements will be required: ➢ A 20' PUE between Lots 5R & 7R Block 1. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. Home of Texas A &M University 2. CSU will provide drawings for electrical installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser. 4. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 5. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 7. Developer installs pull boxes per CSU specs and design (pull boxes provided by CSU). 8. Developer provides digital AutoCAD 2000 or later version of plat and /or site plan. Email to: sweido @cstx.gov. 9. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 10. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 11. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 10 -21 -08 SANITATION (preliminary plat) 1. Need to discuss what type of garbage service they will be requesting in order to determine level of service. Reviewed by: Wally Urrutia Date: October 16, 2008 FINAL PLAT STAFF REVIEW COMMENTS NO. 2 Project: CRESCENT POINTE PH 4 BL3 LOTS2 & 3 (FP -R - 08- 00500221 PLANNING (final plat) 1. Application should be amended to include the number of A -P lots, as is currently zoned. 2. Since the plat also includes property that has never been previously platted, the title of the plat should say "including a replat of" instead of "being a replat of." 3. Please include the total number of lots being platted and the total acreage to the title block. 4. Label original plat as "Original Plat." 5. Label new plat as "Replat and Final Plat." 6. C.A. #1 should be "shaded" on the drawing as other common areas are and as the legend indicates. Home of Texas A &M University 7. The volume and page of all easements will need to be provided on the mylar (either by separate instrument or plat). The City will need first right of refusal of the off-site easement in Common Areas A & B. 8. Please provide lot dimensions on all Tots (specifically, the lot lengths are missing from some lots). 9. The net density of the townhomes is 49 units on 4.15 acres, or 11.8 du /ac. Please revise note number 6. 10. A note should be added to indicate current zoning. 11. A note should be added referencing the Administrative Adjustment that will be approved for the lot depth of the A -P lots (write the note as if it already has been). Reviewed by: Jennifer Prochazka Date: October 28, 2008 ENGINEERING COMMENTS NO. 2 (Final Plat) 1. Please provide all surveying calls, as it appears several side lot line calls are missing. 2. The modifications to the cul -de -sac are illustrated differently between the preliminary and final plat. 3. On Sheet 3, the existing PUE at the rear of CA # 3, 4, 5, 6, 7 does not appear. 4. On Sheet 3, the existing PUE along the side of CA # 7 does not appear. 5. Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 Home of Texas A &M University ( Ike " 1144 CITY OF COT ,T FGE STATION Planning d Development Service 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM October 29, 2008 TO: DWS Development, via fax 979.822.1763 FROM: Jennifer Prochazka, AICP, Senior Planner SUBJECT: CRESCENT POINTE Phase 4 (Preliminary & Final Plats) Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please remit revised documents immediately to remain on the November 6, 2008 Planning and Zoning Commission meeting. The meeting is scheduled for 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. One (1) 24 "x36" copy of BOTH the revised preliminary plat and final plat; Nineteen (19) 11"x17" copies of BOTH the revised preliminary plat and final plat; Parkland Dedication in the amount of $44,100 (based on 49 units) must be submitted prior to the filing of the final plat; and One (1) copy of the digital file of the final plat on diskette or e-mail to mtrevino @cstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. The agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http://www.cstx.gov/home/index.asp?page=2481 Please note that a Mylar original of the revised final plat will be required after P &Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Emanuel Glockzin, Jr., Crescent Pointe Holdings, Inc., via fax 979.846.0783 Kling Engineering & Surveying, via fax 979.846.8252 Case file #08- 00500221 Case file #08- 00500257 Home of Texas A &M University PRELIMINARY PLAT STAFF REVIEW COMMENTS NO. 1 Project: CRESCENT POINTE PH. 4 (PP) - 08- 00500257 PLANNING (Preliminary Plat) 1. Please update the title page index sheet (looks like it was used for a replat of phase 2, at one time). 2. Please revise zoning to reflect existing A -P zoning line. Please also indicate the proposed zoning for that area. 3. The volume & page of all easements will need to be provided on the mylar (whether by separate instrument or plat). The City will need first right of refusal of the off -site easement in Common Areas A & B. 4. Please provide lot dimensions on all lots, including townhome and A -P Tots in phase 4. 5. The net density of the townhomes is 48 units on 4.15 acres, or 11.8 du /ac. Please indicate this by way of a note on the plat. 6. The preliminary plat and final plat for phase 4 need to be consistent. Make any necessary changes (ie: easement locations on lots, street right -of -way at previous cul -de -sac, etc.). 7. All sidewalks and utilities should be shown. Related specifically to Phase 4, sidewalks are required on Crescent Pointe Parkway and on Crescent Ridge Drive. Reviewed by: Jennifer Prochazka Date: October 28, 2008 ENGINEERING COMMENTS NO. 1 (Preliminary Plat) 1. Please illustrate all requires infrastructure on this preliminary plat (ie. water, sanitary sewer, storm sewer, sidewalks, etc). 2. Please provide all surveying calls, as it appears several side lot line calls are missing. 3. Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION (preliminary Plat 1. Most easements on site are existing. Electric facilities will be designed within existing easements where possible. 2. Developer provides temporary blanket easement for construction purposes or provides descriptive easements for electric infrastructure as designed by CSU for electric lines. 3. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. 4. If applicable, the following easements will be required: ➢ A 20' PUE between Lots 5R & 7R Block 1. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. Home of Texas A &M University 2. CSU will provide drawings for electrical installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser. 4. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 5. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 7. Developer installs pull boxes per CSU specs and design (pull boxes provided by CSU). 8. Developer provides digital AutoCAD 2000 or later version of plat and /or site plan. Email to: sweido @cstx.gov. 9. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 10. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 11. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 10 -21 -08 SANITATION (preliminary plat) 1. Need to discuss what type of garbage service they will be requesting in order to determine level of service. Reviewed by: Wally Urrutia Date: October 16, 2008 FINAL PLAT STAFF REVIEW COMMENTS NO. 2 Project: CRESCENT POINTE PH 4 BL3 LOTS2 & 3 (FP -R - 08- 00500221 PLANNING (final plat) 1. Application should be amended to include the number of A -P Tots, as is currently zoned. 2. Since the plat also includes property that has never been previously platted, the title of the plat should say "including a replat of" instead of "being a replat of." 3. Please include the total number of lots being platted and the total acreage to the title block. 4. Label original plat as "Original Plat." 5. Label new plat as "Replat and Final Plat." 6. C.A. #1 should be "shaded" on the drawing as other common areas are and as the legend indicates. Home of Texas A &M University 7. The volume and page of all easements will need to be provided on the mylar (either by separate instrument or plat). The City will need first right of refusal of the off -site easement in Common Areas A & B. 8. Please provide lot dimensions on all lots (specifically, the lot lengths are missing from some lots). 9. The net density of the townhomes is 49 units on 4.15 acres, or 11.8 du /ac. Please revise note number 6. 10. A note should be added to indicate current zoning. 11. A note should be added referencing the Administrative Adjustment that will be approved for the lot depth of the A -P lots (write the note as if it already has been). Reviewed by: Jennifer Prochazka Date: October 28, 2008 ENGINEERING COMMENTS NO. 2 (Final Plat) 1. Please provide all surveying calls, as it appears several side lot line calls are missing. 2. The modifications to the cul -de -sac are illustrated differently between the preliminary and final plat. 3. On Sheet 3, the existing PUE at the rear of CA # 3, 4, 5, 6, 7 does not appear. 4. On Sheet 3, the existing PUE along the side of CA # 7 does not appear. 5. Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 Home of Texas A &M University KLING ENGINEERING & SURVEYING Consulting Engineers • Land Surveyors 4101 Texas Avenue, Suite A Post Office Box 4234 Bryan, Texas 77802 Bryan, Texas 77805 Telephone 979/846 -6212 Fax 979/846 -8252 B.J. Kling, P.E., R.P.L.S. (Inactive) S.M. Kling, R.P.L.S. Memo: November 13, 2008 To: City of College Station - Development Services c/o Josh Norton From: Fred Paine, P.E��� Re: Crescent Pointe ' a 4, Block 3, Lots 2 & 3 - Engineering Comments No. 2 (Construction Document Comments) The following is in response to November 13 Engineering review: 1. Revised. 2. Refer to sheet DT -1, Storm Sewer Notes, Note #2 3. Refer to "Inset A" on sheet ST -2 for P/P & sheet DT -1 for details on concrete sloped end treatment, apron, energy dissipaters, and rip rap. 4. Revised - Labeled 5. Sanitary Sewer Line "D" is a new SSMH, Top of SSMH revised to match proposed finished grade, notes added to each sheet regarding top of SSMH finished grade adjustments. 6. Added stub out length, gate valve & blow off valve to station label. 7. Majority of waterline is at 4'+ bury. Portions are at 2.5' -4' bury with no segments less than 2.5' bury. Cover in some instances had to be minimized to allow for adequate separation distances from crossing utility lines. TNRCC rules allow for a minimum 2' bury. Segments with 2.5' -4' cover will vary from the B /CS Design Guideline Manual. 8. To be provided prior to construction. KLING ENGINEERING & SURVEYING Consulting Engineers • Land Surveyors 4101 Texas Avenue, Suite A Post Office Box 4234 Bryan, Texas 77802 Bryan, Texas 77805 Telephone 979/846 -6212 Fax 979/846 -8252 B.J. Kling, P.E., R.P.L.S. (Inactive) S.M. Kling, R.P.L.S. Memo: November 6, 2008 To: City of College Station - Development Services c/o Josh Norton From: Fred Paine, P. Re: Crescent Point se 4, Block 3, Lots 2 & 3 - Engineering Comments No. 1 (Construction Document Comments) The following is in response to September 29 Engineering review: 1. Acknowledged - Submitted with this transmittal 0 Private improvements removed from R.O.W. 3. Fire access drive pavement type revised to be 24' B -B concrete section 4. Fire access drive curb return radius revised to 25.0' 5. Fire access gate depicted on plan 6. Structural backfill areas dimensioned in profile view of individual utility plan sheets mil► Detailed information depicting grading added to plan sheet Added to plan sheet(s) 9. Ductile iron pipe already noted in profile view, Structural Backfill or Cement Stabilized Sand usage dimensioned in profile view 10. Noted on plan, pier detail added to sheet DT -3 11. Notation provided in Note #1 of the General Notes section Sheet DT -1 12. Verified - depths labeled in profile view 13. Structural Backfill or Cement Stabilized Sand usage dimensioned in profile view Revised Line size, slope & flowline to accommodate Summit Crossing diP Illustrated in profile view 6. Refer to key note item 'A', line depicted in profile view 17. 2' separation provided 18. Storm Sewer crossing depicted and labeled 19. 2' separation provided 20. Stub outs provided for future looping (Sheet W -3 Added) 21. 2' separation provided 22. Gate valves labeled in profile view 23. Maximum spacing is 616 ft 24. Acknowledged, SWP3 provided in plan set, Contractor to file NOI Additional Changes: 1. Added Waterline stub -outs to south and east property lines for future looping 2. Revised Sanitary Sewer Line 'B' w.r.t. Summit Crossing Coordination , ti 3. Revised Fire access road culvert per TXDOT comment 4. Revised details on Fire access road 10 Page 1 of 2 Josh Norton - Crescent Pointe / Summit Crossing Sanitary Sewer From: Fred Paine <fred @klingeng.com> To: Josh Norton <Jnorton @cstx.gov >, Alan Gibbs <Agibbs @cstx.gov >, David Scarmardo <david @scarmardofoods.com> Date: 10/30/2008 4:21 PM Subject: Crescent Pointe / Summit Crossing Sanitary Sewer Original Message Subject:RE: Water -Sewer Study Date:Thu, 30 Oct 2008 16:15:20 -0500 From:Rabon A. Metcalf, P.E. <rabon @rmeneineer com> To:'Fred Paine' <fred @klingene com> References: <021 aOl c93489$35906830$a0b13890$ @com> <490A056F,5050209 @klingeng.com> I concur with this. Ivml]-- > <!-- [endif]-- ><I - -[if Ivml]-- > <I-- [endif] -- >Rabon A. Metcalf, P.E. <! - -[if lvml]-- ><!-- [endif] - -> RME Consulting Engineers<I - -[if Ivml]-- > <I-- [endif] - -> 1391 Seamist Lane <77845> P.O. Box 9253 College Station, TX 77842 PH: (979) 690-0329 FX: (979) 690 -0329 t*o.ru�r( Eryine.ers MB: (979) 219 -4174 THE ELECTRONIC DATA, CONTENT, INFORMATION, AND /OR DRAWINGS GENERATED, BY RME CONSULTING ENGINEERS (RME), ATTACHED OR CONTAINED IN THIS ELECTRONIC TRANSMITTAL IS CONSIDERED BY RME TO BE CONFIDENTIAL. WHEN ISSUED, ITS USE IS INTEND SOLELY FOR THE INDIVIDUAL OR ENTITY TO WHICH IT IS ADDRESSED. THIS MATERIAL IS INTENDED FOR USE BY THE RECIPIENT NAMED, ONLY, AND PERMISSION IS NOT GRANTED TO THE RECIPIENT FOR DISTRIBUTION OF THESE DOCUMENTS IN ANY FORM OR FASHION. THE RECIPIENT UNDERSTANDS THAT THIS DATA IS AUTHORIZED AS IS" WITHOUT ANY WARRANTY AS TO ITS PERFORMANCE, ACCURACY, FREEDOM FROM ERROR, OR AS TO ANY RESULTS GENERATED THROUGH ITS USE. THE RECIPIENT ALSO UNDERSTANDS AND AGREES THAT RME, UPON RELEASE OF SUCH DATA, IS NO LONGER RESPONSIBLE FOR THEIR USE OR MODIFICATION. THE USER AND RECIPIENT OF THE ELECTRONIC DATA ACCEPTS FULL RESPONSIBILITY AND LIABILITY FOR ANY CONSEQUENCES ARISING OUT OF THEIR USE. From: Fred Paine [mailto:fred©klingeng.com] Sent: Thursday, October 30, 2008 2:05 PM To: Rabon A. Metcalf, P.E. Subject: Re: Water -Sewer Study Rabon, Based on our conversation last week regarding the Sanitary Sewer flowline for the Summit Crossing/ Crescent Pointe, I am proceeding with a revised design. I understand from our conversation that you can get to a flowline of 285.4 at the manhole location on the common line between Crescent Pointe and Summit Crossing. From your report, I determined that an 8" line installed at a 0.70% grade will accommodate peak flows from both Summit Crossing and Crescent Pointe Townhomes. The design will be altered to 'skew' the sewer line such that the end manhole is positioned approximately 50' to the north of the KES originally proposed location. Please acknowledge with a response as soon as possible. Best Regards, Fred Paine, P.E. KLING ENGINEERING & SURVEYING Consulting Engineers • Land Surveyors 4101 Texas Avenue, Suite A Bryan, Texas 77802 Telephone 979/846 -6212 Fax 979/846 -8252 Rabon A. Metcalf, P.E. wrote: Rabon A. Metcalf, P.E. ME C..crtsdrrny tryinrera file: / /C: \Documents and Settings \jnorton \Local Settings \Temp\XPgrpwise \4909DEF3City... 11/13/2008 CITY OF COLLEGE STATION Planning e7' Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM fiCf November 13, 2008 �� \ TO: DWS Development via fax 979.822.1763 FROM: Josh Norton, Engineering SUBJECT: Engineering Document Comments for Crescent Pointe Ph 4 BI 3 Lots 2 & 3 Final Plat (08- 500221) Staff reviewed the above - mentioned engineering documents as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review and approval of the plans: One (1) sets of revised construction documents. If you have any questions or need additional information, please call Josh Norton at 979.764.3570. Attachments: Staff review comments • pc: Emanuel Glockzin, Jr., Crescent Pointe Holdings, Inc., via fax 979.846.0783 Kling Engineering & Surveying, via fax 979.846.8252 is Case File No. #08- 500221 1`" ©�- ENGINEERING COMMENTS NO. 2 (Construction Documents) lease revise Sheet EC -1, to remove all private improvement from ROW. (Storm) Please illustrate use of structural backfill on profile for storm located in structural X7 reas. ST-2) Where is the plan / profile detail and erosion control effort for the storm connection to the detention pond after Junction Box J -2. (SS -3) Please label pipe size and material type of sanitary sewer main between Sta. +65 and Sta. 5 +00. SS -4) Sanitary Sewer Line "D" provide note to reconstruct manhole top to match roposed finished grade. i/ RN/V-1) There appears to be a blow -off missing at the stub located at Sta. 3 +72.39 7. (Water) Please verify a minimum of 4 -ft of cover is maintained throughout. Please submit site plan for private improvements. Reviewed by: Josh Norton Date: November 13, 2008 r 1 Planning & Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 2ITYof COLLEGE STATION Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 29, 2008 TO: DWS Development, via fax 979.822.176 I��I FROM: Lindsay Boyer, AICP, Senior Planner SUBJECT: CRESCENT POINTE PH 4 BL 3 LOTS 2 & 3 (FP - Final Plat Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. The application for this project was not complete at the September 15 deadline and therefore is not scheduled for the Oct. 16 Planning & Zoning Commission meeting. If all comments have been addressed and the following information submitted by Monday, October 6th, 10:00 a.m., your project will be placed on the next available Planning and Zoning Commission meeting scheduled on or after the meeting the preliminary plat makes. Complete application for a revised preliminary plat of Crescent Pointe Subdivision; One (1) 24 "x36" copy of the revised final plat; Nineteen (19) 11 "x17" copies of the revised final plat; Parkland Dedication in the amount of $42,300 must be submitted prior to the filing of the final plat; One (1) Mylar original of the revised final plat (required after P &Z approval); and One (1) copy of the digital file of the final plat on diskette or e-mail to mtrevino @cstx.gov. Upon receipt of the required documents for the Planning & Zoning meeting, your project will be considered formally filed with the City of College Station. Please note that if all comments have not been addressed your project will not be scheduled for a Planning & Zoning Commission meeting. Your project may be placed on a future agenda once all the revisions have been made and the appropriate fees paid. Once your item has been scheduled for the P &Z meeting, the agenda and staff report can be accessed at the following web site on Monday the week of the P &Z meeting. http://www.cstx.gov/home/index.asp?page=2481 Please note that a Mylar original of the revised final plat will be required after P &Z approval and prior to the filing of the plat. If you have any questions or need additional information, please call me at 979.764.3570. Attachments: Staff review comments cc: Emauel Glockzin, Jr., Crescent Pointe Holdings, Inc., via fax 979.846.0783 Kling Engineering & Surveying, via fax 979.846.82521 Case file #08- 00500221 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 5 9 ;o Z nna ,tau Ala ;aidwoo e a ;nmsuoo Minn 'APO ay; O ; ;nc,„ iiod ueaq jou aney ley; sueid asay; uo sa6ueqo leuoi ;ippe i(uy *sueld anon( uo „paiggnq„ pue Ja ; ;a' le ; ;iwsueJ; pcau mop( w paui idxa aq ;snw 'uoi ;eis e6epoo ;o A;iO ay; dq pa;senbai uaaq iou aney ;ey; 'sueid ay; o; spew sa6ueyo Auy :310N an!6 }snw ;uawasea 6u4s!xe ay} }o SJOUMO ay} ` ;uawasea a ;!s -}}o pasodoad sly} 6u!ddelaano s! ;u°wasee e6euleap 6ugs!xe ue se `uo!}lppe ul • }u°wna;su! eiwedas Aq pa}eo!pep aq }snw uo!}aod a ;!s -}}o au geld sly; y ;!M p° }eo!pap aq i(ew ;eld sly; }o spunoq pue sa}aw ay} u!y }!M pa;eool („ 8„ eaay uowwoo u!) 3fld g pasodoad ay} }o uowod ay} A1110 •9 •Ienoadde ueld a is Iln} 406 o} aapao u! Ala;e!peww! p° }noax° aq o} paau s ;uawasea a ;!s -}}o a en!ad II`d •9 •sNeem panes swle; ssaooad sly; se dySy sseooad sly} }ae ;s aseald •pa;d°ooe 6u!aq se! }!l! }n o!lgnd Aue o} loud p°}noaxa aq o} paau II!M }uawasea a ;!s -}}o ollgnd Hy 17 •Ilounoo nay} sseooad }uawuopuege lewao} ay} nay} auop aq o} paau pinoM }uawasea i( ;!ll ;n ollgnd e }o ;u°wuopuegy ;eld -aa ay} uo £ pue Z ;off ueeM ;aq }uawasea / pip o!lgnd }} -0£ ay} !agel aseald •£ geld ay} uo leg} a ;e }s aseald `aan }eu u! a}enud s! }uawasea a6eu!eap oyl eq} }I •Z •seaae ssaooe pue s }uawasea a}enud pue seam uowwoo jo sal ;!l!q!suodsaa aoueua;u!ew pue d!ysa°uMo ay} 6u! }e ;s }eld ay} uo a}ou e ap!noad aseald • 6 (s ;uewwoa ;eld IeU13) 6 'ON S1N3WWO3 ON12133NION3 8002 '6Z Jegwe deS :a }ea aauueld ao!uas `JeAo8 i(espull :Aq p°Ma!Ae •Ma!naa MaU Ala }aldwoo a a ;n;! }suoo II!M }o alarms °pew uaaq ;ou seq Apo ay} }ey} sueld asay} uo sa6ueyo leuo! ;!ppe i(uy *sueld anoi( uo „palggnq„ pue aa; ;al le ;;!wsuea} }xau anon( u! peu!eldx° eq }snw `uo! }e ;S abalioa }o Apo ay} Aq pa }senbaa uaaq ;ou aney }ey} `sueld ay} o} spew se6ueqo Aue ;ey} a ;ou aseald £ L ;o! pea jo 96e }oo} °aenbs ay} ap!noad Z < geld sly} y ;!M paa!nbaa s! uo! }oauuoo )lleMap!s ay} 4o uo!;oas awe ay} }o uo!;on4suO3 •6 1, geld fueu!w!laad ay} y }!M eoue!ldwoo w Apadoad sly} g6noay} uo!s!n!pgns 6u!ssoaa ;!wwnS ay} WOa} °pew 6u!aq s! uo!;oeuuoo ){IeMap!s Moy 6u!I!e }ap a;ou ap!noad '06 •£ }off uo ;snf s;ol 91.11 .104 uo!}elnoleo A}!suap ;au a ap!Awd •6 geld i(aeu!w!laad ay} y ;!M uo! }ewao }u! y }6ual >{oolq ap!noad •9 abed }sal} ay} uo Noolq al }!} ay} u! uo!;ewa0 }u! aap!n!pgns .10 JOUMO ap!noad •L „uoisln!pgns a ;u!od ;uaosaa3 £ Nool9 '£ pue Z s;o }o }eldaa e 6u!aq uo!s!n!pgn9 a}u!od }Uaosea3 £ Noola `zi7-c-jz s}ol }o }eld Ieu!d„ peal o} sjoolq al }!} ay} OSIAOJ aseald •9 geld fueu!w!laad ay} y }!M aoue!aen a ;sanbaa aseald `pap!noad aq o} ;ou ale Aegll }! `s }ol Ile }o aeaa ay} ;e paa!nbaa ale s}u°wese3 A}!l! }n o!Ignd •5 •s }ol asay} sleld osie leg; }eld e ap!noad JO s;ol asay} epnlou! o} OS1A9J aseald •s ;ol pa }}eld uo eq }snw 0£ HS 01 ;uawasea ssaooe ay; 6ulueaw `s;ol pa;;eld uo aoeld °){e} ;snw uo!;ona;suo3 j7 •uoi ;eo!p °p pue d!ysaauMo ao} 0480!411ao ay; se IIaM se s°}eo! }!}aao xe; ay; page osle II!M s!yl •pap!noad pue pagpe!o aq pinoys (u6!s o} 4uoy }ne }o paid 6u!poddns pue) uo!;ewao ;u! sly} `°an;eu6!s s,a°uMO ue spaau ;eld mug ay; awl} 9(44 i(q ipadoad ay; UMO II!M SMCI 41 Z'2d ay1 o} o6 Aew ;! aao}aq p°a!nb °a s! Auedwoo ay; }o }leyaq uo u6!s o} an! }e }uasaadaa SMa ay} ao} A}!aoy}ne ay; geld ay; 6u!u6!s aq II!M }uawdolenea SMa }I £ •Al!we}!}InI'I j7 - d pauoz s! i(padoid sly; win Moys 04 uo!;eolldde ay} °Slnaa aseald •Z geld kaeu!w!lead pes!naa a ao4 uo!;eo!Idde ue ;!wgns aseald • 6 ONINNV1d (1ZZ00900 - dd) £'8 Z S1Ol £ 18 j7 Hd 31NIOd 1N3OS3210 :;oa(oad 1 'ON S1N3WWO3 M3IA321 33b1S the city first right of refusal before the city could process this proposed off -site PUE dedication. 7. Please verify that all rear lot lines have been provided a 20 -ft PUE. 8. It appears that you are proposing to abandon a portion of the existing cul -de -sac ROW. Abandonment of public ROW must be done thru the easement abandonment application process, which must be approved by council. 9. Please dedicate the northeast property corner area which is currently depicted as ROW as Common Area, the city does not want to maintain this area. Reviewed by: Josh Norton Date: September 29, 2008 ENGINEERING COMMENTS NO. 1 (Construction Document Comments) 1. Please submit a new development permit application and associated fees for this development. The previous development permit was issued for the spoil piles. 2. Please remove all private improvements from the ROW, with the exception of residential and commercial driveway aprons. 3. Since the proposed fire access road is permanent in nature, as it will serve future commercial development along SH 30 the construction material type need to be either asphalt or concrete and meet the minimum site design standards for commercial development. 4. Please adjust the curb return radius on the fire access road. 5. Please illustrate the gate on each end of the fire access road. 6. Please illustrate the use of structural backfill in all areas where public utilities are proposed under paving. 7. Please demonstrate and provide details for the appropriate positive drainage for the knuckle street design. There have been issues in the past with these designs, as water has a tendency to pond in these areas. 8. The storm sewer plans do not appear to illustrate the storm connection to the detention pond near the southwest property corner. 9. (Sanitary Sewer) Any location where there is less than 3.5 -ft of cover require ductile iron and cement stabilized backfill. 10. (Sanitary Sewer) For the aerial crossing please note the use of MJ bells with retaining glands, which should be located at the piers. 11. (Sanitary Sewer) Please provide and make reference to the BCS Unified Guidelines, Specs and Detail for the construction of this sewer main extension. 12. (Sanitary Sewer) Please verify design with BCS Unified Guidelines, Specs and Detail. Detail S4 -00 illustrates piers as needing to be a min. of 6 -ft below grade. 13. (Sanitary Sewer) Any mains under future pavement areas (Access Easements) need to meet the city's structural backfill requirements. 14. (Sanitary Sewer) As you know the adjacent property to the east has previously submitted construction documents for development, including a study of this sewer shed. Would it be possible to lower Sanitary Sewer Line "B ", where the manhole at Sta. 4 +92.27 is closer to a flow line of 284? It appears that a reasonable bury and appropriate slope could still be achieved with this constraint. Obviously there is probably some room for adjustment, and you may contact the engineer from the adjacent development (Rabon Metcalf: 690 -0329) in order to coordinate this effort. 15. (Sanitary Sewer) Please illustrate min. TCEQ requirements at water /sewer conflicts where applicable. 16. (Sanitary Sewer) On Line "B" where is the storm conflict in profile. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 5 ION g ;o ti 'Altai,,. ■au Aia;aIdwoo a a ;n ;i;suoo pinn 'AID ay; o;;no,.iod uaaq ;ou aney ;ey; sued esay; uo sa6ueyo ieuoi;ippe /uy . sueid anon( uo „paiggnq„ pue Ja ; ;ei lemwsuei;;xau Jnoi( ui pauieldxe eq ;snw 'uoi ;e ;g a6alloo Jo Ain ay; /q pa;senbai uaaq ;ou aney ;ey; 'sued ay; o; spew sa6ueyo i(uy :310N "800Z `g gawky uo 46!up!w le aa!dxe //!M i!wJed leaauab aelno!ped slgl "peMolloJ aae'lwied lereue5 slgl jo s'uewaa!nber eqj se Buol se— uo!'do slgl iapun peiinbe r s! eej JO `(ioN) uo!'eu!upel jo eo!'ou `(ION)'uelu! jo eogou oN eleM w.rols ofiregoslp o' pezuoglne aae no/f `pwied le eua6 situ jo suolllpuoo eq.; mew noA se 6uol sy eleM waols'Jodsueal ,JO poelloo of pesn Jo peub►sep peuMo ko!lgnd s! Jegl esje Bu!gplue JO mpg) `saalln6 `slauuego `sjeaa's epnlou! SfSW y "pediegos!p eq ll!M aaleM WJOJS go!gM op! (l s v) walsAs James JeleM wJo's eleredeS ledio!unlnl Aue jo aoleiedo eqj o' eollou ells eql Jo Woo e epinoad `uogonalsuoo 6u!uu!fieq eiojeq s/(ep Z'see! l y "g "eogou ells uo!lonalsuoo e'sod pue u5ls "ti "(0000g62JXl)'!w.red leieue5 eqj JO 111 ped gllM eouepi000e u! ueld uolluenaad uollnllod aaleM waols a lueweldw! pue eredeid "£ '(OOOOg L IX1) Pulled leaauab eqj jo sluewaa!nbe r eta 0' a regp y "Z uo!lenl!sano/f of sa!/dde l! awns wlew o (0000gt2JXl)1!w.ied leaauab eqj peal "k :(tiSW) weJsAs James JeleM two's ejeredes ledlo!unp' s,uo!'e's e6allo0 jo Al!o ow 01 ells uo!lonalsuoo Jno/f way aaleM Willis eBaegos!p o' sdals esegl Molloj of peeu ll!M noA "saaoe g uegl ssei lnq k 'see! le 6uigin'sip luewdo/enep jo ueld uowwoo e Do ped s! JO seioe g ueg'ssej jnq i'seej le fiulgan'sip sellln!loe uollofJlsuoo aoJ s! (00009kelX1) llwied leaauab eqj *walsAs uolleu!w!13 ediegos►Q uollnllod sexej egl.repun se!'!nlloe uogona'suoo Joj llwied leaauab e penss! seq /Went) leluewuoa!nud uo uoiss!wwo0 sexej eqj sail!n!lo y cro!lonalsuoQ pews way sediegos!Q aaleM w.JO'S :9L£9 le `Jo;oedsul a6eu!e.aa 3000 's!II!M a!uuoa o} pa ;oaa!p eq i(ew suogsenb i(ue `sMollo} se aae s;uewei!nbei ;uawe6euew Ja;eM wao ;S "S000 ay; o} pap!noad i(doo e pue awls ay} y ;!nn pal!} aq ;snw ION e ;oefoad sly} }o uo! ;onJ;suoo 6ulanp pegan;slp eq Il!M same g uey; aaow }! 's;uewwoo paepue ;s 6uIMollo} ay; o; uol ;lppe ul "11-008 /Jana amen a ;e6 a s! away; / }!Jan aseald (Ja;eM) "£Z "al! }ad u! semen a ;e6 Ile legel aseald (JaleM) "ZZ "saxoq WJO ;s o; asop aJe su!ew ay; aaaynn suogeool u! ;noy6noiy; uo!;eaedas leuo!pppe ep!noJd aseald (JaleM) • 6Z "padolanap s! ;! aouo wa;sAs Ja;eM sly; o; dool i(ew i(padoJd sly; os ` ;sea ay; o; I(}Jadad ;ueoefpe ay; o; a6p!H a;u!od ;ueosaa0 ssoJoe ;no qn ;s au!! Ja;enn a ap!noJd aseald 'ow "pea ssaooe aJi} pesodoid ay; 6uoie pays!ldw000e eq Aew s!Lo `0£ HS 6uole wa;si(s Ja ;enn ay; o; UO11O3UUO3 a ap!noad aseald •swa;sAs Ja ;eM Jay ;o i(ue o ; ;oauuoo ;ou saop ;! se „pedool„ paaap!suoo ;ou s! wa;si(s Ja;eM pasodoJd ayl (Ja;eM) 'OZ "aoueua ;u!ew aan ;n} Jo} wool yonw iou s! away; `saxoq wao ;s pesodoad pue u!ew ay; uaann;aq uo!;ejedes leuo! ;lppe ep!noJd o; alglssod eq ;! mom „0„ eu!l up (Jamas AJe;!ueS) "6l "al! }oad u! ;o!l}uoo wao ;s ay; s! OJaynn „0„ au!l up (Jamas fue;!ue3) "g "eoueua;u!ew aan ;n} Jo} wool yonw ;ou s! aJay; `saxoq wao ;s pasodad pue u!ew ay; uaann;aq uo! ;eJedes leuo!;!ppe ep!noJd o; alq!ssod eq 1! mom „a, aull up (Jamas i(Je;!ueS) "LL. A copy of General Permit TXR150000 can be obtained from TCEQ at: http /www. tceq. state. tx. us/ assets / public /permitting/waterquality/ attachments /stormwater /txr150000. pdf A copy of the construction site notice can be obtained from TCEQ at: http /www. tceq. state. tx. uslassets/public/ permitting /waterquality/ attachments /stormwater /txr152d2. pdf Reviewed by: Josh Norton Date: September 29, 2008 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION 1. Developer provides temporary blanket easement for construction purposes or provides descriptive easements for electric infrastructure as designed by CSU for electric lines (where applicable, including street lights). 2. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. 3. If applicable, the following easements will be required: ➢ A 5' PUE in Lot 3, common areas 2,4,8, & 9 ➢ A 10' PUE along the western property line from Crescent Pointe Pkwy around common area A continuing to the North property line running adjacent to the park dedication lot. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. 2. CSU will provide drawings for electrical installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser. 4. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 5. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 7. Developer installs pull boxes and secondary pedestals per CSU specs and design (pull boxes and secondary pedestals provided by CSU). 8. Developer provides digital AutoCAD 2000 or later version of plat and /or site plan. Email to: sweido @cstx.gov. 9. Developer provides Toad data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 10. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 11. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 9 -24 -08 SANITATION 1. Need to show type of garbage collection service for this site. Reviewed by: Wally Urrutia Date: September 24, 2008 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. 5 of 5 CITY OF COI .I RGE STATION Planning d Development Services. 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM September 15, 2008 TO: DWS Development via fax 979.822.1763 ✓ FROM: Molly Hitchcock, AICP (',1 l\ I�cj Planning Administrator ' SUBJECT: CRESCENT POINTE PH 4 BL 3 LOTS 2 & 3 (FP - Final Plat) I reviewed the above - mentioned final plat application and determined it to be incomplete. The following is a preliminary list of items needed to complete the submittal so that staff may conduct a thorough review. Please submit the following information to be scheduled for a future Planning & Zoning Commission meeting: A complete application on an updated form. The application form was updated earlier in the summer to reflect the requirement that the property owner has to sign the application. All questions should be completed with the appropriate information or "N /A ". Also, the zoning of the property is R -4 Multifamily. As this is a single - family plat, parkland dedication will be required at time of plat. Please update this information on the application and provide proof of approval from the Parks Department. The tax certificates show Crescent Pointe Ltd. to be the property owner, not DWS Development. If DWS will own the property by the time the final plat needs an owner's signature, this information (and supporting proof of authority to sign) should be clarified and provided. As the property owner is a business, the application will need to be accompanied by proof of authority for the individual to sign on behalf of the company. If you have any questions or need additional information, please all me at 979.764.3570. cc: Kling Engineering & Surveying via fax 979.846.8252 Case file #08- 00500221 PRELIMINARY PLAT STAFF REVIEW COMMENTS NO. 1 Project: CRESCENT POINTE PH. 4 (PP) - 08- 00500257 PLANNING (Preliminary Plat) 1. Please update the title page index sheet (looks like it was used for a replat of phase 2, at one time). 2. Please revise zoning to reflect existing A -P zoning line. Please also indicate the proposed zoning for that area. 3. The volume & page of all easements will need to be provided on the mylar (whether by separate instrument or plat). The City will need first right of refusal of the off -site easement in Common Areas A & B. 4. Please provide lot dimensions on all Tots, including townhome and A -P lots in phase 4. 5. The net density of the townhomes is 48 units on 4.15 acres, or 11.8 du /ac. Please indicate this by way of a note on the plat. 6. The preliminary plat and final plat for phase 4 need to be consistent. Make any necessary changes (ie: easement locations on lots, street right -of -way at previous cul -de -sac, etc.). 7. All sidewalks and utilities should be shown. Related specifically to Phase 4, sidewalks are required on Crescent Pointe Parkway and on Crescent Ridge Drive. Reviewed by: Jennifer Prochazka Date: October 28, 2008 ENGINEERING COMMENTS NO. 1 (Preliminary Plat) 1. Please illustrate all requires infrastructure on this preliminary plat (ie. water, sanitary sewer, storm sewer, sidewalks, etc). 2. Please provide all surveying calls, as it appears several side lot line calls are missing. 3. Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION (preliminary Plat 1. Most easements on site are existing. Electric facilities will be designed within existing easements where possible. 2. Developer provides temporary blanket easement for construction purposes or provides descriptive easements for electric infrastructure as designed by CSU for electric lines. 3. Developer may be responsible for locating easements on site to insure that electrical infrastructure is installed within easement boundaries. 4. If applicable, the following easements will be required: ➢ A 20' PUE between Lots 5R & 7R Block 1. GENERAL ELECTRICAL COMMENTS 1. Developer installs conduit per CSU specs and design. Home of Texas A &M University 2. CSU will provide drawings for electrical installation. 3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser. 4. Developer will intercept existing conduit at designated transformers or other existing devices and extend as required. 5. If conduit does not exist at designated transformer or other existing devices, developer will furnish and install conduit as shown on CSU electrical layout. 6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc) per CSU specs and design. 7. Developer installs pull boxes per CSU specs and design (pull boxes provided by CSU). 8. Developer provides digital AutoCAD 2000 or later version of plat and /or site plan. Email to: sweido @cstx.gov. 9. Developer provides load data to CSU as soon as it is available to avoid construction delays. Delivery time for transformers not in stock is approximately 40 weeks. 10. Final site plan must show all proposed electrical facilities necessary to provide electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and conduit routing as designed by CSU. 11. To discuss any of the above electrical comments please contact Sam Weido at 979.764.6314. Reviewed by: Sam Weido Date: 10 -21 -08 SANITATION (preliminary plat) 1. Need to discuss what type of garbage service they will be requesting in order to determine level of service. Reviewed by: Wally Urrutia Date: October 16, 2008 FINAL PLAT STAFF REVIEW COMMENTS NO. 2 Project: CRESCENT POINTE PH 4 BL3 LOTS2 & 3 (FP -R - 08- 00500221 PLANNING (final plat) . Application should be amended to include the number of A -P lots, as is currently zoned. 2. Since the plat also includes property that has never been previously platted, the title of the plat should say "including a replat of' instead of "being a replat of." Please include the total number of lots being platted and the total acreage to the title block. 4, Label original plat as "Original Plat." 5. Label new plat as "Replat and Final Plat." 6. C.A. #1 should be "shaded" on the drawing as other common areas are and as the legend indicates. Home of Texas A &M University ,, 7. The volume and page of all easements will need to be provided on the mylar (either by separate instrument or plat). The City will need first right of refusal of the off -site easement in Common Areas A & B. 8. Please provide lot dimensions on all lots (specifically, the lot lengths are missing from some lots). 9." The net density of the townhomes is 49 units on 4.15 acres, or 11.8 du /ac. Please revise note number 6. 10. A note should be added to indicate current zoning. 11 A note should be added referencing the Administrative Adjustment that will be approved •I for the lot depth of the A -P lots (write the note as if it already has been). Reviewed by: Jennifer Prochazka Date: October 28, 2008 ..r ENGINEERING COMMENTS NO. 2 (Final Plat) 1. Please provide all surveying calls, as it appears several side lot line calls are missing. 2. The modifications to the cul -de -sac are illustrated differently between the preliminary and final plat. 4 3. On Sheet 3, the existing PUE at the rear of CA # 3, 4, 5, 6, 7 does not appear. A. On Sheet 3, the existing PUE along the side of CA # 7 does not appear. ; 5." Please verify that any portion of cul -de -sac ROW that currently cover public utilities that is proposed to abandoned is replaced with PUE and labeled appropriately. Reviewed by: Josh Norton Date: October 29, 2008 Home of Texas A &M University