HomeMy WebLinkAboutApplicationFOR OFFICE USE ONLY
_►y~" P&Z CASE NO.: O `f - )q3
T DATE SUBMITTED:
PRELIMINARY PLAT APPLICATION
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
Filing Fee of $400.00.
Variance Request to Subdivision Regulations - $100 (if applicable)
Application completed in full.
Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
One (1) copy of the approved Master Plan if applicable.
A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
Rezoning Application if zone change is proposed.
Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
Date of Preapplication Conference: FEBRUARY 18, 2004 00
NAME OF SUBDIVISION HORSE HAVEN ESTATES PHASE TWO
SPECIFIED LOCATION OF PROPOSED SUBDIVISION EARL RUDDER FREEWAY BEHIND ACADEMY
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name ALTON E OFCZARZAK GENERAL MANAGER OAKWOOD CUSTOM HOME GROUP, INC.
Street Address P.O. BOX 9849 City COLLEGE STATION
State TEXAS Zip Code 77842 E-Mail Address alton oakchb.com
Phone Number 979-690-1504Fax Number 979-690-2504
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for
multiple owners):
Name BURT HERMANN
Street Address 2701 HORSE HAVEN LANECity COLLEGE STATION
State TEXAS Zip Code 77845 E-Mail Address
Phone Number 979-693-9513 Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name MICHAEL G. HESTER P.E., HESTER ENGINEERING COMPANY
Street Address 7607 EASTMARK DRIVE. SUITE 253-B City COLLEGE STATION
State TX Zip Code 77840 E-Mail Address mhester(cD-hester-engr.com
Phone Number 979-693-1100 Fax Number 979-693-1075
4
Total Acres Of Subdivision 13.88 R-O-W Acreage 1.85 Total # Of Lots 58
Number Of Lots By Zoning District 58 /RR=1
Average Acreage Of Each Residential Lot By Zoning District:
Floodplain Acreage 0
Parkland dedication by acreage or fee? FEE
A statement addressing any differences between the Preliminary Plat and approved Master Plan (if
applicable) NA
Requested variances to subdivision regulations & reason for same NA
Requested oversize participation OVERSIZED STORM SEWER TO ACCOMMODATE UPSTREAM
PROPERTY
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
# of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
58 # of Single-Family Dwelling Units X $556 = $ 32.248
8-10-4 (date) Approved by Parks & Recreation Board
The applicant has preps d is application and cert~es that the facts stated herein and exhibits
attached hereto are true an correct. The undersigned hereby requests approval by the City of
College Station of the ab ve dentfed plat and attests that all respective owners have been identified
on this application. r'
Signature a Date
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1.v"(Srawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
2. LVicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
❑ 3. Title Block with the following information:
L, Name and address of subdivider, recorded owner, planner, engineer and surveyor.
/,Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
L-Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
'-Engineer's scale in feet.
L-Total area intended to be developed.
^Q 4. "North Arrow.
5. Location of current city limit line nd current zoning district boundary.
6. Subdivision boundary indicated by heavy lines. ou ary must include all of parent tract.
7. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a comer of the survey or tract, or an original comer of the original survey
of which it is a part.
'RI 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
`Q 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
12. Proposed land uses (In compliance with Land Use Plan).
`H 13. Proposed zoning changes, if any, submit formal rezoning request.
❑ 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing
*tYno
Proposed
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
"IS
❑ ❑
1-9 "E
❑ ❑
❑ ❑
❑ ~
Street offsets and/or intersection angles meet ordinance.
Alleys.
Reserve tracts.
Well site locations.
Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
Easements.
Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
A number or letter to identify each lot or site and each block.
Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission
consideration.)
❑ ❑ Public areas
❑ ❑ Other public improvements, including but not limited to parks, schools and other public
facilities
15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
16. Are there impact fees associated with this development? ❑ Yes "-E] No
❑ 17. If requesting oversize participation items, are the necessary impact studies included?
❑Yes
❑No
❑ N/A