Loading...
HomeMy WebLinkAboutCORRESPONDENCEANOW Glenn Jones PE #97600 Eng ineefi ng J4 CFM Firm #9951 Consulting • Engineering • Construction Services PO Box 5192 Bryan, Texas 77805 Phone: 979 - 739 -0567 Fax: 979- 774 -5025 gjones@ j4engineering.com June 6, 2013 Erika Bridges, EIT Staff Engineer City of College Station PO Box 9960 College Station, Texas 77842 RE: Letter Acknowledging City Standards Plantation Oaks Addition, College Station, Texas Ms. Bridges: The purpose of this letter is to acknowledge that the construction plans for sewer improvements related to the above referenced project, to the best of my knowledge, do not deviate from the BCS Design Guideline Manual. Any alternate design or construction methodology that was used is listed below: 1. The minimum design grade for sewer mains was reduced to meet TCEQ's minimum grades. I also acknowledge, to the best of my knowledge, that the details provided in the construction plans are in accordance with the BCS Standard Details. lenn Jones, PE -CFM - %N %X �1 OF 7-E -* or *, _.* j GLENN J04ES 97 , � , r �O� SIC �� •• �c�� r "Aggie Owned and Operated" -Page I of I- SMALL CONSTRUCTION SITE NOTICE FOR THE Texas Commission on Environmental Quality (TCEQ) Storm Water Program TPDES GENERAL PERMIT TXR150000 The following information is posted in compliance with Part II.E.2. of the TCEQ General Permit Number TXR150000 for discharges of storm water runoff from small construction sites. Additional information regarding the TCEQ storm water permit program may be found on the internet at: http: / /www.tceq.state.tx.us /nav /permits /wq construction.html Operator Name: Miles Construction Corp. r � SMALL CONSTRUCTION SITE NOTICE FOR THE Texas Commission on Environmental Quality (TCEQ) Storm Water Program TPDES GENERAL PERMIT TXR150000 The following information is posted in compliance with Part II.E.2. of the TCEQ General Permit Number TXR150000 for discharges of storm water runoff from small construction sites. Additional information regarding the TCEQ storm water permit program may be found on the internet at: http: / /www.tceq.state.tx.us /nav /permits /wq construction.html Operator Name: Miles Construction Corp. Contact Name and Phone Number: Bo Miles: (979) 777 -4675 Name: E. Rudder @ University Oaks Business Office Project Description: Physical address or Location: description of the site's location, estimated start Northwest corner of E Rudder Freeway Frontage Road date and projected end date, or date that disturbed and University Oaks - College Station, TX soils will be stabilized Estimated Start Date: September 1, 2013 Location of Storm Water Pollution Prevention Plan: Mile Construction Corp. Job Site Trailer/ Site Superintendent's Truck For Small Construction Activities Authorized Under Part II.E.2. (Obtaining Authorization to Discharge) the following certification must be completed: I Bo Miles (Typed or Printed Name Person Completing This Certification) certify under penalty of law that I have read and understand the eligibility requirements for claiming an authorization under Part II.E.2. of TPDES General Permit TXR150000 and agree to comply with the terms of this permit. A storm water pollution prevention plan has been developed and will be implemented prior to construction, according to permit requirements. A copy of this signed notice is supplied to the operator of the MS4 if discharges enter an MS4. I am aware there are significant penalties for providing false informat1on tst�r conducting thorized discharges, including the possibility of fine and imprisonment for knowing violations. ' �r Signature and Title Date Date Notice Removed MS4 operator notified per Part H. F. 3. TRANSMITTAL �Fj Ing ineeiin g J4 Consulting • Engineering • Construction Services PO Box 5192 Bryan, Texas 77805 (C)979- 739 -0567 (F)979- 774 -5025 From the Desk of: Glenn Jones, PE -CFM Principle Engineer/ Owner Email: giones@i4engineering.com To: Morgan Hester With: City of College Station Phone: 979 - 764 -3445 Fax: 979 - 764 -6258 RE: Case file No. 13- 00900098: Resubmittal Date: June 3, 2013 Notes: i��CalD�(�3 Attached are the revisions to the Development Plat and Sewer Improvements Plan for Plantation Oaks Addition that you requested in your letters dated June 3 & 4, 2013. The requested number of copies is enclosed and is hereby resubmittal for review and approval. The following is a summary of the items address: • The certification for the owner has been revised, as requested. • The existing and proposed utilities have been removed from the plat. • The stationing for the proposed manhole has been corrected. • The proposed service line has been shortened to keep the CO within the ROW. • Note #4 has been changed to show that the road crossing for the service line will be by open -cut method. • Standard City Details have been added to the plans. • Erosion control and traffic control details have been added to the plans. • NOI and Letter of Acknowledgement are attached. • Plans are signed, sealed, and issued for construction. Thank You. TRANSMITTAL * '' Ingineeiing J4 Consulting • Engineering • Construction Services PO Box 5192 Bryan, Texas 77805 (C)979- 739 -0567 (F)979- 774 -5025 From the Desk of: Glenn Jones, PE -CFM Principle Engineer/ Owner Email: giones@i4engineering.com To: Morgan Hester With: City of College Station Phone: 979 - 764 -3445 Fax: 979 - 764 -6258 RE: Case file No. 13- 00900098: Resubmittal Date: June 3, 2013 Notes: Attached are the revisions to the Development Plat for Plantation Oaks Addition that you requested in your letter dated May 31, 2013. The requested number of copies is enclosed and is hereby resubmittal for review and approval. The following is a summary of the items address: • The certifications for the owner, City Engineer, and P &Z Commission have been revised. • The certification for the City Planner has been deleted. • The 10' PUE requested by CSU has been added. Thank You.