HomeMy WebLinkAboutApplication (itrffil"44 FOR OFFICE USE ONLY _
P &Z CASE NO.: / — 1
DATE SUBMITTED'I — I.+r
CITY OF COLLEGE STATION 4:06
Planning & Development Services
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
E Filing Fee of $400.00.
N/A Variance Request to Subdivision Regulations - $100 (if applicable)
Application completed in full.
El Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Master Plan if applicable.
j. A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
N/A Rezoning Application if zone change is proposed.
E Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference:
NAME OF SUBDIVISION Pebble Creek Subdivision (Phases 9D, 9E, 9F, 9G & 9H)
SPECIFIED LOCATION OF PROPOSED SUBDIVISION
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Pebble Creek Country Club, Inc.
Street Address 4500 Pebble Creek Parkway City College Station
State TX Zip Code 77845 E -Mail Address
Phone Number (979) 690 -0992 Fax Number (979) 690 -6081
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name (Same as above)
Street Address City
State Zip Code E -Mail Address
Phone Number Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name McClure & Browne Engineering /Surveying, Inc.
Street Address 1008 Woodcreek Drive, Suite 103 City College Station
State TX Zip Code 77845 E -Mail Address mikem @mcclurebrowne.com
Phone Number (979) 693 -3838 Fax Number (979) 693 -2554
Total Acres of Subdivision 76.11 R -O -W Acreage 13.05 Total # of Lots 148
Number of Lots by Zoning District 148 / R -1
Average Acreage of Each Residential Lot By Zoning Distract: 0.46 / R -1
Floodplain Acreage -0- (Field Investigation indicates that Tots adjacent to floodplain are elevated above
base flood elevations. A LOMA will be prepared with the Final Plat.}
Parkland dedication by acreage or fee? Previously Dedicated
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if
applicable) N/A
Requested variances to subdivision regulations & reason for same: None
Requested oversize participation None
Parkland Dedication due prior to filing the Final Plat: Previously Dedicated
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
# of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single - Family Dwelling Units X $556 =$
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat and attests that all respective owners have been identified
on this application.
/
� &—e —e-c -- //3/OS
Si ature a • T itl- PzaJ6 EA.KiAL Date
(ikilliK1111111 SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
CITY OF COLLEGE STATION
Planning d' Development Services
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
® 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
® 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
® 3. Title Block with the following information:
® Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Z Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
® Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
® Engineer's scale in feet.
® Total area intended to be developed.
® 4. North Arrow.
® 5. Location of current city limit lines and current zoning district boundary.
® 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
® 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds description.)
® 8. Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
part.
® 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
® 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
elevation of streams.
6/13/03 3 of
Z 12. Proposed land uses (In compliance with Land Use Plan).
® 13. Proposed zoning changes, if any, submit formal rezoning request.
® 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
® ® Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
® ® Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
® ® Street offsets and /or intersection angles meet ordinance.
® Z Alleys.
® ® Reserve tracts.
® ® Well site locations.
® ® Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
® ® Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size /depth to meet the utility master plan and any future growth areas.
® ® Easements.
® ® Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
® ® A number or letter to identify each lot or site and each block.
® ® Greenbelt area /park linkages /parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
® ® Public areas
® ® Other public improvements, including but not limited to parks, schools and other public
facilities
® 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
® 16. Are there impact fees associated with this development? ['Yes ® No
® 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
® N/A
6/13/03 4 of
1 .1 11 1 1 .
(T\
„,2\,