Loading...
HomeMy WebLinkAboutStaff Review Comments(*// CITY OF COLLEGE STATION Planning & Development Services 1101 Texas Avenue, P.O. Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 MEMORANDUM December 2, 2005 TO: J. Brett Cumpton, Applicant via fax 979.774.9298 FROM: Crissy Hartl, Staff Planner SUBJECT: POPEYE'S RESTAURANT (SP)- Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: One (1) 11 x17 grading and erosion control plan One (1) revised site and landscaping plan. Easement Dedication Sheet and required documents. Please note that the Easement Dedication Sheet and the necessary documents are required prior to the issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me or Josh Norton at 979.764.3570. Attachments: Staff review comments cc: John Dawson, Popeye's Development Services via mail to: 5555 Glen Rose, Connector NE Suite 300, Atlanta, GA 30342 Brian Brummit, Brazos Valley Engineering, Inc. via fax 979.693.6946 Case file #05- 00500210 Home of Texas A &M University STAFF REVIEW COMMENTS NO. 1 Project: POPEYE'S RESTAURANT (SP) — 05- 00500210 PLANNING 4 Please include all required information in the title block. Such information includes: �, Name, address, location and legal description Name, address, and telephone number of applicant. Name, address, and telephone number of developer /owner (if differs from applicant) Name, address, and telephone number of architect/engineer (if differs from applicant) Date of submittal JA Total site area •-2. Please remove all sign details from site plan as signs will be permitted separately. Please {? note that this lot is included in a building plot for combined signage. The building plot V� includes Lots 1 -6 of Block One of the Graham Corner Plaza plat. 3. Please scale site plan to largest standard engineering scale possible on sheet. �4. Please include all planning related items on one site plan, including parking, setbacks, ownersmip and current zoning of parcel and all abutting parcels, etc. Please refer to attached checklist for minimum site plan requirements. 5 Please measure building setbacks from the property line. The building setback on the eastern property line is not measured correctly. Please indicate if there is 100 -year floodplain and floodway on or adjacent to the proposed project site, or provide note if there is none with confirming FEMA/FIRM map number. 7/ Please label existing sidewalks and right -of -way width. 9: Please dimension drive aisles and driveway throat length from Graham Road. 9° Please indicate whether the drive aisles are one way or two ways. --�$Q. Please put proposed curb and pavement details on the site plan. 1J. Please label, alter or delete the recessed curb at the south portion of the lot. If this area is intended for parallel parking, please stripe the spaces and dimension them. - - t (,rap• cv(4 0111 Please make sure all easements are measured correctly. The public utility easement along J the southern property line is not measured correctly. 13 Please show proposed and existing fire hydrants. Please remove the fire lane around the building. Per Fire Marshall Steve Smith, this site is not required to have a fire lane, but is required to have a sign at the driveway. The northern ,drive aisle, along Graham Rd., will serve as the "fire lane." 1o'. The interior clearance (inside the screen) dimensions needs to be a minimum 12'x12' pad. 16. Staff recommends the driveway off of the access easement be moved further away from Graham Road to improve on -site circulation. 11. Provide a general note that all roof and ground- mounted mechanical equipment shall be screened from view or isolated so as not to be visible from any public right -of -way or residential district within 150' of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Reviewed by: Crissy Hartl Date: December 1, 2005 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 4 LAN DSCAPING /STREETSCAPING /BU FFER 4. , Please provide the caliper- inches of the canopy trees in the Plant Legend. -: This site is required 1,554 landscape points. The Plant Legend indicates only 1,490 landscape points. Please adjust accordingly. 3' Please be aware that you must submit a landscape irrigation plan and receive approval or provide a note stating how irrigation system requirement will be met prior to issuance of Certificate of Occupancy. 4. Bicolor Iris (Moraea bicolor) is not on our approved landscape list. Please choose an approved shrub or provide hardiness information and a picture of the Bicolor Iris. 5. Please reflect the correct number of Indian Hawthorne shrubs. The Plant Legend indicates 52 shrubs, but staff counted 53. 6: Please screen the side of the parking stalls from the right -of -way along Graham Road. T. Please be aware that Graham Road is a collector and therefore needs a canopy tree every -` 32' rather than every 25' as indicated on the landscape plan. Please adjust accordingly. 9. Provide a general note that 100% coverage of groundcover, decorative paving, decorative rock, or a perennial grass is required in parking lot islands, swales and drainage areas, the parking lot setback, rights -of -way, and adjacent property disturbed during construction. Reviewed by: Crissy Hartl Date: December 1, 2005 ENGINEERING 1. Provide water and sewer demands. 2. Label existing water and sewer main sizes. 3. Verify locations of water and sewer mains as our records indicate you have shown them incorrectly. 4. Label location and size of domestic and irrigation water meters. Meters should be fed off single tap of main. 5. Meters must be located within an easement. 6. Label any required back flow preventers for water system. 7. Label domestic water service line size and material type (Type K Copper). 8. Label sanitary sewer service line size (6 "), slope (1 %), and material type (SDR 26 ASTM D3034). A clean -out is required every 100 -ft. 9. Upon submitting development permit application and fees, submit fire flow report and drainage report. Reviewed by: Josh Norton Date: December 2, 2005 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer pours transformer pad(s) per city specs and design. 3. Developer installs pull boxes as per city specs and design.(pull boxes provided by the city). 4. Developer provides digital AutoCAD 2000 version of plat and /or site plan email to gmartinez cD_cstx.gov 5. Developer provides load data for project. 6. Developer provides temporary blanket easement for construction purposes. 7. Developer provides easements for electric infrastructure as installed for electric lines. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 4 8. To discuss any of the above electrical comments, please contact Gilbert Martinez at 979.764.6255. Reviewed by: Gilbert Martinez Date: 12 -01 -05 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker, a Reduced Pressure Principle Back Flow Device, or a Double -Check Back Flow Device, and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 4 of 4