Loading...
HomeMy WebLinkAboutStaff Comments (ff.„„41,41 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570/ Fax 979.764.3496 CITY OF COLLEGE STATION MEMORANDUM August 18, 2008 TO: Mark Robinson, Robinson Custom Homes, via fax 690 -1425 FROM: Jason Schubert, AICP, Staff Planner SUBJECT: AGGIE PET ZONE (SP) — Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Cover memo providing written responses to all of staff's comments (identify the specific page that each comment was addressed on or the reason for not addressing the comment); Two (2) revised site/ landscaping plan (if all items have been addressed, Staff will ask for additional copies for approval /stamping). If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please contact me at 979.764.3570. Attachments: Staff review comments pc: Joseph & Dorothy Mikeska, owners, via idmikeskaCc�gmail.com Harry Bostic and Steve Musser, via bruce @mmdesion.tx.com Case file #08- 00500183 STAFF REVIEW COMMENTS NO. 1 Project: AGGIE PET ZONE (SP) — 08- 00500183 PLANNING 1. Please add the date of submittal and applicant, owner, architect contact information to the site plan as permanent notation. 2. Please change the use in the parking calculations from office to veterinary clinic, which has a different parking ratio. 3. Please clarify the acreage for the site in the legal description such that 2.03 acres does not to be 2.03 acres of Lot 7R. 4. Please revise the City limit line to accurately reflect the areas annexed in March. 5. Please show the boundary between Lot 2R and the portion of Lot 7R not being developed. 6. Please remove the label on the site plan that states Lot 7R is not currently in the City limits. This portion of Lot 7R is in the process of being annexed. 7. Please provide volume and page for the existing joint access easements. From the plat, it appears the western joint access easement runs along Rock Prairie Road West, not just a 40 -foot by 40 -foot box. Also, it appears that the "joint" is incorrectly spelled. 8. Since the dumpster faces right -of -way, please provide gates to the dumpster enclosure. 9. Please note that the interior dimensions of a dumpster enclosure (inside of gates, bollards, etc) for one dumpster may be a minimum of 12 feet in width and 12 feet in depth. 10. Provide a general note that all roof and ground- mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right -of -way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. 11. Please note that any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that the City has not be made of aware of will constitute a completely new review. Reviewed by: Jason Schubert Date: August 18, 2008 LANDSCAPING /STREETSCAPING /BUFFER 1. There appears to be only 16 Live Oaks depicted on the plan, not 17 as listed in the table. Also, there appears to be 3 different sizes of Live Oaks on the plan while only 2 sizes are identified in the legend. Please reconcile. 2. In the landscape calculations, please state the number of streetscape trees that are required and how many have been provided. 3. The shrubs proposed to screen the parking areas are not adequate in number as one shrub is required for every 3 linear feet. Please revise. FYI, there may be gaps in the planting of the shrubs where the tree crepe myrtles are proposed. 4. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock (not loose), or a perennial grass is required in parking lot islands, swales and drainage areas, the parking lot setback, rights -of -way, and adjacent property disturbed during construction. Reviewed by: Jason Schubert Date: August 18, 2008 ENGINEERING COMMENTS NO. 1 1. Please show and label the proposed water service lines. 2. Please show the domestic and irrigation meters. As a reminder, both meters are required to be within the PUE however service lines must be outside the PUE. 3. Please add a note stating that Wellborn Special Utility District will be providing water service to the property. 4. Please submit a fire flow report signed and sealed by a professional engineer. The report should verify that the system meets minimum requirements and utilize actual flow data (see "Domestic Water" chapter of the B /CS Unified Design Guideline Manual). 5. Please label the building size, material, and whether or not it will be sprinkled. 6. Please add note stating that the property will be served by an On -Site Sewage Facility (OSSF). 7. FYI ... Please note the following steps in obtaining septic service. The site plan cannot be approved until a Letter of Authorization to Construct has been issued by the Brazos County Health Department. - Developer submits Building Plans and Site Plans to City to review including lot size is a minimum of 1 acre outside of floodplain and general floodplain requirements - City to issue Floodplain Letter to Brazos County Health Dept acknowledging if layout is acceptable - Developer to submit septic plans with Floodplain Letter and Soil and Site Evaluation to Brazos County Health Department - Health Department issues an Authorization to Construct (ATC) the septic system to Developer - Developer submits ATC to City - City approves Site Plan and issues Building Permit 8. The driveways must be designed to City standards for commercial driveways (see detail ST2 -03). Please note that your driveway construction will vary slightly with culverts rather than sidewalks (see detail ST2 -02). Please include a detail with the plans showing driveway construction with culverts. 9. Please label radii, dimensions, and culvert sizes on the driveways. 10. According to the plat, there should be a 20 -ft PUE centered on the lot line between Lots 6R and 7R. Please show this PUE on the plans or provide documentation that this easement has been abandoned. 11. The plat shows a 10 -ft PUE along the back of Lot 7R, but the site plan is showing the PUE crossing through the lot. Please clarify. Reviewed by: Erika Bridges Date: August 18, 2008 ELECTRICAL 1. This plat is outside the College Station Utility electric service area. Customer will have to get with their electric supplier for this area to determine electric service specifications and requirements. Reviewed by: Timothy Crabb, CSU Electric, (979) 764 -3439. Date: August 12, 2008 FIRE 1. Looks good no comments. Reviewed by: Steve Smith Date: August 15, 2008 SANITATION 1. Sanitation is okay with this project. Reviewed by: Wally Urrutia / Rodney Harris Date: August 13, 2008 Joseph A. Mikeska., D.V.M. & Dorothy T. Mikeska, D.V.M. 3212 North Graham Road College Station, Texas 77845 979- 764 -0904 Memorandum September 2.5, 2008 To: Jason Schubert, AICP, Staff Planner From: Joseph and Dorothy Mikeska SUBJECT: AGG1E PET ZONE SITE PLAN- Second Submission Response to Stab' Review Comments on First Site Plan Submittal Responses to Planning Comments Comment # 1, Page 2 Required information has been included on the site plan in the block titled "Information ". Comment #2, Page 2- "011ice building" has been replaced with "veterinary clinic ". Comment #3, Page 2 -The legal description now shows the acreage for Lot 6R and the acreage for the portion of Lot 7R that is being utilized in the project. Comment #4, Page 2 -City limit lines are shown and identified. Comment #5, Page2- Requested boundary is now shown. Comment # 6, Page 2 -The label has been removed. Comment # 7, Page 2 -The volume and page have been placed on plan. The western joint access easement has been lengthened, showing that it is not limited to the dimension of 40' by 40'. Comment # 8, Page 2 -Gates have been added to dumpster enclosure. Comment # 9, Page 2- Width of dumpster is shown as fifteen feet. Comment # 10, Page 2- General note has been placed on the plan a ( General Note number 0.5). Responses to Landscaping /Streetscaping/Bu#fer Comments N-N?) ('i, Comment #1, Page 2- Reconciled number of plants listed in legend with plants depicted. Comment #2, Page2-Streetscape requirement and number provided has been placed in legend. Comment #3, Page2- Quantity of streetscape shrubs has been revised. Comment #4, Page 2- General note has been included on the plan as General Note number 06. Responses to Engineering Comments No. 1 Comment #1, Page 3- Proposed water service line is shown. Comment # 2, Page 3- Domestic and irrigation water meters are shown.. Comment # 3, Page 3 -Note added to plan as General Note Number 10. Comment #4, Page 3 -Fire tlow report, along with letter describing construction breakdown of the proposed building is included. Comment #5, Page 3- Information provided in block titled "Building Information ". Comment #6, Page3- The owners plan to construct an 8" gravity line within the public utility easement along Rock Prairie Road. Greg Taggart, of Adams, Taggart and Associates has conducted a study of the site and prepared construction plans for the 8" sewer line. Application has been submitted to the City of College Station. The proposed sewer line and sewer service lines are represented on the site plan. Comment #7,Page3 -See response to comment # 6. Comment #8, Page 3- Drawing ST2 -02 from Bryan - College Station Standard Street Details, depicting details of construction of driveways built over culverts, has been included on the plan. Comment #9, Page 3- Requested information has been placed on the plan. Comment # 10, Page 3 -The 20 foot wide PUE centered on the lot line between Lots 6R and 7R has been drawn on the plan. Owners have submitted a completed request for abandonment of this easement (on September 25, 2008). Comment # 1 1 , Page 3 -The PUE shown crossing the lot was drawn in error. It has been removed from the plan. Response to Electrical Comments Comment # 1, Page 4- Customer is working with BTUtilities on electric service issues. Fire and Sanitation raised no issues. ' ���1 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 CITY OF COLLEGE STATION MEMORANDUM October 13, 2008 TO: Mark Robinson, Robinson Custom Homes, via fax 690 -1425 FROM: Jason Schubert, AICP, Staff Planner SUBJECT: AGGIE PET ZONE (SP) — Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $200 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Seven (7) complete sets of construction documents for the proposed development with the revised site /landscaping plans attached (one set will be returned to you, please submit additional copies if you want more than one approved set) Three (3) revised site /landscaping plans One (1) 11x17 grading and erosion control plan If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Joseph & Dorothy Mikeska, owners, via jdmikeska(a4mail.com Harry Bostic and Steve Musser, M -M Design, via fax 694 -7029 Case file #08- 00500183 STAFF REVIEW COMMENTS NO. 2 Project: AGGIE PET ZONE (SP) - 08- 00500183 PLANNING 1. Please note that the building elevations under the Non - Residential Architecture Standard (file 08 -182) have been approved. 2. I have no further comments regarding the site /landscape plan. Reviewed by: Jason Schubert Date: October 13, 2008 ENGINEERING COMMENTS NO. 2 1. The proposed water service lines (domestic and irrigation), existing water main, and proposed sanitary service lines should be labeled with size and material type. 2. Please label the sanitary sewer service line slope on the site plan. Please see the Unified Design Guidelines for minimum slope based on line size. 3. Based on the current scale, it is difficult to see what is going on in the area where the domestic water service line, irrigation line, and fire hydrant are tying into the public main. Please provide a larger detail of that area. 4. It appears that you are proposing boring Rock Prairie Rd. with a new waterline. If this is the case, an engineer sealed plan and profile drawing will be required for the public waterline extension. Would it be possible to utilize the existing waterline (that was put in place for the fire hydrant) to serve the property's domestic water and irrigation needs? 5. In the previous submittal, a waterline was shown crossing Rock Prairie Rd. to serve the fire hydrant at your property. I noticed that waterline is either not shown this time or is being shown in a different location. Please clarify. 6. Fire Flow — As discussed in our phone conversations, the City's fire flow requirements are currently not being met based on the International Fire Code. Based on the given information regarding the construction type, two fire hydrants will be required to service the development. FYI ... The local fire ordinance permits a 50% reduction in the required fire flow for buildings that utilize a fire suppression sprinkler system. 7. Fire Flow — Please provide a copy of the actual fire hydrant flow test data from Wellborn SUD. The previously submitted fire flow letter from Mr. Fontaine should be based on the actual data acquired from testing the fire hydrant. 8. FYI ... The plans for the sanitary sewer extension should be approved prior to site plan approval. 9. FYI ... The public utility easement abandonment is scheduled to be heard by City Council on November 24, 2008. Construction within that easement cannot occur until the easement has been abandoned. Reviewed by: Erika Bridges Date: October 13, 2008 0%11q ib Joseph A. Mikeska, D.V.M. & Dorothy T. Mikeska, D.V.M. ^ � 3212 North Graham Road C� /J College Station, Texas 77845 979-764-0904; 979 - 575 -2543 Memorandum October 26, 2008 To: Jason Schubert, AICP From: Joseph & Dorothy Mikeska Re: Response to Staff Review Comments No. 2 (Aggie Pet Zone) Eight copies of the revised Site Plan have been included in this Submittal per communication from Mr. Schubert. Provisions for erosion control have been added to the sewer plan per instructions from Engineering Staff. A copy of reporting from Mr. Fontaine, regarding fire flow issues, has been included. PLANNING No comments were present in Staff Review Comments No. 2. ENGINEERING COMMENTS NO. 2 Response to Comment 1: The respective sizes and material types of the proposed water and sanitary service lines and existing water main have been placed on the plan in the block titled "Water Detail ". Response to Comment 2: Sanitary sewer service line has been labeled with minimum allowable slope for 4 "line. Response to Comment 3: Details of the water system are depicted in the drawing titled "Water Detail ". Response to Comment 4: The owners are not proposing to bore Rock Prairie Road for a new waterline. The waterline shown crossing Rock Prairie Road in a road bore is the existing water main, not a proposed water line. This issue is hopefully clarified in Response to Comment 5. Response to Comment 5: The waterline to which you refer, (in the Site Plan Sealed by Mr. Bostic on 7- 16 -08) was apparently a drafting oversight. There is not a waterline in that location. In preliminary planning, it may have been drawn in that location as a proposed location prior to actual construction of the waterline, and was placed on the earlier plan as a result of a communication failure. The true location of the waterline has been correctly depicted in the Site Plan included in this submittal and in the Site Plan previously submitted (Sealed by Mr. Bostic on 9- 23 -08). Response to Comment 6: The Fire Flow issue has apparently been resolved and the minimum required Fire Flow seems to be available. Response to Comment 7: The communications regarding fire flow, from Mr. Fontaine are included in this submittal. Response to Comment 8: Plans for the sanitary sewer extension have been approved. Response to Comment 9: We understand the intent of this comment and will comply. Thank you. Joseph A. Mikeska, D.V.M., PhD October 27, 2008