MEMORANDUM
June 27, 2005
TO: Pebble Creek Country Club, Inc. (via fax 690 -6081)
FROM: Bridgette George, Development Coordinator
SUBJECT: PEBBLE CREEK PH 9D (FP) - Final Plat
Staff reviewed the above - mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed.
Two (2) 24 "x36" copies of the revised final plat;
Ten (10) 11"x17" copies of the revised final plat;
One (1) Mylar original with the appropriate signatures.
If you have any questions or need additional information, please call me at 979.764.3570.
Attachments: Staff review comments
cc: McClure & Browne Engineering /Surveying, Inc. (via fax 693 -2554)
Case file #05- 00500020
Home of Texas A &M University
STAFF REVIEW COMMENTS NO. 2
Project: PEBBLE CREEK PH 9 -D (FP) - 05- 00500020
PLANNING / ENGINEERING
1. This revised Final Plat will not require review by the Planning & Zoning Commission;
however, an item will be scheduled to advise the Commission of the revised Final Plat
approved by Staff since the previous Final Plat has not yet been filed.
2. Staff acknowledges the street name modifications affecting the cul -de -sac portions, from
"Drive" and "Lane" to "Court".
3. Staff acknowledges modifications to Lots 11 -14 of Block 47, including configuration, size,
and numbering based on the reduction of one lot in Phase 9 -E.
6-! A new 15' PDE & PUE is shown on the east side of Lot 13 in Block 47. If the 5' PUE on the
west side of Lot 14 is being retained it needs to be labeled.
4,4x A 20' PUE & PDE, 15' PDE and 5' PUE are still shown in the adjacent Phase 9 -D. If it was
dedicated by separate instrument, provide volume and page information.
6. Please provide additional easement width along existing 16" sewer line due to depth of line,
at least side setback width. ju"a.?
(2). A copy of the off -site Drainage Easement will be required before construction plan approval.
,l .g Off -site easement for water line through Phase F or blanket easement will be required prior
r`C" to construction plan approval.
9. Construction documents and reports still under review.
Reviewed by: TREY FLETCHER / CAROL COTTER Date: 6 -22 -2005
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. Developer provides 30' of rigid conduit for riser poles.
3. Developer installs pull boxes and secondary pedestal as per city specs and
design.(pull boxes and secondary pedestal provided by the city).
4. Developer is responsible for the install of 4 -4 inch sch 40 conduits for a proposed
electric feeder to be installed along St Andrews Dr.
5. Developer provides digital AutoCAD 2000 version of plat and /or site plan
email to bread a(�cstx.gov
10. Developer provides easements for electric infrastructure as installed for electric
lines (including street lights).
7. College Station Utilities will provide an electric design plan for the installation of
electric conduit, streetlighting and for necessary easement to be shown on final
plat.
8. To discuss any of the above electrical comments, please contact Tony Michalsky at
979.764.3438.
Reviewed by: Tony Michalsky Date: 6 -22 -05
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review. 2 of 2
(irff °11114
CITY OF COLLEGE STATION
Planning & Development Services
1101 Texas Avenue, P.O. Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
July 14, 2005
TO: Pebble Creek Country Club, Inc., via fax 690.6081 ✓
FROM: Bridgette George, Development Coordinator
SUBJECT: PEBBLE CREEK PH 9D (FP) Construction Documents
Staff reviewed the above - mentioned construction documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information for
further staff review and approval:
Three (3) complete sets of construction documents for the proposed
development.
Easement Dedication Sheet and necessary documents.
If you have any questions or need additional information, please call Carol Cotter at
764.3570.
Attachments: Staff review comments
cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554
Case file #05- 00500020
Home of Texas A &M University
STAFF REVIEW COMMENTS
Project: PEBBLE CREEK PH 9D (FP) - 05- 00500020
ENGINEERING
1. Show conflict with water line on Sheet 7. Your response indicated that the only
conflict was on SD -N. The storm sewer crosses the 8" water line at the intersection
of Ballybunion and St Andrews. From Sheet 12, it looks like you may need to center
a joint of storm pipe so that the bell does not encroach in to the 6" vertical
separation.
2. Show conflict with storm sewer (Sheet 13, WA -3). Previous comment.
3. A 2" blow -off is required on 3" water lines per design guidelines.
4. Please revise cost estimate.
5. Easement dedication sheet and supporting docs will need to be submitted for
drainage easement to be assigned. This will not hold up construction plan approval.
Reviewed by: Carol Cotter Date: July 13, 2005
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the
City, will constitute a completely new review. 2 of 2
, _., .
I S McCLUi., & BROWNE ENGINEERING - SURVEYING, INC.
1008 «'oodcreek Drive, Suite 103 • College Station, Texas 77841
(979) 693 -3838 • Fax (979) 693 -2114 • Email: mcclurebrowne(J verizon.net
057
July 1, 2005 3 30
Mrs. Bridgette George, Development Coordinator
CITY OF COLLEGE STATION
P.O. Box 9960
College Station, Texas 77842
RE: Pebble Creek, Phase 9 -D
Response to Staff Review Comments
Dear Bridgette:
Attached please find two (2) 24" X 36" blueline prints and ten (10) 11" X 17" copies of the above
referenced final, revised per Staff Review comments dated 6/27/2005. The mylarwill be submitted as soon
as possible.
I have the following responses to the PLANNING /ENGINEER comments as follows:
1. No response required.
2. No response required.
3. No. response required.
4. A new 15' P.D.E. & P.U.E. is shown on the east side of Lot 13, Block 47. If the 5' P.U.E. on
the west side of Lot 14 is being retained it needs to be labeled.
The plat shows the easements as intended
5. A 20' P.U.E. & P.D.E., 15' P.D.E. & 5' P.U.E. are still shown in the adjacent Phase 9 -E. If it
was dedicated by separate instrument, provide volume & page information
Revised as requested.
6. Please provide additional easement width along existing 16" sewer line due to depth of
line, at least side setback width.
Carol is to reconsider this request since it is not consistent with the design guidelines.
7. A copy of the off -site Drainage Easement will be required before construction plan
approval.
Kym Wagner of Pebble Creek Development will deliver this information under separate cover.
8. Off -site easement for water line through Phase F or blanket easement will be required prior
to construction plan approval.
Kym Wagner of Pebble Creek Development will deliver this information under separate cover.
Should you have any questions or need additional information, please advise.
Very truly yours,
M chael R. Mc u , P.E., R.P.L.S.
President
MRM /mlm
attachments
(k.if"
CITY OF COLLEGE STATION
Planning & Development Services
1101 Texas Avenue, P.O. Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
July 1, 2005
TO: Pebble Creek Development Company, via fax 690.6081
FROM: Bridgette George, Development Coordinator
SUBJECT: PEBBLE CREEK PH 9D (FP)
Staff reviewed the above - mentioned engineering documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information for
further staff review and approval of the plans:
One (1) set of revised construction documents.
If you have any questions or need additional information, please Carol Cotter or myself
at 764.3570.
Attachments: Staff Review Comments
Cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554
Case file no. 05- 00500020
Home of Texas A&M University
PEBBLE CREEK PH 9D (FP) (05- 00500020)
ENGINEERING REVIEW
COMMENTS No. 3
1. Off -site easement for water line through Phase F or blanket easement will be
required prior to construction plan approval.
2. Add sidewalk to Cascades Court and to the PAE between Lots 48 and 49 as noted
on Preliminary Plat.
3. Show conflict with storm sewer (SHT 13, WA -3).
4. Show conflict with water line (SHT 7, both profiles).
5. Show conflict with sanitary sewer (SHT 8).
6. The construction plans will be approved to construct Phase 9D only.
7. Plans show previous storm sewer sizes for conflicts (SHT 12, 14).
8. A portion of the 42 -inch storm sewer on Sheet 7 is mislabeled HDPE.
9. The layout of the storm sewer system at the end of Olympic Court in the
construction documents does not match that in the drainage report.
10. Drainage Report - A note is provided that indicates flow is increased 33% for pipes
in excess of 27 inch diameter; however, the numbers don't appear to reflect that in
comparing the unadjusted with adjusted flows columns.
11. Drainage Report - Many of the pipe lengths in Exhibit C do not match the lengths
indicated on the plans.
12. Drainage Report — What do inlets 19A, 19B, 26A, and 26B represent?
13. Drainage Report- Drainage area calculations for Pond Out are not the same as
those provided in the drainage report for Phase 9E. Verify.
14. Provide detention pond design information.
15. If oversized participation is requested it has to be considered by Council before DP
can be issued.
Reviewed by: Carol Cotter Date: June 30, 2005
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City of College Station will constitute a completely new review.
Page 2 of 2
0 - 0
( 1111 I I 1 :*# 1114 I
CITY OF COLLEGE STATION
Planning es- Development Services
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
April 5, 2005
TO: Pebble Creek Development Company, via fax 690.6081
FROM: Bridgette George, Assistant Development Manager
SUBJECT: PEBBLE CREEK PH 9D (FP) — Construction Documents
Staff reviewed the above - mentioned engineering documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information for
further staff review and approval of the plans:
Two (2) sets of revised construction documents.
If you have any questions or need additional information, please call Carol Cotter or
myself at 764.3570.
Attachments: Staff Review Comments
Cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554 ✓
Case file no. 05- 00500020
Home of Texas ABM University
PEBBLE CREEK PH 9D (FP) (05- 00500020)
ENGINEERING REVIEW
COMMENTS No. 2
1. A copy of the off -site Drainage Easement will be required before construction
plan approval.
2. Off -site easement for water line through Phase F or blanket easement will be
required prior to construction plan approval.
3. Add sidewalk to Cascades Court and to the PAE between Lots 48 and 49 as
noted on Preliminary Plat.
Reviewed by: Carol Cotter Date: April 4, 2005
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City of College Station will constitute a completely new review.
Page 2 of 2
*if illiiii1111111111
CITY OF COLLEGE STATION
Planning er Development Services
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
March 11, 2005
TO: Pebble Creek Development Company, via fax 690.6081
FROM: Bridgette George, Assistant Development Manager
SUBJECT: PEBBLE CREEK PH 9D (FP)
Staff reviewed the above - mentioned engineering documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information
for further staff review and approval of the plans:
Two (2) sets of revised construction documents.
If you have any questions or need additional information, please call Carol Cotter
or myself at 764.3570.
Attachments: Staff Review Comments
Cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554
Case file no. 05- 00500020
Home of Texas A&M University
PEBBLE CREEK PH 9D (FP) (05- 00500020)
Engineering Review
Comments No. 1
1. Either separate Phases 9D and 9F or indicate construction requirements for
each phase on construction documents. As submitted, each phase needs to
stand on its own.
2. Where there is a change in pipe diameter, the soffit of smaller upstream pipe
shall at least match the soffit of the larger pipe. (Inlet 19)
3. St Andrews Drive requires bike lanes in accordance with Bikeways Master
Plan. Please note on construction documents.
4. Make sure the low point is graded to drain where St Andrews Drive (Sta
61 +75) meets future Pebble Creek Parkway.
5. A number of the water /sanitary crossings do not specify centering joint of
water pipe on profile.
6. Water Line WA -1 — Sta 259 +81 should center on S /L.
7. Water, Sewer and Drainage Reports are okay.
Reviewed by: Carol Cotter Date: March 11, 2005
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City of College Station will constitute a completely new review.
Page 2 of 2
(
CITY OF COLLEGE STATION
Planning & Development Services
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
March 11, 2005
TO: Pebble Creek Development Company, via fax 690.6081
FROM: Bridgette George, Development Coordinator
SUBJECT: PEBBLE CREEK PH 9D (FP) - Final Plat
Staff reviewed the above - mentioned final plat as requested. The following page is a list
of staff review comments detailing items that need to be addressed. If all comments
have been addressed and the following information submitted by Monday, March 21,
10:00 a.m., your project will be placed on the next Planning and Zoning Commission
meeting scheduled for, Thursday, April 7, 2005, 7:00 p.m. in the City Hall Council
Chambers, 1101 Texas Avenue, pending City Council approval of the rezoning of a
portion of this property at the special City Council meeting scheduled for Wednesday,
March 30:
Two (2) 24 "x36" copies of the revised final plat;
Ten (10) 11"x17" copies of the revised final plat;
One (1) Mylar original of the revised final plat; and
One (1) copy of the digital file of the final plat on diskette or e-mail to
nmanhart@cstx.gov
Upon receipt of the required documents for the Planning & Zoning meeting, your project
will be considered formally filed with the City of College Station. Please note that if all
comments have not been addressed your project will not be scheduled for a Planning &
Zoning Commission meeting. Your project may be placed on a future agenda once all
the revisions have been made and the appropriate fees paid. If you have any questions
or need additional information, please call Carol Cotter or myself at 979.764.3570.
Attachments: Staff review comments
cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554 c /
Case file #05- 00500020
Home of Texas A&M University
STAFF REVIEW COMMENTS NO. 1
Project: PEBBLE CREEK PH 9D (FP) - 05- 00500020
ENGINEERING
1. Show floodplain boundaries on the Plat, based on FEMA BFE of 230.
2. Provide Finished Floor Elevations for lots in the Floodplain.
3. Provide offsite drainage easement.
4. Dedicate PUE for 16 -inch sewer line (outside plat boundaries).
5. Add note to plat that driveway access for corner lots on St Andrews Drive will be to
lesser street.
Reviewed by: Carol Cotter Date: March 10, 2005
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. Developer provides 30' of rigid conduit for riser poles.
3. Developer installs pull boxes and secondary pedestal as per city specs and
design.(pull boxes and secondary pedestal provided by the city).
4. Developer is responsible for the install of 4 -4 inch sch 40 conduits for a proposed
electric feeder to be installed along St Andrews Dr.
4. Developer provides digital AutoCAD 2000 version of plat and /or site plan
email to breadl'a cstx.gov
6. Developer provides easements for electric infrastructure as installed for electric
lines (including street lights).
7. Will need a 10 ft. easement along the south side of St Andrews Drive for proposed
underground feeder route.
8. To discuss any of the above electrical comments, please contact Tony Michalsky
at 979.764.3438.
Reviewed by: Tony Michalsky Date: 2 -16 -05
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
Page 2 of 2
CITY OF COLLEGE STATION
Planning & Development Services
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
March 11, 2005
TO: Pebble Creek Development Company, via fax 690.6081
FROM: Bridgette George, Assistant Development Manager
SUBJECT: PEBBLE CREEK PH 9D (FP)
Staff reviewed the above - mentioned engineering documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information
for further staff review and approval of the plans:
Two (2) sets of revised construction documents.
If you have any questions or need additional information, please call Carol Cotter
or myself at 764.3570.
Attachments: Staff Review Comments
Cc: McClure & Browne Engineering /Surveying, Inc., via fax 693.2554
Case file no. 05- 00500020
Home of Texas ABM University
PEBBLE CREEK PH 9D (FP) (05- 00500020)
Engineering Review
Comments No. 1
1. Either separate Phases 9D and 9F or indicate construction requirements for
each phase on construction documents. As submitted, each phase needs to
stand on its own.
2. Where there is a change in pipe diameter, the soffit of smaller upstream pipe
shall at least match the soffit of the larger pipe. (Inlet 19)
3. St Andrews Drive requires bike lanes in accordance with Bikeways Master
Plan. Please note on construction documents.
4. Make sure the low point is graded to drain where St Andrews Drive (Sta
61 +75) meets future Pebble Creek Parkway.
5. A number of the water /sanitary crossings do not specify centering joint of
water pipe on profile.
6. Water Line WA -1 — Sta 259 +81 should center on S /L.
7. Water, Sewer and Drainage Reports are okay.
Reviewed by: Carol Cotter Date: March 11, 2005
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City of College Station will constitute a completely new review.
Page 2 of 2
MEMORANDUM
March 24, 2005
TO: Planning and Zoning Commission
FROM: Trey Fletcher
Email: tfletcher@cstx.gov
SUBJECT: FINAL PLAT for PEBBLE CREEK SUBDIVISION PHASE 9D
Item: Presentation, discussion and possible action on a Final Plat for Pebble
Creek Phase 9D consisting of 49 lots on 22.427 acres generally located in the
vicinity of Cascades Drive, north of the Alum Creek floodplain and west of the
future extension of Pebble Creek Parkway.
Applicant: Pebble Creek Country Club, Inc.
Staff Recommendations: Staff recommends approval of the Final Plat.
Item Summary: This item is for consideration of a Final Plat for Pebble Creek
Phase 9D. This phase is located west of the future extension of Pebble Creek
Parkway, but access will be via Cascades Drive to the north. To the south is the
Alum Creek floodplain within which is a planned bike path to which a pedestrian
access way has been indicated at the end of Cascades Drive.
The Final Plat is in compliance with the approved Preliminary Plat.
Comprehensive Plan Considerations:
Land Use Plan: Single - family Residential (low and medium density). The plat
shows gross density of 2.18 dwelling units per acre.
Thoroughfare Plan: St. Andrews Drive is classified as a Minor Collector which
connects to the future extension of Pebble Creek Parkway.
Parkland Dedication: Dedication requirements for Pebble Creek have been
satisfied.
Budgetary & Financial Summary: Although this phase is adjacent to the future
extension of Pebble Creek Parkway, this is off -site being that the land for the
future corridor is owned by the City of College Station.
Attachments:
1. Location map
2. Aerial Map
3. Application
4. Coov of Final Plat